What are the key features and benefits of the DURASTAR DRF2TA2421ASTNJB5F air handler?

The DURASTAR DRF2TA2421ASTNJB5F air handler includes the following features and benefits:

• Front or Bottom Return with aluminum tube and fin coil

• TXV for cooling or heat pump operation

• Wall-hanging brackets

• Built in Filter Rack

• Molex Plug Connections for field installed heater kits

• Dual Voltage Direct Drive Blower with multi-speed motor

• Thermoplastic Drain Pan with bottom primary and secondary connections

• Optional Decorative Grill for front return applications

• Optional Factory Installed Condensate Float Switch which shuts off the outdoor unit in the event the condensate pan becomes clogged

• Cabinet air leakage less than 2% at 1 inch H2O when tested in accordance with ASHRAE Standard 193

• Can be field wired for single or two stage applications

• Exclusive Incoloy sheath type electric heating elements

• Field convertible air supply

• Durable framed cleanable air filter

• Indoor coil design provides low air side pressure drop, high performance and compact size

• PVC condensate elbow is standard on all coils

• All indoor coils have aluminum tubing and aluminum fins

• Molded polymer corrosion resistant condensate drain pan

• Supply and return duct flanges

• High and low voltage connection points inside cabinet

• Concentric knockouts provided for power connection with hole size up to 2 inches [51 mm] for 1 1/2 inch [38mm] conduit

• Internal checked TX valves for quiet refrigerant metering

• Front refrigerant and drain connection


How is the model number for the DURASTAR DRF2TA2421ASTNJB5F series decoded?

The model number for the DURASTAR DRF2TA2421ASTNJB5F series provides specific details about the unit as described in the table below:

Code DR F 2 T A 24 21 A S T N J B 0 F
Category Brand Product Category Stages Of Airflow Motor Type Refrigerant Capacity Width Major Series Efficiency Metering Coil Series Voltage Disconnect Factory Heat Option Code
Description DR – Durastar F – Front Return 2 – 2-Stage T – Constant Torque A – R-410A 24 – 24,000 [7.03 kW]
36 – 36,000 [10.55 kW]
21 – 21″
24 – 24.5″
A – 1st Design S – Standard T – TXV N – N Coil J – 208-240/1/60 B – Breaker
N – None
0 – No Heat
3 – 3 kW
5 – 5 kW
8 – 8 kW
1 – 10 kW
F – Float Switch

What are the return air opening dimensions for the different cabinet sizes of the DURASTAR DRF2TA2421ASTNJB5F series?

Return Air Opening Dimensions
Model Cabinet Size Return Air Opening Width (Inches) Return Air Opening Depth/Length (Inches)
17 15 7/8 19 3/4
21 19 3/8 19 3/4
24 22 7/8 19 3/4

What are the physical dimensions, filter size, and weights for the DURASTAR DRF2TA2421ASTNJB5F series models?

Model (A) Unit Width In. [mm] (B) Unit Height In. [mm] (C) Unit Depth In. [mm] (D) Return Air Opening Width In. [mm] (E) Return Air Opening Height In. [mm] Filter Size in. x in. x in. [mm x mm x mm] Air Flow CFM (Nom.) [L/s] Low/High Unit Weight/Shipping Weight (Lbs.) [kg]
DRF2TA2421 21 1/2 [546.1] 36 [914.4] 17 [431.8] 20 [508.0] 17 7/16 [442.9] 20 X 20 X 1 [508 X 508 X 25.4] 600 [283] / 800 [378] 95 [43] x 105 [48]
DRF2TA3624 24 [609.6] 36 [914.4] 21 [533.4] 23 [584.2] 21 3/8 [542.9] 20 X 25 X 1 [508 X 635 X 25.4] 1000 [472] / 1200 [566] 95 [43] x 105 [48]

What should I know about the airflow performance of the DURASTAR DRF2TA2421ASTNJB5F?

Airflow performance data for the DURASTAR DRF2TA2421ASTNJB5F is based on cooling performance with a coil and no filter in place. Select the performance table for the appropriate unit size, voltage, and number of electric heaters to be used. Make sure the external static pressure applied to the unit allows operation within the minimum and maximum limits shown in the “Airflow Operating Limits” table. For optimum blower performance, operate the unit in the .3 [8 mm] to .7 inches [18 mm] W.C. external static range. Units with coils should be applied with a minimum of .1 inch [3 mm] W.C. external static range.


What are the airflow operating limits for the DURASTAR DRF2TA2421ASTNJB5F series air handlers based on cabinet size?

Airflow Operating Limits
Model Cabinet Size 21 24
Cooling BTUH x 1,000 -24 -36
Cooling Tons Nominal 2 3
Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (37.5 CFM [18 L/s]/1,000 BTUH) (450 CFM [212 L/s]/Ton Nominal) 900 [425] 1350 [637]
Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (33.3 CFM [16 L/s]/1,000 BTUH) (400 CFM [189 L/s]/Ton Nominal) 800 [378] 1200 [566]
Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (30.0 CFM [14 L/s]/1,255 BTUH) (360 CFM [170 L/s]/Ton Nominal) 720 [340] 1080 [510]
Maximum kW Electric Heating & Minimum Electric Heat CFM [L/s] 10
690 [326]
10
976 [461]
Maximum Electric Heat Rise °F [°C] 44 [7] 44 [7]

What is the airflow performance data (CFM, RPM, Watts) for the DURASTAR DRF2TA2421ASTNJB5F series at various external static pressures?

115V/208V/240V Airflow Performance Data—DRF2TA (Constant Torque (ECM) Motor)
Model/Nominal Cooling Capacity Air-Flow Range (Max/Min) CFM Manufacturer Recommended Blower Size/ Motor HP # of Speeds Motor Speed From Factory Motor Speed CFM Dry Delivery/filter/heaters/RPM/Watts – External Static Pressure-Inches W.C.
0.1 0.2 0.3 0.4 0.5 0.6 0.7
DRF2TA24 1.5 Tons 825/510 10×6 1/3 Hp 2 speed dual voltage 5 2 CFM 537 495 451 404 343 286 252
RPM 608 656 702 752 826 879 935
Watts 51.2 54.5 57.6 60.9 65.9 69.5 73.2
3 CFM 735 702 666 634 600 565 528
RPM 757 794 836 872 905 942 981
Watts 99.1 103.2 107.7 112 115.6 119.6 124.1
DRF2TA24 2 Tons 973/733 10×6 1/3 Hp 2 speed dual voltage 5 4 CFM 654 616 581 542 503 463 399
RPM 694 736 777 818 858 899 971
Watts 76.4 80.1 83.7 87.6 91.3 95.1 101.6
5 CFM 887 858 830 802 771 743 717
RPM 876 914 945 976 1014 1044 1070
Watts 156 161.8 166.8 171.5 177.5 182.3 186.2
DRF2TA36 2.5 Tons 1145/894 10×8 1/2 Hp 2 speed dual voltage 5 2 CFM 772 698 635 569 497 438 366
RPM 595 639 698 771 821 866 933
Watts 82.9 84.9 91.6 100 105.8 110.7 118.3
3 CFM 1106 1053 1004 962 918 864 814
RPM 776 816 838 862 901 955 1007
Watts 183.3 191.4 195.7 200.5 208.4 219.3 230.2
DRF2TA36 3 Tons 1306/1040 10×8 1/2 Hp 2 speed dual voltage 5 4 CFM 808 750 698 633 568 504 448
RPM 615 665 713 780 842 884 929
Watts 91.4 97.7 103.9 112.4 120.2 125.5 131.2
5 CFM 1241 1201 1148 1109 1065 1028 983
RPM 847 880 905 916 955 991 1035
Watts 246.3 254.9 260.9 263.8 273.1 282.5 293.3

How do the speed tap settings work on the DURASTAR DRF2TA2421ASTNJB5F air handler?

All DURASTAR DRF2TA2421ASTNJB5F series air-handlers have 5-speed constant torque motors. The speed taps function as follows:

• Speed tap 1 is for continuous fan.

• Speed tap 2 (low static) and speed tap 3 (high static) are for lower tonnage units (1.5 or 2.5 tons).

• Speed tap 4 (low static) and speed tap 5 (high static) are for higher tonnage units (2.0 or 3.0 tons).

The DURASTAR DRF2TA2421ASTNJB5F air handlers are always shipped from the factory set to speed tap 5.

The low static speed taps (2 for lower tonnage and 4 for higher tonnage) are for external static pressures below 0.5″ WC. The high static speed taps (3 for lower tonnage and 5 for higher tonnage) are used for external static pressures exceeding 0.5″ WC. To change the speed, move the blue wire to the appropriate speed tap on the motor terminal block as required by the application.

The airflow for the continuous fan (speed tap 1) is always set at 50% of the speed tap 4.

• The airflow table lists the airflow information for air handlers with the maximum heater allowed for each model.


What are the electrical specifications for the blower motor only (no electric heat) on the DURASTAR DRF2TA2421ASTNJB5F series?

Electrical Data—Blower Motor Only—No Electric Heat
Model/Nominal Cooling Tons Voltage Phase Hertz HP [W] RPM Speeds Circuit Amps. Minimum Circuit Ampacity Maximum Circuit Protector
DRF2TA2421 208/230 1 60 1/3 [249] 300-1100 4 1.9 3 15
DRF2TA3624 208/230 1 60 1/2 [373] 300-1100 4 2.7 4 15

*Blower motors are all single phase motors.


What are the electrical specifications for the DURASTAR DRF2TA2421ASTNJB5F series when using an electric heat kit?

The following table provides the electrical data for DURASTAR DRF2TA2421ASTNJB5F models when an auxiliary electric heat kit is installed.

Electrical Data—with Electric Heat
Cooling Capacity Tons (Air Handler Model) Heater Model No. Heater kW PH/Hz No. Elements – kW Per (208/240V) Type Supply Circuit Circuit Amps. Motor Ampacity Minimum Circuit Ampacity Maximum Circuit Protection
DRF2TA3624 RXHJ-21B/T03J 2.25/3.0 1/60 1-3.0 Single 10.8/12.5 1.9 16/18 20/20
RXHJ-21B/T05J 3.6/4.8 1/60 1-4.8 Single 17.3/20.0 1.9 0.9 25/30
RXHJ-21B/T08J 5.4/7.2 1/60 2-3.6 Single 26.0/30.0 1.9 35/40 35/40
RXHJ-21B/T10J 7.2/9.6 1/60 2-4.8 Single 34.6/40.0 1.9 0.9 50/60
DRF2TA3636 RXHJ-24B/T03J 2.25/3.0 1/60 1-3.0 Single 10.8/12.5 2.7 17/19 20/20
RXHJ-24B/T05J 3.6/4.8 1/60 1-4.8 Single 17.3/20.0 2.7 25/29 25/30
RXHJ-24B/T08J 5.4/7.2 1/60 2-3.6 Single 26.0/30.0 2.7 36/41 40/45
RXHJ-24B/T10J 7.2/9.6 1/60 2-4.8 Single 34.6/40.0 2.7 47/54 50/60

• Electric heater BTUH = (heater watts + motor watts) x 3.414 (see airflow table for motor watts.)

• J voltage (230V) single phase air handler is designed to be used with single or three phase.

• Supply circuit protective devices may be fused or “HACR” type circuit breakers.

• If non-standard fuse size is specified, use next size larger standard fuse size. Without the heater, bring only two leads to terminal block, cap, insulate and fully secure the third lead.

• Largest motor load is included in single circuit or circuit 1 of multiple circuits.

• Do not use 480 volts electrical heaters on 230 volts air handler.


What are the electrical wiring and grounding requirements for installing the DURASTAR DRF2TA2421ASTNJB5F?

When installing the DURASTAR DRF2TA2421ASTNJB5F, follow these power wiring and grounding requirements:

• Field wiring must comply with the National Electrical Code.

• This product must be sufficiently grounded in accordance with (C.E.C. in Canada) and any applicable local ordinance. National Electrical Code (C.E.C. in Canada) and any applicable local ordinance.

• Supply wiring must be 75°C minimum copper conductors only.

• See electrical data for product Ampacity rating and Circuit Protector requirement.

• A grounding lug is provided.


What optional accessories, kits, and parts are available for the DURASTAR DRF2TA2421ASTNJB5F?

The following accessories, kits, and parts are available for the DURASTAR DRF2TA2421ASTNJB5F air handler:

Drain Pan Over Flow Switch RXHK-A01: This switch is used to detect condensate drain blockage. It will shut down the outdoor unit to prevent structural damage to the surrounding structures of the air handler.

Bottom Return Conversion Kit (RXHK-B01 or RXHK-B02): This kit is used to divert the return air from the factory standard front return to a bottom return configuration.

Louvered Cabinet Grill (RXHK-C01 or RXHK-C02): This serves as a decorative grill that covers the return air opening of the front return air handler.

Decorative Wall Grill (RXHK-D01 or RXHK-D02): This grill is used in applications where the air handler is installed in a closet or interior wall. It allows for adequate return air to flow back to the unit.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD DURASTAR DRF2TA2421ASTNJB5F (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.