DURASTAR DRF2TA2421ASTNJB1F (01) Image

Free English DURASTAR DRF2TA2421ASTNJB1F (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD DURASTAR DRF2TA2421ASTNJB1F (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

What are the features and benefits of the DURASTAR DRF2TA2421ASTNJB1F air handler?

The DURASTAR DRF2TA2421ASTNJB1F air handler includes the following features and benefits:

• Front or Bottom Return with an aluminum tube and fin coil.

• Thermal Expansion Valve (TXV) for cooling or heat pump operation.

• Wall-hanging brackets for installation flexibility.

• A built-in Filter Rack.

• Molex Plug Connections for field-installed heater kits.

• A Dual Voltage Direct Drive Blower with a multi-speed motor.

• A Thermoplastic Drain Pan with bottom primary and secondary connections.

• An optional Decorative Grill is available for front return applications.

• An optional Factory Installed Condensate Float Switch can be added, which shuts off the outdoor unit if the condensate pan becomes clogged.

• The cabinet has an air leakage rate of less than 2% at 1 inch H2O when tested in accordance with ASHRAE Standard 193.

• It can be field-wired for single or two-stage applications.


What standard equipment is included with the DURASTAR DRF2TA2421ASTNJB1F?

The standard equipment for the DURASTAR DRF2TA2421ASTNJB1F includes:

• Exclusive Incoloy sheath type electric heating elements.

• Field convertible air supply.

• A durable framed cleanable air filter.

• An indoor coil design that provides low air side pressure drop, high performance, and a compact size.

• A PVC condensate elbow is standard on all coils.

• All indoor coils feature aluminum tubing and aluminum fins.

• A molded polymer corrosion-resistant condensate drain pan.

• Supply and return duct flanges.

• High and low voltage connection points located inside the cabinet.

• Concentric knockouts for power connection, with hole sizes up to 2 inches for 1 1/2 inch conduit.

• Internal checked TX valves for quiet refrigerant metering.

• Front refrigerant and drain connection.


How can I interpret the model number for DURASTAR DRF2TA series air handlers?

The model number provides specific information about the unit. Here is a breakdown:

Position Code Description
Brand DR Durastar
Product Category F Front Return
Stages Of Airflow 2 2-Stage
Motor Type T Constant Torque
Refrigerant A R-410A
Capacity 24 / 36 24,000 [7.03 kW] / 36,000 [10.55 kW]
Width 21 / 24 21″ / 24.5″
Major Series A 1st Design
Efficiency S Standard
Metering T TXV
Coil Series N N Coil
Voltage J 208-240/1/60
Disconnect B / N Breaker / None
Factory Heat 0 / 3 / 5 / 8 / 1 No Heat / 3 kW / 5 kW / 8 kW / 10 kW
Option Code F Float Switch

What are the unit dimensions and weights for the DURASTAR DRF2TA2421ASTNJB1F?

The dimensions and weights for the DURASTAR DRF2TA2421ASTNJB1F are as follows:

Specification Measurement (Inches [mm])
Unit Width 21 1/2 [546.1]
Unit Height 36 [914.4]
Unit Depth 17 [431.8]
Return Air Opening Width 20 [508.0]
Return Air Opening Height 17 7/16 [442.9]
Filter Size (in. x in. x in.) 20 X 20 X 1 [508 X 508 X 25.4]
Air Flow CFM (Nominal Low/High) 600 [283] / 800 [378]
Unit Weight/Shipping Weight (Lbs. [kg]) 95 [43] / 105 [48]

What are the airflow operating limits for the DURASTAR DRF2TA2421ASTNJB1F?

The airflow operating limits for the DURASTAR DRF2TA2421ASTNJB1F (Cabinet Size 21) are as follows. For optimum blower performance, operate the unit in the 0.3 to 0.7 inches W.C. external static range.

Parameter Value
Cooling BTUH x 1,000 24
Cooling Tons Nominal 2
Maximum Heat/Cool CFM [L/s] 900 [425]
Nominal Heat/Cool CFM [L/s] 800 [378]
Minimum Heat/Cool CFM [L/s] 720 [340]
Maximum kW Electric Heating 10
Minimum Electric Heat CFM [L/s] 690 [326]
Maximum Electric Heat Rise °F [°C] 44 [7]

What is the airflow performance data for the DURASTAR DRF2TA2421ASTNJB1F?

The following table shows the CFM dry delivery, RPM, and Watts at various external static pressures for the 2-ton model.

Motor Speed Measurement External Static Pressure – Inches W.C.
0.1 0.2 0.3 0.4 0.5 0.6 0.7
4 CFM 654 616 581 542 503 463 399
RPM 694 736 777 818 858 899 971
Watts 76.4 80.1 83.7 87.6 91.3 95.1 101.6
5 CFM 887 858 830 802 771 743 717
RPM 876 914 945 976 1014 1044 1070
Watts 156 161.8 166.8 171.5 177.5 182.3 186.2

NOTE: All DRF2TA air handlers have 5-speed constant torque motors.

• Speed tap 1 is for continuous fan.

• Speed tap 2 (low static) and speed tap 3 (high static) are for lower tonnage (1.5 tons).

• Speed tap 4 (low static) and speed tap 5 (high static) are for higher tonnage (2.0 tons).

• DRF2TA air handlers are always shipped from the factory at speed tap 5.

• The low static speed tap 4 is for external static pressures below 0.5″ WC. The high static speed tap 5 is used for external static exceeding 0.5″ WC. Move the blue wire to the appropriate speed tap on the motor terminal block as required by the application needs.

• The airflow for continuous fan (speed tap 1) is always set at 50% of the speed tap 4.


What are the electrical specifications for the blower motor on the DURASTAR DRF2TA2421ASTNJB1F?

The electrical data for the blower motor only (no electric heat) is as follows:

Voltage Phase Hertz HP [W] RPM Speeds Circuit Amps. Minimum Circuit Ampacity Maximum Circuit Protector
208/230 1 60 1/3 [249] 300-1100 4 1.9 3 15

What are the electrical specifications for the DURASTAR DRF2TA2421ASTNJB1F when using an electric heat kit?

When installing a U.L. Listed original equipment manufacturer provided heater kit, refer to the following electrical data. The table below applies to the DURASTAR DRF2TA2421ASTNJB1F (2 Ton capacity).

Heater Kit Model No. Heater kW PH/Hz No. Elements – kW Per (208/240V) Type Supply Circuit Circuit Amps. Motor Ampacity Minimum Circuit Ampacity Maximum Circuit Protection
RXHJ-21B/T03J 2.25/3.0 1/60 1-3.0 Single 10.8/12.5 1.9 16/18 20/20
RXHJ-21B/T05J 3.6/4.8 1/60 1-4.8 Single 17.3/20.0 1.9 0.9 25/30
RXHJ-21B/T08J 5.4/7.2 1/60 2-3.6 Single 26.0/30.0 1.9 35/40 35/40
RXHJ-21B/T10J 7.2/9.6 1/60 2-4.8 Single 34.6/40.0 1.9 0.9 50/60

Notes:

• Supply circuit protective devices may be fused or “HACR” type circuit breakers.

• If a non-standard fuse size is specified, use the next size larger standard fuse size.


What are the power wiring and grounding requirements for the DURASTAR DRF2TA2421ASTNJB1F?

Follow these requirements for electrical power wiring and grounding:

• Field wiring must comply with the National Electrical Code (C.E.C. in Canada) and any applicable local ordinances.

• This product must be sufficiently grounded in accordance with the National Electrical Code (C.E.C. in Canada) and any applicable local ordinances.

• Supply wiring must be 75°C minimum copper conductors only.

• A grounding lug is provided.


What optional accessories, kits, and parts are available for the DURASTAR DRF2TA2421ASTNJB1F?

The following accessories, kits, and parts are available for the DURASTAR DRF2TA2421ASTNJB1F:

Drain Pan Over Flow Switch RXHK-A01: This switch detects condensate drain blockage and shuts down the outdoor unit to prevent water damage.

Bottom Return Conversion Kit RXHK-B01: This kit is used to divert the return air from the standard front return to a bottom return configuration.

Louvered Cabinet Grill RXHK-C01: This is a decorative grill that covers the return air opening of the front return air handler.

Decorative Wall Grill RXHK-D01 or RXHK-D02: These grills are used when the air handler is installed in a closet or interior wall, allowing adequate return air back to the unit.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD DURASTAR DRF2TA2421ASTNJB1F (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.