FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL (01) PDF DOCUMENT.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL (01) PDF USER GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL (01) PDF USER MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL (01) PDF OWNER GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL (01) PDF OWNER MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL (01) PDF REFERENCE GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL (01) PDF REFERENCE MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD AUTOMATIONDIRECT C-MORE EA9-T15CL (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What should I do after unpacking my AUTOMATIONDIRECT C-MORE EA9-T15CL?
After unpacking your AUTOMATIONDIRECT C-MORE EA9-T15CL, you should inspect all equipment for completeness. If anything is missing or damaged, you should take appropriate action. The package should contain the following items:
• Quick Start Guide
• Cutout Template*
• C-more Panel
• Gasket
• DC power connector
• Mounting Clips
• Logo Label*
*Not included with EA9-T7CL-R and EA9-T7CL.
How do I power the AUTOMATIONDIRECT C-MORE EA9-T15CL using a dedicated DC power source?
To power the AUTOMATIONDIRECT C-MORE EA9-T15CL with a dedicated DC power source, wire a 12-24 VDC power source to the DC connector on the rear of the panel. It is important to also wire the ground terminal to a proper equipment ground. After wiring, turn on the power source and check the LED status indicators for proper indication.
Note: Use 60 / 75°C copper conductors only, 12 – 24 AWG.
Recommended DC Supply Fuse:
| Panel Size | Rating | ADC p/n |
|---|---|---|
| 6″-10″ | 2.5 A | MDL2-5 |
| 12″ & 15″ | 4.0 A | MDL4 |
DC Connector Tightening Torque:
| Power connector screw torque | 70.4 oz-in (0.5 Nm) |
| Power connector mounting torque | 56 oz-in (0.4 Nm) |
How do I power the AUTOMATIONDIRECT C-MORE EA9-T15CL using an AC/DC Power Adapter?
To power the AUTOMATIONDIRECT C-MORE EA9-T15CL using an AC source, install a C-more AC/DC Power Adapter (p/n EA-AC) to the rear of the touch panel. Wire an AC voltage source of 100-240 VAC, 50/60 Hz, to its AC connector. The recommended AC supply fuse is a 3.0A time delay fuse (ADC p/n: MDL3). After connecting the power, turn on the power source and check the LED status indicators on the front and rear of the panel for proper indication.
EA-AC Tightening Torque:
| Power supply cable torque | 71-85 oz-in (0.5-0.6 Nm) |
| Power connector mounting torque | 71-85 oz-in (0.5-0.6 Nm) |
| Mounting flange screw torque | 57-71 oz-in (0.4-0.5 Nm) |
What do the status LEDs on the AUTOMATIONDIRECT C-MORE EA9-T15CL indicate?
The AUTOMATIONDIRECT C-MORE EA9-T15CL has a CPU Status LED and a Power LED that indicate its operational state.
CPU Status LED (Green, Orange & Red)
| Off | Power Off |
| Green | Normal – CPU Run State |
| Red | Memory Error |
| Blinking Red | Watchdog Timer Error |
| Blinking Orange | OS Error |
| Blinking Green | Power Loss Detection |
Power LED (Front of Panel)
| Color | On | Off |
|---|---|---|
| Green | Power On | Power Error |
What are the panel cutout dimensions for the AUTOMATIONDIRECT C-MORE EA9-T15CL?
The required panel cutout dimensions for the AUTOMATIONDIRECT C-MORE EA9-T15CL are as follows:
| Model | A | B | D | E | J |
|---|---|---|---|---|---|
| EA9-T15CL-R / EA9-T15CL | 15.75 in [400.0 mm] | 12.09 in [307.2 mm] | 14.93 in [379.2 mm] | 11.27 in [286.3 mm] | 0.41 in [10.4 mm] |
What are the installation clearance and temperature derating requirements for the AUTOMATIONDIRECT C-MORE EA9-T15CL?
Clearance:
When installing the AUTOMATIONDIRECT C-MORE EA9-T15CL in an enclosure or cabinet, a minimum clearance of 4 inches from the top, bottom, and sides, and 1.72 inches from the rear must be maintained.
Derating:
If the AUTOMATIONDIRECT C-MORE EA9-T15CL is mounted off the vertical plane facing upward, the operating temperature must be derated as follows:
• Angle 0° to 15°: Temperature must be 0 to 45 °C.
• Angle 15° to 90°: Temperature must be 0 to 50 °C.
If the EA-AC power adapter is used, the derating is as follows:
• Angle 0° to 45°: Temperature must be 0 to 40 °C.
• Angle 45° to 90°: Temperature must be 0 to 50 °C.
Where are the mounting bracket locations and what is the screw torque for the AUTOMATIONDIRECT C-MORE EA9-T15CL?
The AUTOMATIONDIRECT C-MORE EA9-T15CL uses 8 mounting bracket locations for a secure fit. The required torque for the mounting clip screws depends on the panel size.
| Touch Panel Size | Enclosure Thickness Range | Mounting Clip Screw Torque | Material |
|---|---|---|---|
| 10″W, 15″ | 0.039 – 0.20 inch [1 – 5 mm] | 92 – 106 oz-in [0.65 – 0.75 Nm] | Metal |
How should I clean and operate the touchscreen of the AUTOMATIONDIRECT C-MORE EA9-T15CL?
Cleaning:
The display screen should be cleaned periodically by wiping it with a lint-free damp cloth using a mild soap solution. Use a dry or slightly dampened cloth to wipe any dirt from the labels on the back of the panel. Dry all surfaces with a lint-free cloth. Do not clean with ammonia-based products which are solvents and will damage the face of the panel and the labels.
Operation:
The touchscreen is designed to respond to a single touch. If it is touched at multiple points at the same time, an unexpected object may be activated.
What are the UL satisfaction ratings and hazardous location requirements for the AUTOMATIONDIRECT C-MORE EA9-T15CL?
Input Ratings for AUTOMATIONDIRECT C-MORE EA9-T15CL:
• 12-24 VDC, Class 2, SELV or LEC, Maximum 29.0W
General Ratings and Requirements:
• Terminal connecting wire size: 12-24 AWG
• Connecting torque: 71 – 85 oz-in (0.5 – 0.6 Nm)
• Surrounding Air Temperature rating: 0 to 50°C (32 to 122°F)
• For use in Pollution Degree 2 environment
• All interface ports are intended to be directly connected to an isolated secondary circuit
• For use on a flat surface of a type 4X Indoor Use Only enclosure
Hazardous Location Installation Requirements (For specific models like EA9-T6CL-R and EA9-T6CL):
• SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D HAZARDOUS LOCATIONS, OR NONHAZARDOUS LOCATIONS ONLY.
• WARNING – EXPLOSION HAZARD – DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS.
• WARNING – EXPLOSION HAZARD – SUBSTITUTION OF ANY COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2.
• DEVICES SHALL BE INSTALLED INTO AN ENCLOSURE THAT UTILIZES A TOOL REMOVABLE DOOR/COVER.
What are the technical specifications for the AUTOMATIONDIRECT C-MORE EA9-T15CL?
| Specification | EA9-T15CL-R / EA9-T15CL |
| Power Consumption | 29.0 W (2.40A @ 12 VDC, 1.20A @ 24 VDC) |
| Internal Fuse (non-replaceable) | 6.3A |
| Altitude | Up to 2000m (6562 ft) |
| Operating Temperature | 0 to 50 °C (32 to 122 °F); Surrounding Air Temperature and a range rating: 50 °C (122 °F) |
| Storage Temperature | -20 to +60 °C (-4 to +140 °F) |
| Humidity | 5-95% RH (non-condensing) |
| Environment | For use in Pollution Degree 2 environment, no corrosive gases permitted (EN61131-2) |
| Noise Immunity | EN61000-4-2 (ESD), EN61000-4-3 (RFI), EN61000-4-4 (FTB), EN61000-4-5 (Surge), EN61000-4-6 (Conducted), EN61000-4-8 (Power frequency magnetic field immunity) |
| Withstand Voltage | 1000 VAC, 1 min. (FG to Power supply) |
| Insulation Resistance | > 10M ohm @ 500V DC (FG to Power supply) |
| Vibration | IEC60068-2-6 (Test Fc) |
| Shock | IEC60068-2-27 (Test Ea) |
| Emission | EN55011 Class A (Radiated RF emission) |
| Enclosure | NEMA 250 type 4/4X indoor use only, UL50 type 4X indoor use only, IP65 indoor use only (When mounted correctly) |
| Agency Approvals | UL508, E157382, CE (EN61131-2), RoHS (2011/65/EU), CUL Canadian C22.2 |
What are the primary safety warnings for the AUTOMATIONDIRECT C-MORE EA9-T15CL?
To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. It is your responsibility to determine which codes should be followed and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes.
Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. The products described are not guaranteed to be suitable for your particular application, and no responsibility is assumed for your product design, installation, or operation.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
CLICK HERE TO DOWNLOAD AUTOMATIONDIRECT C-MORE EA9-T15CL (01) PDF DOCUMENT