What are the features and benefits of the DURASTAR DRF2TA2421ASTNJB3F air handler?
The features and benefits of the DURASTAR DRF2TA2421ASTNJB3F air handler include:
• Front or Bottom Return with aluminum tube and fin coil
• TXV for cooling or heat pump operation
• Wall-hanging brackets
• Built in Filter Rack
• Molex Plug Connections for field installed heater kits
• Dual Voltage Direct Drive Blower with multi-speed motor
• Thermoplastic Drain Pan with bottom primary and secondary connections
• Optional Decorative Grill for front return applications
• Optional Factory Installed Condensate Float Switch which shuts off the outdoor unit in the event the condensate pan becomes clogged
• Cabinet air leakage less than 2% at 1 inch H2O when tested in accordance with ASHRAE Standard 193
• Can be field wired for single or two stage applications
How can the model number of the DURASTAR DRF2TA2421ASTNJB3F series be identified?
The model number is broken down as follows:
| Code | Category | Meaning |
|---|---|---|
| DR | Brand | DR – Durastar |
| F | Product Category | F – Front Return |
| 2 | Stages Of Airflow | 2 – 2-Stage |
| T | Motor Type | T – Constant Torque |
| A | Refrigerant | A – R-410A |
| 24, 36 | Capacity | 24 – 24,000 [7.03 kW], 36 – 36,000 [10.55 kW] |
| 21, 24 | Width | 21 – 21″, 24 – 24.5″ |
| A | Major Series | A – 1st Design |
| S | Efficiency | S – Standard |
| T | Metering | T – TXV |
| N | Coil Series | N – N Coil |
| J | Voltage | J – 208-240/1/60 |
| B, N | Disconnect | B – Breaker, N – None |
| 0, 3, 5, 8, 1 | Factory Heat | 0 – No Heat, 3 – 3 kW, 5 – 5 kW, 8 – 8 kW, 1 – 10 kW |
| F | Option Code | F – Float Switch |
What standard equipment comes with the DURASTAR DRF2TA2421ASTNJB3F air handler?
The standard equipment includes:
• Exclusive Incoloy sheath type electric heating elements
• Field convertible air supply
• Durable framed cleanable air filter
• Indoor coil design provides low air side pressure drop, high performance and compact size
• PVC condensate elbow is standard on all coils
• All indoor coils have aluminum tubing and aluminum fins
• Molded polymer corrosion resistant condensate drain pan
• Supply and return duct flanges
• High and low voltage connection points inside cabinet
• Concentric knockouts provided for power connection with hole size up to 2 inches [51 mm] for 1 1/2 inch [38mm] conduit
• Internal checked TX valves for quiet refrigerant metering
• Front refrigerant and drain connection
What are the unit dimensions and weights for the DURASTAR DRF2TA2421ASTNJB3F series models?
| Model | (A) Unit Width In. [mm] | (B) Unit Height In. [mm] | (C) Unit Depth In. [mm] | (D) Return Air Opening Width In. [mm] | (E) Return Air Opening Height In. [mm] | Filter Size in. x in. x in. [mm x mm x mm] | Air Flow CFM (Nom.) [L/s] | Unit Weight/Shipping Weight (Lbs.) [kg] | |
|---|---|---|---|---|---|---|---|---|---|
| Low | High | ||||||||
| DRF2TA2421 | 21 1/2 [546.1] | 36 [914.4] | 17 [431.8] | 20 [508.0] | 17 7/16 [442.9] | 20 X 20 X 1 [508 X 508 X 25.4] | 600 [283] | 800 [378] | 95 [43] x 105 [48] |
| DRF2TA3624 | 24 [609.6] | 36 [914.4] | 21 [533.4] | 23 [584.2] | 21 3/8 [542.9] | 20 X 25 X 1 [508 X 635 X 25.4] | 1000 [472] | 1200 [566] | 95 [43] x 105 [48] |
What are the airflow operating limits for the DURASTAR DRF2TA2421ASTNJB3F series models?
Airflow performance data is based on cooling performance with a coil and no filter in place. For optimum blower performance, operate the unit in the .3 [8 mm] to .7 inches [18 mm] W.C. external static range. Units with coils should be applied with a minimum of .1 inch [3 mm] W.C. external static range.
| Model Cabinet Size | 21 | 24 |
|---|---|---|
| Cooling BTUH x 1,000 | -24 | -36 |
| Cooling Tons Nominal | 2 | 3 |
| Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (37.5 CFM [18 L/s]/1,000 BTUH) (450 CFM [212 L/s]/Ton Nominal) | 900 [425] | 1350 [637] |
| Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (33.3 CFM [16 L/s]/1,000 BTUH) (400 CFM [189 L/s]/Ton Nominal) | 800 [378] | 1200 [566] |
| Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (30.0 CFM [14 L/s]/1,255 BTUH) (360 CFM [170 L/s]/Ton Nominal) | 720 [340] | 1080 [510] |
| Maximum kW Electric Heating & Minimum Electric Heat CFM [L/s] | 10 690 [326] |
10 976 [461] |
| Maximum Electric Heat Rise °F [°C] | 44 [7] | 44 [7] |
What is the airflow performance data for the DURASTAR DRF2TA2421ASTNJB3F series?
The following table provides the 115V/208V/240V Airflow Performance Data for the DRF2TA series with a Constant Torque (ECM) Motor.
| Model/Nominal Cooling Capacity | Air-Flow Range (Max/Min) CFM | Manufacturer Recommended Blower Size/Motor HP # of Speeds | Motor Speed From Factory | Motor Speed | CFM Dry Delivery/filter/heaters/RPM/Watts External Static Pressure-Inches W.C. | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | ||||||
| DRF2TA24 1.5 Tons | 825/510 | 10×6 1/3 Hp 2 speed dual voltage | 5 | 2 | CFM | 537 | 495 | 451 | 404 | 343 | 286 | 252 |
| RPM | 608 | 656 | 702 | 752 | 826 | 879 | 935 | |||||
| Watts | 51.2 | 54.5 | 57.6 | 60.9 | 65.9 | 69.5 | 73.2 | |||||
| 3 | CFM | 735 | 702 | 666 | 634 | 600 | 565 | 528 | ||||
| RPM | 757 | 794 | 836 | 872 | 905 | 942 | 981 | |||||
| Watts | 99.1 | 103.2 | 107.7 | 112 | 115.6 | 119.6 | 124.1 | |||||
| DRF2TA24 2 Tons | 973/733 | 10×6 1/3 Hp 2 speed dual voltage | 5 | 4 | CFM | 654 | 616 | 581 | 542 | 503 | 463 | 399 |
| RPM | 694 | 736 | 777 | 818 | 858 | 899 | 971 | |||||
| Watts | 76.4 | 80.1 | 83.7 | 87.6 | 91.3 | 95.1 | 101.6 | |||||
| 5 | CFM | 887 | 858 | 830 | 802 | 771 | 743 | 717 | ||||
| RPM | 876 | 914 | 945 | 976 | 1014 | 1044 | 1070 | |||||
| Watts | 156 | 161.8 | 166.8 | 171.5 | 177.5 | 182.3 | 186.2 | |||||
| DRF2TA36 2.5 Tons | 1145/894 | 10×8 1/2 Hp 2 speed dual voltage | 5 | 2 | CFM | 772 | 698 | 635 | 569 | 497 | 438 | 366 |
| RPM | 595 | 639 | 698 | 771 | 821 | 866 | 933 | |||||
| Watts | 82.9 | 84.9 | 91.6 | 100 | 105.8 | 110.7 | 118.3 | |||||
| 3 | CFM | 1106 | 1053 | 1004 | 962 | 918 | 864 | 814 | ||||
| RPM | 776 | 816 | 838 | 862 | 901 | 955 | 1007 | |||||
| Watts | 183.3 | 191.4 | 195.7 | 200.5 | 208.4 | 219.3 | 230.2 | |||||
| DRF2TA36 3 Tons | 1306/1040 | 10×8 1/2 Hp 2 speed dual voltage | 5 | 4 | CFM | 808 | 750 | 698 | 633 | 568 | 504 | 448 |
| RPM | 615 | 665 | 713 | 780 | 842 | 884 | 929 | |||||
| Watts | 91.4 | 97.7 | 103.9 | 112.4 | 120.2 | 125.5 | 131.2 | |||||
| 5 | CFM | 1241 | 1201 | 1148 | 1109 | 1065 | 1028 | 983 | ||||
| RPM | 847 | 880 | 905 | 916 | 955 | 991 | 1035 | |||||
| Watts | 246.3 | 254.9 | 260.9 | 263.8 | 273.1 | 282.5 | 293.3 | |||||
How do the motor speed taps on the DURASTAR DRF2TA2421ASTNJB3F air handler operate?
All DRF2TA air handlers have 5-speed constant torque motors. The speed taps are used as follows:
• Speed tap 1 is for continuous fan.
• Speed tap 2 (low static) and speed tap 3 (high static) are for lower tonnage (1.5 or 2.5 tons).
• Speed tap 4 (low static) and speed tap 5 (high static) are for higher tonnage (2.0 or 3.0 tons).
• The air handlers are always shipped from the factory at speed tap 5.
The low static speed taps (2 and 4) are for external static pressures below 0.5″ WC. The high static speed taps (3 and 5) are used for external static exceeding 0.5″ WC. To change the speed, move the blue wire to the appropriate speed tap on the motor terminal block as required by the application.
The airflow for the continuous fan (speed tap 1) is always set at 50% of the speed tap 4.
What are the electrical specifications for the blower motor only on the DURASTAR DRF2TA2421ASTNJB3F series?
The following table outlines the electrical data for the blower motor without electric heat. Blower motors are all single phase motors.
| Model/Nominal Cooling Tons | Voltage | Phase | Hertz | HP [W] | RPM | Speeds | Circuit Amps. | Minimum Circuit Ampacity | Maximum Circuit Protector |
|---|---|---|---|---|---|---|---|---|---|
| DRF2TA2421 | 208/230 | 1 | 60 | 1/3 [249] | 300-1100 | 4 | 1.9 | 3 | 15 |
| DRF2TA3624 | 208/230 | 1 | 60 | 1/2 [373] | 300-1100 | 4 | 2.7 | 4 | 15 |
What are the electrical specifications for the DURASTAR DRF2TA2421ASTNJB3F series with an electric heat kit installed?
Installation of a U.L. Listed original equipment manufacturer provided heater kit is recommended for all auxiliary heating requirements. The electrical data is as follows:
| Cooling Capacity Tons | Model No. | Heater kW | PH/Hz | No. Elements – kW Per | (208/240V) Type Supply Circuit | Circuit Amps. | Motor Ampacity | Minimum Circuit Ampacity | Maximum Circuit Protection |
|---|---|---|---|---|---|---|---|---|---|
| DRF2TA3624 | RXHJ-21B/T03J | 2.25/3.0 | 1/60 | 1-3.0 | Single | 10.8/12.5 | 1.9 | 16/18 | 20/20 |
| RXHJ-21B/T05J | 3.6/4.8 | 1/60 | 1-4.8 | Single | 17.3/20.0 | 1.9 | 0.9 | 25/30 | |
| RXHJ-21B/T08J | 5.4/7.2 | 1/60 | 2-3.6 | Single | 26.0/30.0 | 1.9 | 35/40 | 35/40 | |
| RXHJ-21B/T10J | 7.2/9.6 | 1/60 | 2-4.8 | Single | 34.6/40.0 | 1.9 | 0.9 | 50/60 | |
| DRF2TA3636 | RXHJ-24B/T03J | 2.25/3.0 | 1/60 | 1-3.0 | Single | 10.8/12.5 | 2.7 | 17/19 | 20/20 |
| RXHJ-24B/T05J | 3.6/4.8 | 1/60 | 1-4.8 | Single | 17.3/20.0 | 2.7 | 25/29 | 25/30 | |
| RXHJ-24B/T08J | 5.4/7.2 | 1/60 | 2-3.6 | Single | 26.0/30.0 | 2.7 | 36/41 | 40/45 | |
| RXHJ-24B/T10J | 7.2/9.6 | 1/60 | 2-4.8 | Single | 34.6/40.0 | 2.7 | 47/54 | 50/60 |
What are the electrical wiring and grounding guidelines for the DURASTAR DRF2TA2421ASTNJB3F air handler?
• Field wiring must comply with the National Electrical Code and any applicable local ordinance.
• This product must be sufficiently grounded in accordance with the National Electrical Code (C.E.C. in Canada) and any applicable local ordinance.
• Supply wiring must be 75°C minimum copper conductors only.
• See electrical data for product Ampacity rating and Circuit Protector requirement.
• A grounding lug is provided.
• J voltage (230V) single phase air handler is designed to be used with single or three phase.
• Supply circuit protective devices may be fused or “HACR” type circuit breakers.
• If non-standard fuse size is specified, use next size larger standard fuse size. Without the heater, bring only two leads to terminal block, cap, insulate and fully secure the third lead.
• Largest motor load is included in single circuit or circuit 1 of multiple circuits.
• Do not use 480 volts electrical heaters on 230 volts air handler.
What accessories and kits are available for the DURASTAR DRF2TA2421ASTNJB3F series air handler?
Drain Pan Over Flow Switch RXHK-A01: This is used to detect condensate drain blockage and will shut down the outdoor unit to prevent structural damage to the surrounding structures of the air handler.
Bottom Return Conversion Kit RXHK: This kit is used to divert the return air from the factory standard front return to a bottom return.
| Accessory Number | Indoor Unit |
|---|---|
| RXHK-B01 | DRF2TA-FR18 |
| DRF2TA-FR24 | |
| RF1T-FR24 | |
| RXHK-B02 | DRF2TA-FR30 |
| DRF2TA-FR36 | |
| RF1T-FR36 |
Louvered Cabinet Grill RXHK: This is used as a decorative grill which covers the return air opening of the front return air handler.
| Accessory Number | Indoor Unit |
|---|---|
| RXHK-C01 | DRF2TA-FR18 |
| DRF2TA-FR24 | |
| RF1T-FR24 | |
| RXHK-C02 | DRF2TA-FR30 |
| DRF2TA-FR36 | |
| RF1T-FR36 |
Decorative Wall Grill RXHK-D01 or RXHK-D02: This is used in applications where the air handler is installed in a closet or interior wall and allows adequate return air back to the unit.