What are the main features of the DURASTAR DRF2TA2421ASTNJN0F air handler?

The DURASTAR DRF2TA2421ASTNJN0F air handler features a Constant Torque Motor (ECM), Two-Stage Airflow, and a Thermal Expansion Valve (TXV). It is designed for efficiencies ranging from 13.4 to 14.3 SEER2.


What are the features and benefits of the DURASTAR DRF2TA2421ASTNJN0F air handler?

Features and Benefits include:

• Front or Bottom Return with aluminum tube and fin coil

• TXV for cooling or heat pump operation

• Wall-hanging brackets

• Built in Filter Rack

• Molex Plug Connections for field installed heater kits

• Dual Voltage Direct Drive Blower with multi-speed motor

• Thermoplastic Drain Pan with bottom primary and secondary connections

• Optional Decorative Grill for front return applications

• Optional Factory Installed Condensate Float Switch which shuts off the outdoor unit in the event the condensate pan becomes clogged

• Cabinet air leakage less than 2% at 1 inch H2O when tested in accordance with ASHRAE Standard 193

• Can be field wired for single or two stage applications


What standard equipment is included with the DURASTAR DRF2TA2421ASTNJN0F air handler?

The standard equipment includes:

• Exclusive Incoloy sheath type electric heating elements

• Field convertible air supply

• Durable framed cleanable air filter

• Indoor coil design provides low air side pressure drop, high performance and compact size

• PVC condensate elbow is standard on all coils

• All indoor coils have aluminum tubing and aluminum fins

• Molded polymer corrosion resistant condensate drain pan

• Supply and return duct flanges

• High and low voltage connection points inside cabinet

• Concentric knockouts provided for power connection with hole size up to 2 inches [51 mm] for 1 1/2 inch [38mm] conduit

• Internal checked TX valves for quiet refrigerant metering

• Front refrigerant and drain connection


What are the unit dimensions and weight for the DURASTAR DRF2TA2421ASTNJN0F?

Model (A) Unit Width In. [mm] (B) Unit Height In. [mm] (C) Unit Depth In. [mm] (D) Return Air Opening Width In. [mm] (E) Return Air Opening Height In. [mm] Filter Size in. x in. x in. [mm x mm x mm] Air Flow CFM (Nom.) [L/s] Low / High Unit Weight/Shipping Weight (Lbs.) [kg]
DRF2TA2421 21 1/2 [546.1] 36 [914.4] 17 [431.8] 20 [508.0] 17 7/16 [442.9] 20 X 20 X 1 [508 X 508 X 25.4] 600 [283] / 800 [378] 95 [43] x 105 [48]

What are the return air opening dimensions for the DURASTAR DRF2TA2421ASTNJN0F air handler?

Model Cabinet Size Return Air Opening Width (Inches) Return Air Opening Depth/Length (Inches)
21 19 3/8 19 3/4

What are the airflow operating limits for the DURASTAR DRF2TA2421ASTNJN0F air handler (Model Cabinet Size 21)?

For optimum blower performance, operate the unit in the .3 to .7 inches W.C. external static range. Units with coils should be applied with a minimum of .1 inch W.C. external static range.

Model Cabinet Size 21
Cooling BTUH x 1,000 -24
Cooling Tons Nominal 2
Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (37.5 CFM [18 L/s]/1,000 BTUH) (450 CFM [212 L/s]/Ton Nominal) 900 [425]
Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (33.3 CFM [16 L/s]/1,000 BTUH) (400 CFM [189 L/s]/Ton Nominal) 800 [378]
Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (30.0 CFM [14 L/s]/1,255 BTUH) (360 CFM [170 L/s]/Ton Nominal) 720 [340]
Maximum kW Electric Heating & Minimum Electric Heat CFM [L/s] 10, 690 [326]
Maximum Electric Heat Rise °F [°C] 44 [7]

What is the airflow performance data for the DURASTAR DRF2TA2421ASTNJN0F air handler?

The following table provides the CFM Dry Delivery/filter/heaters/RPM/Watts at various external static pressures.

Model/Nominal Cooling Capacity Air-Flow Range (Max/Min) CFM Manufacturer Recommended Blower Size/Motor HP # of Speeds Motor Speed From Factory Motor Speed External Static Pressure-Inches W.C.
0.1 0.2 0.3 0.4 0.5 0.6 0.7
DRF2TA24 / 1.5 Tons 825/510 10×6 1/3 Hp 2 speed dual voltage 5 2 CFM 537 495 451 404 343 286 252
RPM 608 656 702 752 826 879 935
Watts 51.2 54.5 57.6 60.9 65.9 69.5 73.2
3 CFM 735 702 666 634 600 565 528
RPM 757 794 836 872 905 942 981
Watts 99.1 103.2 107.7 112 115.6 119.6 124.1
DRF2TA24 / 2 Tons 973/733 10×6 1/3 Hp 2 speed dual voltage 5 4 CFM 654 616 581 542 503 463 399
RPM 694 736 777 818 858 899 971
Watts 76.4 80.1 83.7 87.6 91.3 95.1 101.6
5 CFM 887 858 830 802 771 743 717
RPM 876 914 945 976 1014 1044 1070
Watts 156 161.8 166.8 171.5 177.5 182.3 186.2

How do I select the correct motor speed tap for my DURASTAR DRF2TA2421ASTNJN0F air handler?

The DURASTAR DRF2TA2421ASTNJN0F air handler has a 5-speed constant torque motor. The correct speed tap is selected based on the application’s tonnage and external static pressure.

Speed tap 1 is for continuous fan operation. The airflow for the continuous fan is always set at 50% of the speed tap 4 airflow.

Speed tap 2 (low static) and speed tap 3 (high static) are for lower tonnage applications (1.5 tons).

Speed tap 4 (low static) and speed tap 5 (high static) are for higher tonnage applications (2.0 tons).

• The unit is shipped from the factory set to speed tap 5.

• Use a low static speed tap (2 or 4) for external static pressures below 0.5″ WC.

• Use a high static speed tap (3 or 5) for external static pressures exceeding 0.5″ WC.

To change the setting, move the blue wire to the appropriate speed tap on the motor terminal block as required by your application.


What are the electrical specifications for the blower motor only on the DURASTAR DRF2TA2421ASTNJN0F?

Model/Nominal Cooling Tons Voltage Phase Hertz HP [W] RPM Speeds Circuit Amps. Minimum Circuit Ampacity Maximum Circuit Protector
DRF2TA2421 208/230 1 60 1/3 [249] 300-1100 4 1.9 3 15

*Blower motors are all single phase motors.


What are the electrical wiring requirements for the DURASTAR DRF2TA2421ASTNJN0F air handler?

Follow these guidelines for power wiring and grounding:

• Field wiring must comply with the National Electrical Code.

• This product must be sufficiently grounded in accordance with (C.E.C. in Canada) and any applicable local ordinance.

• Supply wiring must be 75°C minimum copper conductors only, in accordance with local ordinances.

• See electrical data for product Ampacity rating and Circuit Protector requirement.

• A grounding lug is provided.

• Supply circuit protective devices may be fused or “HACR” type circuit breakers.

• If a non-standard fuse size is specified, use the next size larger standard fuse size.


What is the purpose of the Drain Pan Overflow Switch Kit (RXHK-A01) for the DURASTAR DRF2TA2421ASTNJN0F?

The Drain Pan Overflow Switch Kit RXHK-A01 is an accessory used to detect a condensate drain blockage. If a blockage is detected, the switch will shut down the outdoor unit to prevent structural damage to the surrounding structures of the air handler from overflowing water.


How do I convert the DURASTAR DRF2TA2421ASTNJN0F from front return to bottom return?

To convert the air handler from the factory standard front return to a bottom return configuration, use the Bottom Return Conversion Kit RXHK-B01. This kit is used to divert the return air to the bottom of the unit.


What is the Louvered Cabinet Grill Kit (RXHK-C01) used for with the DURASTAR DRF2TA2421ASTNJN0F?

The Louvered Cabinet Grill Kit RXHK-C01 is used as a decorative grill that covers the return air opening of the front return air handler.


When should the Decorative Wall Grill Kit (RXHK-D01) be used with the DURASTAR DRF2TA2421ASTNJN0F?

The Decorative Wall Grill Kit RXHK-D01 is used in applications where the air handler is installed in a closet or interior wall. It allows for adequate return air back to the unit. Refer to the kit’s installation instructions for complete dimensional information when selecting a decorative wall grill.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD DURASTAR DRF2TA2421ASTNJN0F (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.