What items are included in the package for the MOXA PT-G510-8GSFP-PHR?

The MOXA PT-G510-8GSFP-PHR industrial DIN-rail switch is shipped with the following items:

• PT-G510 switch

• DIN-rail kit

• Protective caps on SFP ports and USB Storage ports

• RJ45 to DB9 Cable

• Quick installation guide (printed)

• Substance Disclosure Table

• Product Certificate of Quality Inspection

• Product Notices

• Warranty card


What are the default network settings for the MOXA PT-G510-8GSFP-PHR?

The default network settings are as follows:

• Default IP address: 192.168.127.253

• Default Subnet Mask: 255.255.255.0

• Default Usernames: admin, user

• Default Password: moxa


Can you describe the front panel layout of the MOXA PT-G510-8GSFP-PHR?

The front panel of the MOXA PT-G510-8GSFP-PHR features the following components:

• System LED Indicators at the top.

• A Console Port (RJ45).

• A USB Storage Port.

• 100/1000Base SFP A/B Port (Ports 7 and 8).

• 100/1000Base SFP Slots (Ports 1 through 6).

• A Power Connector and Relay connector at the bottom.


What do the LED indicators on the MOXA PT-G510-8GSFP-PHR mean?

The function of each LED on the front panel is described in the tables below:

System LEDs

LED Color State Description
State (S) Green On When system has passed power-on self-test (POST) and is ready to run.
Blinking • When the reset button is pressed for 5 seconds to reset to factory default.
• When a USB drive is detected.
• Web locator is on.
Off N/A
FAULT (F) Red On • Switch initialization failure.
• When the power-on self-test (POST) fails.
On • USB detected/operation failed.
• Network loop detected when loop protection is enabled.
• Relay NC is on.
• The ring port connection is not valid.
Blinking • EEPROM information error.
• Web locator is on.
Off The system is operating normally, and no user-configured event is triggered.
Power1 (P1) Amber On Power is being supplied to power input P1.
Off Power is not being supplied to power input P1.
Power2 (P2) Amber On Power is being supplied to power input P2.
Off Power is not being supplied to power input P2.
MSTR/HEAD (M/H) Green On • EEPROM information error.
• When the switch is Master/Head/Root of Turbo Ring/Turbo Chain/Fast RSTP.
• When the switch is MRM of MRP and the MRP ring is closed.
Blinking • When the switch is Ring Master/Head of Turbo Ring/Turbo Chain, and the Turbo Ring/Turbo Chain is broken.
• When the switch is MRM of MRP and the MRP ring is broken.
• Web locator is on.
Off When the switch is not the Master/Head/Root of this Turbo Ring/Turbo Chain/Fast RSTP.
CPRL/TAIL (C/T) Green On • When the switch enables the coupling function to form a back-up path.
• When the switch is tail of Turbo Chain.
Blinking • When the switch is enabled Turbo Chain and Turbo Chain is broken.
• Web locator on.
Off When the switch disables the coupling or tail role of Turbo Chain.
SYNC Amber On The PTP function is enabled and is in the free-run state.
Blinking The PTP function is enabled, and switch is in syncing state.
Green On The PTP function has successfully converged
Off The PTP function is off.

Redundancy LEDs

LED Color State Description
PRP Green On PRP mode is enabled.
Off PRP mode is disabled.
HSR Green On HSR mode is enabled.
Off HSR mode is disabled.
Coupling Green On PRP/HSR Coupling mode is enabled.
Off PRP/HSR Coupling mode is disabled.

Port LEDs (10M/100M/1000M Copper)

LED Type Color State Description
10M/100M/1000M Copper Green On When the port is active, and link is on 1000 Mbps.
Blinking When the port’s data is being transmitted at 1000 Mbps.
Off When the port is inactive, or link is down.
Amber On When the port is active, and link is on 100/10 Mbps.
Blinking When the port’s data is being transmitted at 100/10 Mbps.
Off When the port is inactive or the link is down.

Port LEDs (100M/1000M SPF)

LED Type Color State Description
100M/1000M SPF Green On When the port is active, and the link is on 1000 Mbps.
Blinking When data is being transmitted at 1000 Mbps.
Off When the port is inactive or the link is down.
Amber On When the port is active and the link is on 100 Mbps.
Blinking When data is being transmitted at 100 Mbps.
Off When the port is inactive, or link is down.

How do I mount the MOXA PT-G510-8GSFP-PHR onto a DIN rail?

The DIN-rail mounting kit is fixed to the back panel of the PT-G510 by default. To install the switch, mount it on a corrosion-free mounting rail that meets the EN 60715 standard.

STEP 1: Insert the upper lip of the DIN rail into the DIN-rail mounting kit.

STEP 2: Press the PT-G510 towards the DIN rail until it snaps into place.


How do I remove the MOXA PT-G510-8GSFP-PHR from a DIN rail?

STEP 1: Pull down the latch on the mounting kit with a screwdriver.

STEP 2 & 3: Slightly pull the PT-G510 forward and lift to remove it from the DIN rail.


How do I connect the power inputs on the MOXA PT-G510-8GSFP-PHR?

Before connecting the switch to the AC or DC power inputs, make sure the power source voltage is stable.

The PT-G510 Series switches support various types of power supplies:

• WV models come with two 24 to 48 VDC power inputs.

• HV models come with two 110 to 220 VDC/VAC power inputs.

For HV Models:

STEP 1: Insert the positive/negative DC or line/neutral AC wires into the V+/V- or L/N terminals, respectively.

STEP 2: Use a flat-blade screwdriver to tighten the wire-clamps on the front of the terminal block connector to fasten the wires.

STEP 3: Insert the plastic terminal block connector prongs into the terminal block receptor.

For WV Models:

STEP 1: Insert the positive/negative DC wires into the V+/V- terminals, respectively.

STEP 2: Use a flat-blade screwdriver to tighten the wire-clamps on the front of the terminal block connector to fasten the wires.

STEP 3: Insert the plastic terminal block connector prongs into the terminal block receptor.

NOTE: If you intend to only use one power input, be sure to disconnect the other power input (unplug the power cord or disconnect the power input from the L and N contacts). Only one power input LED will be on.


What are the recommendations for wiring the dual power inputs on the MOXA PT-G510-8GSFP-PHR?

If you intend to use more than 220 VAC/VDC (combined total) to power the dual power inputs, you must consider the following scenarios. These recommendations apply even if the PWR1 and PWR2 configurations are reversed.

PWR1 PWR2 Recommendations
220 VAC 220 VDC We do not recommend using this combination for the dual power inputs because the AC voltage difference between PWR1 and PWR2 exceeds 264 VAC RMS. This can damage the power board. If you need this type of wiring, use our MDS-G4000 Series.
220 VAC 110 VDC
220 VAC 220 VAC Use a qualified digital multimeter (e.g., a Fluke 85 V or equivalent) to measure and ensure the AC voltage difference between PWR1 and PWR2 is within the 264 VAC. If the difference in AC voltage exceeds 264 VAC RMS, an isolation transformer (220 V to 110 V; minimum 50 VA) must be used between the PT-G510 Series and the AC power source to avoid damage from power surges.
How to measure the voltage difference: You will need to measure the voltage difference between 4 pairs of wires, as listed below:
[L1-N1], [L1-N2], [L1-L2]
[N1-N2], [N1-L2], [N2-L2]
220 VAC 110 VAC
220 VDC 220 VDC
220 VDC 110 VDC Use an isolation transformer (220 V to 110 V; minimum 50 VA) between the PT-G510 Series and the Uninterruptible Power Supply (UPS) source to avoid damage from power surges.

How do I wire the relay contact on the MOXA PT-G510-8GSFP-PHR?

The relay contact of the 3-pin terminal block connector is used to detect user-configured events. The module provides normally open (NO) and normally closed (NC) circuits. Two wires are attached to the relay pins for these options.

For pin definitions, refer to the table below:

Relay connection Power on state Event trigger
NO and COM Closed circuit Open circuit
NC and COM Open Circuit Closed circuit

NOTE: When wiring the relay contact, DI, and power inputs, we suggest using the cable type AWG (American Wire Gauge) 16-24 (1.31-0.205 mm²) and the corresponding pin type cable terminals. The connector must be able to withstand torque at maximum 5 pound-inches. The rated temperature of wiring should be at least 105°C.


How do I properly ground the MOXA PT-G510-8GSFP-PHR?

Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the ground screw (M4) to the grounding surface prior to connecting devices. The grounding screw is located next to the power and relay terminal block connector.

NOTE: Using a shielded cable achieves better electromagnetic resistance. Use a green-yellow grounding cable with a wire size AWG 18 or higher to ground this product to earth.


How do I connect to the RJ45 console port on the MOXA PT-G510-8GSFP-PHR?

The PT-G510 has one RJ45 console port (RS-232) on the front panel. Use an RJ45-based cable to connect the console port to your PC’s COM port. You can then use a console terminal program to access the switch with a baudrate of 115200. The pin definitions for the console port are as follows:

Pin Signal
1 –
2 RTS
3 –
4 TxD
5 RxD
6 GND
7 CTS
8 –

How do I use the USB storage port on the MOXA PT-G510-8GSFP-PHR?

The USB storage port is on the front panel of the PT-G510 switch and has a type A connector. Use Moxa’s ABC-02-USB automatic backup configurator to connect to the USB port to perform configuration backup, firmware upgrade, or system log file backup. The pinout assignments are as follows:

Pin Description
1 VCC (+5V)
2 D- (Data-)
3 D+ (Data+)
4 GND (Ground)

How can I reset the MOXA PT-G510-8GSFP-PHR to its factory default settings?

Use a pointed object, such as a straightened paper clip or toothpick, to depress the Reset button. When you do so, the STATE LED will start to blink about once per second. Continue to hold the button until the STATE LED begins blinking more rapidly; this indicates that the button has been depressed for five seconds. You can then release the Reset button to load factory default settings.

NOTE: DO NOT power off the switch when loading default settings. When the ABC-02 is plugged in, you cannot reset to factory default by pressing the reset button.


How do I back up configuration and log files on the MOXA PT-G510-8GSFP-PHR?

When the ABC-02-USB is connected to the PT-G510 switch, the reset button allows for a quick backup of configuration and event logs to the ABC-02-USB. Press the reset button to start backing up the current system configuration files and event logs to the ABC-02-USB.


What are the key operational specifications for the MOXA PT-G510-8GSFP-PHR?

Ethernet Interface

• 100/1000Base SFP slots: 10

Power Parameters

• Rated Input Voltage:
– PT-G510-PHR-HV Models: 110 to 220 VAC, 50/60 Hz, 110 to 220 VDC
– PT-G510-PRP-WV Models: 24 to 48 VDC
Note: Both -HV and -WV models support dual power inputs with a single power module.

• Rated Input Current:
– PT-G510-PHR-HV Models: 0.5 A @ 110 to 220 VAC
– PT-G510-PHR-HV Models: 0.3 A @ 110 to 220 VDC
– PT-G510-PHR-WV Models: 1.1 A @ 24 to 48 VDC

Power Consumption (Max.)

• PT-G510-8GSFP-PHR-HV Models:
– 110 VAC: 23.54 W
– 220 VAC: 24.57 W
– 110 VDC: 23.485 W
– 220 VDC: 23.88 W

• PT-G510-8GSFP-PHR-WV Models:
– 24 VDC: 21.868 W
– 48 VDC: 22.646 W

Environmental Limits

• Operating Temperature:
– -40 to 75°C (-40 to 167°F)
– -40 to 85°C (-40 to 185°F) for 16 hrs based on 85°C test in accordance with IEC 60068-2-2.

• Storage Temperature (Package Included): -40 to 85°C (-40 to 185°F)

• Ambient Relative Humidity: 5 to 95% (non-condensing)


What are the key safety warnings I should be aware of when handling the MOXA PT-G510-8GSFP-PHR?

Safety First!

• Be sure to disconnect the power cord before installing and/or wiring your Ethernet Switch. Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size. If the current goes above the maximum ratings, the wiring could overheat, which can cause serious damage to your equipment.

Warnings

• Use only a Laser Class 1 optical transceiver with this device.

• This equipment is intended to be supplied by an external power source (UL listed/ IEC 60950-1/ IEC 62368-1) with output rating 24 to 48 VDC, 1.1 A (minimum) or 110 to 220 VDC, 0.3 A (minimum), and an ambient temperature of 75°C (minimum).

• Do not disconnect modules or wires unless power has been switched off or the area is known to be non-hazardous. The device may only be connected to the supply voltage shown on the type plate. The device is designed for operation with an isolated power supply.

• External metal parts of this equipment are extremely hot. Before touching the equipment, you must take special precautions to protect your hands and body from serious injury.

Restricted Access Locations

• This equipment is intended to be used in Restricted Access Locations, such as a computer room, with access limited to service personnel or users who have been instructed on how to handle the metal chassis of equipment that is very hot. The location should only be accessible with a key or through a security system.

Attention

• To protect against the risk of fire, only replace the fuse with one that has the same type and rating.

• It is recommended to incorporate a readily accessible disconnect device into the building installation wiring. Importantly, ensure the power supply is disconnected before performing any maintenance.

• This equipment is designed to connect the earthed conductor of the D.C supply circuit to the equipment’s earthing conductor.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD MOXA PT-G510-8GSFP-PHR (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.