AUTOMATIONDIRECT C-MORE EA9-T6CL-R (01) Image

FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL-R (01) PDF DOCUMENT.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL-R (01) PDF USER GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL-R (01) PDF USER MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL-R (01) PDF OWNER GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL-R (01) PDF OWNER MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL-R (01) PDF REFERENCE GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL-R (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL-R (01) PDF REFERENCE MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL-R (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T6CL-R (01) PDF OPERATING INSTRUCTIONS.


CLICK HERE TO DOWNLOAD AUTOMATIONDIRECT C-MORE EA9-T6CL-R (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What should I do after unpacking the AUTOMATIONDIRECT C-MORE EA9-T6CL-R?

After unpacking your AUTOMATIONDIRECT C-MORE EA9-T6CL-R, you should inspect all equipment for completeness. The package should contain:

• Quick Start Guide

• Cutout Template (Not included with EA9-T7CL-R and EA9-T7CL)

• C-more Panel

• Gasket

• DC power connector

• Mounting Clips

• Logo Label (Not included with EA9-T7CL-R and EA9-T7CL)

If anything is missing or damaged, please contact the AutomationDirect returns department immediately.


How do I provide DC power to the AUTOMATIONDIRECT C-MORE EA9-T6CL-R?

To provide DC power to the AUTOMATIONDIRECT C-MORE EA9-T6CL-R, follow these steps:

1. Wire a dedicated 12-24 VDC power source to the DC connector on the rear of the panel.

2. Include wiring for the ground terminal (GND) to a proper equipment ground.

3. Use 60/75°C copper conductors only, with a wire gauge of 12-24 AWG.

4. Turn on the power source and check the LED status indicators for proper indication.

Recommended DC Supply Fuse:

Panel Size Rating ADC p/n
6″ – 10″ 2.5 A MDL2.5
12″ & 15″ 4.0 A MDL4

DC-CON Tightening Torque:

Power connector screw torque 70.4 oz-in (0.5 Nm)
Power connector mounting torque 56 oz-in (0.4 Nm)

How can I power the AUTOMATIONDIRECT C-MORE EA9-T6CL-R using an AC power source?

To power the AUTOMATIONDIRECT C-MORE EA9-T6CL-R with an AC source, you must use the optional C-more AC/DC Power Adapter (p/n EA-AC).

1. Install the EA-AC adapter to the rear of the touch panel.

2. Wire an AC voltage source of 100-240 VAC, 50/60 Hz, to the adapter’s AC connector.

3. It is recommended to use a 3.0A time delay AC supply fuse (ADC p/n: MDL3).

4. Turn on the power source and check the LED status indicators for proper indication.

EA-AC Tightening Torque:

Power supply cable torque 71-85 oz-in (0.5-0.6 Nm)
Power connector mounting torque 71-85 oz-in (0.5-0.6 Nm)
Mounting flange screw torque 57-71 oz-in (0.4-0.5 Nm)

What do the CPU Status LED indicators on the AUTOMATIONDIRECT C-MORE EA9-T6CL-R mean?

The CPU Status LED (Green, Orange & Red) on the rear of the AUTOMATIONDIRECT C-MORE EA9-T6CL-R indicates the operational state of the unit. The meanings are as follows:

LED State Status
Off Power Off
Green Normal – CPU Run State
Red Memory Error
Blinking Red Watchdog Timer Error
Blinking Orange OS Error
Blinking Green Power Loss Detection

What does the Power LED on the front of the AUTOMATIONDIRECT C-MORE EA9-T6CL-R indicate?

The Power LED on the front of the AUTOMATIONDIRECT C-MORE EA9-T6CL-R indicates the power status of the panel.

Color State Meaning
Green On Power On
Green Off Power Error

What are the panel mounting instructions for the AUTOMATIONDIRECT C-MORE EA9-T6CL-R?

To mount the AUTOMATIONDIRECT C-MORE EA9-T6CL-R, you must first create a cutout in your enclosure according to the dimensions specified for your model. Use the mounting brackets provided to secure the panel in the enclosure. Ensure you adhere to the specified screw torque for the mounting clips.

Cutout Dimensions – inches [mm]

Model A B D E J
EA9-T6CL-R
EA9-T6CL
8.08 [205.2] 6.13 [155.8] 7.46 [189.5] 5.51 [140.0] 0.31 [7.9]
EA9-T7CL-R
EA9-T7CL
9.87 [250.7] 7.69 [195.4] 9.25 [235.0] 7.07 [179.6] 0.31 [7.9]
EA9-T8CL
EA9-T10WCL 11.18 [284.0] 0.96 [24.5]
EA9-T10CL 12.52 [318.0] 9.53 [242.1] 11.90 [302.3] 8.91 [226.3] 0.31 [7.9]
EA9-T12CL 13.37 [339.6] 11.02 [280.0] 12.57 [319.3] 10.22 [259.6] 0.40 [10.2]
EA9-T15CL-R
EA9-T15CL
15.75 [400.0] 12.09 [307.2] 14.93 [379.2] 11.27 [286.3] 0.41 [10.4]

Mounting Clip Screw Torque

Touch Panel Size Enclosure Thickness Range Mounting Clip Screw Torque Material
6″, 7″, 8″, 10″ and 12″ 0.039 – 0.20 inch [1 – 5 mm] 63 – 77 oz-in [0.45 – 0.55 Nm] Metal
10″W, 15″ 92 – 106 oz-in [0.65 – 0.75 Nm]

What are the clearance requirements when installing the AUTOMATIONDIRECT C-MORE EA9-T6CL-R?

When installing the AUTOMATIONDIRECT C-MORE EA9-T6CL-R in an enclosure or cabinet, you must maintain the following minimum clearances:

Top, bottom, and sides: 4 inches

Rear: 1.72 inches

This ensures adequate space for ventilation and cable connections.


How should I clean the AUTOMATIONDIRECT C-MORE EA9-T6CL-R panel?

Follow these guidelines for cleaning your AUTOMATIONDIRECT C-MORE EA9-T6CL-R:

1. The display screen should be cleaned periodically by wiping it with a lint-free damp cloth using a mild soap solution.

2. Use a dry or slightly dampened cloth to wipe any dirt from the labels on the back of the panel.

3. Dry all surfaces with a lint-free cloth after cleaning.

4. Do not clean with ammonia-based products, as they are solvents and will damage the face of the panel and the labels.

Note: The touchscreen is designed to respond to a single touch. If it is touched at multiple points at the same time, an unexpected object may be activated.


What are the hazardous location installation requirements for the AUTOMATIONDIRECT C-MORE EA9-T6CL-R?

The AUTOMATIONDIRECT C-MORE EA9-T6CL-R is suitable for use in Class I, Division 2, Groups A, B, C, and D hazardous locations, or nonhazardous locations only. The following requirements must be met:

WARNING – EXPLOSION HAZARD: Do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous.

WARNING – EXPLOSION HAZARD: Substitution of any components may impair suitability for Class I, Division 2.

• Devices shall be installed into an enclosure that utilizes a tool removable door/cover.


What are the general safety warnings for the AUTOMATIONDIRECT C-MORE EA9-T6CL-R?

To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. It is your responsibility to determine which codes should be followed and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes.

Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation.

If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.


What are the technical specifications for the AUTOMATIONDIRECT C-MORE EA9-T6CL-R series panels?

Specification EA9-T6CL-R / EA9-T6CL EA9-T7CL-R / EA9-T7CL EA9-T8CL EA9-T10WCL EA9-T10CL EA9-T12CL EA9-T15CL-R / EA9-T15CL
Power Consumption 16.0 W
1.30A @ 12 VDC
0.66A @ 24 VDC
18.0 W
1.50A @ 12 VDC
0.75A @ 24 VDC
17.0 W
1.42A @ 12 VDC
0.71A @ 24 VDC
18.0 W
1.50A @ 12 VDC
0.75A @ 24 VDC
21.0 W
1.75A @ 12 VDC
0.88A @ 24 VDC
29.0 W
2.40A @ 12 VDC
1.20A @ 24 VDC
Internal Fuse (non-replaceable) 4.0A 6.3A
Altitude Up to 2000m (6562 ft)
Operating Temperature 0 to 50 °C (32 to 122 °F); Surrounding Air Temperature and a range rating: 50 °C (122 °F)
IEC 60068-2-14 (Test Nb, Thermal Shock)
Storage Temperature -20 to +60 °C (-4 to +140 °F)
IEC 60068-2-1 (Test Ab, Cold)
IEC 60068-2-2 (Test Bb, Dry Heat)
IEC 60068-2-14 (Test Na, Thermal Shock)
Humidity 5-95% RH (non-condensing)
Environment For use in Pollution Degree 2 environment, no corrosive gases permitted
Noise Immunity (EN61131-2)
EN61000-4-2 (ESD),
EN61000-4-3 (RFI)
EN61000-4-4 (FTB)
EN61000-4-5 (Surge)
EN61000-4-6 (Conducted)
EN61000-4-8 (Power frequency magnetic field immunity)
(Local Test)
RFI, (145MHz, 440MHz 10W @ 10cm)
Withstand Voltage Impulse 1000V @ 1us pulse
1000 VAC, 1 min. (FG to Power supply)
Insulation Resistance > 10M ohm @ 500V DC (FG to Power supply)
Vibration IEC60068-2-6 (Test Fc)
Shock IEC60068-2-27 (Test Ea)
Emission EN55011 Class A (Radiated RF emission)
Enclosure NEMA 250 type 4/4X indoor use only
UL50 type 4X indoor use only
IP65 indoor use only
(When mounted correctly)
NEMA 250 type 4/4X indoor use only
UL50 type 4X indoor use only
IP65 indoor use only (not tested by UL)
(When mounted correctly)
NEMA 250 type 4/4X indoor use only
UL50 type 4X indoor use only
IP65 indoor use only
(When mounted correctly)
Agency Approvals UL508, E157382 Class 1, Div 2, Groups A, B, C
CE (EN61131-2), RoHS (2011/65/EU)
CUL Canadian C22.2
UL61010, E157382
CE (EN61131-2), RoHS (2011/65/EU)
CUL Canadian C22.2
UL508, E157382
CE (EN61131-2), RoHS (2011/65/EU)
CUL Canadian C22.2

What are the UL input ratings for the AUTOMATIONDIRECT C-MORE EA9-T6CL-R and other EA9 series panels?

The UL satisfaction ratings for the AUTOMATIONDIRECT C-MORE EA9 series panels are as follows:

Model Number Input Ratings
EA9-T6CL-R
EA9-T6CL
12-24 VDC, Class 2, SELV or LVLC, Maximum 16.0W
EA9-T7CL-R
EA9-T7CL
12-24 VDC, Class 2, SELV or LVLC, Maximum 18.0W
EA9-T8CL
EA9-T10WCL 12-24 VDC, Class 2, SELV or LVLC, Maximum 17.0W
EA9-T10CL 12-24 VDC, Class 2, SELV or LVLC, Maximum 18.0W
EA9-T12CL 12-24 VDC, Class 2, SELV or LVLC, Maximum 21.0W
EA9-T15CL-R
EA9-T15CL
12-24 VDC, Class 2, SELV or LVLC, Maximum 29.0W

Additional rating information:

• Terminal connecting wire size 12-24 AWG

• Connecting torque 71-85 oz-in (5-7 lbf-in) (0.5-0.6 Nm)

• Surrounding Air Temperature rating 0 to 50°C (32 to 122°F)

• For use in Pollution Degree 2 environment

• All interface ports are intended to be directly connected to an isolated secondary circuit

• For use on a flat surface of a type 4X Indoor Use Only enclosure


Where can I find complete installation and safety information for the AUTOMATIONDIRECT C-MORE EA9-T6CL-R?

This document provides simplified installation instructions and specifications. For complete installation and safety information, you should download the EA9-USER-M User Manual.


CLICK HERE TO DOWNLOAD AUTOMATIONDIRECT C-MORE EA9-T6CL-R (01) PDF DOCUMENT