What are the key features and benefits of the DURASTAR DRF2TA3624ASTNJB3F air handler?

The DURASTAR DRF2TA3624ASTNJB3F air handler includes a variety of features for performance and installation flexibility.

Core Features:

Return Air Configuration: Supports Front or Bottom Return with an aluminum tube and fin coil.

Metering Device: Equipped with a Thermal Expansion Valve (TXV) for cooling or heat pump operation.

Installation: Comes with wall-hanging brackets and a built-in filter rack.

Heater Kits: Features Molex Plug Connections for field-installed heater kits.

Blower Motor: A Dual Voltage Direct Drive Blower with a multi-speed Constant Torque Motor (ECM).

Drain Pan: Includes a Thermoplastic Drain Pan with bottom primary and secondary connections.

Cabinet: Cabinet air leakage is less than 2% at 1 inch H2O when tested in accordance with ASHRAE Standard 193.

Wiring: Can be field wired for single or two-stage applications.

Standard Equipment:

• Exclusive Incoloy sheath type electric heating elements.

• Field convertible air supply.

• Durable framed cleanable air filter.

• Indoor coil design provides low air side pressure drop, high performance, and compact size.

• PVC condensate elbow is standard on all coils.

• All indoor coils feature aluminum tubing and aluminum fins.

• Molded polymer corrosion-resistant condensate drain pan.

• Supply and return duct flanges.

• High and low voltage connection points located inside the cabinet.

• Concentric knockouts for power connection.

• Internal checked TX valves for quiet refrigerant metering.

• Front refrigerant and drain connection.


How is the model number for the DURASTAR DRF2TA3624ASTNJB3F series decoded?

The model number provides specific details about the air handler’s configuration. Here is a breakdown:

Code Category Description
DR Brand DR – Durastar
F Product Category F – Front Return
2 Stages of Airflow 2 – 2-Stage
T Motor Type T – Constant Torque
A Refrigerant A – R-410A
36 Capacity 36 – 36,000 [10.55 kW]
24 Width 24 – 24.5″
A Major Series A – 1st Design
S Efficiency S – Standard
T Metering T – TXV
N Coil Series N – N Coil
J Voltage J – 208-240/1/60
B Disconnect B – Breaker
3 Factory Heat 0 – No Heat, 3 – 3 kW, 5 – 5 kW, 8 – 8 kW, 1 – 10 kW
F Option Code F – Float Switch

What are the physical dimensions, filter size, and weight of the DURASTAR DRF2TA3624ASTNJB3F model?

The following table provides the dimensions, weights, and other specifications for the DURASTAR DRF2TA3624ASTNJB3F model.

Model (A) Unit Width In. [mm] (B) Unit Height In. [mm] (C) Unit Depth In. [mm] (D) Return Air Opening Width In. [mm] (E) Return Air Opening Height In. [mm] Filter Size in. x in. x in. [mm x mm x mm] Air Flow CFM (Nom.) [L/s] Low Air Flow CFM (Nom.) [L/s] High Unit Weight/Shipping Weight (Lbs.) [kg]
DRF2TA3624 24 [609.6] 36 [914.4] 21 [533.4] 23 [584.2] 213/8 [542.9] 20 X 25 X 1 [508 X 635 X 25.4] 1000 [472] 1200 [566] 95 [43] x 105 [48]

What are the operating limits for the DURASTAR DRF2TA3624ASTNJB3F air handler?

The airflow operating limits for the DURASTAR DRF2TA3624ASTNJB3F, which has a model cabinet size of 24, are detailed in the table below. For optimal blower performance, operate the unit in the .3 [8 mm] to .7 inches [18 mm] W.C. external static range.

Airflow Operating Limits Model Cabinet Size 24
Cooling BTUH x 1,000 -36
Cooling Tons Nominal 3
Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (37.5 CFM [18 L/s]/1,000 BTUH) (450 CFM [212 L/s]/Ton Nominal) 1350 [637]
Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (33.3 CFM [16 L/s]/1,000 BTUH) (400 CFM [189 L/s]/Ton Nominal) 1200 [566]
Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (30.0 CFM [14 L/s]/1,255 BTUH) (360 CFM [170 L/s]/Ton Nominal) 1080 [510]
Maximum kW Electric Heating & Minimum Electric Heat CFM [L/s] 10
976 [461]
Maximum Electric Heat Rise °F [°C] 44 [7]

What is the detailed airflow performance data for the DURASTAR DRF2TA3624ASTNJB3F model?

The airflow performance data for the DURASTAR DRF2TA3624ASTNJB3F (3 Tons) model with a constant torque (ECM) motor is shown below. This data reflects dry delivery with filter and heaters across a range of external static pressures.

Model/Nominal Cooling Capacity Air-Flow Range (Max/Min) CFM Manufacturer Recommended Blower Size/Motor HP # of Speeds Motor Speed From Factory Motor Speed CFM Dry Delivery/filter/heaters/RPM/Watts
External Static Pressure-Inches W.C.
0.1 0.2 0.3 0.4 0.5 0.6 0.7
DRF2TA36
3 Tons
1306/1040 10×8 1/2 Hp
2 speed
dual voltage
5 4 CFM 808 750 698 633 568 504 448
RPM 615 665 713 780 842 884 929
Watts 91.4 97.7 103.9 112.4 120.2 125.5 131.2
5 CFM 1241 1201 1148 1109 1065 1028 983
RPM 847 880 905 916 955 991 1035
Watts 246.3 254.9 260.9 263.8 273.1 282.5 293.3

How are the motor speed taps configured and adjusted on the DURASTAR DRF2TA3624ASTNJB3F?

The DURASTAR DRF2TA3624ASTNJB3F air handler has a 5-speed constant torque motor. The speed taps are configured for different applications, and the unit is shipped from the factory set to speed tap 5.

Speed tap 1: For continuous fan operation. The airflow is always set at 50% of the speed tap 4 airflow.

Speed tap 2 (low static) & speed tap 3 (high static): For lower tonnage models (1.5 or 2.5 tons).

Speed tap 4 (low static) & speed tap 5 (high static): For higher tonnage models like the DRF2TA3624 (2.0 or 3.0 tons).

To adjust the speed, move the blue wire to the appropriate speed tap on the motor terminal block as required by the application needs.

• Use the low static speed taps (2 and 4) for external static pressures below 0.5″ WC.

• Use the high static speed taps (3 and 5) for external static pressures exceeding 0.5″ WC.


What are the electrical specifications for the blower motor of the DURASTAR DRF2TA3624ASTNJB3F without an electric heater?

The electrical data for the blower motor only on a DURASTAR DRF2TA3624ASTNJB3F is as follows. Note that all blower motors are single-phase motors.

Model/Nominal Cooling Tons Voltage Phase Hertz HP [W] RPM Speeds Circuit Amps. Minimum Circuit Ampacity Maximum Circuit Protector
DRF2TA3624 208/230 1 60 1/2 [373] 300-1100 4 2.7 4 15

What are the electrical requirements for the DURASTAR DRF2TA3624ASTNJB3F when an electric heat kit is installed?

When installing a U.L. Listed original equipment manufacturer provided heater kit, the electrical requirements for the DURASTAR DRF2TA3624ASTNJB3F (listed as DRF2TA3636 in the table) are as follows:

Cooling Capacity Tons (Model) Heater Model No. Heater kW PH/Hz No. Elements – kW Per (208/240V) Type Supply Circuit Circuit Amps. Motor Ampacity Minimum Circuit Ampacity Maximum Circuit Protection
DRF2TA3636 RXHJ-24B/T03J 2.25/3.0 1/60 1-3.0 Single 10.8/12.5 2.7 17/19 20/20
RXHJ-24B/T05J 3.6/4.8 1/60 1-4.8 Single 17.3/20.0 2.7 25/29 25/30
RXHJ-24B/T08J 5.4/7.2 1/60 2-3.6 Single 26.0/30.0 2.7 36/41 40/45
RXHJ-24B/T10J 7.2/9.6 1/60 2-4.8 Single 34.6/40.0 2.7 47/54 50/60

What are the power wiring and grounding instructions for installing the DURASTAR DRF2TA3624ASTNJB3F?

Follow these guidelines for electrical power wiring and grounding:

Code Compliance: Field wiring must comply with the National Electrical Code (C.E.C. in Canada) and any applicable local ordinances.

Grounding: The product must be sufficiently grounded in accordance with all applicable codes.

Conductors: Supply wiring must be 75°C minimum copper conductors only.

Ampacity: Refer to the electrical data for the product’s Ampacity rating and circuit protection requirements.

Grounding Lug: A grounding lug is provided and must be used.

Circuit Protection: Supply circuit protective devices may be fuses or “HACR” type circuit breakers.

Fuse Sizing: If a non-standard fuse size is specified, use the next size larger standard fuse.

Voltage: Do not use 480 volts electrical heaters on 230 volts air handlers.


What optional accessories are available for the DURASTAR DRF2TA3624ASTNJB3F and what are their functions?

Several optional kits and accessories are available to enhance or modify the installation of the DURASTAR DRF2TA3624ASTNJB3F.

Drain Pan Overflow Switch (RXHK-A01): This switch detects a condensate drain blockage and shuts down the outdoor unit to prevent water damage to the surrounding structure.

Bottom Return Conversion Kit (RXHK-B02): Used to divert the return air from the standard front return to a bottom return configuration. The correct kit for the DRF2TA3624ASTNJB3F is RXHK-B02, which fits DRF2TA-FR36 models.

Louvered Cabinet Grill (RXHK-C02): A decorative grill that covers the return air opening of the front return air handler. The correct kit for the DRF2TA3624ASTNJB3F is RXHK-C02, which fits DRF2TA-FR36 models.

Decorative Wall Grill (RXHK-D01 or RXHK-D02): Used in applications where the air handler is installed in a closet or interior wall. It allows adequate return air back to the unit. Refer to the grill’s installation instructions for complete dimensional information.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.