DURASTAR DRF2TA2421ASTNJN0 (01) Image

Free English DURASTAR DRF2TA2421ASTNJN0 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD DURASTAR DRF2TA2421ASTNJN0 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

What are the key features of the DURASTAR DRF2TA2421ASTNJN0 air handler?

The DURASTAR DRF2TA2421ASTNJN0 air handler features a Constant Torque Motor (ECM), Two-Stage Airflow, and a Thermal Expansion Valve (TXV). It offers efficiencies ranging from 13.4 to 14.3 SEER2.


What are the main features and benefits of the DURASTAR DRF2TA2421ASTNJN0?

Front or Bottom Return with aluminum tube and fin coil

TXV for cooling or heat pump operation

Wall-hanging brackets

Built in Filter Rack

Molex Plug Connections for field installed heater kits

Dual Voltage Direct Drive Blower with multi-speed motor

Thermoplastic Drain Pan with bottom primary and secondary connections

Optional Decorative Grill for front return applications

Optional Factory Installed Condensate Float Switch which shuts off the outdoor unit in the event the condensate pan becomes clogged

Cabinet air leakage less than 2% at 1 inch H2O when tested in accordance with ASHRAE Standard 193

Can be field wired for single or two stage applications


What standard equipment is included with the DURASTAR DRF2TA2421ASTNJN0?

Exclusive Incoloy sheath type electric heating elements

Field convertible air supply

Durable framed cleanable air filter

Indoor coil design provides low air side pressure drop, high performance and compact size

PVC condensate elbow is standard on all coils

All indoor coils have aluminum tubing and aluminum fins

Molded polymer corrosion resistant condensate drain pan

Supply and return duct flanges

High and low voltage connection points inside cabinet

Concentric knockouts provided for power connection with hole size up to 2 inches [51 mm] for 1 1/2 inch [38mm] conduit

Internal checked TX valves for quiet refrigerant metering

Front refrigerant and drain connection


What are the maintenance clearance requirements for the DURASTAR DRF2TA2421ASTNJN0?

A clearance of 24 inches [610 mm] is required in front of the unit for filter and coil maintenance.


What are the return air opening dimensions for DURASTAR DRF2TA2421ASTNJN0 series air handlers?

Model Cabinet Size Return Air Opening Width (Inches) Return Air Opening Depth/Length (Inches)
17 15 7/8 19 3/4
21 19 3/8 19 3/4
24 22 7/8 19 3/4

What are the unit dimensions and weights for the DURASTAR DRF2TA2421ASTNJN0 model?

Model (A) Unit Width In. [mm] (B) Unit Height In. [mm] (C) Unit Depth In. [mm] (D) Return Air Opening Width In. [mm] (E) Return Air Opening Height In. [mm] Filter Size in. x in. x in. [mm x mm x mm] Air Flow CFM (Nom.) [L/s] Unit Weight/Shipping Weight (Lbs.) [kg]
DRF2TA2421 21 1/2 [546.1] 36 [914.4] 17 [431.8] 20 [508.0] 17 7/16 [442.9] 20 X 20 X 1 [508 X 508 X 25.4] Low: 600 [283]
High: 800 [378]
95 [43] x 105 [48]

What are the airflow operating limits for the cabinet size of the DURASTAR DRF2TA2421ASTNJN0?

For optimum blower performance, operate the unit in the .3 [8 mm] to .7 inches [18 mm] W.C. external static range. Units with coils should be applied with a minimum of .1 inch [3 mm] W.C. external static range.

Model Cabinet Size 21
Cooling BTUH x 1,000 -24
Cooling Tons Nominal 2
Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (37.5 CFM [18 L/s]/1,000 BTUH) (450 CFM [212 L/s]/Ton Nominal) 900 [425]
Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (33.3 CFM [16 L/s]/1,000 BTUH) (400 CFM [189 L/s]/Ton Nominal) 800 [378]
Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (30.0 CFM [14 L/s]/1,255 BTUH) (360 CFM [170 L/s]/Ton Nominal) 720 [340]
Maximum kW Electric Heating & Minimum Electric Heat CFM [L/s] 10, 690 [326]
Maximum Electric Heat Rise °F [°C] 44 [7]

What is the airflow performance data for the DURASTAR DRF2TA2421ASTNJN0?

Model/Nominal Cooling Capacity Air-Flow Range (Max/Min) CFM Manufacturer Recommended Blower Size/Motor HP # of Speeds Motor Speed From Factory Motor Speed CFM Dry Delivery/filter/heaters/RPM/Watts – External Static Pressure-Inches W.C.
0.1 0.2 0.3 0.4 0.5 0.6 0.7
DRF2TA24 1.5 Tons 825/510 10×6 1/3 Hp 2 speed dual voltage 5 2 CFM 537 495 451 404 343 286 252
RPM 608 656 702 752 826 879 935
Watts 51.2 54.5 57.6 60.9 65.9 69.5 73.2
3 CFM 735 702 666 634 600 565 528
RPM 757 794 836 872 905 942 981
Watts 99.1 103.2 107.7 112 115.6 119.6 124.1
DRF2TA24 2 Tons 973/733 10×6 1/3 Hp 2 speed dual voltage 5 4 CFM 654 616 581 542 503 463 399
RPM 694 736 777 818 858 899 971
Watts 76.4 80.1 83.7 87.6 91.3 95.1 101.6
5 CFM 887 858 830 802 771 743 717
RPM 876 914 945 976 1014 1044 1070
Watts 156 161.8 166.8 171.5 177.5 182.3 186.2

How are the motor speed taps configured on the DURASTAR DRF2TA2421ASTNJN0?

All DRF2TA air-handlers have 5-speed constant torque motors.

Speed tap 1 is for continuous fan.

Speed tap 2 (low static) and speed tap 3 (high static) are for lower tonnage (1.5 or 2.5 tons).

Speed tap 4 (low static) and speed tap 5 (high static) are for higher tonnage (2.0 or 3.0 tons).

DRF2TA air handlers are always shipped from the factory at speed tap 5.

The low static speed tap 2 (lower tonnage) and 4 (higher tonnage) are for external static pressures below 0.5″ WC. The high static speed tap 3 (lower tonnage) and 5 (higher tonnage) are used for external static exceeding 0.5″ WC. Move the blue wire to the appropriate speed tap on the motor terminal block as required by the application needs.

The airflow for continuous fan (speed tap 1) is always set at 50% of the speed tap 4.


What are the electrical specifications for the blower motor only on the DURASTAR DRF2TA2421ASTNJN0?

Model/Nominal Cooling Tons Voltage Phase Hertz HP [W] RPM Speeds Circuit Amps. Minimum Circuit Ampacity Maximum Circuit Protector
DRF2TA2421 208/230 1 60 1/3 [249] 300-1100 4 1.9 3 15

*Blower motors are all single phase motors.


What are the electrical wiring and grounding requirements for the DURASTAR DRF2TA2421ASTNJN0?

Field wiring must comply with the National Electrical Code.

This product must be sufficiently grounded in accordance with (C.E.C. in Canada) and any applicable local ordinance.

Supply wiring must be 75°C minimum copper conductors only.

See electrical data for product Ampacity rating and Circuit Protector requirement.

A grounding lug is provided.


What is the purpose of the optional Drain Pan Overflow Switch Kit RXHK-A01 for the DURASTAR DRF2TA2421ASTNJN0?

The Drain Pan Overflow Switch Kit RXHK-A01 is used to detect a condensate drain blockage. If a blockage is detected, it will shut down the outdoor unit to prevent structural damage to the surrounding structures of the air handler.


How is the return air diverted to a bottom return on the DURASTAR DRF2TA2421ASTNJN0?

The Bottom Return Conversion Kit is used to divert the return air from the factory standard front return to a bottom return. The compatible kit for the DURASTAR DRF2TA2421ASTNJN0 is RXHK-B01.


What is the purpose of the Louvered Cabinet Grill Kit for the DURASTAR DRF2TA2421ASTNJN0?

The Louvered Cabinet Grill Kit is used as a decorative grill that covers the return air opening of the front return air handler. The compatible kit for the DURASTAR DRF2TA2421ASTNJN0 is RXHK-C01.


When is a Decorative Wall Grill Kit used with the DURASTAR DRF2TA2421ASTNJN0?

A Decorative Wall Grill Kit (RXHK-D01 or RXHK-D02) is used in applications where the air handler is installed in a closet or interior wall. It allows for adequate return air back to the unit.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD DURASTAR DRF2TA2421ASTNJN0 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.