FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T10WCL (01) PDF DOCUMENT.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T10WCL (01) PDF USER GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T10WCL (01) PDF USER MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T10WCL (01) PDF OWNER GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T10WCL (01) PDF OWNER MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T10WCL (01) PDF REFERENCE GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T10WCL (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T10WCL (01) PDF REFERENCE MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T10WCL (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T10WCL (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD AUTOMATIONDIRECT C-MORE EA9-T10WCL (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What should I do when I first unpack my AUTOMATIONDIRECT C-MORE EA9-T10WCL?
You should inspect all equipment for completeness. The package for the AUTOMATIONDIRECT C-MORE EA9-T10WCL should contain the following items:
• C-more Panel
• Quick Start Guide
• Cutout Template*
• Gasket
• DC power connector
• Mounting Clips
• Logo Label*
*Not included with EA9-T7CL-R and EA9-T7CL.
If anything is missing or damaged, you should immediately call the AutomationDirect returns department.
How do I provide DC power to my AUTOMATIONDIRECT C-MORE EA9-T10WCL?
To provide DC power to the AUTOMATIONDIRECT C-MORE EA9-T10WCL, follow these steps:
1. Wire a dedicated 12-24 VDC power source to the DC connector on the rear of the C-more touch panel.
2. Include wiring for the ground terminal to a proper equipment ground.
3. Turn on the power source and check the LED status indicators on the front and rear of the panel for proper indication.
Use 60 / 75°C copper conductors only, with a wire gauge of 12 – 24 AWG.
What are the recommended DC supply fuses for the AUTOMATIONDIRECT C-MORE EA9-T10WCL series panels?
The recommended DC supply fuse depends on the panel size:
| Panel Size | Rating | ADC p/n |
|---|---|---|
| 6″ – 10″ | 2.5 A | MDL2.5 |
| 12″ & 15″ | 4.0 A | MDL4 |
What are the DC power connector tightening torques for the AUTOMATIONDIRECT C-MORE EA9-T10WCL?
The tightening torque specifications for the DC power connector are as follows:
| DC-CON Tightening Torque | Value |
|---|---|
| Power connector screw torque | 70.4 oz-in (0.5 Nm) |
| Power connector mounting torque | 56 oz-in (0.4 Nm) |
How do I power the AUTOMATIONDIRECT C-MORE EA9-T10WCL with an AC source?
To power the panel with an AC source, you must use the optional C-more AC/DC Power Adapter (p/n EA-AC). Follow these steps:
1. Install the C-more AC/DC Power Adapter to the rear of the touch panel.
2. Wire an AC voltage source of 100-240 VAC, 50/60 Hz, to its AC connector.
3. It is recommended to use a 3.0A time delay AC supply fuse (ADC p/n: MDL3).
4. Turn on the power source and check the LED status indicators for proper indication.
What are the tightening torques for the optional EA-AC power adapter used with the AUTOMATIONDIRECT C-MORE EA9-T10WCL?
The tightening torque specifications for the EA-AC adapter are as follows:
| EA-AC Tightening Torque | Value |
|---|---|
| Power supply cable torque | 71-85 oz-in (0.5-0.6 Nm) |
| Power connector mounting torque | 71-85 oz-in (0.5-0.6 Nm) |
| Mounting flange screw torque | 57-71 oz-in (0.4-0.5 Nm) |
How do I interpret the CPU Status LED on the AUTOMATIONDIRECT C-MORE EA9-T10WCL?
The CPU Status LED (Green, Orange & Red) indicates the operational state of the panel’s CPU. The meanings are as follows:
| LED State | Status |
|---|---|
| Off | Power Off |
| Green | Normal – CPU Run State |
| Red | Memory Error |
| Blinking Red | Watchdog Timer Error |
| Blinking Orange | OS Error |
| Blinking Green | Power Loss Detection |
What does the Power LED on the front of the AUTOMATIONDIRECT C-MORE EA9-T10WCL indicate?
The green Power LED on the front of the panel indicates the power status:
| Color | On | Off |
|---|---|---|
| Green | Power On | Power Error |
What are the key safety warnings for the AUTOMATIONDIRECT C-MORE EA9-T10WCL?
To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. It is your responsibility to determine which codes should be followed and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes. Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
What are the technical specifications for the AUTOMATIONDIRECT C-MORE EA9-T10WCL?
| Specification | Value |
|---|---|
| Power Consumption | 17.0 W (1.42A @ 12 VDC, 0.71A @ 24 VDC) |
| Internal Fuse (non-replaceable) | 6.3A |
| Altitude | Up to 2000m (6562 ft) |
| Operating Temperature | 0 to 50 °C (32 to 122 °F); Surrounding Air Temperature and a range rating: 50 °C (122 °F) |
| Storage Temperature | -20 to +60 °C (-4 to +140 °F) |
| Humidity | 5-95% RH (non-condensing) |
| Environment | For use in Pollution Degree 2 environment, no corrosive gases permitted |
| Withstand Voltage | 1000 VAC, 1 min. (FG to Power supply) |
| Insulation Resistance | > 10M ohm @ 500V DC (FG to Power supply) |
| Enclosure | NEMA 250 type 4/4X indoor use only, UL50 type 4X indoor use only, IP65 indoor use only (When mounted correctly) |
| Agency Approvals | UL508, E157382, CE (EN61131-2), RoHS (2011/65/EU), CUL Canadian C22.2 |
What are the panel cutout dimensions for the AUTOMATIONDIRECT C-MORE EA9-T10WCL?
The cutout dimensions for the AUTOMATIONDIRECT C-MORE EA9-T10WCL are as follows:
| Model | A | B | D (Cutout) | E (Cutout) | J |
|---|---|---|---|---|---|
| EA9-T10WCL | 11.18 in [284.0 mm] | 7.69 in [195.4 mm] | 9.25 in [235.0 mm] | 7.07 in [179.6 mm] | 0.96 in [24.5 mm] |
What are the installation clearance requirements for the AUTOMATIONDIRECT C-MORE EA9-T10WCL?
When installing the AUTOMATIONDIRECT C-MORE EA9-T10WCL in an enclosure or cabinet, the mounting clearances shall be a minimum of 4 inches from the top, bottom and sides, and 1.72 inches from the rear.
What are the enclosure thickness and mounting clip torque specifications for the AUTOMATIONDIRECT C-MORE EA9-T10WCL?
The requirements for mounting the AUTOMATIONDIRECT C-MORE EA9-T10WCL are as follows:
| Touch Panel Size | Enclosure Thickness Range | Mounting Clip Screw Torque | Material |
|---|---|---|---|
| 10″W | 0.039 – 0.20 inch [1 – 5 mm] | 92 – 106 oz-in [0.65 – 0.75 Nm] | Metal |
How should I clean the AUTOMATIONDIRECT C-MORE EA9-T10WCL?
The display screen should be cleaned periodically by wiping it with a lint-free damp cloth using a mild soap solution. Use a dry or slightly dampened cloth to wipe any dirt from the labels on the back of the panel. Dry all surfaces with a lint-free cloth. Do not clean with ammonia-based products which are solvents and will damage the face of the panel and the labels.
What is an important operational note regarding the touchscreen of the AUTOMATIONDIRECT C-MORE EA9-T10WCL?
The touchscreen is designed to respond to a single touch. If it is touched at multiple points at the same time, an unexpected object may be activated.
What are the UL satisfaction and input ratings for the AUTOMATIONDIRECT C-MORE EA9-T10WCL?
The UL ratings for the AUTOMATIONDIRECT C-MORE EA9-T10WCL are:
• Input Rating: 12-24 VDC, Class 2, SELV or LEC, Maximum 17.0W
• Terminal connecting wire size: 12-24 AWG
• Connecting torque: 71 – 85 oz-in (5-7 lbf-in) (0.5 – 0.6 Nm)
• Surrounding Air Temperature rating: 0 to 50°C (32 to 122°F)
• For use in Pollution Degree 2 environment
• All interface ports are intended to be directly connected to an isolated secondary circuit
• For use on a flat surface of a type 4X Indoor Use Only enclosure
CLICK HERE TO DOWNLOAD AUTOMATIONDIRECT C-MORE EA9-T10WCL (01) PDF DOCUMENT