AUTOMATIONDIRECT C-MORE EA9-T15CL-R (01) Image

FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL-R (01) PDF DOCUMENT.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL-R (01) PDF USER GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL-R (01) PDF USER MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL-R (01) PDF OWNER GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL-R (01) PDF OWNER MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL-R (01) PDF REFERENCE GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL-R (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL-R (01) PDF REFERENCE MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL-R (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH AUTOMATIONDIRECT C-MORE EA9-T15CL-R (01) PDF OPERATING INSTRUCTIONS.


CLICK HERE TO DOWNLOAD AUTOMATIONDIRECT C-MORE EA9-T15CL-R (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What should I do upon unpacking my AUTOMATIONDIRECT C-MORE EA9-T15CL-R?

After unpacking your AUTOMATIONDIRECT C-MORE EA9-T15CL-R, inspect all equipment for completeness. The package should contain:

• Quick Start Guide

• Cutout Template (Not included with EA9-T7CL-R and EA9-T7CL)

• C-more Panel

• Gasket

• DC power connector

• Mounting Clips

• Logo Label (Not included with EA9-T7CL-R and EA9-T7CL)

If anything is missing or damaged, you should immediately contact the returns department.


How do I provide DC power to the AUTOMATIONDIRECT C-MORE EA9-T15CL-R?

To power the AUTOMATIONDIRECT C-MORE EA9-T15CL-R with a DC source, follow these steps:

1. Wire a dedicated 12-24 VDC power source to the DC connector on the rear of the C-more touch panel.

2. Include wiring for the ground terminal to a proper equipment ground.

3. Turn on the power source and check the LED status indicators on the front and rear of the C-more touch panel for proper indication.

Note: Use 60 / 75°C copper conductors only, 12 – 24 AWG.


What are the recommended DC supply fuse ratings for the AUTOMATIONDIRECT C-MORE EA9-T15CL-R?

Panel Size Rating ADC p/n
6″ – 10″ 2.5 A MDL2.5
12″ & 15″ 4.0 A MDL4

What are the tightening torque specifications for the DC power connector on the AUTOMATIONDIRECT C-MORE EA9-T15CL-R?

Component Torque
Power connector screw torque 70.4 oz-in (0.5 Nm)
Power connector mounting torque 56 oz-in (0.4 Nm)

How can I provide AC power to the AUTOMATIONDIRECT C-MORE EA9-T15CL-R?

To use AC power, you must first install a C-more AC/DC Power Adapter (p/n EA-AC) to the rear of the touch panel.

1. Wire an AC voltage source of 100-240 VAC, 50/60 Hz, to its AC connector. A recommended 3.0A time delay fuse (ADC p/n: MDL3) should be used.

2. Turn on the power source and check the LED status indicators on the front and rear of the C-more touch panel for proper indication.


What are the tightening torque specifications for the optional EA-AC power adapter for the AUTOMATIONDIRECT C-MORE EA9-T15CL-R?

Component Torque
Power supply cable torque 71-85 oz-in (0.5-0.6 Nm)
Power connector mounting torque 71-85 oz-in (0.5-0.6 Nm)
Mounting flange screw torque 57-71 oz-in (0.4-0.5 Nm)

How do I interpret the CPU Status LED on the AUTOMATIONDIRECT C-MORE EA9-T15CL-R?

LED State Status
Off Power Off
Green Normal – CPU Run State
Red Memory Error
Blinking Red Watchdog Timer Error
Blinking Orange OS Error
Blinking Green Power Loss Detection

What does the Power LED on the front of the AUTOMATIONDIRECT C-MORE EA9-T15CL-R indicate?

Color On Off
Green Power On Power Error

What are the general safety warnings for the AUTOMATIONDIRECT C-MORE EA9-T15CL-R?

To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. It is your responsibility to determine which codes should be followed and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes.

Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation.

If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.


What are the operating environment specifications for the AUTOMATIONDIRECT C-MORE EA9-T15CL-R?

Altitude: Up to 2000m (6562 ft)

Operating Temperature: 0 to 50 °C (32 to 122 °F); Surrounding Air Temperature and a range rating: 50 °C (122 °F)

Storage Temperature: -20 to +60 °C (-4 to +140 °F)

Humidity: 5-95% RH (non-condensing)

Environment: For use in Pollution Degree 2 environment, no corrosive gases permitted (EN61131-2)


What are the required cutout dimensions for installing the AUTOMATIONDIRECT C-MORE EA9-T15CL-R?

Model Number A B D E J
EA9-T6CL-R, EA9-T6CL 8.08 [205.2] 6.13 [155.8] 7.46 [189.5] 5.51 [140.0] 0.31 [7.9]
EA9-T7CL-R, EA9-T7CL 9.87 [250.7] 7.69 [195.4] 9.25 [235.0] 7.07 [179.6] 0.31 [7.9]
EA9-T8CL
EA9-T10WCL 11.18 [284.0] 0.96 [24.5]
EA9-T10CL 12.52 [318.0] 9.53 [242.1] 11.90 [302.3] 8.91 [226.3] 0.31 [7.9]
EA9-T12CL 13.37 [339.6] 11.02 [280.0] 12.57 [319.3] 10.22 [259.6] 0.40 [10.2]
EA9-T15CL-R, EA9-T15CL 15.75 [400.0] 12.09 [307.2] 14.93 [379.2] 11.27 [286.3] 0.41 [10.4]

Dimensions are in inches [mm].


What are the installation clearance requirements for the AUTOMATIONDIRECT C-MORE EA9-T15CL-R?

When installing the touch panel in an enclosure or cabinet, there shall be a minimum clearance of 4 inches from the top, bottom, and sides, and 1.72 inches from the rear.


Are there any temperature derating considerations when mounting the AUTOMATIONDIRECT C-MORE EA9-T15CL-R?

Yes, if the AUTOMATIONDIRECT C-MORE EA9-T15CL-R is mounted off the vertical plane facing upward, the temperature shall be derated as follows. Other panel models may be mounted at any angle without derating consideration.

For EA9-T15CL-R and EA9-T15CL models:

• Angle 0° to -15°: Temp 0 to 45 °C

• Angle -15° to -90°: Temp 0 to 50 °C

• Angle 0° to -45°: Temp 0 to 40 °C

• Angle -45° to -90°: Temp 0 to 50 °C

For EA9-T15CL-R and EA9-T15CL models with EA-AC adapter:

• Angle 0° to 15°: Temp 0 to 45 °C

• Angle 15° to 90°: Temp 0 to 50 °C

• Angle 0° to 45°: Temp 0 to 40 °C

• Angle 45° to 90°: Temp 0 to 50 °C


What is the recommended screw torque for the mounting clips on the AUTOMATIONDIRECT C-MORE EA9-T15CL-R?

Touch Panel Size Enclosure Thickness Range Mounting Clip Screw Torque Material
6″, 7″, 8″, 10″ and 12″ 0.039 – 0.20 inch [1 – 5 mm] 63 – 77 oz-in [0.45 – 0.55 Nm] Metal
10″W, 15″ 92 – 106 oz-in [0.65 – 0.75 Nm]

How should I clean the AUTOMATIONDIRECT C-MORE EA9-T15CL-R panel?

The display screen should be cleaned periodically by wiping it with a lint-free damp cloth using a mild soap solution. Use a dry or slightly dampened cloth to wipe any dirt from the labels on the back of the panel. Dry all surfaces with a lint-free cloth. Do not clean with ammonia-based products which are solvents and will damage the face of the panel and the labels.


What should I know about using the touchscreen on the AUTOMATIONDIRECT C-MORE EA9-T15CL-R?

The touchscreen is designed to respond to a single touch. If it is touched at multiple points at the same time, an unexpected object may be activated.


What are the installation requirements when using the AUTOMATIONDIRECT C-MORE EA9-T15CL-R in a hazardous location?

For models EA9-T6CL-R and EA9-T6CL only, the following requirements apply for Class I, Division 2, Groups A, B, C hazardous locations:

• The unit is suitable for use in Class I, Division 2, Groups A, B, C and D hazardous locations, or nonhazardous locations only.

WARNING – EXPLOSION HAZARD – DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS.

WARNING – EXPLOSION HAZARD – SUBSTITUTION OF ANY COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2.

• DEVICES SHALL BE INSTALLED INTO AN ENCLOSURE THAT UTILIZES A TOOL REMOVABLE DOOR/COVER.


What are the UL satisfaction ratings for the AUTOMATIONDIRECT C-MORE EA9-T15CL-R?

Terminal connecting wire size: 12-24 AWG

Connecting torque: 71 – 85 oz-in (5 – 7 lbf-in) (0.5 – 0.6 Nm)

Surrounding Air Temperature rating: 0 to 50°C (32 to 122°F)

• For use in Pollution Degree 2 environment

• All interface ports are intended to be directly connected to an isolated secondary circuit

• For use on a flat surface of a type 4X Indoor Use Only enclosure