What are the key features and benefits of the DURASTAR DRF2TA3624ASTNJB1F air handler?
The DURASTAR DRF2TA3624ASTNJB1F air handler includes the following features and benefits:
Features:
• Front or Bottom Return with aluminum tube and fin coil
• TXV for cooling or heat pump operation
• Wall-hanging brackets
• Built in Filter Rack
• Molex Plug Connections for field installed heater kits
• Dual Voltage Direct Drive Blower with multi-speed motor
• Thermoplastic Drain Pan with bottom primary and secondary connections
Benefits:
• Optional Decorative Grill for front return applications
• Optional Factory Installed Condensate Float Switch which shuts off the outdoor unit in the event the condensate pan becomes clogged
• Cabinet air leakage less than 2% at 1 inch H2O when tested in accordance with ASHRAE Standard 193
• Can be field wired for single or two stage applications
What is the standard equipment included with the DURASTAR DRF2TA3624ASTNJB1F?
The standard equipment for the DURASTAR DRF2TA3624ASTNJB1F includes:
• Exclusive Incoloy sheath type electric heating elements
• Field convertible air supply
• Durable framed cleanable air filter
• Indoor coil design provides low air side pressure drop, high performance and compact size
• PVC condensate elbow is standard on all coils
• All indoor coils have aluminum tubing and aluminum fins
• Molded polymer corrosion resistant condensate drain pan
• Supply and return duct flanges
• High and low voltage connection points inside cabinet
• Concentric knockouts provided for power connection with hole size up to 2 inches [51 mm] for 1 1/2 inch [38mm] conduit
• Internal checked TX valves for quiet refrigerant metering
• Front refrigerant and drain connection
What are the dimensions and weight of the DURASTAR DRF2TA3624ASTNJB1F air handler?
The dimensions, weights, and filter size for the DURASTAR DRF2TA3624ASTNJB1F are detailed in the table below.
| Model | (A) Unit Width In. [mm] | (B) Unit Height In. [mm] | (C) Unit Depth In. [mm] | (D) Return Air Opening Width In. [mm] | (E) Return Air Opening Height In. [mm] | Filter Size in. x in. x in. [mm x mm x mm] | Unit Weight/Shipping Weight (Lbs.) [kg] |
|---|---|---|---|---|---|---|---|
| DRF2TA3624 | 24 [609.6] | 36 [914.4] | 21 [533.4] | 23 [584.2] | 21 3/8 [542.9] | 20 X 25 X 1 [508 X 635 X 25.4] | 95 [43] x 105 [48] |
What are the airflow operating limits for the DURASTAR DRF2TA3624ASTNJB1F?
For optimal blower performance, the DURASTAR DRF2TA3624ASTNJB1F should be operated in the .3 [8 mm] to .7 inches [18 mm] W.C. external static range. Units with coils should be applied with a minimum of .1 inch [3 mm] W.C. external static range. The specific operating limits are as follows:
| Model Cabinet Size | 24 |
|---|---|
| Cooling BTUH x 1,000 | -36 |
| Cooling Tons Nominal | 3 |
| Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (37.5 CFM [18 L/s]/1,000 BTUH) (450 CFM [212 L/s]/Ton Nominal) |
1350 [637] |
| Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (33.3 CFM [16 L/s]/1,000 BTUH) (400 CFM [189 L/s]/Ton Nominal) |
1200 [566] |
| Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (30.0 CFM [14 L/s]/1,255 BTUH) (360 CFM [170 L/s]/Ton Nominal) |
1080 [510] |
| Maximum kW Electric Heating & Minimum Electric Heat CFM [L/s] |
10 976 [461] |
| Maximum Electric Heat Rise °F [°C] | 44 [7] |
What is the airflow performance data for the DURASTAR DRF2TA3624ASTNJB1F air handler?
The airflow performance data for the DURASTAR DRF2TA3624ASTNJB1F (3 Tons model) with a 10×8 1/2 Hp, 2-speed dual voltage motor is provided below, showing CFM, RPM, and Watts at various external static pressures.
| Motor Speed From Factory | Motor Speed | External Static Pressure-Inches W.C. | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | |||
| 5 | 2 | CFM | 772 | 698 | 635 | 569 | 497 | 438 | 366 |
| RPM | 595 | 639 | 698 | 771 | 821 | 866 | 933 | ||
| Watts | 82.9 | 84.9 | 91.6 | 100 | 105.8 | 110.7 | 118.3 | ||
| 3 | CFM | 1106 | 1053 | 1004 | 962 | 918 | 864 | 814 | |
| RPM | 776 | 816 | 838 | 862 | 901 | 955 | 1007 | ||
| Watts | 183.3 | 191.4 | 195.7 | 200.5 | 208.4 | 219.3 | 230.2 | ||
| 4 | CFM | 808 | 750 | 698 | 633 | 568 | 504 | 448 | |
| RPM | 615 | 665 | 713 | 780 | 842 | 884 | 929 | ||
| Watts | 91.4 | 97.7 | 103.9 | 112.4 | 120.2 | 125.5 | 131.2 | ||
| 5 | CFM | 1241 | 1201 | 1148 | 1109 | 1065 | 1028 | 983 | |
| RPM | 847 | 880 | 905 | 916 | 955 | 991 | 1035 | ||
| Watts | 246.3 | 254.9 | 260.9 | 263.8 | 273.1 | 282.5 | 293.3 | ||
How are the 5-speed constant torque motor speeds configured and adjusted on the DURASTAR DRF2TA3624ASTNJB1F?
The DURASTAR DRF2TA3624ASTNJB1F has a 5-speed constant torque motor. The unit is shipped from the factory set at speed tap 5.
• Speed tap 1 is for continuous fan.
• Speed tap 2 (low static) and speed tap 3 (high static) are for lower tonnage models (1.5 or 2.5 tons).
• Speed tap 4 (low static) and speed tap 5 (high static) are for higher tonnage models, such as the 3.0 ton DURASTAR DRF2TA3624ASTNJB1F.
The low static speed tap 4 is for external static pressures below 0.5″ WC. The high static speed tap 5 is used for external static exceeding 0.5″ WC. To adjust the speed, move the blue wire to the appropriate speed tap on the motor terminal block as required by the application.
The airflow for the continuous fan (speed tap 1) is always set at 50% of the speed tap 4 airflow.
What are the electrical specifications for the blower motor of the DURASTAR DRF2TA3624ASTNJB1F without electric heat?
| Model/Nominal Cooling Tons | Voltage | Phase | Hertz | HP [W] | RPM | Speeds | Circuit Amps. | Minimum Circuit Ampacity | Maximum Circuit Protector |
|---|---|---|---|---|---|---|---|---|---|
| DRF2TA3624 | 208/230 | 1 | 60 | 1/2 [373] | 300-1100 | 4 | 2.7 | 4 | 15 |
*Blower motors are all single phase motors.
What are the electrical specifications for the DURASTAR DRF2TA3624ASTNJB1F when used with an electric heat kit?
The following table provides the electrical data for the DURASTAR DRF2TA3624ASTNJB1F when used with compatible U.L. Listed original equipment manufacturer provided heater kits.
| Cooling Capacity Tons | Model No. | Heater kW | PH/Hz | No. Elements – kW Per | (208/240V) Type Supply Circuit | Circuit Amps. | Motor Ampacity | Minimum Circuit Ampacity | Maximum Circuit Protection |
|---|---|---|---|---|---|---|---|---|---|
| DRF2TA3636 | RXHJ-24B/T03J | 2.25/3.0 | 1/60 | 1-3.0 | Single | 10.8/12.5 | 2.7 | 17/19 | 20/20 |
| RXHJ-24B/T05J | 3.6/4.8 | 1/60 | 1-4.8 | Single | 17.3/20.0 | 2.7 | 25/29 | 25/30 | |
| RXHJ-24B/T08J | 5.4/7.2 | 1/60 | 2-3.6 | Single | 26.0/30.0 | 2.7 | 36/41 | 40/45 | |
| RXHJ-24B/T10J | 7.2/9.6 | 1/60 | 2-4.8 | Single | 34.6/40.0 | 2.7 | 47/54 | 50/60 |
Notes:
• Electric heater BTUH = (heater watts + motor watts) x 3.414.
• J voltage (230V) single phase air handler is designed to be used with single or three phase.
• Supply circuit protective devices may be fused or “HACR” type circuit breakers.
• If non-standard fuse size is specified, use next size larger standard fuse size. Without the heater, bring only two leads to terminal block, cap, insulate and fully secure the third lead.
• Largest motor load is included in single circuit or circuit 1 of multiple circuits.
• Do not use 480 volts electrical heaters on 230 volts air handler.
What are the requirements for electrical and power wiring for the DURASTAR DRF2TA3624ASTNJB1F?
Electrical Wiring: Power Wiring Grounding
• Field wiring must comply with the National Electrical Code.
• This product must be sufficiently grounded in accordance with (C.E.C. in Canada) and any applicable local ordinance.
• Supply wiring must be 75°C minimum copper conductors only, in accordance with the National Electrical Code (C.E.C. in Canada) and any applicable local ordinance.
• See electrical data for product Ampacity rating and Circuit Protector requirement.
• A grounding lug is provided.
What optional accessories and kits are available for the DURASTAR DRF2TA3624ASTNJB1F air handler?
Several accessories are available for the DURASTAR DRF2TA3624ASTNJB1F:
• Drain Pan Over Flow Switch (RXHK-A01): This switch detects a condensate drain blockage and shuts down the outdoor unit to prevent structural damage.
• Bottom Return Conversion Kit (RXHK-B02): This kit is used to divert the return air from the standard front return to a bottom return configuration. It is compatible with indoor unit model DRF2TA-FR36.
• Louvered Cabinet Grill (RXHK-C02): This is a decorative grill that covers the return air opening of the front return air handler. It is compatible with indoor unit model DRF2TA-FR36.
• Decorative Wall Grill (RXHK-D01 or RXHK-D02): This grill is used when the air handler is installed in a closet or interior wall to allow adequate return air back to the unit.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD DURASTAR DRF2TA3624ASTNJB1F (01) PDF DOCUMENT