DURASTAR DRF2TA2421ASTNJB5 (01) Image

Free English DURASTAR DRF2TA2421ASTNJB5 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD DURASTAR DRF2TA2421ASTNJB5 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

What are the key features and benefits of the DURASTAR DRF2TA2421ASTNJB5 air handler?

The DURASTAR DRF2TA2421ASTNJB5 air handler includes the following features and benefits:

• Front or Bottom Return with aluminum tube and fin coil

• TXV for cooling or heat pump operation

• Wall-hanging brackets

• Built in Filter Rack

• Molex Plug Connections for field installed heater kits

• Dual Voltage Direct Drive Blower with multi-speed motor

• Thermoplastic Drain Pan with bottom primary and secondary connections

• Optional Decorative Grill for front return applications

• Optional Factory Installed Condensate Float Switch which shuts off the outdoor unit in the event the condensate pan becomes clogged

• Cabinet air leakage less than 2% at 1 inch H2O when tested in accordance with ASHRAE Standard 193

• Can be field wired for single or two stage applications


What standard equipment is included with the DURASTAR DRF2TA2421ASTNJB5 air handler?

Standard equipment for the DURASTAR DRF2TA2421ASTNJB5 includes:

• Exclusive Incoloy sheath type electric heating elements

• Field convertible air supply

• Durable framed cleanable air filter

• Indoor coil design provides low air side pressure drop, high performance and compact size

• PVC condensate elbow is standard on all coils

• All indoor coils have aluminum tubing and aluminum fins

• Molded polymer corrosion resistant condensate drain pan

• Supply and return duct flanges

• High and low voltage connection points inside cabinet

• Concentric knockouts provided for power connection with hole size up to 2 inches [51 mm] for 1 1/2 inch [38mm] conduit

• Internal checked TX valves for quiet refrigerant metering

• Front refrigerant and drain connection


How do I interpret the model number for the DURASTAR DRF2TA series air handlers?

The model number provides specific details about the unit. Here is a breakdown:

Position Code Description
Brand DR Durastar
Product Category F Front Return
Stages of Airflow 2 2-Stage
Motor Type T Constant Torque
Refrigerant A R-410A
Capacity 24
36
24,000 [7.03 kW]
36,000 [10.55 kW]
Width 21
24
21″
24.5″
Major Series A 1st Design
Efficiency S Standard
Metering T TXV
Coil Series N N Coil
Voltage J 208-240/1/60
Disconnect B
N
Breaker
None
Factory Heat 0
3
5
8
1
No Heat
3 kW
5 kW
8 kW
10 kW
Option Code F Float Switch

What are the return air opening dimensions for the DURASTAR DRF2TA2421ASTNJB5 air handler?

Model Cabinet Size Return Air Opening Width (Inches) Return Air Opening Depth/Length (Inches)
17 15 7/8 19 3/4
21 19 3/8 19 3/4
24 22 7/8 19 3/4

What are the unit dimensions, weight, filter size, and nominal airflow for the DURASTAR DRF2TA2421ASTNJB5?

The specifications for the DURASTAR DRF2TA2421ASTNJB5 (model DRF2TA2421) are as follows:

(A) Unit Width In. [mm] (B) Unit Height In. [mm] (C) Unit Depth In. [mm] (D) Return Air Opening Width In. [mm] (E) Return Air Opening Height In. [mm] Filter Size in. x in. x in. [mm x mm x mm] Air Flow CFM (Nom.) [L/s] Low Air Flow CFM (Nom.) [L/s] High Unit Weight/Shipping Weight (Lbs.) [kg]
21 1/2 [546.1] 36 [914.4] 17 [431.8] 20 [508.0] 17 7/16 [442.9] 20 X 20 X 1 [508 X 508 X 25.4] 600 [283] 800 [378] 95 [43] / 105 [48]

What are the airflow operating limits for the DURASTAR DRF2TA2421ASTNJB5 air handler?

Airflow performance data is based on cooling performance with a coil and no filter in place. For optimum blower performance, operate the unit in the .3 [8 mm] to .7 inches [18 mm] W.C. external static range. Units with coils should be applied with a minimum of .1 inch [3 mm] W.C. external static range.

Airflow Operating Limits
Model Cabinet Size 21
Cooling BTUH x 1,000 -24
Cooling Tons Nominal 2
Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (37.5 CFM [18 L/s]/1,000 BTUH) (450 CFM [212 L/s]/Ton Nominal) 900 [425]
Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (33.3 CFM [16 L/s]/1,000 BTUH) (400 CFM [189 L/s]/Ton Nominal) 800 [378]
Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (30.0 CFM [14 L/s]/1,255 BTUH) (360 CFM [170 L/s]/Ton Nominal) 720 [340]
Maximum kW Electric Heating & Minimum Electric Heat CFM [L/s] 10
690 [326]
Maximum Electric Heat Rise °F [°C] 44 [7]

What is the airflow performance data for the DURASTAR DRF2TA2421ASTNJB5 air handler?

The following table provides the airflow performance data for the 2 Ton model (DRF2TA24) with a 10×6 1/3 Hp, 2-speed dual voltage motor, based on various motor speeds and external static pressures.

115V/208V/240V Airflow Performance Data—DRF2TA (Constant Torque (ECM) Motor)
Model/Nominal Cooling Capacity Air-Flow Range (Max/Min) CFM Manufacturer Recommended Blower Size/ Motor HP # of Speeds Motor Speed From Factory Motor Speed CFM Dry Delivery/filter/heaters/RPM/Watts
External Static Pressure-Inches W.C.
0.1 0.2 0.3 0.4 0.5 0.6 0.7
DRF2TA24
2 Tons
973/733 10×6 1/3 Hp
2 speed
dual voltage
5 4 CFM 654 616 581 542 503 463 399
RPM 694 736 777 818 858 899 971
Watts 76.4 80.1 83.7 87.6 91.3 95.1 101.6
5 CFM 887 858 830 802 771 743 717
RPM 876 914 945 976 1014 1044 1070
Watts 156 161.8 166.8 171.5 177.5 182.3 186.2

NOTE:

• All DRF2TA air-handlers have 5 speed constant torque motors.

• Speed tap 1 is for continuous fan. Speed tap 2 (low static) and speed tap 3 (high static) are for lower tonnage (1.5 or 2.5 tons). Speed tap 4 (low static) and speed tap 5 (high static) are for higher tonnage (2.0 or 3.0 tons).

• DRF2TA air handlers are always shipped from factory at speed tap 5.

• The low static speed tap 2 (lower tonnage) and 4 (higher tonnage) are for external static pressures below 0.5″ WC. The high static speed tap 3 (lower tonnage) and 5 (higher tonnage) are used for external static exceeding 0.5″ WC. Move the blue wire to the appropriate speed tap on the motor terminal block as required by the application needs.

• The airflow for continuous fan (speed tap 1) is always set at 50% of the speed tap 4.

• The above airflow table lists the airflow information for air handlers with maximum heater allowed for each model.


What are the electrical specifications for the blower motor only on the DURASTAR DRF2TA2421ASTNJB5?

The electrical specifications for the blower motor without electric heat for model DRF2TA2421 are:

Voltage Phase Hertz HP [W] RPM Speeds Circuit Amps. Minimum Circuit Ampacity Maximum Circuit Protector
208/230 1 60 1/3 [249] 300-1100 4 1.9 3 15

*Blower motors are all single phase motors.


What are the electrical specifications for the DURASTAR DRF2TA2421ASTNJB5 when used with an electric heat kit?

Installation of U.L. Listed original equipment manufacturer provided heater kits is recommended. Below are the electrical specifications for the DRF2TA2421 (compatible with heater kits starting with RXHJ-21B) with various electric heat kits.

Cooling Capacity Tons Model No. Heater kW PH/Hz No. Elements – kW Per (208/240V) Type Supply Circuit Circuit Amps. Motor Ampacity Minimum Circuit Ampacity Maximum Circuit Protection
DRF2TA3624 RXHJ-21B/T03J 2.25/3.0 1/60 1-3.0 Single 10.8/12.5 1.9 16/18 20/20
RXHJ-21B/T05J 3.6/4.8 1/60 1-4.8 Single 17.3/20.0 1.9 0.9 25/30
RXHJ-21B/T08J 5.4/7.2 1/60 2-3.6 Single 26.0/30.0 1.9 35/40 35/40
RXHJ-21B/T10J 7.2/9.6 1/60 2-4.8 Single 34.6/40.0 1.9 0.9 50/60

What are the power wiring and grounding requirements for the DURASTAR DRF2TA2421ASTNJB5?

Please adhere to the following electrical wiring requirements:

• Field wiring must comply with the National Electrical Code (C.E.C. in Canada) and any applicable local ordinance.

• This product must be sufficiently grounded in accordance with the National Electrical Code (C.E.C. in Canada) and any applicable local ordinance.

• Supply wiring must be 75°C minimum copper conductors only.

• Refer to the electrical data for the product Ampacity rating and Circuit Protector requirement.

• A grounding lug is provided.

Additional notes:

• Electric heater BTUH = (heater watts + motor watts) x 3.414.

• J voltage (230V) single phase air handler is designed to be used with single or three phase.

• Supply circuit protective devices may be fused or “HACR” type circuit breakers.

• If a non-standard fuse size is specified, use the next size larger standard fuse size. Without the heater, bring only two leads to terminal block, cap, insulate and fully secure the third lead.

• Largest motor load is included in single circuit or circuit 1 of multiple circuits.

• Do not use 480 volts electrical heaters on 230 volts air handler.


What optional accessories, kits, and parts are available for the DURASTAR DRF2TA2421ASTNJB5?

The following accessories and kits are available for the DURASTAR DRF2TA2421ASTNJB5:

Drain Pan Over Flow Switch RXHK-A01: This switch detects condensate drain blockage and shuts down the outdoor unit to prevent structural damage.

Bottom Return Conversion Kit RXHK-B01: This kit is used to divert the return air from the standard front return to a bottom return.

Accessory Number Indoor Unit
RXHK-B01 DRF2TA-FR18
DRF2TA-FR24
RF1T-FR24

Louvered Cabinet Grill RXHK-C01: This is a decorative grill that covers the return air opening of the front return air handler.

Accessory Number Indoor Unit
RXHK-C01 DRF2TA-FR18
DRF2TA-FR24
RF1T-FR24

Decorative Wall Grill RXHK-D01: This grill is used in applications where the air handler is installed in a closet or interior wall, allowing for adequate return air back to the unit. Refer to the installation instructions for complete dimensional information.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD DURASTAR DRF2TA2421ASTNJB5 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.