What are the key features and benefits of the DURASTAR DRF2TA3624ASTNJB8 air handler?

The DURASTAR DRF2TA3624ASTNJB8 air handler includes the following features and benefits:

• Front or Bottom Return with aluminum tube and fin coil

• TXV for cooling or heat pump operation

• Wall-hanging brackets

• Built in Filter Rack

• Molex Plug Connections for field installed heater kits

• Dual Voltage Direct Drive Blower with multi-speed motor

• Thermoplastic Drain Pan with bottom primary and secondary connections

• Optional Decorative Grill for front return applications

• Optional Factory Installed Condensate Float Switch which shuts off the outdoor unit in the event the condensate pan becomes clogged

• Cabinet air leakage less than 2% at 1 inch H2O when tested in accordance with ASHRAE Standard 193

• Can be field wired for single or two stage applications


How is the model number for the DURASTAR DRF2TA3624ASTNJB8 identified?

The model number DRF2TA3624ASTNJB8 breaks down as follows:

Position Code Description
DR Brand DR – Durastar
F Product Category F – Front Return
2 Stages of Airflow 2 – 2-Stage
T Motor Type T – Constant Torque
A Refrigerant A – R-410A
36 Capacity 36 – 36,000 [10.55 kW]
24 Width 24 – 24.5″
A Major Series A – 1st Design
S Efficiency S – Standard
T Metering T – TXV
N Coil Series N – N Coil
J Voltage J – 208-240/1/60
B Disconnect B – Breaker
8 Factory Heat 8 – 8 kW

What standard equipment is included with the DURASTAR DRF2TA3624ASTNJB8?

The standard equipment for the DURASTAR DRF2TA3624ASTNJB8 includes:

• Exclusive Incoloy sheath type electric heating elements

• Field convertible air supply

• Durable framed cleanable air filter

• Indoor coil design provides low air side pressure drop, high performance and compact size

• PVC condensate elbow is standard on all coils

• All indoor coils have aluminum tubing and aluminum fins

• Molded polymer corrosion resistant condensate drain pan

• Supply and return duct flanges

• High and low voltage connection points inside cabinet

• Concentric knockouts provided for power connection with hole size up to 2 inches [51 mm] for 1 1/2 inch [38mm] conduit

• Internal checked TX valves for quiet refrigerant metering

• Front refrigerant and drain connection


What are the unit dimensions and weight for the DURASTAR DRF2TA3624ASTNJB8?

Model (A) Unit Width In. [mm] (B) Unit Height In. [mm] (C) Unit Depth In. [mm] (D) Return Air Opening Width In. [mm] (E) Return Air Opening Height In. [mm] Filter Size in. x in. x in. [mm x mm x mm] Air Flow CFM (Nom.) [L/s] Unit Weight/Shipping Weight (Lbs.) [kg]
Low High
DRF2TA3624 24 [609.6] 36 [914.4] 21 [533.4] 23 [584.2] 21 3/8 [542.9] 20 X 25 X 1 [508 X 635 X 25.4] 1000 [472] 1200 [566] 95 [43] x 105 [48]

What are the airflow operating limits for the DURASTAR DRF2TA3624ASTNJB8?

For optimal blower performance, operate the unit in the .3 [8 mm] to .7 inches [18 mm] W.C. external static range. Units with coils should be applied with a minimum of .1 inch [3 mm] W.C. external static range. The operating limits for the cabinet size are as follows:

Model Cabinet Size 24
Cooling BTUH x 1,000 -36
Cooling Tons Nominal 3
Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (37.5 CFM [18 L/s]/1,000 BTUH) (450 CFM [212 L/s]/Ton Nominal) 1350 [637]
Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (33.3 CFM [16 L/s]/1,000 BTUH) (400 CFM [189 L/s]/Ton Nominal) 1200 [566]
Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (30.0 CFM [14 L/s]/1,255 BTUH) (360 CFM [170 L/s]/Ton Nominal) 1080 [510]
Maximum kW Electric Heating & Minimum Electric Heat CFM [L/s] 10, 976 [461]
Maximum Electric Heat Rise °F [°C] 44 [7]

What is the airflow performance data for the DURASTAR DRF2TA3624ASTNJB8?

The airflow performance data for the DURASTAR DRF2TA3624ASTNJB8 (3 Tons model) is based on a 10×8 1/2 Hp 2-speed dual voltage motor, providing an air-flow range of 1306/1040 (Max/Min) CFM.

CFM Dry Delivery/filter/heaters/RPM/Watts at External Static Pressure-Inches W.C.
Motor Speed Metric 0.1 0.2 0.3 0.4 0.5 0.6 0.7
4 CFM 808 750 698 633 568 504 448
RPM 615 665 713 780 842 884 929
Watts 91.4 97.7 103.9 112.4 120.2 125.5 131.2
5 CFM 1241 1201 1148 1109 1065 1028 983
RPM 847 880 905 916 955 991 1035
Watts 246.3 254.9 260.9 263.8 273.1 282.5 293.3

How are the motor speed taps on the DURASTAR DRF2TA3624ASTNJB8 configured and used?

The DURASTAR DRF2TA3624ASTNJB8 air handler has a 5-speed constant torque motor. The speed taps are configured for different applications:

Speed tap 1 is for continuous fan.

Speed tap 2 (low static) and speed tap 3 (high static) are for lower tonnage applications (1.5 or 2.5 tons).

Speed tap 4 (low static) and speed tap 5 (high static) are for higher tonnage applications (2.0 or 3.0 tons).

The air handler is shipped from the factory set to speed tap 5.

Use the low static speed tap (2 or 4) for external static pressures below 0.5″ WC. Use the high static speed tap (3 or 5) for external static pressures exceeding 0.5″ WC. To change speeds, move the blue wire to the appropriate speed tap on the motor terminal block as required by the application.

The airflow for the continuous fan (speed tap 1) is always set at 50% of the speed tap 4 airflow.


What are the electrical specifications for the blower motor of the DURASTAR DRF2TA3624ASTNJB8 without electric heat?

Model/Nominal Cooling Tons Voltage Phase Hertz HP [W] RPM Speeds Circuit Amps. Minimum Circuit Ampacity Maximum Circuit Protector
DRF2TA3624 208/230 1 60 1/2 [373] 300-1100 4 2.7 4 15

*Blower motors are all single phase motors.


What are the electrical specifications for the DURASTAR DRF2TA3624ASTNJB8 when used with an electric heater kit?

Cooling Capacity Tons Model No. Heater kW PH/Hz No. Elements – kW Per (208/240V) Type Supply Circuit Circuit Amps. Motor Ampacity Minimum Circuit Ampacity Maximum Circuit Protection
DRF2TA3636 RXHJ-24B/T03J 2.25/3.0 1/60 1-3.0 Single 10.8/12.5 2.7 17/19 20/20
RXHJ-24B/T05J 3.6/4.8 1/60 1-4.8 Single 17.3/20.0 2.7 25/29 25/30
RXHJ-24B/T08J 5.4/7.2 1/60 2-3.6 Single 26.0/30.0 2.7 36/41 40/45
RXHJ-24B/T10J 7.2/9.6 1/60 2-4.8 Single 34.6/40.0 2.7 47/54 50/60

• Electric heater BTUH = (heater watts + motor watts) x 3.414 (see airflow table for motor watts.)

• J voltage (230V) single phase air handler is designed to be used with single or three phase.

• Supply circuit protective devices may be fused or “HACR” type circuit breakers.

• If non-standard fuse size is specified, use next size larger standard fuse size. Without the heater, bring only two leads to terminal block, cap, insulate and fully secure the third lead.

• Largest motor load is included in single circuit or circuit 1 of multiple circuits.

• Do not use 480 volts electrical heaters on 230 volts air handler.


What are the power wiring and grounding requirements for the DURASTAR DRF2TA3624ASTNJB8?

• Field wiring must comply with the National Electrical Code.

• This product must be sufficiently grounded in accordance with (C.E.C. in Canada) and any applicable local ordinance.

• Supply wiring must be 75°C minimum copper conductors only, in accordance with the National Electrical Code (C.E.C. in Canada) and any applicable Local ordinance.

• See electrical data for product Ampacity rating and Circuit Protector requirement.

• A grounding lug is provided.


What optional accessories and kits are available for the DURASTAR DRF2TA3624ASTNJB8?

The following accessories and kits are available for the DURASTAR DRF2TA3624ASTNJB8:

Drain Pan Over Flow Switch RXHK-A01: This switch is used to detect condensate drain blockage and will shut down the outdoor unit to prevent structural damage to the surrounding structures of the air handler.

Bottom Return Conversion Kit RXHK-B02: This kit is used to divert the return air from the factory standard front return to a bottom return. Accessory Number RXHK-B02 is compatible with indoor unit DRF2TA-FR36.

Louvered Cabinet Grill RXHK-C02: This is a decorative grill that covers the return air opening of the front return air handler. Accessory Number RXHK-C02 is compatible with indoor unit DRF2TA-FR36.

Decorative Wall Grill RXHK-D01 or RXHK-D02: This grill is used in applications where the air handler is installed in a closet or interior wall and allows adequate return air back to the unit.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD DURASTAR DRF2TA3624ASTNJB8 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.