Free English MOXA PT-G510-4GTX4GSFP-PHR (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD MOXA PT-G510-4GTX4GSFP-PHR (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

What items are included in the package for the MOXA PT-G510-4GTX4GSFP-PHR?

The MOXA PT-G510-4GTX4GSFP-PHR is shipped with the following items. If any of these items are missing or damaged, please contact your customer service representative for assistance.

• PT-G510 switch

• DIN-rail kit

• Protective caps on SFP ports and USB Storage ports

• RJ45 to DB9 Cable

• Quick installation guide (printed)

• Substance Disclosure Table

• Product Certificate of Quality Inspection

• Product Notices

• Warranty card


What are the default network settings for the MOXA PT-G510-4GTX4GSFP-PHR?

The default settings for the MOXA PT-G510-4GTX4GSFP-PHR are as follows:

• Default IP address: 192.168.127.253

• Default Subnet Mask: 255.255.255.0

• Default Usernames: admin, user

• Default Password: moxa


What are the main components on the front panel of the MOXA PT-G510-4GTX4GSFP-PHR?

The front panel of the MOXA PT-G510-4GTX4GSFP-PHR includes the following components:

• System LED Indicators

• Console Port

• USB Storage Port

• 100/1000Base SFP A/B Port

• 10/100/1000BaseT(X) Port

• 100/1000Base SFP Slots

• Power Connector

• Relay


How can I interpret the LED indicators on the MOXA PT-G510-4GTX4GSFP-PHR?

The front panel of the MOXA PT-G510-4GTX4GSFP-PHR contains several LED indicators. The function of each LED is described in the tables below:

System LEDs

LED Color State Description
State (S) Green On When system has passed power-on self-test (POST) and is ready to run.
Blinking

• When the reset button is pressed for 5 seconds to reset to factory default.

• When a USB drive is detected.

• Web locator is on.

Off N/A
FAULT (F) Red On

• Switch initialization failure.

• When the power-on self-test (POST) fails.

On

• USB detected/operation failed.

• Network loop detected when loop protection is enabled.

• Relay NC is on.

• The ring port connection is not valid.

Blinking

• EEPROM information error.

• Web locator is on.

Off The system is operating normally, and no user-configured event is triggered.
Power1 (P1) Amber On Power is being supplied to power input P1.
Off Power is not being supplied to power input P1.
Power2 (P2) Amber On Power is being supplied to power input P2.
Off Power is not being supplied to power input P2.
MSTR/HEAD (M/H) Green On

• EEPROM information error.

• When the switch is Master/Head/Root of Turbo Ring/Turbo Chain/Fast RSTP.

• When the switch is MRM of MRP and the MRP ring is closed.

Blinking

• When the switch is Ring Master/Head of Turbo Ring/Turbo Chain, and the Turbo Ring/Turbo Chain is broken.

• When the switch is MRM of MRP and the MRP ring is broken.

• Web locator is on.

Off When the switch is not the Master/Head/Root of this Turbo Ring/Turbo Chain/Fast RSTP.
CPRL/TAIL (C/T) Green On

• When the switch enables the coupling function to form a back-up path.

• When the switch is tail of Turbo Chain.

Blinking

• When the switch is enabled Turbo Chain and Turbo Chain is broken.

• Web locator on.

Off When the switch disables the coupling or tail role of Turbo Chain.
SYNC Amber On The PTP function is enabled and is in the free-run state.
Blinking The PTP function is enabled, and switch is in syncing state.
Green On The PTP function has successfully converged
Off The PTP function is off.

Redundancy LEDs

LED Color State Description
PRP Green On PRP mode is enabled.
Off PRP mode is disabled.
HSR Green On HSR mode is enabled.
Off HSR mode is disabled.
Coupling Green On PRP/HSR Coupling mode is enabled.
Off PRP/HSR Coupling mode is disabled.

Port LEDs

LED Color State Description
10M/100M/1000M Copper Green On When the port is active, and link is on 1000 Mbps.
Blinking When the port’s data is being transmitted at 1000 Mbps.
Off When the port is inactive, or link is down.
Amber On When the port is active, and link is on 100/10 Mbps.
Blinking When the port’s data is being transmitted at 100/10 Mbps.
100M/1000M SPF Green On When the port is active, and the link is on 1000 Mbps.
Blinking When data is being transmitted at 1000 Mbps.
Off When the port is inactive or the link is down.
Amber On When the port is active and the link is on 100 Mbps.
Blinking When data is being transmitted at 100 Mbps.
Off When the port is inactive, or link is down.

How do I install the MOXA PT-G510-4GTX4GSFP-PHR onto a DIN rail?

The DIN-rail mounting kit is fixed to the back panel of the MOXA PT-G510-4GTX4GSFP-PHR by default. To install it, mount the device on a corrosion-free mounting rail that meets the EN 60715 standard.

STEP 1: Insert the upper lip of the DIN rail into the DIN-rail mounting kit.

STEP 2: Press the MOXA PT-G510-4GTX4GSFP-PHR towards the DIN rail until it snaps into place.


How do I remove the MOXA PT-G510-4GTX4GSFP-PHR from a DIN rail?

STEP 1: Pull down the latch on the mounting kit with a screwdriver.

STEP 2 & 3: Slightly pull the MOXA PT-G510-4GTX4GSFP-PHR forward and lift to remove it from the DIN rail.


What are the power input requirements for the MOXA PT-G510-4GTX4GSFP-PHR?

The MOXA PT-G510-4GTX4GSFP-PHR series supports various types of power supplies:

• WV models come with two 24 to 48 VDC power inputs.

• HV models come with two 110 to 220 VDC/VAC power inputs.

This equipment is intended to be supplied by an external power source (UL listed/ IEC 60950-1/ IEC 62368-1) with an output rating of 24 to 48 VDC, 1.1 A (minimum) or 110 to 220 VDC, 0.3 A (minimum), and an ambient temperature of 75°C (minimum).


Are there specific recommendations for wiring the dual power inputs on the MOXA PT-G510-4GTX4GSFP-PHR?

Yes, if you intend to use more than 220 VAC/VDC (combined total) to power the dual power inputs, you must consider the following scenarios:

PWR1 PWR2 Recommendations
220 VAC 220 VDC We do not recommend using this combination for the dual power inputs because the AC voltage difference between PWR1 and PWR2 exceeds 264 VAC RMS. This can damage the power board.
220 VAC 110 VDC
220 VAC 220 VAC

Use a qualified digital multimeter (e.g., a Fluke 85 V or equivalent) to measure and ensure the AC voltage difference between PWR1 and PWR2 is within the 264 VAC. If the difference in AC voltage exceeds 264 VAC RMS, an isolation transformer (220 V to 110 V; minimum 50 VA) must be used between the device and the AC power source to avoid damage from power surges.

How to measure the voltage difference*:
You will need to measure the voltage difference between 4 pairs of wires, as listed below:

[L1-N1], [L1-N2], [L1-L2]

[N1-N2], [N1-L2], [N2-L2]

220 VAC 110 VAC
220 VDC 220 VDC
220 VDC 110 VDC Use an isolation transformer (220 V to 110 V; minimum 50 VA) between the device and the Uninterruptible Power Supply (UPS) source to avoid damage from power surges.

*Applies even if the PWR1 and PWR2 configurations are reversed.


What is the procedure for connecting power to the MOXA PT-G510-4GTX4GSFP-PHR?

Before connecting the MOXA PT-G510-4GTX4GSFP-PHR to AC or DC power inputs, make sure the power source voltage is stable.

For HV Models:

STEP 1: Insert the positive/negative DC or line/neutral AC wires into the V+/V- or L/N terminals, respectively.

STEP 2: Use a flat-blade screwdriver to tighten the wire-clamps on the front of the terminal block connector to fasten the wires.

STEP 3: Insert the plastic terminal block connector prongs into the terminal block receptor.

For WV Models:

STEP 1: Insert the positive/negative DC wires into the V+/V- terminals, respectively.

STEP 2: Use a flat-blade screwdriver to tighten the wire-clamps on the front of the terminal block connector to fasten the wires.

STEP 3: Insert the plastic terminal block connector prongs into the terminal block receptor.

If you intend to only use one power input, be sure to disconnect the other power input (unplug the power cord or disconnect the power input from the L and N contacts). Only one power input LED will be on.


How do I wire the relay contact on the MOXA PT-G510-4GTX4GSFP-PHR?

The relay contact of the 3-pin terminal block connector is used to detect user-configured events. The module provides normally open (NO) and normally closed (NC) circuits. Two wires are attached to the relay pins with normally close and normally open options. The function is as follows:

Relay connection Power on state Event trigger
NO and COM Closed circuit Open circuit
NC and COM Open circuit Closed circuit

When wiring the relay contact, DI, and power inputs, we suggest using the cable type – AWG (American Wire Gauge) 16-24 (1.31-0.205 mm²) and the corresponding pin type cable terminals. The connector must be able to withstand torque at maximum 5 pound-inches. The rated temperature of wiring should be at least 105°C.


How should the MOXA PT-G510-4GTX4GSFP-PHR be grounded?

Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the ground screw (M4) to the grounding surface prior to connecting devices. Using a shielded cable achieves better electromagnetic resistance. Use a green-yellow grounding cable with a wire size AWG 18 or higher to ground this product to earth.


How do I connect to the RJ45 console port on the MOXA PT-G510-4GTX4GSFP-PHR?

The MOXA PT-G510-4GTX4GSFP-PHR has one RJ45 console port (RS-232) located on the front panel. Use an RJ45-based cable to connect the console port to your PC’s COM port. You may then use a console terminal program to access the switch with a baudrate of 115200. The pin definition of the console port is as follows:

Pin Signal
1 –
2 RTS
3 –
4 TxD
5 RxD
6 GND
7 CTS
8 –

How do I use the USB storage port on the MOXA PT-G510-4GTX4GSFP-PHR?

The USB storage port is on the front panel of the switch and has a type A connector. Use Moxa’s ABC-02-USB automatic backup configurator to connect to the USB port to perform configuration backup, firmware upgrade, or system log file backup. The pinout assignments are:

Pin Description
1 VCC (+5V)
2 D- (Data-)
3 D+ (Data+)
4 GND (Ground)

How can I reset the MOXA PT-G510-4GTX4GSFP-PHR to its factory default settings?

Use a pointed object, such as a straightened paper clip or toothpick, to depress the Reset button. When you do so, the STATE LED will start to blink about once per second. Continue to hold the button until the STATE LED begins blinking more rapidly; this indicates that the button has been depressed for five seconds. You can then release the Reset button to load factory default settings. DO NOT power off the switch when loading default settings.


How do I back up configuration and log files on the MOXA PT-G510-4GTX4GSFP-PHR?

When the ABC-02-USB is connected to the MOXA PT-G510-4GTX4GSFP-PHR, the reset button allows for a quick backup of configuration and event logs to the ABC-02-USB. Press the reset button to start backing up the current system configuration files and event logs to the ABC-02-USB. Note that when the ABC-02 is plugged in, you cannot reset to factory default by pressing the reset button.


What are the key specifications for the MOXA PT-G510-4GTX4GSFP-PHR?

Technology

Standards IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseX
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1p for Class of Service
IEEE 802.1Qfor VLAN Tagging
IEEE 802.1X for authentication
IEEE 802.3ad for Port Trunk with LACP
IEEE 802.3x for flow control

Input Output Interface

Digital Input • +13 to +30 V for state 1
• -30 to +3 V for state 0
• Max. input current: 8 mA
Alarm Contact Channels Resistive load: 1 A @ 24 VDC

Ethernet Interface

10/100/1000BaseT(X) ports (RJ45 connector) PT-G510-4GTX4GSFP-PHR Models: 4
100/1000Base SFP slots PT-G510-4GTX4GSFP-PHR Models: 6

Power Parameters

Rated Input Voltage PT-G510-PHR-HV Models: 110 to 220 VAC, 50/60 Hz, 110 to 220 VDC
PT-G510-PRP-WV Models: 24 to 48 VDC
Note: Both -HV and -WV models support dual power inputs with a single power module.
Overload Current Protection Yes
Reverse Polarity Protection Yes
Rated Input Current PT-G510-PHR-HV Models: 0.5 A @ 110 to 220 VAC
PT-G510-PHR-HV Models: 0.3 A @ 110 to 220 VDC
PT-G510-PHR-WV Models: 1.1 A @ 24 to 48 VDC
Power Consumption (Max.) PT-G510-8GSFP-PHR-HV Models:
• 110 VAC: 23.54 W
• 220 VAC: 24.57 W
• 110 VDC: 23.485 W
• 220 VDC: 23.88 W
PT-G510-8GSFP-PHR-WV Models:
• 24 VDC: 21.868 W
• 48 VDC: 22.646 W

Physical Characteristics

IP Rating IP30
Dimensions 74 x 148 x 120 mm (2.91 x 5.83 x 4.72 in)
Weight 1,476 g (3.3 lb)
Installation DIN-rail mounting

Environmental Limits

Operating Temperature -40 to 75°C (-40 to 167°F)
-40 to 85°C (-40 to 185°F) for 16 hrs based on 85°C test in accordance with IEC 60068-2-2.
Storage Temperature (Package Included) -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)

Standards and Certifications

Safety UL 62368-1, IEC 62368-1
EMI CISPR 32, FCC Part 15B Class A
EMC EN 55032/35
EMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
EN61000-4-11
Power Substation IEC 61850-3 Edition 2.0 Class2, IEEE 1613, IEC 60255-26
Railway EN 50121-4
Marine DNV, IEC 60945 (-WV models only)

What are the important safety warnings for the MOXA PT-G510-4GTX4GSFP-PHR?

Please observe the following safety warnings when installing and operating the MOXA PT-G510-4GTX4GSFP-PHR:

Safety First!

• Be sure to disconnect the power cord before installing and/or wiring your Ethernet Switch. Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size. If the current goes above the maximum ratings, the wiring could overheat, which can cause serious damage to your equipment.

Laser Safety

• Use only a Laser Class 1 optical transceiver with this device.

Wiring Requirements

• Do not disconnect modules or wires unless power has been switched off or the area is known to be non-hazardous. The device may only be connected to the supply voltage shown on the type plate. The device is designed for operation with an isolated power supply, which means that the device may only be connected to the supply voltage connections and to the signal contact with an isolated power supply in compliance with IEC 62368-1/EN 62368-1/UL 62368-1.

Hot Surfaces

• External metal parts of this equipment are extremely hot. Before touching the equipment, you must take special precautions to protect your hands and body from serious injury.

Maintenance and Fuses

• To protect against the risk of fire, only replace the fuse with one that has the same type and rating.

• It is recommended to incorporate a readily accessible disconnect device into the building installation wiring. Importantly, ensure the power supply is disconnected before performing any maintenance.

• This equipment is designed to connect the earthed conductor of the D.C supply circuit to the equipment’s earthing conductor.

Restricted Access Locations

• This equipment is intended to be used in Restricted Access Locations, such as a computer room, with access limited to service personnel or users who have been instructed on how to handle the metal chassis of equipment that is very hot. The location should only be accessible with a key or through a security system.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD MOXA PT-G510-4GTX4GSFP-PHR (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.