What are the features and benefits of the DURASTAR DRF2TA3624ASTNJB8F air handler?
The DURASTAR DRF2TA3624ASTNJB8F air handler includes the following features and benefits:
General Features:
• Front or Bottom Return with aluminum tube and fin coil
• TXV for cooling or heat pump operation
• Wall-hanging brackets
• Built in Filter Rack
• Molex Plug Connections for field installed heater kits
• Dual Voltage Direct Drive Blower with multi-speed motor
• Thermoplastic Drain Pan with bottom primary and secondary connections
• Optional Decorative Grill for front return applications
• Optional Factory Installed Condensate Float Switch which shuts off the outdoor unit in the event the condensate pan becomes clogged
• Cabinet air leakage less than 2% at 1 inch H2O when tested in accordance with ASHRAE Standard 193
• Can be field wired for single or two stage applications
Standard Equipment:
• Exclusive Incoloy sheath type electric heating elements
• Field convertible air supply
• Durable framed cleanable air filter
• Indoor coil design provides low air side pressure drop, high performance and compact size
• PVC condensate elbow is standard on all coils
• All indoor coils have aluminum tubing and aluminum fins
• Molded polymer corrosion resistant condensate drain pan
• Supply and return duct flanges
• High and low voltage connection points inside cabinet
• Concentric knockouts provided for power connection with hole size up to 2 inches [51 mm] for 1 1/2 inch [38mm] conduit
• Internal checked TX valves for quiet refrigerant metering
• Front refrigerant and drain connection
How is the model number for the DURASTAR DRF2TA3624ASTNJB8F air handler identified?
The model number nomenclature for the DURASTAR DRF2TA3624ASTNJB8F air handler series is broken down as follows:
| DR | F | 2 | T | A | 36 | 24 | A | S | T | N | J | B | 8 | F |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Brand | Product Category | Stages Of Airflow | Motor Type | Refrigerant | Capacity | Width | Major Series | Efficiency | Metering | Coil Series | Voltage | Disconnect | Factory Heat | Option Code |
| DR – Durastar | F – Front Return | 2 – 2-Stage | T – Constant Torque | A – R-410A | 24 – 24,000 [7.03 kW] 36 – 36,000 [10.55 kW] |
21 – 21″ 24 – 24.5″ |
A – 1st Design | S – Standard | T – TXV | N – N Coil | J – 208-240/1/60 | B – Breaker N – None |
0 – No Heat 3 – 3 kW 5 – 5 kW 8 – 8 kW 1 – 10 kW |
F – Float Switch |
What are the return air opening dimensions for the DURASTAR DRF2TA3624ASTNJB8F series?
| Model Cabinet Size | Return Air Opening Width (Inches) | Return Air Opening Depth/Length (Inches) |
|---|---|---|
| 17 | 15 7/8 | 19 3/4 |
| 21 | 19 3/8 | 19 3/4 |
| 24 | 22 7/8 | 19 3/4 |
What are the unit dimensions and weights for the DURASTAR DRF2TA3624ASTNJB8F series models?
| Model | (A) Unit Width In. [mm] | (B) Unit Height In. [mm] | (C) Unit Depth In. [mm] | (D) Return Air Opening Width In. [mm] | (E) Return Air Opening Height In. [mm] | Filter Size in. x in. x in. [mm x mm x mm] | Air Flow CFM (Nom.) [L/s] | Unit Weight/Shipping Weight (Lbs.) [kg] | |
|---|---|---|---|---|---|---|---|---|---|
| Low | High | ||||||||
| DRF2TA2421 | 21 1/2 [546.1] | 36 [914.4] | 17 [431.8] | 20 [508.0] | 17 7/16 [442.9] | 20 X 20 X 1 [508 X 508 X 25.4] | 600 [283] | 800 [378] | 95 [43] x 105 [48] |
| DRF2TA3624 | 24 [609.6] | 36 [914.4] | 21 [533.4] | 23 [584.2] | 21 3/8 [542.9] | 20 X 25 X 1 [508 X 635 X 25.4] | 1000 [472] | 1200 [566] | 95 [43] x 105 [48] |
What are the airflow operating limits for the DURASTAR DRF2TA3624ASTNJB8F series?
For optimum blower performance, operate the DURASTAR DRF2TA3624ASTNJB8F unit in the .3 [8 mm] to .7 inches [18 mm] W.C. external static range. Units with coils should be applied with a minimum of .1 inch [3 mm] W.C. external static range. The airflow operating limits are as follows:
| Model Cabinet Size | 21 | 24 |
|---|---|---|
| Cooling BTUH x 1,000 | -24 | -36 |
| Cooling Tons Nominal | 2 | 3 |
| Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (37.5 CFM [18 L/s]/1,000 BTUH) (450 CFM [212 L/s]/Ton Nominal) | 900 [425] | 1350 [637] |
| Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (33.3 CFM [16 L/s]/1,000 BTUH) (400 CFM [189 L/s]/Ton Nominal) | 800 [378] | 1200 [566] |
| Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (30.0 CFM [14 L/s]/1,255 BTUH) (360 CFM [170 L/s]/Ton Nominal) | 720 [340] | 1080 [510] |
| Maximum kW Electric Heating & Minimum Electric Heat CFM [L/s] | 10 690 [326] |
10 976 [461] |
| Maximum Electric Heat Rise °F [°C] | 44 [7] | 44 [7] |
What is the airflow performance data for the DURASTAR DRF2TA3624ASTNJB8F air handler with a Constant Torque (ECM) Motor?
| Model/ Nominal Cooling Capacity | Air-Flow Range (Max/Min) CFM | Manufacturer Recommended Blower Size/ Motor HP # of Speeds | Motor Speed From Factory | Motor Speed | CFM Dry Delivery/filter/heaters/RPM/Watts External Static Pressure-Inches W.C. | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | ||||||
| DRF2TA24 1.5 Tons | 825/510 | 10×6 1/3 Hp 2 speed dual voltage | 5 | 2 | CFM | 537 | 495 | 451 | 404 | 343 | 286 | 252 |
| RPM | 608 | 656 | 702 | 752 | 826 | 879 | 935 | |||||
| Watts | 51.2 | 54.5 | 57.6 | 60.9 | 65.9 | 69.5 | 73.2 | |||||
| 3 | CFM | 735 | 702 | 666 | 634 | 600 | 565 | 528 | ||||
| RPM | 757 | 794 | 836 | 872 | 905 | 942 | 981 | |||||
| Watts | 99.1 | 103.2 | 107.7 | 112 | 115.6 | 119.6 | 124.1 | |||||
| DRF2TA24 2 Tons | 973/733 | 10×6 1/3 Hp 2 speed dual voltage | 5 | 4 | CFM | 654 | 616 | 581 | 542 | 503 | 463 | 399 |
| RPM | 694 | 736 | 777 | 818 | 858 | 899 | 971 | |||||
| Watts | 76.4 | 80.1 | 83.7 | 87.6 | 91.3 | 95.1 | 101.6 | |||||
| 5 | CFM | 887 | 858 | 830 | 802 | 771 | 743 | 717 | ||||
| RPM | 876 | 914 | 945 | 976 | 1014 | 1044 | 1070 | |||||
| Watts | 156 | 161.8 | 166.8 | 171.5 | 177.5 | 182.3 | 186.2 | |||||
| DRF2TA36 2.5 Tons | 1145/894 | 10×8 1/2 Hp 2 speed dual voltage | 5 | 2 | CFM | 772 | 698 | 635 | 569 | 497 | 438 | 366 |
| RPM | 595 | 639 | 698 | 771 | 821 | 866 | 933 | |||||
| Watts | 82.9 | 84.9 | 91.6 | 100 | 105.8 | 110.7 | 118.3 | |||||
| 3 | CFM | 1106 | 1053 | 1004 | 962 | 918 | 864 | 814 | ||||
| RPM | 776 | 816 | 838 | 862 | 901 | 955 | 1007 | |||||
| Watts | 183.3 | 191.4 | 195.7 | 200.5 | 208.4 | 219.3 | 230.2 | |||||
| DRF2TA36 3 Tons | 1306/1040 | 10×8 1/2 Hp 2 speed dual voltage | 5 | 4 | CFM | 808 | 750 | 698 | 633 | 568 | 504 | 448 |
| RPM | 615 | 665 | 713 | 780 | 842 | 884 | 929 | |||||
| Watts | 91.4 | 97.7 | 103.9 | 112.4 | 120.2 | 125.5 | 131.2 | |||||
| 5 | CFM | 1241 | 1201 | 1148 | 1109 | 1065 | 1028 | 983 | ||||
| RPM | 847 | 880 | 905 | 916 | 955 | 991 | 1035 | |||||
| Watts | 246.3 | 254.9 | 260.9 | 263.8 | 273.1 | 282.5 | 293.3 | |||||
NOTE: All DRF2TA air-handlers have 5 speed constant torque motors.
• Speed tap 1 is for continuous fan.
• Speed tap 2 (low static) and speed tap 3 (high static) are for lower tonnage (1.5 or 2.5 tons).
• Speed tap 4 (low static) and speed tap 5 (high static) are for higher tonnage (2.0 or 3.0 tons).
• DRF2TA air handlers are always shipped from factory at speed tap 5.
• The low static speed tap 2 (lower tonnage) and 4 (higher tonnage) are for external static pressures below 0.5″ WC. The high static speed tap 3 (lower tonnage) and 5 (higher tonnage) are used for external static exceeding 0.5″ WC. Move the blue wire to the appropriate speed tap on the motor terminal block as required by the application needs.
• The airflow for continuous fan (speed tap 1) is always set at 50% of the speed tap 4.
• The above airflow table lists the airflow information for air handlers with maximum heater allowed for each model.
What are the electrical specifications for the blower motor only on the DURASTAR DRF2TA3624ASTNJB8F?
The following table details the electrical specifications for the blower motor without an electric heat kit. Blower motors are all single phase motors.
| Model/Nominal Cooling Tons | Voltage | Phase | Hertz | HP [W] | RPM | Speeds | Circuit Amps. | Minimum Circuit Ampacity | Maximum Circuit Protector |
|---|---|---|---|---|---|---|---|---|---|
| DRF2TA2421 | 208/230 | 1 | 60 | 1/3 [249] | 300-1100 | 4 | 1.9 | 3 | 15 |
| DRF2TA3624 | 208/230 | 1 | 60 | 1/2 [373] | 300-1100 | 4 | 2.7 | 4 | 15 |
What are the electrical specifications for the DURASTAR DRF2TA3624ASTNJB8F when using an electric heat kit?
Installation of a U.L. Listed original equipment manufacturer provided heater kit is recommended for all auxiliary heating requirements. The electrical data for units with electric heat is as follows:
| Cooling Capacity Tons | Model No. | Heater kW | PH/Hz | No. Elements – kW Per | (208/240V) Type Supply Circuit | Circuit Amps. | Motor Ampacity | Minimum Circuit Ampacity | Maximum Circuit Protection |
|---|---|---|---|---|---|---|---|---|---|
| DRF2TA3624 | RXHJ-21B/T03J | 2.25/3.0 | 1/60 | 1-3.0 | Single | 10.8/12.5 | 1.9 | 16/18 | 20/20 |
| RXHJ-21B/T05J | 3.6/4.8 | 1/60 | 1-4.8 | Single | 17.3/20.0 | 1.9 | 0.9 | 25/30 | |
| RXHJ-21B/T08J | 5.4/7.2 | 1/60 | 2-3.6 | Single | 26.0/30.0 | 1.9 | 35/40 | 35/40 | |
| RXHJ-21B/T10J | 7.2/9.6 | 1/60 | 2-4.8 | Single | 34.6/40.0 | 1.9 | 0.9 | 50/60 | |
| DRF2TA3636 | RXHJ-24B/T03J | 2.25/3.0 | 1/60 | 1-3.0 | Single | 10.8/12.5 | 2.7 | 17/19 | 20/20 |
| RXHJ-24B/T05J | 3.6/4.8 | 1/60 | 1-4.8 | Single | 17.3/20.0 | 2.7 | 25/29 | 25/30 | |
| RXHJ-24B/T08J | 5.4/7.2 | 1/60 | 2-3.6 | Single | 26.0/30.0 | 2.7 | 36/41 | 40/45 | |
| RXHJ-24B/T10J | 7.2/9.6 | 1/60 | 2-4.8 | Single | 34.6/40.0 | 2.7 | 47/54 | 50/60 |
• Electric heater BTUH – (heater watts + motor watts) x 3.414 (see airflow table for motor watts.)
• J voltage (230V) single phase air handler is designed to be used with single or three phase.
• Supply circuit protective devices may be fused or “HACR” type circuit breakers.
• If non-standard fuse size is specified, use next size larger standard fuse size. Without the heater, bring only two leads to terminal block, cap, insulate and fully secure the third lead.
• Largest motor load is included in single circuit or circuit 1 of multiple circuits.
• Do not use 480 volts electrical heaters on 230 volts air handler.
What are the electrical power wiring and grounding requirements for the DURASTAR DRF2TA3624ASTNJB8F?
When wiring the DURASTAR DRF2TA3624ASTNJB8F, please adhere to the following requirements:
• Field wiring must comply with the National Electrical Code.
• This product must be sufficiently grounded in accordance with (C.E.C. in Canada) and any applicable local ordinance.
• Supply wiring must be 75°C minimum copper conductors only, in accordance with the National Electrical Code (C.E.C. in Canada) and any applicable local ordinance.
• See electrical data for product Ampacity rating and Circuit Protector requirement.
• A grounding lug is provided.
What is the purpose of the Drain Pan Over Flow Switch RXHK-A01 for the DURASTAR DRF2TA3624ASTNJB8F?
What is the Bottom Return Conversion Kit RXHK for the DURASTAR DRF2TA3624ASTNJB8F?
The Bottom Return Conversion Kit is used to divert the return air from the factory standard front return to a bottom return configuration. The correct kit depends on your specific indoor unit model.
| Accessory Number | Indoor Unit |
|---|---|
| RXHK-B01 | DRF2TA-FR18 |
| DRF2TA-FR24 | |
| RF1T-FR24 | |
| RXHK-B02 | DRF2TA-FR30 |
| DRF2TA-FR36 | |
| RF1T-FR36 |
What is the Louvered Cabinet Grill RXHK for the DURASTAR DRF2TA3624ASTNJB8F?
The Louvered Cabinet Grill is a decorative grill accessory that covers the return air opening of the front return air handler. The correct grill depends on your specific indoor unit model.
| Accessory Number | Indoor Unit |
|---|---|
| RXHK-C01 | DRF2TA-FR18 |
| DRF2TA-FR24 | |
| RF1T-FR24 | |
| RXHK-C02 | DRF2TA-FR30 |
| DRF2TA-FR36 | |
| RF1T-FR36 |
When is the Decorative Wall Grill RXHK-D01 or RXHK-D02 used with the DURASTAR DRF2TA3624ASTNJB8F?
What should be done before proceeding with the installation of the DURASTAR DRF2TA3624ASTNJB8F?