What are the features and benefits of the DURASTAR DRF2TA2421ASTNJB3 air handler?
The DURASTAR DRF2TA2421ASTNJB3 air handler includes the following features and benefits:
• Front or Bottom Return with aluminum tube and fin coil
• TXV for cooling or heat pump operation
• Wall-hanging brackets
• Built in Filter Rack
• Molex Plug Connections for field installed heater kits
• Dual Voltage Direct Drive Blower with multi-speed motor
• Thermoplastic Drain Pan with bottom primary and secondary connections
• Optional Decorative Grill for front return applications
• Optional Factory Installed Condensate Float Switch which shuts off the outdoor unit in the event the condensate pan becomes clogged
• Cabinet air leakage less than 2% at 1 inch H2O when tested in accordance with ASHRAE Standard 193
• Can be field wired for single or two stage applications
What standard equipment is included with the DURASTAR DRF2TA2421ASTNJB3?
The standard equipment for the DURASTAR DRF2TA2421ASTNJB3 includes:
• Exclusive Incoloy sheath type electric heating elements
• Field convertible air supply
• Durable framed cleanable air filter
• Indoor coil design provides low air side pressure drop, high performance and compact size
• PVC condensate elbow is standard on all coils
• All indoor coils have aluminum tubing and aluminum fins
• Molded polymer corrosion resistant condensate drain pan
• Supply and return duct flanges
• High and low voltage connection points inside cabinet
• Concentric knockouts provided for power connection with hole size up to 2 inches [51 mm] for 1 1/2 inch [38mm] conduit
• Internal checked TX valves for quiet refrigerant metering
• Front refrigerant and drain connection
How is the model number of the DURASTAR DRF2TA2421ASTNJB3 decoded?
The model number provides specific details about the unit’s configuration:
| Code | Category | Description |
|---|---|---|
| DR | Brand | DR – Durastar |
| F | Product Category | F – Front Return |
| 2 | Stages Of Airflow | 2 – 2-Stage |
| T | Motor Type | T – Constant Torque |
| A | Refrigerant | A – R-410A |
| 24 | Capacity | 24 – 24,000 [7.03 kW] |
| 21 | Width | 21 – 21″ |
| A | Major Series | A – 1st Design |
| S | Efficiency | S – Standard |
| T | Metering | T – TXV |
| N | Coil Series | N – N Coil |
| J | Voltage | J – 208-240/1/60 |
| B | Disconnect | B – Breaker |
| 3 | Factory Heat | 3 – 3 kW |
| (Blank) | Option Code | None (Model shown is an example that has a float switch ‘F’) |
What are the physical dimensions, weight, and filter size for the DURASTAR DRF2TA2421ASTNJB3?
| Model | (A) Unit Width In. [mm] | (B) Unit Height In. [mm] | (C) Unit Depth In. [mm] | (D) Return Air Opening Width In. [mm] | (E) Return Air Opening Height In. [mm] | Filter Size in. x in. x in. [mm x mm x mm] | Air Flow CFM (Nom.) [L/s] Low/High | Unit Weight/Shipping Weight (Lbs.) [kg] |
|---|---|---|---|---|---|---|---|---|
| DRF2TA2421 | 21 1/2 [546.1] | 36 [914.4] | 17 [431.8] | 20 [508.0] | 17 7/16 [442.9] | 20 X 20 X 1 [508 X 508 X 25.4] | 600 [283] / 800 [378] | 95 [43] / 105 [48] |
What is the required installation orientation for the DURASTAR DRF2TA2421ASTNJB3?
All units are configured for vertical upflow only. The DURASTAR DRF2TA2421ASTNJB3 cannot be installed in any other configuration.
What are the airflow operating limits for the DURASTAR DRF2TA2421ASTNJB3 air handler?
| Parameter | Value (Model Cabinet Size 21) |
|---|---|
| Cooling BTUH x 1,000 | -24 |
| Cooling Tons Nominal | 2 |
| Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] | 900 [425] |
| Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] | 800 [378] |
| Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] | 720 [340] |
| Maximum kW Electric Heating & Minimum Electric Heat CFM [L/s] | 10 690 [326] |
| Maximum Electric Heat Rise °F [°C] | 44 [7] |
How should the DURASTAR DRF2TA2421ASTNJB3 be operated for optimum blower performance?
Airflow performance data is based on cooling performance with a coil and no filter in place. For optimum blower performance, operate the unit in the .3 [8 mm] to .7 inches [18 mm] W.C. external static range. Units with coils should be applied with a minimum of .1 inch [3 mm] W.C. external static range. Ensure the external static applied to the unit allows operation within the minimum and maximum limits shown in the Airflow Operating Limits table.
What is the airflow performance data for the DURASTAR DRF2TA2421ASTNJB3 (2 Tons)?
The unit uses a 10×6 1/3 Hp, 2-speed dual voltage motor. The performance data at various external static pressures is as follows:
| Motor Speed | Parameter | External Static Pressure-Inches W.C. | ||||||
|---|---|---|---|---|---|---|---|---|
| 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | ||
| 4 | CFM | 654 | 616 | 581 | 542 | 503 | 463 | 399 |
| RPM | 694 | 736 | 777 | 818 | 858 | 899 | 971 | |
| Watts | 76.4 | 80.1 | 83.7 | 87.6 | 91.3 | 95.1 | 101.6 | |
| 5 | CFM | 887 | 858 | 830 | 802 | 771 | 743 | 717 |
| RPM | 876 | 914 | 945 | 976 | 1014 | 1044 | 1070 | |
| Watts | 156 | 161.8 | 166.8 | 171.5 | 177.5 | 182.3 | 186.2 | |
How are the 5-speed constant torque motor taps configured on the DURASTAR DRF2TA2421ASTNJB3?
The DURASTAR DRF2TA2421ASTNJB3 air handler has a 5-speed constant torque motor with specific configurations for each speed tap:
• Speed tap 1 is for continuous fan. The airflow for continuous fan is always set at 50% of the speed tap 4 airflow.
• Speed tap 2 (low static) and speed tap 3 (high static) are for lower tonnage applications (1.5 or 2.5 tons).
• Speed tap 4 (low static) and speed tap 5 (high static) are for higher tonnage applications (2.0 or 3.0 tons).
The unit is always shipped from the factory at speed tap 5.
The low static speed taps (2 and 4) are for external static pressures below 0.5″ WC. The high static speed taps (3 and 5) are used for external static exceeding 0.5″ WC. To change the speed, move the blue wire to the appropriate speed tap on the motor terminal block as required by the application.
What are the electrical specifications for the blower motor only on the DURASTAR DRF2TA2421ASTNJB3?
The electrical data for the blower motor without an electric heat kit is as follows:
| Model/Nominal Cooling Tons | Voltage | Phase | Hertz | HP [W] | RPM | Speeds | Circuit Amps. | Minimum Circuit Ampacity | Maximum Circuit Protector |
|---|---|---|---|---|---|---|---|---|---|
| DRF2TA2421 | 208/230 | 1 | 60 | 1/3 [249] | 300-1100 | 4 | 1.9 | 3 | 15 |
*Blower motors are all single phase motors.
What are the electrical specifications for the DURASTAR DRF2TA2421ASTNJB3 with compatible electric heat kits?
Installation of U.L. Listed original equipment manufacturer provided heater kits is recommended for all auxiliary heating requirements. The specifications for compatible heater kits are below.
| Heater Kit Model No. | Heater kW (208/240V) | PH/Hz | No. Elements – kW Per | (208/240V) Type Supply Circuit | Circuit Amps. | Motor Ampacity | Minimum Circuit Ampacity | Maximum Circuit Protection |
|---|---|---|---|---|---|---|---|---|
| RXHJ-21B/T03J | 2.25/3.0 | 1/60 | 1-3.0 | Single | 10.8/12.5 | 1.9 | 16/18 | 20/20 |
| RXHJ-21B/T05J | 3.6/4.8 | 1/60 | 1-4.8 | Single | 17.3/20.0 | 1.9 | 0.9 | 25/30 |
| RXHJ-21B/T08J | 5.4/7.2 | 1/60 | 2-3.6 | Single | 26.0/30.0 | 1.9 | 35/40 | 35/40 |
| RXHJ-21B/T10J | 7.2/9.6 | 1/60 | 2-4.8 | Single | 34.6/40.0 | 1.9 | 0.9 | 50/60 |
Notes:
• Electric heater BTUH = (heater watts + motor watts) x 3.414.
• J voltage (230V) single phase air handler is designed to be used with single or three phase.
• Supply circuit protective devices may be fused or “HACR” type circuit breakers.
• If non-standard fuse size is specified, use next size larger standard fuse size. Without the heater, bring only two leads to terminal block, cap, insulate and fully secure the third lead.
• Largest motor load is included in single circuit or circuit 1 of multiple circuits.
• Do not use 480 volts electrical heaters on 230 volts air handler.
What are the power wiring and grounding requirements for the DURASTAR DRF2TA2421ASTNJB3?
• Field wiring must comply with the National Electrical Code.
• This product must be sufficiently grounded in accordance with (C.E.C. in Canada) and any applicable local ordinance.
• Supply wiring must be 75°C minimum copper conductors only.
• See electrical data for product Ampacity rating and Circuit Protector requirement.
• A grounding lug is provided.
What optional accessories and kits are available for the DURASTAR DRF2TA2421ASTNJB3?
The following accessories and kits are available for the DURASTAR DRF2TA2421ASTNJB3:
• Drain Pan Over Flow Switch RXHK-A01: This switch detects condensate drain blockage and shuts down the outdoor unit to prevent structural damage.
• Bottom Return Conversion Kit RXHK-B01: Used to divert the return air from the factory standard front return to a bottom return.
• Louvered Cabinet Grill RXHK-C01: A decorative grill that covers the return air opening of the front return air handler.
• Decorative Wall Grill RXHK-D01: Used in applications where the air handler is installed in a closet or interior wall to allow adequate return air back to the unit. The dimensions are 23 3/4″ [603 mm] to 24″ [610 mm] O.C. for D01 and 26 5/8″ [676 mm] width for D01.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD DURASTAR DRF2TA2421ASTNJB3 (01) PDF DOCUMENT