FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T8CL (01) PDF DOCUMENT.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T8CL (01) PDF USER GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T8CL (01) PDF USER MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T8CL (01) PDF OWNER GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T8CL (01) PDF OWNER MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T8CL (01) PDF REFERENCE GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T8CL (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T8CL (01) PDF REFERENCE MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T8CL (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T8CL (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD AUTOMATIONDIRECT C-MORE EA9-T8CL (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What should I do when I first receive my AUTOMATIONDIRECT C-MORE EA9-T8CL?
You should inspect all equipment for completeness. If anything is missing or damaged, you must immediately call the AutomationDirect returns department.
The package should contain:
• Quick Start Guide
• Cutout Template*
• C-more Panel
• Gasket
• DC power connector
• Mounting Clips
• Logo Label*
*Not included with EA9-T7CL-R and EA9-T7CL.
How do I provide DC power to the AUTOMATIONDIRECT C-MORE EA9-T8CL?
Wire a dedicated 12-24 VDC power source to the DC connector on the rear of the AUTOMATIONDIRECT C-MORE EA9-T8CL touch panel. Include wiring from the ground terminal to a proper equipment ground. After wiring, turn on the power source and check the LED status indicators for proper indication.
Use 60 / 75°C copper conductors only, 12 – 24 AWG.
Recommended DC Supply Fuse:
| Panel Size | Rating | ADC p/n |
|---|---|---|
| 6″ – 10″ | 2.5 A | MDL2-5 |
| 12″ & 15″ | 4.0 A | MDL4 |
DC-CON Tightening Torque:
| Power connector screw torque | 70.4 oz-in (0.5 Nm) |
| Power connector mounting torque | 56 oz-in (0.4 Nm) |
How do I provide AC power to the AUTOMATIONDIRECT C-MORE EA9-T8CL?
To use AC power, install a C-more AC/DC Power Adapter (p/n EA-AC) to the rear of the AUTOMATIONDIRECT C-MORE EA9-T8CL. Wire an AC voltage source of 100-240 VAC, 50/60 Hz, to its AC connector. A recommended AC supply fuse is a 3.0A time delay fuse (ADC p/n: MDL3). After wiring, turn on the power source and check the LED status indicators for proper indication.
EA-AC Tightening Torque:
| Power supply cable torque | 71-85 oz-in (0.5-0.6 Nm) |
| Power connector mounting torque | 71-85 oz-in (0.5-0.6 Nm) |
| Mounting flange screw torque | 57-71 oz-in (0.4-0.5 Nm) |
How can I interpret the CPU Status LED on my AUTOMATIONDIRECT C-MORE EA9-T8CL?
The CPU Status LED uses green, orange, and red colors to indicate the operational state of the AUTOMATIONDIRECT C-MORE EA9-T8CL. The different states are described in the table below:
| CPU Status LED (Green, Orange & Red) | Status |
|---|---|
| Off | Power Off |
| Green | Normal – CPU Run State |
| Red | Memory Error |
| Blinking Red | Watchdog Timer Error |
| Blinking Orange | OS Error |
| Blinking Green | Power Loss Detection |
What do the Power LED states on the front of the AUTOMATIONDIRECT C-MORE EA9-T8CL indicate?
The Power LED on the front of the panel indicates the power status. The states are as follows:
| Color | On | Off |
|---|---|---|
| Green | Power On | Power Error |
What are the general safety warnings for the AUTOMATIONDIRECT C-MORE EA9-T8CL?
To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. It is your responsibility to determine which codes should be followed and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes. Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
How do I mount the AUTOMATIONDIRECT C-MORE EA9-T8CL panel?
To mount the AUTOMATIONDIRECT C-MORE EA9-T8CL, use the provided cutout template to create an opening in your enclosure. Place the panel into the cutout and secure it using the mounting clips. Refer to the table below for cutout dimensions and required screw torque for the mounting clips.
Cutout Dimensions – inches [mm]
| Model | A | B | D | E | J |
|---|---|---|---|---|---|
| EA9-T6CL-R EA9-T6CL |
8.08 [205.2] | 6.13 [155.8] | 7.46 [189.5] | 5.51 [140.0] | 0.31 [7.9] |
| EA9-T7CL-R EA9-T7CL |
9.87 [250.7] | 7.69 [195.4] | 9.25 [235.0] | 7.07 [179.6] | 0.31 [7.9] |
| EA9-T8CL | |||||
| EA9-T10WCL | 11.18 [284.0] | 0.96 [24.5] | |||
| EA9-T10CL | 12.52 [318.0] | 9.53 [242.1] | 11.90 [302.3] | 8.91 [226.3] | 0.31 [7.9] |
| EA9-T12CL | 13.37 [339.6] | 11.02 [280.0] | 12.57 [319.3] | 10.22 [259.6] | 0.40 [10.2] |
| EA9-T15CL-R EA9-T15CL |
15.75 [400.0] | 12.09 [307.2] | 14.93 [379.2] | 11.27 [286.3] | 0.41 [10.4] |
Mounting Clip Screw Torque
| Touch Panel Size | Enclosure Thickness Range | Mounting Clip Screw Torque | Material |
|---|---|---|---|
| 6″, 7″, 8″, 10″ and 12″ | 0.039 – 0.20 inch [1 – 5 mm] | 63 – 77 oz-in [0.45 – 0.55 Nm] | Metal |
| 10″W, 15″ | 92 – 106 oz-in [0.65 – 0.75 Nm] |
Are there special installation considerations for the AUTOMATIONDIRECT C-MORE EA9-T8CL?
Yes, please note the following installation information:
Clearance: The mounting clearances when installing the touch panel in an enclosure or cabinet shall be a minimum of 4 inches from the top, bottom and sides and 1.72 inches from the rear.
Derating: If the EA9-T15CL model is mounted off the vertical plane facing upward, the temperature shall be derated. Other panels, including the AUTOMATIONDIRECT C-MORE EA9-T8CL, may be mounted at any angle without derating consideration.
How should I clean the AUTOMATIONDIRECT C-MORE EA9-T8CL panel?
The display screen should be cleaned periodically by wiping it with a lint-free damp cloth using a mild soap solution. Use a dry or slightly dampened cloth to wipe any dirt from the labels on the back of the panel. Dry all surfaces with a lint-free cloth. Do not clean with ammonia-based products which are solvents and will damage the face of the panel and the labels.
What should I know about using the touchscreen on the AUTOMATIONDIRECT C-MORE EA9-T8CL?
The touchscreen is designed to respond to a single touch. If it is touched at multiple points at the same time, an unexpected object may be activated.
What are the installation requirements for using the AUTOMATIONDIRECT C-MORE EA9-T8CL in a hazardous location?
For models EA9-T6CL-R and EA9-T6CL, the following requirements apply for hazardous locations:
• SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D HAZARDOUS LOCATIONS, OR NONHAZARDOUS LOCATIONS ONLY.
• WARNING – EXPLOSION HAZARD – DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS.
• WARNING – EXPLOSION HAZARD – SUBSTITUTION OF ANY COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2.
• DEVICES SHALL BE INSTALLED INTO AN ENCLOSURE THAT UTILIZES A TOOL REMOVABLE DOOR/COVER.
What are the UL satisfaction ratings and wiring specifications for the AUTOMATIONDIRECT C-MORE EA9-T8CL?
The UL satisfaction ratings and specifications for the AUTOMATIONDIRECT C-MORE EA9-T8CL are as follows:
Input Rating: 12 – 24 VDC, Class 2, SELV or LEC, Maximum 17.0W
Terminal connecting wire size: 12 – 24 AWG
Connecting torque: 71 – 85 oz-in (0.5 – 0.6 Nm)
Surrounding Air Temperature rating: 0 to 50°C (32 to 122°F)
Environment: For use in Pollution Degree 2 environment
All interface ports are intended to be directly connected to an isolated secondary circuit. For use on a flat surface of a type 4X Indoor Use Only enclosure.