FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL (01) PDF DOCUMENT.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL (01) PDF USER GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL (01) PDF USER MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL (01) PDF OWNER GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL (01) PDF OWNER MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL (01) PDF REFERENCE GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL (01) PDF REFERENCE MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD AUTOMATIONDIRECT C-MORE EA9-T6CL (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What should I do after unpacking the AUTOMATIONDIRECT C-MORE EA9-T6CL?
After unpacking your AUTOMATIONDIRECT C-MORE EA9-T6CL, you should inspect all equipment for completeness. The following items should be included:
• Quick Start Guide
• Cutout Template*
• C-more Panel
• Gasket
• DC power connector
• Mounting Clips
• Logo Label*
*Note: The Cutout Template and Logo Label are not included with models EA9-T7CL-R and EA9-T7CL.
If anything is missing or damaged, you should immediately contact the returns department.
How do I provide DC power to the AUTOMATIONDIRECT C-MORE EA9-T6CL?
To power the AUTOMATIONDIRECT C-MORE EA9-T6CL, wire a dedicated 12-24 VDC power source to the DC connector on the rear of the panel. It is important to also wire the ground terminal to a proper equipment ground.
Use 60/75°C copper conductors only, with a wire gauge of 12-24 AWG.
The recommended DC supply fuses are:
| Panel Size | Rating | ADC p/n |
|---|---|---|
| 6″ – 10″ | 2.5 A | MDL2-5 |
| 12″ & 15″ | 4.0 A | MDL4 |
The tightening torque specifications for the DC connector are:
| Component | Torque Value |
|---|---|
| Power connector screw torque | 70.4 oz-in (0.5 Nm) |
| Power connector mounting torque | 56 oz-in (0.4 Nm) |
After wiring, turn on the power source and check the LED status indicators for proper indication.
How can I power the AUTOMATIONDIRECT C-MORE EA9-T6CL using an AC power source?
To use an AC power source, you must install a C-more AC/DC Power Adapter (p/n EA-AC) to the rear of the AUTOMATIONDIRECT C-MORE EA9-T6CL touch panel. Wire an AC voltage source of 100-240 VAC, 50/60 Hz, to its AC connector. A recommended 3.0A time delay AC supply fuse (ADC p/n: MDL3) should be used.
The tightening torque specifications for the AC adapter are:
| Component | Torque Value |
|---|---|
| Power supply cable torque | 71-85 oz-in (0.5-0.6 Nm) |
| Power connector mounting torque | 71-85 oz-in (0.5-0.6 Nm) |
| Mounting flange screw torque | 57-71 oz-in (0.4-0.5 Nm) |
After installation, turn on the power source and check the LED status indicators for proper indication.
What do the CPU Status LED indicators on the AUTOMATIONDIRECT C-MORE EA9-T6CL mean?
The CPU Status LED on the rear of the AUTOMATIONDIRECT C-MORE EA9-T6CL indicates the operational state of the panel. The meanings of the different colors and patterns are as follows:
| LED State | Meaning |
|---|---|
| Off | Power Off |
| Green | Normal – CPU Run State |
| Red | Memory Error |
| Blinking Red | Watchdog Timer Error |
| Blinking Orange | OS Error |
| Blinking Green | Power Loss Detection |
What does the Power LED on the front of the AUTOMATIONDIRECT C-MORE EA9-T6CL indicate?
The Power LED on the front bezel of the AUTOMATIONDIRECT C-MORE EA9-T6CL indicates the panel’s power status.
| Color | State | Meaning |
|---|---|---|
| Green | On | Power On |
| Off | Power Error |
What are the installation and mounting requirements for the AUTOMATIONDIRECT C-MORE EA9-T6CL?
When installing the AUTOMATIONDIRECT C-MORE EA9-T6CL into an enclosure, the following guidelines must be followed:
Cutout Dimensions:
| Model | A | B | D | E | J |
|---|---|---|---|---|---|
| EA9-T6CL-R / EA9-T6CL | 8.08 in [205.2 mm] | 6.13 in [155.8 mm] | 7.46 in [189.5 mm] | 5.51 in [140.0 mm] | 0.31 in [7.9 mm] |
Clearance:
A minimum clearance of 4 inches must be maintained from the top, bottom, and sides of the panel. A minimum clearance of 1.72 inches must be maintained from the rear of the panel.
Mounting Clip Torque:
The panel should be mounted in an enclosure with a thickness between 0.039 – 0.20 inches (1 – 5 mm). The mounting clip screws should be tightened to a torque of 63 – 77 oz-in (0.45 – 0.55 Nm).
The AUTOMATIONDIRECT C-MORE EA9-T6CL may be mounted at any angle without derating consideration.
What are the hazardous location installation requirements for the AUTOMATIONDIRECT C-MORE EA9-T6CL?
The AUTOMATIONDIRECT C-MORE EA9-T6CL is suitable for use in Class I, Division 2, Groups A, B, C and D hazardous locations, or nonhazardous locations only. The following requirements must be followed:
WARNING – EXPLOSION HAZARD: Do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous.
WARNING – EXPLOSION HAZARD: Substitution of any components may impair suitability for Class I, Division 2.
Devices shall be installed into an enclosure that utilizes a tool removable door/cover.
How should I clean and operate the touchscreen of the AUTOMATIONDIRECT C-MORE EA9-T6CL?
Cleaning:
The display screen should be cleaned periodically by wiping it with a lint-free damp cloth using a mild soap solution. Use a dry or slightly dampened cloth to wipe any dirt from the labels on the back of the panel. Dry all surfaces with a lint-free cloth. Do not clean with ammonia-based products, as they are solvents and will damage the face of the panel and the labels.
Operation:
The touchscreen is designed to respond to a single touch. If it is touched at multiple points at the same time, an unexpected object may be activated.
What are the key specifications for the AUTOMATIONDIRECT C-MORE EA9-T6CL?
| Power Consumption | 16.0 W (1.30A @ 12 VDC, 0.66A @ 24 VDC) |
| Internal Fuse (non-replaceable) | 4.0A |
| Altitude | Up to 2000m (6562 ft) |
| Operating Temperature | 0 to 50 °C (32 to 122 °F) |
| Storage Temperature | -20 to +60 °C (-4 to +140 °F) |
| Humidity | 5-95% RH (non-condensing) |
| Environment | For use in Pollution Degree 2 environment, no corrosive gases permitted |
| Withstand Voltage | 1000 VAC, 1 min. (FG to Power supply) |
| Insulation Resistance | > 10M ohm @ 500V DC (FG to Power supply) |
| Enclosure | NEMA 250 type 4/4X indoor use only, UL50 type 4X indoor use only, IP65 indoor use only (When mounted correctly) |
| Agency Approvals | UL508, E157382 Class 1, Div 2, Groups A, B, C; CE (EN61131-2), RoHS (2011/65/EU); CUL Canadian C22.2 |
What are the UL satisfaction ratings for the AUTOMATIONDIRECT C-MORE EA9-T6CL?
Input Ratings: 12-24 VDC, Class 2, SELV or LEC, Maximum 16.0W
Terminal connecting wire size: 12-24 AWG
Connecting torque: 71 – 85 oz-in (0.5 – 0.6 Nm)
Surrounding Air Temperature rating: 0 to 50°C (32 to 122°F)
Environment: For use in Pollution Degree 2 environment
All interface ports are intended to be directly connected to an isolated secondary circuit.
For use on a flat surface of a type 4X Indoor Use Only enclosure.
What important safety information should I know before operating the AUTOMATIONDIRECT C-MORE EA9-T6CL?
To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. It is your responsibility to determine which codes should be followed and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes.
Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.