What are the key features and benefits of the DURASTAR DRF2TA2421ASTNJB1 air handler?
The DURASTAR DRF2TA2421ASTNJB1 air handler includes the following features and benefits:
• Front or Bottom Return with aluminum tube and fin coil
• TXV for cooling or heat pump operation
• Wall-hanging brackets
• Built in Filter Rack
• Molex Plug Connections for field installed heater kits
• Dual Voltage Direct Drive Blower with multi-speed motor
• Thermoplastic Drain Pan with bottom primary and secondary connections
• Optional Decorative Grill for front return applications
• Optional Factory Installed Condensate Float Switch which shuts off the outdoor unit in the event the condensate pan becomes clogged
• Cabinet air leakage less than 2% at 1 inch H2O when tested in accordance with ASHRAE Standard 193
• Can be field wired for single or two stage applications
How is the model number for the DURASTAR DRF2TA2421ASTNJB1 decoded?
The model number provides specific details about the unit’s configuration. Here is a breakdown:
| DR | F | 2 | T | A | 24 | 21 | A | S | T | N | J | B | 0 | F |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Brand | Product Category | Stages of Airflow | Motor Type | Refrigerant | Capacity | Width | Major Series | Efficiency | Metering | Coil Series | Voltage | Disconnect | Factory Heat | Option Code |
| DR – Durastar | F – Front Return | 2 – 2-Stage | T – Constant Torque | A – R-410A | 24 – 24,000 [7.03 kW] 36 – 36,000 [10.55 kW] |
21 – 21″ 24 – 24.5″ |
A – 1st Design | S – Standard | T – TXV | N – N Coil | J – 208-240/1/60 | B – Breaker N – None |
0 – No Heat 3 – 3 kW 5 – 5 kW 8 – 8 kW 1 – 10 kW |
F – Float Switch |
[] Designates Metric Conversions
What standard equipment is included with the DURASTAR DRF2TA2421ASTNJB1?
The standard equipment for the DURASTAR DRF2TA2421ASTNJB1 includes:
• Exclusive Incoloy sheath type electric heating elements
• Field convertible air supply
• Durable framed cleanable air filter
• Indoor coil design provides low air side pressure drop, high performance and compact size
• PVC condensate elbow is standard on all coils
• All indoor coils have aluminum tubing and aluminum fins
• Molded polymer corrosion resistant condensate drain pan
• Supply and return duct flanges
• High and low voltage connection points inside cabinet
• Concentric knockouts provided for power connection with hole size up to 2 inches [51 mm] for 1 1/2 inch [38mm] conduit
• Internal checked TX valves for quiet refrigerant metering
• Front refrigerant and drain connection
What are the return air opening dimensions for the cabinet of the DURASTAR DRF2TA2421ASTNJB1?
The return air opening dimensions for the DURASTAR DRF2TA2421ASTNJB1, which has a 21-inch cabinet size, are as follows:
| Model Cabinet Size | Return Air Opening Width (Inches) | Return Air Opening Depth/Length (Inches) |
|---|---|---|
| 17 | 15 7/8 | 19 3/4 |
| 21 | 19 3/8 | 19 3/4 |
| 24 | 22 7/8 | 19 3/4 |
What are the unit dimensions, weight, and filter size for the DURASTAR DRF2TA2421ASTNJB1?
The dimensions, weights, and specifications for the DURASTAR DRF2TA2421ASTNJB1 are detailed below.
| Model | (A) Unit Width In. [mm] | (B) Unit Height In. [mm] | (C) Unit Depth In. [mm] | (D) Return Air Opening Width In. [mm] | (E) Return Air Opening Height In. [mm] | Filter Size in. x in. x in. [mm x mm x mm] | Air Flow CFM (Nom.) [L/s] Low/High | Unit Weight/Shipping Weight (Lbs.) [kg] |
|---|---|---|---|---|---|---|---|---|
| DRF2TA2421 | 21 1/2 [546.1] | 36 [914.4] | 17 [431.8] | 20 [508.0] | 17 7/16 [442.9] | 20 X 20 X 1 [508 X 508 X 25.4] | 600 [283] / 800 [378] | 95 [43] x 105 [48] |
What are the airflow operating limits for the DURASTAR DRF2TA2421ASTNJB1?
For optimum blower performance, operate the unit in the .3 [8 mm] to .7 inches [18 mm] W.C. external static range. Units with coils should be applied with a minimum of .1 inch [3 mm] W.C. external static range. The operating limits for the DURASTAR DRF2TA2421ASTNJB1, which has a 21-inch cabinet, are as follows:
| Airflow Operating Limits | Model Cabinet Size 21 |
|---|---|
| Cooling BTUH x 1,000 | -24 |
| Cooling Tons Nominal | 2 |
| Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (37.5 CFM [18 L/s]/1,000 BTUH) (450 CFM [212 L/s]/Ton Nominal) | 900 [425] |
| Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (33.3 CFM [16 L/s]/1,000 BTUH) (400 CFM [189 L/s]/Ton Nominal) | 800 [378] |
| Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (30.0 CFM [14 L/s]/1,255 BTUH) (360 CFM [170 L/s]/Ton Nominal) | 720 [340] |
| Maximum kW Electric Heating & Minimum Electric Heat CFM [L/s] | 10, 690 [326] |
| Maximum Electric Heat Rise °F [°C] | 44 [7] |
What is the airflow performance data for the DURASTAR DRF2TA2421ASTNJB1?
The airflow performance data for the DURASTAR DRF2TA2421ASTNJB1 (2 Ton model) at various external static pressures is detailed in the table below. This data is for dry delivery with filter and heaters installed.
| Model / Nominal Cooling Capacity | Air-Flow Range (Max/Min) CFM | Motor Speed From Factory | Motor Speed | CFM Dry Delivery/filter/heaters/RPM/Watts External Static Pressure-Inches W.C. |
||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | ||||
| DRF2TA24 (2 Tons) 973/733 10×6 1/3 Hp 2 speed dual voltage |
5 | 4 | CFM | 654 | 616 | 581 | 542 | 503 | 463 | 399 |
| RPM | 694 | 736 | 777 | 818 | 858 | 899 | 971 | |||
| Watts | 76.4 | 80.1 | 83.7 | 87.6 | 91.3 | 95.1 | 101.6 | |||
| DRF2TA24 (2 Tons) 973/733 10×6 1/3 Hp 2 speed dual voltage |
5 | 5 | CFM | 887 | 858 | 830 | 802 | 771 | 743 | 717 |
| RPM | 876 | 914 | 945 | 976 | 1014 | 1044 | 1070 | |||
| Watts | 156 | 161.8 | 166.8 | 171.5 | 177.5 | 182.3 | 186.2 | |||
How are the motor speed taps configured on the DURASTAR DRF2TA2421ASTNJB1?
The DURASTAR DRF2TA2421ASTNJB1 air handler has a 5-speed constant torque motor. The speed taps are configured for different applications:
• Speed tap 1 is for continuous fan.
• Speed tap 2 (low static) and speed tap 3 (high static) are for lower tonnage models (1.5 or 2.5 tons).
• Speed tap 4 (low static) and speed tap 5 (high static) are for higher tonnage models (2.0 or 3.0 tons).
The air handler is always shipped from the factory set to speed tap 5.
To adjust the speed, move the blue wire to the appropriate speed tap on the motor terminal block based on your application’s needs:
• Use the low static speed tap (2 or 4) for external static pressures below 0.5″ WC.
• Use the high static speed tap (3 or 5) for external static pressures exceeding 0.5″ WC.
The airflow for the continuous fan (speed tap 1) is always set at 50% of the speed tap 4 airflow.
What are the blower motor electrical specifications for the DURASTAR DRF2TA2421ASTNJB1 without an electric heat kit installed?
The electrical data for the blower motor only (no electric heat) for the DURASTAR DRF2TA2421ASTNJB1 is as follows:
| Model/Nominal Cooling Tons | Voltage | Phase | Hertz | HP [W] | RPM | Speeds | Circuit Amps. | Minimum Circuit Ampacity | Maximum Circuit Protector |
|---|---|---|---|---|---|---|---|---|---|
| DRF2TA2421 | 208/230 | 1 | 60 | 1/3 [249] | 300-1100 | 4 | 1.9 | 3 | 15 |
*Blower motors are all single phase motors.
What are the electrical specifications for the DURASTAR DRF2TA2421ASTNJB1 when using a compatible electric heat kit?
When installing a U.L. Listed original equipment manufacturer provided heater kit, refer to the following electrical data. The heater kits compatible with the DURASTAR DRF2TA2421ASTNJB1 (21-inch cabinet) are prefixed with RXHJ-21B.
| Model No. | Heater kW | PH/Hz | No. Elements – kW Per | (208/240V) Type Supply Circuit | Circuit Amps. | Motor Ampacity | Minimum Circuit Ampacity | Maximum Circuit Protection |
|---|---|---|---|---|---|---|---|---|
| RXHJ-21B/T03J | 2.25/3.0 | 1/60 | 1-3.0 | Single | 10.8/12.5 | 1.9 | 16/18 | 20/20 |
| RXHJ-21B/T05J | 3.6/4.8 | 1/60 | 1-4.8 | Single | 17.3/20.0 | 1.9 | 0.9 | 25/30 |
| RXHJ-21B/T08J | 5.4/7.2 | 1/60 | 2-3.6 | Single | 26.0/30.0 | 1.9 | 35/40 | 35/40 |
| RXHJ-21B/T10J | 7.2/9.6 | 1/60 | 2-4.8 | Single | 34.6/40.0 | 1.9 | 0.9 | 50/60 |
• Electric heater BTUH = (heater watts + motor watts) x 3.414.
• Supply circuit protective devices may be fused or “HACR” type circuit breakers.
• If a non-standard fuse size is specified, use the next size larger standard fuse size.
• Largest motor load is included in single circuit or circuit 1 of multiple circuits.
What are the electrical wiring and grounding requirements for the DURASTAR DRF2TA2421ASTNJB1?
Follow these guidelines for electrical power wiring and grounding:
• Field wiring must comply with the National Electrical Code (C.E.C. in Canada) and any applicable local ordinances.
• This product must be sufficiently grounded in accordance with the National Electrical Code (C.E.C. in Canada) and any applicable local ordinances.
• Supply wiring must be 75°C minimum copper conductors only.
• See electrical data tables for the product’s Ampacity rating and Circuit Protector requirement.
• A grounding lug is provided.
What is the purpose of the Drain Pan Over Flow Switch Kit (RXHK-A01) for the DURASTAR DRF2TA2421ASTNJB1?
The Drain Pan Over Flow Switch Kit RXHK-A01 is an accessory used to detect a condensate drain blockage. If a blockage is detected, the switch will shut down the outdoor unit to prevent structural damage to the surrounding areas of the air handler.
What is the purpose of the Bottom Return Conversion Kit for the DURASTAR DRF2TA2421ASTNJB1 and which kit should be used?
The Bottom Return Conversion Kit (RXHK-series) is used to divert the return air from the factory standard front return to a bottom return configuration. For the DURASTAR DRF2TA2421ASTNJB1, you should use the kit corresponding to the DRF2TA-FR24 indoor unit model.
| Accessory Number | Indoor Unit |
|---|---|
| RXHK-B01 | DRF2TA-FR18 |
| DRF2TA-FR24 | |
| RF1T-FR24 | |
| RXHK-B02 | DRF2TA-FR30 |
| DRF2TA-FR36 | |
| RF1T-FR36 |
What is the purpose of the Louvered Cabinet Grill Kit for the DURASTAR DRF2TA2421ASTNJB1 and which kit should be used?
The Louvered Cabinet Grill Kit (RXHK-series) is a decorative grill that covers the return air opening of the front return air handler. For the DURASTAR DRF2TA2421ASTNJB1, you should use the kit corresponding to the DRF2TA-FR24 indoor unit model.
| Accessory Number | Indoor Unit |
|---|---|
| RXHK-C01 | DRF2TA-FR18 |
| DRF2TA-FR24 | |
| RF1T-FR24 | |
| RXHK-C02 | DRF2TA-FR30 |
| DRF2TA-FR36 | |
| RF1T-FR36 |
When should the Decorative Wall Grill (RXHK-D01 or RXHK-D02) be used with the DURASTAR DRF2TA2421ASTNJB1?
The Decorative Wall Grill accessory, model RXHK-D01 or RXHK-D02, is used in applications where the DURASTAR DRF2TA2421ASTNJB1 air handler is installed in a closet or interior wall. This grill allows for adequate return air to flow back to the unit through the wall.