SPEED QUEEN SCB30XG (01) Image

FREE ENGLISH SPEED QUEEN SCB30XG (01) PDF DOCUMENT.
FREE ENGLISH SPEED QUEEN SCB30XG (01) PDF USER GUIDE.
FREE ENGLISH SPEED QUEEN SCB30XG (01) PDF USER MANUAL.
FREE ENGLISH SPEED QUEEN SCB30XG (01) PDF OWNER GUIDE.
FREE ENGLISH SPEED QUEEN SCB30XG (01) PDF OWNER MANUAL.
FREE ENGLISH SPEED QUEEN SCB30XG (01) PDF REFERENCE GUIDE.
FREE ENGLISH SPEED QUEEN SCB30XG (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH SPEED QUEEN SCB30XG (01) PDF REFERENCE MANUAL.
FREE ENGLISH SPEED QUEEN SCB30XG (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH SPEED QUEEN SCB30XG (01) PDF OPERATING INSTRUCTIONS.


CLICK HERE TO DOWNLOAD SPEED QUEEN SCB30XG (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What should I do with the instruction manual for my SPEED QUEEN SCB30XG tumbler?

Please read the enclosed instructions before using the machine. Keep these instructions for future reference. If the SPEED QUEEN SCB30XG tumbler changes ownership, be sure this manual accompanies the tumbler. A copy of the operating instructions must remain with the tumbler after installation.


What are the primary safety warnings for the SPEED QUEEN SCB30XG tumbler?

Failure to install, maintain, and/or operate the SPEED QUEEN SCB30XG according to the manufacturer’s instructions may result in conditions which can produce serious injury, death, and/or property damage.

To reduce the risk of fire, electrical shock, serious injury, or death, do not operate the tumbler if it does not perform according to these instructions. Immediately disconnect electrical service, shut off the gas supply, and contact an authorized service representative. Service and repairs are to be performed by authorized service representatives only.

When using the SPEED QUEEN SCB30XG, follow these basic precautions:

• Read all instructions before using the tumbler.

• DO NOT tamper with controls.

• DO NOT bypass any safety devices.

• Always follow the fabric care instructions supplied by the garment manufacturer.

• Remove laundry immediately after the tumbler stops.

• DO NOT reach into the tumbler if the cylinder is revolving.


What materials should never be dried in the SPEED QUEEN SCB30XG tumbler?

To avoid creating any flammable vapors which may explode, ignite, or cause corrosive damage, DO NOT dry the following materials in your SPEED QUEEN SCB30XG:

• Articles that have been cleaned in, soaked in, washed in, or spotted with gasoline, dry cleaning solvents, or other flammable/explosive substances.

• Plastics or articles containing foam rubber or similarly textured rubberlike materials.

• Articles that have traces of flammable substances like cooking oil, machine oil, flammable chemicals, or thinner.

• Articles containing wax or cleaning chemicals.

• Fiberglass curtains or draperies (unless the label says it can be done).


What are the general safety precautions for using the SPEED QUEEN SCB30XG dryer?

To reduce the risk of fire, electric shock, serious injury, or death to persons when using your SPEED QUEEN SCB30XG dryer, follow these basic precautions:

1. Do not allow children to play on or in the tumbler. Close supervision of children is necessary when the tumbler is used near children. This is a safety rule for all appliances.

2. Before the tumbler is removed from service or discarded, remove the door to the drying compartment.

3. Do not install or store the tumbler where it will be exposed to water and/or weather.

4. Failure to install, maintain, and/or operate this machine according to the manufacturer’s instructions may result in conditions which can produce serious injury, death, and/or property damage.

5. Run the tumbler with a load before putting it into service.

6. Always disconnect the electrical power to the tumbler before servicing. Disconnect power by shutting off the appropriate circuit breaker or fuse and by turning off the disconnect switch located on the rear of the tumbler.

7. If the emergency stop function is desired on coin-operated models, an external emergency stop switch may be installed as specified on the machine wiring diagram. Activation of the emergency stop switch stops all machine control circuit functions but does not remove all electrical power from the machine.


What do the warning labels on the SPEED QUEEN SCB30XG tumbler mean?

The following warning labels will be found on the SPEED QUEEN SCB30XG drying tumbler:

• **Fire Hazard Symbol:** A clothes dryer produces combustible lint. TUMBLER MUST BE EXHAUSTED OUTDOORS.

• **Rotating Parts Symbol:** Do not touch rotating parts.

• **Hot Surface Symbol:** Do not touch the surface until it has cooled.

• **Guards Symbol:** Do not operate without guards in place.

• **Electrical Shock Symbol:** Disconnect electrical power before servicing.

• **Combustion Gas Symbol:** To reduce the risk of accumulating unsafe concentrations of combustion gases, the tumbler MUST BE EXHAUSTED OUTDOORS.

• **General Warning Symbol:** WARNING!


What does the main warning label on the SPEED QUEEN SCB30XG state?

The main warning label on the SPEED QUEEN SCB30XG includes the following points:

– DO NOT put articles soiled with flammable liquids or flammable cleaning solvents in the dryer.

– DO NOT store or use flammable liquids near this appliance.

– DO NOT spray or store aerosols in the vicinity of this appliance.

– Various chemicals used in laundries contain chlorine. When decomposed in a flame, these materials may rapidly corrode and destroy this appliance.

– The dryer must be exhausted outdoors, and the area around the dryer must be free of lint because the dryer produces combustible lint.

– DO NOT dry articles containing foam rubber, plastic, or similarly textured rubberlike materials.

– Use for drying water-washed fabrics only.

– DO NOT put articles soiled with vegetable or cooking oil in the dryer as these oils may not be removed during washing. Due to the remaining oil, the fabric may catch on fire by itself.

– DO NOT reach into the dryer until all moving parts have stopped.

– DO NOT let children play in the dryer.


Where can I find the model and serial numbers on my SPEED QUEEN SCB30XG tumbler?

The model and serial numbers for your SPEED QUEEN SCB30XG tumbler will be found on the nameplate. The nameplate is located on the rear of the tumbler or underneath the door hinge.


What are the specifications for a 30 Pound Gas Tumbler like the SPEED QUEEN SCB30XG?

Cabinet Finish: Electrostatically applied thermosetting polyester
Cylinder: 30″ x 30″ (76.2 x 76.2 cm) perforated galvanized steel with three baffles; 30 pounds (13.6 kg) dry weight (cotton load)
Motor: 1/3 H.P., lifetime lubricated, internal overload protected
Electrical Requirements: 230 Volt, 50 Hertz, 1 Phase, 5.5 Amp
Gas Consumption: Energy Saver Models – 80,000 BTU per hour (84.4 MJ/hr.)
Standard Models – 105,000 BTU per hour (110.8 MJ/hr.)
Types of Gas: Factory equipped with Natural/Mixed Gas (6 1/2 ± 1 1/2 inch water column line pressure) (1.62 ± .37 kPa); or Liquefied Petroleum gas (11 ± .3″ water column line pressure) (2.74 ± .07 kPa)
Gas Connection: 1/2 inch (12.7 mm) N.P.T.
Air Flow: 600 C.F.M. at 0.5″ W.C. (283 liters/sec. at 1.25 mBar)
Net Weight: 450 Pounds (204 kg.) (approximate)
Calorific Value: Natural Gas – 8900 kCal/m³ (37.2 MJ/m³)
L.P. Gas – 22,250 kCal/m³ (93.1 MJ/m³)

What should I do upon receiving my new SPEED QUEEN SCB30XG tumbler?

Upon delivery, visually inspect the crate, carton, and parts for any visible shipping damage. If there is damage or signs of possible damage, have the carrier note the condition on the shipping papers before signing the receipt, or advise the carrier as soon as it is discovered. A written claim should be filed with the carrier immediately if articles are damaged or missing.

Remove the crate and protective cover and check items against the packing list. IMPORTANT: Remove shipping tape from the two back draft dampers located in the exhaust thimble.


What materials are required for installing a gas SPEED QUEEN SCB30XG tumbler?

The following materials, which should be obtained locally, are required for installation:

• One circuit breaker.

• One gas shut-off valve for the gas service line to the tumbler.


What are the facility requirements for installing a SPEED QUEEN SCB30XG tumbler?

FLOOR: The SPEED QUEEN SCB30XG tumbler may be installed on any level floor capable of supporting 100 pounds per square foot (488 kg/m²). Floor covering materials such as carpeting or tile should be removed.

LAYOUT: Whenever possible, the tumbler should be installed along an outside wall where duct length can be kept to a minimum, and make-up air can be easily accessed. Construction must not block airflow at the top rear of the tumbler, as this would prevent an adequate air supply to the tumbler’s combustion chamber.

VENTING: For maximum efficiency and minimum lint accumulation, tumbler air must be exhausted to the outdoors by the shortest possible route.

MAKE-UP AIR: The room must have adequate make-up air to replace the air exhausted by the tumbler.


What are the requirements for the exhaust duct on my SPEED QUEEN SCB30XG tumbler?

Properly sized exhaust ducts are essential for proper operation. All elbows should be sweep type. Exhaust ducts must be assembled so interior surfaces are smooth to reduce lint accumulation. Do not use sheet metal screws to join vent sections.

• **Material:** Exhaust ducts must be constructed of sheet metal or other noncombustible material, equivalent in strength and corrosion resistance to galvanized sheet steel not less than 0.0195 inches (0.495 mm) thick.

• **Clearance:** Where the exhaust duct pierces a combustible wall or ceiling, an opening with a diameter 4 inches (10.2 cm) larger than the duct must be provided, with the duct centered in the opening. The space around the duct must be sealed with non-combustible material.

• **Individual Venting:** It is preferred to exhaust the SPEED QUEEN SCB30XG individually to the outdoors. At no point may the cross area of the installed venting be less than the cross area of the tumbler’s exhaust thimble.

• **Maximum Length:** The maximum allowable length of venting is 14 feet (4.3 m) and two 90° elbows or equivalent. If the required length exceeds this, the duct diameter must be increased.

• **Airflow:** With the tumbler in operation, airflow at any point in the duct must be at least 1200 feet (366 m) per minute to ensure that lint remains airborne.


What are the make-up air requirements for a room with a SPEED QUEEN SCB30XG tumbler?

The SPEED QUEEN SCB30XG tumbler is a forced-air exhausted appliance and requires provisions for make-up air to replace the air it exhausts.

• **Recommended Opening:** The manufacturer’s recommended make-up air opening is 144 square inches (928 sq. cm) for each 30-pound tumbler.

• **Minimum Opening:** At a minimum, the tumbler must have at least 1 sq. inch (2.54 sq. cm) of opening for every 1000 BTU/hr of input rating for proper combustion.

• **Louvers:** Protective louvers in an opening to the outdoors can reduce air movement by approximately 40%. The opening must be sized larger to compensate for the area taken up by louvers.

• **Other Appliances:** Make-up air openings for a room containing the tumbler and/or other gas-fired appliances must be increased sufficiently to prevent downdrafts in any vents when all tumblers are in operation. Do not locate gravity-vented appliances between the tumbler(s) and make-up air openings.


What are the warnings regarding venting for my SPEED QUEEN SCB30XG tumbler?

WARNING: Solvent gases and vapors from dry cleaning machines create acids when drawn through the heater of a drying tumbler. These acids are corrosive to the drying tumbler as well as to the laundry load being dried. Be sure make-up air is free of solvent gases and vapors. If dry cleaning machines are in the same area as the tumbler, then the tumbler make-up air must come from a source free of solvent gases and vapors.

WARNING: To reduce the risk of fire and accumulation of combustible gases, DO NOT exhaust tumbler air into a window well, gas vent, chimney, or enclosed, unventilated area such as an attic wall, ceiling, crawl space under a building, or concealed space of a building.

NOTE: Do not install wire mesh or screen in the exhaust opening as lint will build up and prevent proper discharge of air from the tumbler.


How should my SPEED QUEEN SCB30XG tumbler be grounded?

The SPEED QUEEN SCB30XG tumbler must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. The tumbler must be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with the circuit conductors and connected to the PE Busbar.

WARNING: To reduce the risk of fire and electric shock, check with a qualified serviceman for proper grounding procedures. Improper connection of the equipment grounding conductor can result in a risk of electric shock.

WARNING: To reduce the risk of fire and electric shock, if the electrical supply is coming from a three-phase service, DO NOT connect a “Stinger Leg” to a single-phase machine.


How do I make the electrical connections to my SPEED QUEEN SCB30XG tumbler?

WARNING: All electrical connections should be made by a qualified electrician. To reduce the risk of electrical shock, de-energize the electrical circuit being connected to the tumbler before making any electrical connections. Never attempt to connect a live circuit.

Use the following steps to connect electrical service to the SPEED QUEEN SCB30XG tumbler:

1. Install a circuit breaker as close to the tumbler as possible. If more than one tumbler is being installed, a circuit breaker should be provided for each tumbler.

2. Follow these steps:

a. Connect conduit-encased leads to the circuit breaker.

b. Turn “off” the disconnect switch on the tumbler and open the junction box.

c. Insert conduit-encased leads through one of the knockout holes in the junction box.

d. Connect wire leads to the disconnect switch.

– **1 Phase Units:** Connect one lead to the top left connection point. Connect the other lead to the top right connection point.

– **3 Phase Units:** Connect one lead to each connection point.

e. Connect a ground wire to the PE Busbar in the junction box.

3. For three-phase units, check the electrical service phase sequence.

4. Close the junction box cover and turn “on” the disconnect switch.


How do I position and level my SPEED QUEEN SCB30XG tumbler?

The SPEED QUEEN SCB30XG tumbler may be removed from its shipping skid before moving to the installation location. Remove the tumbler from the skid by unscrewing the four shipping capscrews (one at each corner). The lint panel door will have to be removed to access the two front capscrews. NOTE: Do not throw these four capscrews away; they are the leveling legs.

Screw the four leveling legs back into the level adjusting fittings from the top. Slide the tumbler to its permanent location. Keep the tumbler as close to the floor as possible. All four legs must rest firmly on the floor so the weight is evenly distributed and the tumbler does not rock.

The tumbler should be leveled within 1/8 inch (3.2 mm) from front to rear, and 1/8 inch (3.2 mm) from side to side. Check the front-to-rear level by rotating the cylinder until one rib is at the bottom, then placing a level on that bottom rib. The side-to-side level should be checked by placing a level on the front and rear of the top panel.


What are the gas requirements for the SPEED QUEEN SCB30XG tumbler?

The size of the gas service pipe depends on many variables. Specific pipe size information should be obtained from your gas supplier. It is important that equal gas pressure be maintained at all tumbler gas connections, which can be achieved by installing a one-inch pipe gas loop.

WARNING: To reduce the risk of fire or explosion, if the SPEED QUEEN SCB30XG tumbler is to be connected to Liquefied Petroleum (L.P.) gas, a vent to the outdoors must be provided in the room where the tumbler is installed.


How do I connect the gas supply to my SPEED QUEEN SCB30XG tumbler?

Before connecting gas piping to the SPEED QUEEN SCB30XG, make certain the gas service is the same as specified on the nameplate.

• **Natural Gas:** Must be supplied at 6 1/2 ± 1 1/2 inch water column pressure (1.62 ± .37 kPa).

• **L.P. Gas:** Must be supplied at 11 ± .3 inch water column pressure (2.74 ± .07 kPa).

If the gas service is not the same as specified, DO NOT CONNECT THE GAS LINE. The gas burner orifice and gas valve must be converted first by authorized personnel.

Connection Steps:

1. Purge air and sediment from the gas service line before connecting it loosely to the tumbler.

2. Purge the remaining air until the odor of gas is detected, then tighten the connection.

3. Use pipe compound resistant to the actions of L.P. gas on all pipe threads.

WARNING: Check all pipe connections, internal and external, for gas leaks using a soapy solution. To reduce the risk of explosion or fire, DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS! Gas connections should be checked annually for leakage.

WARNING: The tumbler and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPa). The tumbler must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 psig (3.45 kPa).


How do I light and shut down the gas ignition system on my SPEED QUEEN SCB30XG tumbler?

Lighting the System:

1. Turn the machine disconnect switch, located on the rear of the tumbler, to the “on” position.

2. Turn the gas shut-off valve, located on the rear of the tumbler, to the “on” position (gas valve handle should be parallel with the gas line).

3. Start the tumbler, following the operating instructions that accompanied it.

Shutting Down the System:

If the tumbler will not start, remove it from service by turning the machine disconnect switch to the “off” position and turning the gas shut-off valve to the “off” position (gas valve handle should be at a right angle to the gas line).


What happens if ignition does not occur on my SPEED QUEEN SCB30XG, and how do I reset the system?

The ignition control circuitry on your SPEED QUEEN SCB30XG will verify the airflow switch is open before starting. Once the motor starts, the airflow switch closes, and the tumbler will purge air for 18 seconds. Ignition will then start with a three-second release of gas and sparking of the ignitor.

If ignition does not occur during this first three seconds, the ignition control will “lockout,” causing the gas valve to close and a red button on the ignition control to illuminate.

To reset the ignition system, open the access door and press the red button on the ignition control. Close and lock the access door, verify that the gas shut-off valve is in the “on” position, and attempt to start the tumbler again.


What preliminary operating checks should be performed on my SPEED QUEEN SCB30XG tumbler after installation?

1. Remove or open all panels and inspect accessible bolts, nuts, screws, terminals, and fittings for security.

2. Check belt tension and adjust if necessary (refer to the Adjustment Section).

3. Energize the electrical circuit to the tumbler circuit breaker and turn on the tumbler disconnect switch.

4. Turn on the gas supply at the manual gas shut-off valve in the gas supply line. The handle should be parallel with the gas supply line when in the “ON” position.

5. Press and hold the Push-to-Start Button for approximately three (3) seconds. Release the button and open the cylinder door. The cylinder should stop rotating within seven (7) seconds after the door is opened 3″ (7.5 cm) plus or minus 1/4″ (0.635 cm). If it doesn’t stop, adjust the cylinder door interlock.

6. Load the tumbler with clothes or clean rags.

7. Start the tumbler and check the burner flame, adjusting the gas inlet shutter if necessary.

8. Check the airflow switch operation by opening the lint panel. The heating system should shut off when the lint panel is opened approximately 1-1/2″ (3.81 cm).

9. Turn off the tumbler.

10. Check the airflow switch operation again by opening the lint panel with a full load. The heating system should shut off when the lint panel is opened approximately 6″ (15.24 cm).


How do I operate a coin-operated SPEED QUEEN SCB30XG tumbler?

1. Set the temperature selector to HIGH.

2. Insert the required amount of coins.

3. Press and hold the Push-to-Start Button for approximately three (3) seconds. The motor will start and the heat system will turn on.

4. Near the end of the cycle, a preset 2 1/2 minute cool-down cycle will start.

5. When the metered time expires, the motor will stop, indicating the drying cycle is finished.


How do I adjust the main gas burner air shutter on my SPEED QUEEN SCB30XG tumbler?

NOTICE: Both air inlet shutters on the burner must be adjusted for proper combustion and maximum efficiency. Before adjusting, ensure all lint is removed from the lint compartment and screen.

1. Unlock and open the access door.

2. Start the tumbler and check the flame pattern. A correct mixture is indicated if the flame is primarily blue with small yellow tips and bends to the right of the heater section. Too little air is indicated if the flame is yellow, lazy, and smoky.

3. To adjust, loosen the air inlet shutter adjusting screw.

4. Open or close the air shutter as necessary to obtain the proper flame intensity.

5. After adjustment, tighten the air shutter adjusting screw securely.

6. If the shutter is correctly adjusted but the flame pattern is straight up, it indicates insufficient primary air. A flame pattern that flares to the right and left indicates no air is flowing through the tumbler.


How do I adjust the air flow switch on my SPEED QUEEN SCB30XG tumbler?

WARNING: Air flow switch operation may be affected by a clogged lint screen, lack of make-up air, or obstructions in ducts. These conditions must be checked and corrected before adjusting the switch. Always adjust airflow at installation.

The counterweight should be adjusted so airflow will force the disc away from the cabinet when the lint panel is opened 6 inches (15.24 cm) with a full load. To adjust:

1. Load the tumbler.

2. Start the tumbler. Open the lint panel 6 inches (15.24 cm). The airflow disc should move away from the cabinet, opening the switch contacts and shutting off the heat. This indicates proper adjustment.

3. If the switch does not open as described, it needs to be MORE sensitive. Depress the spring clip and move the counterweight toward the disc. Retest and continue moving it toward the disc until it operates correctly.

4. If the switch opens BEFORE the lint panel is opened the proper distance, it needs to be LESS sensitive. Depress the spring clip and move the counterweight away from the disc. Retest and continue moving it away from the disc until it operates correctly.


How do I adjust the loading door switch on my SPEED QUEEN SCB30XG tumbler?

The loading door switch turns off the tumbler anytime the loading door is opened. To adjust it, follow these steps:

1. Start the tumbler following its operating instructions.

2. Slowly open the loading door. The cylinder and heating system should stop when the door is open 3 inches (7.5 cm) plus or minus 1/4 inch (0.635 cm).

3. Slowly close the loading door. The switch should close with an audible “click” when the door is closed 3 inches (7.5 cm) plus or minus 1/4 inch (0.635 cm).

4. If the switch does not close at the correct point:

a. Close the loading door completely.

b. Loosen the lower screw on the switch coupler and rotate the coupler COUNTERCLOCKWISE until it stops.

c. Tighten the lower screw on the switch coupler.

d. Return to step 1 to verify the new adjustment.


How do I adjust the cylinder door strike on my SPEED QUEEN SCB30XG tumbler?

The door strike must be adjusted to have sufficient tension to hold the loading door closed against the force of a tumbling load. Proper adjustment is when 8 to 15 pounds (35.6 N – 66.7 N) of pull is required to open the door.

To adjust, open the door, loosen the jamnut on the door strike, and turn the door strike screw in or out as required. Retighten the jamnut when finished.


How do I adjust the drive V-belt on my SPEED QUEEN SCB30XG tumbler?

WARNING: To reduce the risk of serious injury or death, disconnect power to the tumbler before performing this operation.

Proper tension is when the belt can be depressed approximately 1/2 inch (1.27 cm) with light thumb pressure at a point midway between the sheave and motor pulley.

1. Remove the guard from the rear of the tumbler.

2. To adjust belt tension, loosen the adjusting bolt that holds the idler housing assembly to the housing support.

3. **To tighten V-belt:**

a. Loosen the lower nut on the adjusting bolt.

b. Turn the bolt up until the belt has proper tension.

c. Tighten the upper and lower nut or adjusting bolt.

4. **To loosen V-belt:**

a. Loosen the top nut on the adjusting bolt.

b. Turn the bolt down until the belt has proper tension.

c. Tighten the upper and lower nut or adjusting bolt.

5. Replace the guard on the rear of the tumbler. The upper belt requires no adjustment as it is self-adjusting.

WARNING: To reduce the risk of serious injury or death, the guard MUST be installed on the rear of the tumbler after belt adjustment is made.


What daily preventive maintenance is required for the SPEED QUEEN SCB30XG tumbler?

1. Make certain the drying cycle has ended.

2. Open the loading door.

3. Unlock and remove the lint panel.

4. Remove accumulated lint in the lint compartment. Lint left in the compartment will be drawn back onto the lint screen and restrict air circulation.

5. Clean lint from the lint screen. If the lint screen is torn, replace it immediately.

6. Ensure the lint screen covers the entire opening in the lint screen hood. Gaps will allow lint to flow into the ductwork.

7. Wipe any accumulated lint off the thermostat sensing probe. Lint buildup on the probe will cause overheating.

8. Replace and securely lock the lint panel.


What monthly preventive maintenance is required for the SPEED QUEEN SCB30XG tumbler?

1. Perform daily cleaning of accumulated lint.

2. Deactivate the electrical circuit by turning off the electrical disconnect switch on the rear of the tumbler.

4. Remove the exhaust duct from the rear of the tumbler and clean out all accumulated lint.

5. Reinstall the exhaust duct.

6. Remove the bottom cover from the vertical exhaust duct and clean out all accumulated lint.

7. Reinstall the vertical exhaust duct cover.

8. Inspect the entire duct work assembly and clean out all accumulated lint.

9. Energize the electrical circuit to the tumbler by turning on the electrical disconnect switch on the rear of the tumbler.


What quarterly preventive maintenance is required for the SPEED QUEEN SCB30XG tumbler?

1. Deactivate the electrical circuit by turning off the disconnect switch on the rear of the tumbler.

2. Perform daily cleaning of accumulated lint.

3. Perform monthly inspection and cleaning of accumulated lint.

4. Clean accumulated lint and other debris from the front and back motor air vents.

5. Shut off the gas supply at the manual gas shut-off valve in the gas supply line. The handle should be at a 90° angle to the gas supply line when in the “OFF” position.

6. Remove the screws holding the rear drive guard to the back of the tumbler.

7. Inspect belts for wear and proper tension (refer to the Adjustments section).

8. Reinstall the rear drive guard to the back of the tumbler.

9. Energize the electrical circuit to the tumbler by turning on the electrical disconnect switch on the rear of the tumbler.

10. Turn on the gas supply at the manual gas shut-off valve. The handle should be parallel with the gas supply line when in the “ON” position.


What biannual preventive maintenance is required for the SPEED QUEEN SCB30XG tumbler?

1. Deactivate the electrical circuit by turning off the disconnect switch on the rear of the tumbler.

2. Perform daily cleaning of accumulated lint.

3. Perform monthly inspection and cleaning of accumulated lint.

4. Perform quarterly inspection and cleaning of accumulated lint.

5. Remove or open all panels and check accessible bolts, nuts, screws, terminals, and fittings for tightness.

6. Shut off the gas supply at the manual gas shut-off valve. The handle should be at a 90° angle to the gas supply line when in the “OFF” position.

7. Unlock and open the service panel and inspect gas connections for evidence of leakage or loose connections. NOTE: Spraying a mild solution of soap and water on joints will cause bubbles to appear on any leaking connections.

8. Close and securely lock the service panel.

9. Open the electrical junction box cover and inspect all electrical and grounding connections for security. Tighten any loose electrical connections.

10. Close the electrical junction box cover and energize the electrical circuit by turning on the electrical disconnect switch.

11. Turn on the gas supply at the manual gas shut-off valve. The handle should be parallel with the gas supply line when in the “ON” position.


What is the maintenance check chart for my SPEED QUEEN SCB30XG tumbler?

QUARTERLY MAINTENANCE

Clean air vents on drive motor.
Clean exhaust ducts.
Check flow of combustion air.
Check flow of ventilation air.
Check belt tension.

BIANNUAL MAINTENANCE

Check for loose nuts.
Check for loose bolts.
Check for loose screws.
Check for loose gas connections.
Check for loose electrical connections.

How do I decommission my SPEED QUEEN SCB30XG tumbler?

1. Turn off the electrical supply external to the machine.

2. Turn off the electrical disconnect on the machine.

3. Turn off the gas supply external to the machine.

4. Turn off the manual gas shut-off valve on the machine.

5. Remove all electric and gas connections.


CLICK HERE TO DOWNLOAD SPEED QUEEN SCB30XG (01) PDF DOCUMENT