What are the features and benefits of the DURASTAR DRF2TA3624ASTNJB5 air handler?

The DURASTAR DRF2TA3624ASTNJB5 air handler includes the following features and benefits:

• Front or Bottom Return with aluminum tube and fin coil

• TXV for cooling or heat pump operation

• Wall-hanging brackets

• Built in Filter Rack

• Molex Plug Connections for field installed heater kits

• Dual Voltage Direct Drive Blower with multi-speed motor

• Thermoplastic Drain Pan with bottom primary and secondary connections

• Optional Decorative Grill for front return applications

• Optional Factory Installed Condensate Float Switch which shuts off the outdoor unit in the event the condensate pan becomes clogged

• Cabinet air leakage less than 2% at 1 inch H2O when tested in accordance with ASHRAE Standard 193

• Can be field wired for single or two stage applications


What standard equipment is included with the DURASTAR DRF2TA3624ASTNJB5?

The standard equipment for the DURASTAR DRF2TA3624ASTNJB5 includes:

• Exclusive Incoloy sheath type electric heating elements

• Field convertible air supply

• Durable framed cleanable air filter

• Indoor coil design provides low air side pressure drop, high performance and compact size

• PVC condensate elbow is standard on all coils

• All indoor coils have aluminum tubing and aluminum fins

• Molded polymer corrosion resistant condensate drain pan

• Supply and return duct flanges

• High and low voltage connection points inside cabinet

• Concentric knockouts provided for power connection with hole size up to 2 inches [51 mm] for 1 1/2 inch [38mm] conduit

• Internal checked TX valves for quiet refrigerant metering

• Front refrigerant and drain connection


How is the model number for the DURASTAR DRF2TA series identified?

The model number for the DURASTAR DRF2TA series is broken down as follows:

DR F 2 T A 24 21 A S T N J B 0 F
Brand Product Category Stages Of Airflow Motor Type Refrigerant Capacity Width Major Series Efficiency Metering Coil Series Voltage Disconnect Factory Heat Option Code
DR – Durastar F – Front Return 2 – 2-Stage T – Constant Torque A – R-410A 24 – 24,000 [7.03 kW]
36 – 36,000 [10.55 kW]
21 – 21″
24 – 24.5″
A – 1st Design S – Standard T – TXV N – N Coil J – 208-240/1/60 B – Breaker
N – None
0 – No Heat
3 – 3 kW
5 – 5 kW
8 – 8 kW
1 – 10 kW
F – Float Switch

[] Designates Metric Conversions


What are the dimensions and weight of the DURASTAR DRF2TA3624ASTNJB5 model?

Model (A) Unit Width In. [mm] (B) Unit Height In. [mm] (C) Unit Depth In. [mm] (D) Return Air Opening Width In. [mm] (E) Return Air Opening Height In. [mm] Filter Size in. x in. x in. [mm x mm x mm] Air Flow CFM (Nom.) [L/s] Unit Weight/Shipping Weight (Lbs.) [kg]
Low High
DRF2TA3624 24 [609.6] 36 [914.4] 21 [533.4] 23 [584.2] 21 3/8 [542.9] 20 X 25 X 1 [508 X 635 X 25.4] 1000 [472] 1200 [566] 95 [43] x 105 [48]

[] Designates Metric Conversions


What are the airflow operating limits for the DURASTAR DRF2TA3624ASTNJB5?

Airflow performance data is based on cooling performance with a coil and no filter in place. For optimum blower performance, operate the unit in the .3 [8 mm] to .7 inches [18 mm] W.C. external static range. Units with coils should be applied with a minimum of .1 inch [3 mm] W.C. external static range.

Airflow Operating Limits (Model Cabinet Size 24)
24
Cooling BTUH x 1,000 -36
Cooling Tons Nominal 3
Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (37.5 CFM [18 L/s]/1,000 BTUH) (450 CFM [212 L/s]/Ton Nominal) 1350 [637]
Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (33.3 CFM [16 L/s]/1,000 BTUH) (400 CFM [189 L/s]/Ton Nominal) 1200 [566]
Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (30.0 CFM [14 L/s]/1,255 BTUH) (360 CFM [170 L/s]/Ton Nominal) 1080 [510]
Maximum kW Electric Heating & Minimum Electric Heat CFM [L/s] 10
976 [461]
Maximum Electric Heat Rise °F [°C] 44 [7]

[] Designates Metric Conversions


What is the airflow performance data for the DURASTAR DRF2TA3624ASTNJB5 (3 Tons model) at different motor speeds and external static pressures?

115V/208V/240V Airflow Performance Data—DRF2TA (Constant Torque (ECM) Motor)
Model/Nominal Cooling Capacity Air-Flow Range (Max/Min) CFM Manufacturer Recommended Blower Size/Motor HP # of Speeds Motor Speed From Factory Motor Speed CFM Dry Delivery/filter/heaters/RPM/Watts
External Static Pressure-Inches W.C.
0.1 0.2 0.3 0.4 0.5 0.6 0.7
DRF2TA36
3 Tons
1306/1040 10×8 1/2 Hp
2 speed
dual voltage
5 4 CFM 808 750 698 633 568 504 448
RPM 615 665 713 780 842 884 929
Watts 91.4 97.7 103.9 112.4 120.2 125.5 131.2
5 CFM 1241 1201 1148 1109 1065 1028 983
RPM 847 880 905 916 955 991 1035
Watts 246.3 254.9 260.9 263.8 273.1 282.5 293.3

NOTE: All DRF2TA air-handlers have 5 speed constant torque motors.

Speed tap 1 is for continuous fan. Speed tap 2 (low static) and speed tap 3 (high static) are for lower tonnage (1.5 or 2.5 tons). Speed tap 4 (low static) and speed tap 5 (high static) are for higher tonnage (2.0 or 3.0 tons).

DRF2TA air handlers are always shipped from factory at speed tap 5.

The low static speed tap 2 (lower tonnage) and 4 (higher tonnage) are for external static pressures below 0.5″ WC. The high static speed tap 3 (lower tonnage) and 5 (higher tonnage) are used for external static exceeding 0.5″ WC. Move the blue wire to the appropriate speed tap on the motor terminal block as required by the application needs.

The airflow for continuous fan (speed tap 1) is always set at 50% of the speed tap 4.

• The above airflow table lists the airflow information for air handlers with maximum heater allowed for each model.


What are the electrical specifications for the blower motor only on the DURASTAR DRF2TA3624ASTNJB5?

Electrical Data—Blower Motor Only—No Electric Heat
Model/Nominal Cooling Tons Voltage Phase Hertz HP [W] RPM Speeds Circuit Amps. Minimum Circuit Ampacity Maximum Circuit Protector
DRF2TA3624 208/230 1 60 1/2 [373] 300-1100 4 2.7 4 15

*Blower motors are all single phase motors.


What are the electrical data specifications when using an electric heat kit with the DURASTAR DRF2TA3624ASTNJB5?

Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the table below is recommended for all auxiliary heating requirements.

Electrical Data—with Electric Heat for DRF2TA3624
Cooling Capacity Tons Model No. Heater kW PH/Hz No. Elements – kW Per (208/240V) Type Supply Circuit Circuit Amps. Motor Ampacity Minimum Circuit Ampacity Maximum Circuit Protection
DRF2TA3624 RXHJ-21B/T03J 2.25/3.0 1/60 1-3.0 Single 10.8/12.5 1.9 16/18 20/20
RXHJ-21B/T05J 3.6/4.8 1/60 1-4.8 Single 17.3/20.0 1.9 0.9 25/30
RXHJ-21B/T08J 5.4/7.2 1/60 2-3.6 Single 26.0/30.0 1.9 35/40 35/40
RXHJ-21B/T10J 7.2/9.6 1/60 2-4.8 Single 34.6/40.0 1.9 0.9 50/60

• Electric heater BTUH – (heater watts + motor watts) x 3.414 (see airflow table for motor watts.)

• J voltage (230V) single phase air handler is designed to be used with single or three phase.

• Supply circuit protective devices may be fused or “HACR” type circuit breakers.

• If non-standard fuse size is specified, use next size larger standard fuse size. Without the heater, bring only two leads to terminal block, cap, insulate and fully secure the third lead.

• Largest motor load is included in single circuit or circuit 1 of multiple circuits.

• Do not use 480 volts electrical heaters on 230 volts air handler.


What are the electrical power wiring and grounding requirements for the DURASTAR DRF2TA3624ASTNJB5?

• Field wiring must comply with the National Electrical Code.

• This product must be sufficiently grounded in accordance with (C.E.C. in Canada) and any applicable local ordinance. National Electrical Code (C.E.C. in Canada) and any applicable.

• Supply wiring must be 75°C minimum copper conductors only. Local ordinance.

• See electrical data for product Ampacity rating and Circuit.

• A grounding lug is provided. Protector requirement.


What optional accessories, kits, and parts are available for the DURASTAR DRF2TA3624ASTNJB5?

The following accessories, kits, and parts are available for your air handler:

• Drain Pan Over Flow Switch RXHK-A01: This is used to detect condensate drain blockage and will shut down the outdoor unit in order to prevent structural damage to the surrounding structures of the air handler.

• Bottom Return Conversion Kit RXHK-B02: This kit is used to divert the return air from the factory standard front return to a bottom return.

• Louvered Cabinet Grill RXHK-C02: This is used as a decorative grill which covers the return air opening of the front return air handler.

• Decorative Wall Grill RXHK-D01 or RXHK-D02: This is used in applications where the air handler is installed in a closet or interior wall and allows adequate return air back to the unit.


In what configuration can the DURASTAR DRF2TA3624ASTNJB5 be installed?

All DURASTAR DRF2TA3624ASTNJB5 units are configured for vertical upflow. The units cannot be installed in any other configuration.


What is the required maintenance clearance for the DURASTAR DRF2TA3624ASTNJB5?

A clearance of 24 inches (610 mm) is required in front of the DURASTAR DRF2TA3624ASTNJB5 for filter and coil maintenance.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD DURASTAR DRF2TA3624ASTNJB5 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.