What are the main features of the DURASTAR DRF2TA3624ASTNJN0F air handler?
The DURASTAR DRF2TA3624ASTNJN0F air handler includes the following features and benefits:
Features:
• Constant Torque Motor (ECM)
• Two-Stage Airflow
• Thermal Expansion Valve (TXV)
• Efficiencies from 13.4 to 14.3 SEER2
Benefits:
• Front or Bottom Return with aluminum tube and fin coil
• TXV for cooling or heat pump operation
• Wall-hanging brackets
• Built in Filter Rack
• Molex Plug Connections for field installed heater kits
• Dual Voltage Direct Drive Blower with multi-speed motor
• Thermoplastic Drain Pan with bottom primary and secondary connections
• Optional Decorative Grill for front return applications
• Optional Factory Installed Condensate Float Switch which shuts off the outdoor unit in the event the condensate pan becomes clogged
• Cabinet air leakage less than 2% at 1 inch H2O when tested in accordance with ASHRAE Standard 193
• Can be field wired for single or two stage applications
What is the standard equipment included with the DURASTAR DRF2TA3624ASTNJN0F?
The standard equipment for the DURASTAR DRF2TA3624ASTNJN0F includes:
• Exclusive Incoloy sheath type electric heating elements
• Field convertible air supply
• Durable framed cleanable air filter
• Indoor coil design provides low air side pressure drop, high performance and compact size
• PVC condensate elbow is standard on all coils
• All indoor coils have aluminum tubing and aluminum fins
• Molded polymer corrosion resistant condensate drain pan
• Supply and return duct flanges
• High and low voltage connection points inside cabinet
• Concentric knockouts provided for power connection with hole size up to 2 inches [51 mm] for 1 1/2 inch [38mm] conduit
• Internal checked TX valves for quiet refrigerant metering
• Front refrigerant and drain connection
What does the model number DURASTAR DRF2TA3624ASTNJN0F signify?
The model number for the DURASTAR DRF2TA3624ASTNJN0F provides the following information:
| Part | Code | Description |
|---|---|---|
| Brand | DR | Durastar |
| Product Category | F | Front Return |
| Stages Of Airflow | 2 | 2-Stage |
| Motor Type | T | Constant Torque |
| Refrigerant | A | R-410A |
| Capacity | 36 | 36,000 [10.55 kW] |
| Width | 24 | 24.5″ |
| Major Series | A | 1st Design |
| Efficiency | S | Standard |
| Metering | T | TXV |
| Coil Series | N | N Coil |
| Voltage | J | 208-240/1/60 |
| Disconnect | N | None |
| Factory Heat | 0 | No Heat |
| Option Code | F | Float Switch |
What are the unit dimensions and weight of the DURASTAR DRF2TA3624ASTNJN0F?
The dimensions, weight, and other specifications for the DURASTAR DRF2TA3624ASTNJN0F are detailed below.
| Specification | Value (In. [mm]) |
|---|---|
| (A) Unit Width | 24 [609.6] |
| (B) Unit Height | 36 [914.4] |
| (C) Unit Depth | 21 [533.4] |
| (D) Return Air Opening Width | 23 [584.2] |
| (E) Return Air Opening Height | 21 3/8 [542.9] |
| Filter Size (in. x in. x in.) | 20 X 25 X 1 [508 X 635 X 25.4] |
| Air Flow CFM (Nom.) [L/s] – Low | 1000 [472] |
| Air Flow CFM (Nom.) [L/s] – High | 1200 [566] |
| Unit Weight/Shipping Weight (Lbs.) [kg] | 95 [43] x 105 [48] |
What are the airflow operating limits for the DURASTAR DRF2TA3624ASTNJN0F air handler?
For optimal blower performance, the DURASTAR DRF2TA3624ASTNJN0F should be operated in the .3 [8 mm] to .7 inches [18 mm] W.C. external static range. The specific operating limits for the Model Cabinet Size 24 are as follows:
| Airflow Operating Limits | Model Cabinet Size 24 |
|---|---|
| Cooling BTUH x 1,000 | -36 |
| Cooling Tons Nominal | 3 |
| Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] | 1350 [637] |
| Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] | 1200 [566] |
| Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] | 1080 [510] |
| Maximum kW Electric Heating & Minimum Electric Heat CFM [L/s] | 10 976 [461] |
| Maximum Electric Heat Rise °F [°C] | 44 [7] |
What is the airflow performance data for the DURASTAR DRF2TA3624ASTNJN0F (3 Tons model)?
The airflow performance data for the DURASTAR DRF2TA3624ASTNJN0F (3 Tons model with a 10×8 1/2 Hp blower) at various external static pressures is listed below. This data is for dry delivery and includes filter and heaters.
| Motor Speed | Metric | External Static Pressure-Inches W.C. | ||||||
|---|---|---|---|---|---|---|---|---|
| 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | ||
| 4 | CFM | 808 | 750 | 698 | 633 | 568 | 504 | 448 |
| RPM | 615 | 665 | 713 | 780 | 842 | 884 | 929 | |
| Watts | 91.4 | 97.7 | 103.9 | 112.4 | 120.2 | 125.5 | 131.2 | |
| 5 | CFM | 1241 | 1201 | 1148 | 1109 | 1065 | 1028 | 983 |
| RPM | 847 | 880 | 905 | 916 | 955 | 991 | 1035 | |
| Watts | 246.3 | 254.9 | 260.9 | 263.8 | 273.1 | 282.5 | 293.3 | |
How do the motor speed taps on the DURASTAR DRF2TA3624ASTNJN0F work?
The DURASTAR DRF2TA3624ASTNJN0F air handler has a 5-speed constant torque motor. The speed taps are used as follows:
• Speed tap 1: For continuous fan operation.
• Speed tap 2 (low static) and speed tap 3 (high static): For lower tonnage applications (1.5 or 2.5 tons).
• Speed tap 4 (low static) and speed tap 5 (high static): For higher tonnage applications (2.0 or 3.0 tons).
The unit is shipped from the factory set to speed tap 5. Use the low static speed tap (4) for external static pressures below 0.5″ WC. Use the high static speed tap (5) for external static pressures exceeding 0.5″ WC. To change the speed, move the blue wire to the appropriate speed tap on the motor terminal block as required by the application needs.
The airflow for the continuous fan (speed tap 1) is always set at 50% of the speed tap 4 airflow.
What are the electrical specifications for the blower motor of the DURASTAR DRF2TA3624ASTNJN0F without electric heat?
The electrical data for the blower motor only (no electric heat) on the DURASTAR DRF2TA3624ASTNJN0F is as follows:
| Model/Nominal Cooling Tons | DRF2TA3624 |
|---|---|
| Voltage | 208/230 |
| Phase | 1 |
| Hertz | 60 |
| HP [W] | 1/2 [373] |
| RPM | 300-1100 |
| Speeds | 4 |
| Circuit Amps. | 2.7 |
| Minimum Circuit Ampacity | 4 |
| Maximum Circuit Protector | 15 |
*Blower motors are all single phase motors.
What are the electrical specifications for the DURASTAR DRF2TA3624ASTNJN0F when using an electric heat kit?
When installing a U.L. Listed original equipment manufacturer provided heater kit with the DURASTAR DRF2TA3624ASTNJN0F, refer to the following electrical data:
| Heater Kit Model No. | Heater kW (208/240V) | PH/Hz | Circuit Amps. | Motor Ampacity | Minimum Circuit Ampacity | Maximum Circuit Protection |
|---|---|---|---|---|---|---|
| RXHJ-24B/T03J | 2.25/3.0 | 1/60 | 10.8/12.5 | 2.7 | 17/19 | 20/20 |
| RXHJ-24B/T05J | 3.6/4.8 | 1/60 | 17.3/20.0 | 2.7 | 25/29 | 25/30 |
| RXHJ-24B/T08J | 5.4/7.2 | 1/60 | 26.0/30.0 | 2.7 | 36/41 | 40/45 |
| RXHJ-24B/T10J | 7.2/9.6 | 1/60 | 34.6/40.0 | 2.7 | 47/54 | 50/60 |
What are the electrical wiring and grounding requirements for the DURASTAR DRF2TA3624ASTNJN0F?
Follow these requirements for power wiring and grounding:
• Field wiring must comply with the National Electrical Code and any applicable local ordinances.
• The product must be sufficiently grounded in accordance with all applicable codes.
• Supply wiring must be 75°C minimum copper conductors only.
• Refer to the electrical data tables for the product’s Ampacity rating and Circuit Protector requirements.
• A grounding lug is provided.
• Supply circuit protective devices may be fused or “HACR” type circuit breakers.
• If a non-standard fuse size is specified, use the next size larger standard fuse.
What accessories and kits are available for the DURASTAR DRF2TA3624ASTNJN0F air handler?
The following accessories, kits, and parts are available for the DURASTAR DRF2TA3624ASTNJN0F:
• Drain Pan Over Flow Switch RXHK-A01: This switch detects a condensate drain blockage and shuts down the outdoor unit to prevent structural damage from overflow.
• Bottom Return Conversion Kit RXHK-B02: This kit is used to divert the return air from the standard front return to a bottom return configuration.
• Louvered Cabinet Grill RXHK-C02: This is a decorative grill that covers the return air opening of the front return air handler.
• Decorative Wall Grill RXHK-D02: This grill is used in applications where the air handler is installed in a closet or interior wall, allowing adequate return air back to the unit.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD DURASTAR DRF2TA3624ASTNJN0F (01) PDF DOCUMENT