Free English HIKVISION DS-K1T607TMF (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD HIKVISION DS-K1T607TMF (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
What do the symbols in the user manual for the HIKVISION DS-K1T607TMF mean?
The symbols found in the document are defined as follows:
| Symbol | Description |
|---|---|
| Danger | Indicates a hazardous situation which, if not avoided, will or could result in death or serious injury. |
| Caution | Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance degradation, or unexpected results. |
| Note | Provides additional information to emphasize or supplement important points of the main text. |
What are the key safety instructions for using the HIKVISION DS-K1T607TMF?
To ensure the HIKVISION DS-K1T607TMF is used correctly and to avoid danger or property loss, please follow these safety instructions.
Dangers:
• All electronic operations should be in strict compliance with electrical safety regulations, fire prevention regulations, and other related regulations in your local region.
• Use the provided power adapter. This equipment is intended to be supplied from a Class 2 surge-protected power source rated DC 12V, 3A.
• Do not connect several devices to one power adapter as an overload may cause overheating or a fire hazard.
• Ensure power is disconnected before you wire, install, or dismantle the device.
• When installed on a wall or ceiling, the device must be firmly fixed.
• If smoke, odors, or noise rise from the device, turn off the power at once, unplug the power cable, and contact the service center.
• Do not ingest the battery; it is a Chemical Burn Hazard. This product contains a coin/button cell battery which can cause severe internal burns and lead to death if swallowed.
• If the product does not work properly, contact your dealer or the nearest service center. Do not attempt to disassemble the device yourself.
Cautions:
• Do not drop the device or subject it to physical shock. Avoid high electromagnetism radiation and do not install on vibration surfaces.
• Do not place the device in extremely hot, cold, dusty, or damp locations.
• The device cover for indoor use should be kept from rain and moisture.
• Do not expose the equipment to direct sunlight, low ventilation, or heat sources like heaters or radiators.
• Do not aim the device at the sun or extra bright places.
• Use the provided glove when opening the device cover to avoid direct contact, as acidic sweat can erode the surface coating.
• Use a soft, dry cloth for cleaning. Do not use alkaline detergents.
• Keep all original wrappers for future use. Transportation without the original wrapper may cause damage.
• Improper use or replacement of the battery may result in an explosion hazard. Replace only with the same or equivalent type.
• Biometric recognition products are not 100% applicable to anti-spoofing environments. For higher security, use multiple authentication modes.
• Working temperature is -30 °C to +60 °C.
• For indoor installation, the device should be at least 2 meters from any light source and 3 meters from a window or door. For outdoor installation, apply silicone sealant around the cable wiring area to prevent rain from entering.
• The protection level is IP65.
What are the different models and required power supplies for the HIKVISION DS-K1T607TMF series?
The available models for the Face Recognition Terminal are:
- DS-K1T607M
- DS-K1T607MF
- DS-K1T607E
- DS-K1T607EF
- DS-K1T607MW
- DS-K1T607MFW
- DS-K1T607PE
- DS-K1T607PEF
- DS-K1T607PMW
- DS-K1T607PMFW
- DS-K1T607TM
- DS-K1T607TMF
- DS-K1T607TE
- DS-K1T607TEF
- DS-K1T607TMW
- DS-K1T607TMFWW
Use only the power supplies listed in the user instructions:
| Model | Manufacturer | Standard |
|---|---|---|
| C2000IC12.0-24P-DE | MOSO Power Supply Technology Co., Ltd. | CEE |
| C2000IC12.0-24P-GB | MOSO Power Supply Technology Co., Ltd. | BS |
| KPL-040F-VI | Channel Well Technology Co Ltd. | CEE |
What are the main components of the HIKVISION DS-K1T607TMF?
The following table describes the components of the HIKVISION DS-K1T607TMF Face Recognition Terminal.
| No. | Name | Description |
|---|---|---|
| 1 | Fingerprint Module | For fingerprint recognition. Note: Only parts of models support fingerprint recognition function. |
| 2 | Card Swiping Area | Swipe card within this area. |
| 3 | Display Screen | 7-inch LCD touch screen. |
| 4 | Camera (IR Light) | IR light camera for recording or capturing videos or pictures in IR light. |
| 5 | Camera (White Light) | White light camera for recording or capturing white light videos or pictures. |
| 6 | Supplement Light (White Light) | Supplement light for white light camera. |
| 7 | Supplement Light (IR Light) | Supplement light for IR camera. |
| 8 | Supplement Light (IR Light) | Supplement light for IR camera. |
| 9 | USB Interface | Connect to USB flash drive. |
| 10 | Network Interface | Connect to Ethernet. |
| 11 | SIM Card Slot | Reserved |
| 12 | Debugging Port | The debug terminal is used for debugging only. |
| 13 | Power Interface | Connect to power supply. |
| 14 | Wiring Terminals | Connect to other external devices, including RS-485 card reader, Wiegand card reader, door lock, alarm input, alarm output, etc. |
| 15 | PSAM Card Slot | Reserved |
How do I install the HIKVISION DS-K1T607TMF with a gang box?
Follow these steps to install your HIKVISION DS-K1T607TMF using a gang box.
1. According to the datum line on the mounting template, stick the mounting template on the wall or other surface, 1.4 meters higher than the ground.
2. Drill holes on the wall or other surface according to the mounting template and install the gang box.
3. Use two supplied screws (4_KA4 × 22-SUS) to secure the mounting plate on the gang box.
4. Use another four supplied screws to secure the mounting plate on the wall.
5. Remove the two screws on the rear panel and remove the sheet to display the wiring terminals.
6. Route the cable through the cable hole of the mounting plate, and connect to corresponding external devices’ cables.
7. Install the sheet back to the device with the two screws.
8. Apply Silicone sealant among the cable wiring area to keep the raindrop from entering.
9. Optional: Insert the fingerprint module to the holes at the bottom of the main part.
10. Align the device with the mounting plate and hang the device on the mounting plate.
11. Use two supplied screws (SC-M4 × 12TP10-SUS) to secure the device and the mounting plate.
How do I install the HIKVISION DS-K1T607TMF without a gang box?
Follow these steps to install your HIKVISION DS-K1T607TMF without a gang box.
1. According to the datum line on the mounting template, stick the mounting template on the wall or other surface, 1.4 meters higher than the ground.
2. Drill 6 holes on the wall or other surface according to Hole 1 and Hole 2 in the mounting template.
3. Insert the screw sockets of the setscrews in the drilled holes.
4. Align the 6 holes of the mounting plate with the drilled holes and use the six supplied screws to secure the plate.
5. Remove the two screws on the rear panel and remove the sheet to display the wiring terminals.
6. Route the cable through the cable hole of the mounting plate, and connect to corresponding external devices’ cables.
7. Install the sheet back to the device with the two screws.
8. Apply Silicone sealant among the cable wiring area to keep the raindrop from entering.
9. Insert the fingerprint module to the holes at the bottom of the main part.
10. Align the device with the mounting plate and hang the device on the mounting plate.
11. Use two supplied screws (SC-M4 × 12TP10-SUS) to secure the device and the mounting plate.
What are the terminal descriptions for wiring the HIKVISION DS-K1T607TMF?
The terminals on the HIKVISION DS-K1T607TMF contain inputs for power, alarm, RS-485, Wiegand, and door lock. The descriptions are as follows:
| Group | No. | Function | Color | Name | Description |
|---|---|---|---|---|---|
| Group A | A1 | Power Input | Red | +12 V | 12 VDC Power Supply |
| A2 | Black | GND | Ground | ||
| Group B | B1 | Alarm Input | Yellow/Blue | IN1 | Alarm Input 1 |
| B2 | Yellow/Black | GND | Ground | ||
| B3 | Alarm Output | Yellow/Orange | IN2 | Alarm Input 2 | |
| B4 | Yellow/Purple | NC | Alarm Output Wiring | ||
| B5 | Yellow/Brown | COM | |||
| Group C | B6 | Yellow/Red | NO | ||
| C1 | RS-485 | Yellow | 485+ | RS-485 Wiring | |
| C2 | Blue | 485- | |||
| C3 | Black | GND | Ground | ||
| C4 | Wiegand | Green | W0 | Wiegand Wiring 0 | |
| C5 | White | W1 | Wiegand Wiring 1 | ||
| C6 | Brown | WG_OK | Wiegand Authenticated | ||
| C7 | Orange | WG_ERR | Wiegand Authentication Failed | ||
| C8 | Purple | BUZZER | Buzzer Wiring | ||
| C9 | Gray | TAMPER | Tampering Alarm Wiring | ||
| Group D | D1 | Door Lock | White/Purple | NC | Lock Wiring (NC) |
| D2 | White/Yellow | COM | Common | ||
| D3 | White/Red | NO | Lock Wiring (NO) | ||
| D4 | Yellow/Green | SENSOR | Door Contact | ||
| D5 | Yellow/Gray | BTN | Exit Door Wiring |
How do I activate the HIKVISION DS-K1T607TMF directly on the device?
You must activate the HIKVISION DS-K1T607TMF before the first login. If the device is not activated, you can activate it after it is powered on.
On the Activate Device page, create a password and confirm the password. Tap Activate, and the device will be activated.
Caution: It is highly recommended to create a strong password (minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) to increase security. Reset your password regularly.
How do I activate the HIKVISION DS-K1T607TMF using SADP software?
SADP is a tool to detect, activate, and modify the IP address of the device over the LAN.
Before You Start:
• Get the SADP software and install it.
• The device and the PC running the SADP tool should be within the same subnet.
Steps:
1. Run the SADP software and search for online devices.
2. Find and select your device in the online device list.
3. Input a new password (admin password) and confirm it.
4. Click Activate to start activation. The status of the device will become Active.
5. To modify the IP address:
1) Select the device.
2) Change the device IP address to the same subnet as your computer by either modifying the IP address manually or checking Enable DHCP.
3) Input the admin password and click Modify to activate your IP address modification.
How do I activate the HIKVISION DS-K1T607TMF via client software?
You are required to create a password to activate certain devices before they can be added to the software.
Steps:
1. Enter the Device Management page in the client software.
2. Click on the right of Device Management and select Device.
3. Click Online Device to show the online device area. The searched online devices will be displayed.
4. Check the device status (shown in the Security Level column) and select an inactive device.
5. Click Activate to open the Activation dialog.
6. Create a password in the password field, and confirm the password.
7. Click OK to activate the device.
How do I set the application and recognition modes on the HIKVISION DS-K1T607TMF after activation?
After activating the device, you should select an application and recognition mode for better performance.
Set Application Mode:
1. On the Welcome page, select Indoor or Others from the drop-down list.
• If you install the device indoors near a window or if face recognition is not working well, select Others.
• If you don’t configure this, the system will select Indoor by default.
2. Tap OK to save.
Set Recognition Mode:
1. On the Welcome page, after selecting the application mode, select Normal Mode or Deep Mode from the drop-down list.
• Normal Mode: Recognizes faces via the camera normally.
• Deep Mode: Recognizes a much wider range of people, suitable for more complicated environments.
• Note: Normal and deep modes cannot be compatible. It is suggested not to change this parameter once configured.
2. Tap OK to save.
How do I log in to the HIKVISION DS-K1T607TMF?
You can log in for the first time using the activation password, or log in as an administrator after one has been added.
Login For First Login:
1. Long tap on the initial page for 3 seconds to enter the password entering page.
2. Tap the Password field and enter the device activation password.
3. Tap OK to enter the home page.
Note: The device will be locked for 30 minutes after 5 failed password attempts.
Login by Administrator:
After you add an administrator for the device, only the administrator can log in for device operation.
1. Long tap on the initial page for 3 seconds to enter the admin login page.
2. Authenticate the administrator’s face, fingerprint, or card to enter the home page.
Note: The device will be locked for 30 minutes after 5 failed fingerprint or card attempts.
Optional: You can tap the lock icon to enter the device activation password for login, or tap the exit button to exit the admin login page.
How do I configure communication settings on the HIKVISION DS-K1T607TMF?
You can set network, Wi-Fi, RS-485, and Wiegand parameters in the communication settings.
Set Network Parameters:
1. Tap Comm. (Communication Settings) on the Home page.
2. Tap Network to enter the Network tab.
3. Tap IP Address, Subnet Mask, or Gateway and input the parameters.
4. Tap OK to save the settings.
Set Wi-Fi Parameters:
1. On the Communication Settings page, tap Wi-Fi.
2. Enable the Wi-Fi function.
3. Select a Wi-Fi network and choose an IP mode (Static or Dynamic), then input the required password and network details.
4. Tap OK to save the settings.
Set RS-485 Parameters:
1. On the Communication Settings page, tap RS-485.
2. Select an external device (Controller, Unit, or Reader) according to your needs.
3. If connecting an access controller or card reader, set the RS-485 address to 2.
4. Tap the save icon. The device will reboot if you change the external device.
Set Wiegand Parameters:
1. On the Communication Settings page, tap Wiegand.
2. Enable the Wiegand function.
3. Select a transmission direction (Output for access controller, Input for Wiegand card reader).
4. Tap the save icon. The device will reboot if you change this setting.
How do I add users and their credentials on the HIKVISION DS-K1T607TMF?
On the user management interface, you can add, edit, delete, and search users.
1. Add User (General Steps):
1. Tap User → + to enter the Add User page.
2. Edit the employee ID (less than 32 characters, no duplicates, cannot start with 0).
3. Tap the Name field and input the user name.
2. Add Face Picture:
1. On the Add User page, tap the Face Picture field.
2. Position your face looking at the camera. Ensure your face is within the outline and the picture is of good quality.
3. Tap Save to save the face picture. The maximum duration for adding a face is 15s.
3. Add Fingerprint:
1. On the Add User page, tap the Fingerprint field.
2. Place your finger on the fingerprint module and follow the on-screen instructions.
3. After adding, tap Yes to save and continue adding another fingerprint, or No to save and return to the Add User page. Up to 10 fingerprints can be added per user.
4. Add Card:
1. On the Add User page, tap the Card field.
2. Configure the card No. by entering it manually or swiping the card over the card swiping area.
3. Optionally, enable the Duress Card function.
5. Add Password:
1. On the Add User page, tap the Password field.
2. Create a password (numbers only, up to 8 characters) and confirm it.
6. Set Authentication Mode:
1. On the Add User or Edit User page, tap Authentication Mode.
2. Select Device or Custom mode. For Custom, you can combine different authentication modes.
7. Finalize and Save:
1. Enable Administrator Permission if the user is an administrator.
2. Tap the save icon to save all settings for the user.
How do I import and export data on the HIKVISION DS-K1T607TMF using a USB flash drive?
You can import or export user data, pictures, and parameters using a USB flash drive via the Transfer page.
Export Data:
1. Tap Transfer on the Home page.
2. Tap Export Att. Data, Export User Data, Export Face Pic., Export Access Control Param., or Export Captured Pic.
3. Tap Yes on the pop-up page. The data will be exported to the USB flash drive.
Note: The supported USB flash drive format is DB. The system supports drives with storage from 1G to 32G. Ensure free space is more than 512M.
Import Data:
1. Plug a USB flash drive into the device.
2. On the Transfer page, tap Import User Data, Import Face Pic., or Import Access Control Param.
3. Tap Yes on the pop-up window. The data will be imported from the USB flash drive.
Note: The supported USB flash drive format is FAT32. For picture import, the images should be in a root directory folder named ‘enroll_pic’, and the file name must follow the rule: Card No._Name_Department_Employee ID_Gender.jpg. The picture should be a full-face view, JPG/JPEG format, 640×480 pixels or more, and between 60 KB and 200 KB.
What are the different identity authentication methods on the HIKVISION DS-K1T607TMF?
The HIKVISION DS-K1T607TMF supports several authentication methods, primarily categorized as 1:1 Matching and 1:N Matching.
• 1:N Matching: Compares the captured face picture or collected fingerprint with all face/fingerprint pictures stored in the device. If the authentication mode is just “Face”, you position your face looking at the camera to start authentication.
• 1:1 Matching: Compares the captured face or fingerprint with a specific user’s stored data, usually initiated by presenting a card.
How to Authenticate via 1:1 Matching (e.g., Card and Face):
1. Swipe your card in the card swiping area.
2. Position your face looking at the camera to authenticate your face.
If the mode is Card and Face and Fingerprint, you would swipe your card, authenticate your face, and then authenticate your fingerprint when prompted.
How to Authenticate via 1:1 and 1:N Matching (e.g., Fingerprint and Face):
1. Authenticate your fingerprint first. The device compares it with all fingerprints in the database (1:N Matching).
2. When prompted, position your face looking at the camera. The device compares the captured face with the user information gained from the fingerprint step (1:1 Matching).
If authentication is successful, the prompt “Authenticated” will pop up.
How do I adjust the basic system settings on the HIKVISION DS-K1T607TMF?
On the Home page, tap System (System Settings) to enter the System Settings page. Here you can configure various basic parameters.
| Parameter | Description |
|---|---|
| Community No. | Set the device’s installed community No. |
| Building No. | Set the device’s installed building No. |
| Unit No. | Set the device’s installed Unit No. |
| Voice Prompt | Tap to disable or enable the voice prompt. |
| Voice Volume | Adjust the voice volume. The larger the value, the louder the volume. |
| Application Mode | You can select either others or indoor according to the actual environment. |
| Wake-up Distance | The live view on the device screen will enter the IR mode based on distance. |
| IR Light Brightness | Set the IR light brightness when the IR light is enabled. |
| White Light Brightness | Set the supplement white light’s brightness. The brightness ranges from 0 to 100. 0 is off, 1 is darkest, 100 is brightest. |
How can I configure the face picture parameters for the HIKVISION DS-K1T607TMF?
On the Home page, tap System, then go to the Face Pic. tab to adjust face recognition parameters.
| Parameter | Description |
|---|---|
| 1:N Security Level | Set the matching threshold for 1:N matching. A larger value means a smaller false accept rate but a larger false rejection rate. |
| 1:1 Security Level | Set the matching threshold for 1:1 matching. A larger value means a smaller false accept rate but a larger false rejection rate. |
| Recognition Interval | Set the time interval (1 to 10) between two continuous face recognitions. |
| Face Anti-Spoofing | Enable or disable the face anti-spoofing function to detect if the person is live. |
| Liveness Security Level | After enabling Live Face Detection, set the matching security level for it. |
| Margin (Left/Top/Right/Bottom) | Defines the required minimum distance from the edge of the face to the edge of the recognition area. |
| Pitch Angle | The maximum pitch angle (up/down tilt) when starting face authentication. |
| Yaw Angle | The maximum yaw angle (left/right turn) when starting face authentication. |
| Pupillary Distance | The minimum resolution between two pupils when starting face recognition. |
| WDR Level | Enables the Wide Dynamic Range function to balance brightness in scenes with both very bright and dark areas. 0 is disabled. |
| ECO Mode | Enables authentication in low light or dark environments. (Only available in normal mode). |
| ECO Mode Threshold | Sets the threshold for entering ECO mode. The larger the value (0-7), the easier it enters ECO mode. |
| ECO Mode (1:N) / (1:1) | Sets the matching threshold when authenticating in ECO mode. |
How do I set the time and attendance status on the HIKVISION DS-K1T607TMF?
You can set the attendance mode as Disable, Manual, Auto, or Manual and Auto. This function should be used in cooperation with the time and attendance function on the client software. To begin, tap T&A Status on the Home page.
Disable Attendance Mode:
Set the Attendance Mode to Disable. You will not view or configure the attendance status on the initial page.
Set Manual Attendance:
1. Set the Attendance Mode to Manual.
2. Enable the Attendance Status function.
3. You must select the attendance status (e.g., Check In, Check Out) manually after authentication.
Set Auto Attendance:
1. Set the Attendance Mode to Auto.
2. Select an attendance status (e.g., Check In, Break Out) and set its available schedule. The system will automatically mark the attendance status based on the time of authentication according to the configured schedule.
Set Manual and Auto Attendance:
1. Set the Attendance Mode to Manual and Auto.
2. The system will automatically change the attendance status according to the configured schedule, but you can also manually change it after authentication.
What access control parameters can be configured on the HIKVISION DS-K1T607TMF?
On the Home page, tap ACS (Access Control Settings) to edit the access control parameters. The available parameters are:
| Parameter | Description |
|---|---|
| Terminal Auth. Mode | Select the face recognition terminal’s authentication mode (e.g., Face, Card/Face/FP). You can also customize the authentication mode. |
| Reader Auth. Mode | Select the external card reader’s authentication mode. |
| NFC Anti-Cloning | Enable this function to prevent the use of a cloned card for authentication. |
| Door Contact | Select “Open (Remain Open)” or “Close (Remain Closed)”. By default, it is Close. |
| Anti-Passback | When enabled, a person must authenticate according to the configured path set in the client software, or authentication will fail. |
| Door Locked Time | Set the door unlocking duration (1 to 255s). If the door is not opened within this time, it will lock again. |
| Door Open Timeout Alarm | The alarm will be triggered if the door remains open past the set time (0 to 255s). |
| Continuous Failed Auth. Alarm | When enabled, an alarm will be triggered if authentication fails for the set number of times. |
How do I perform maintenance tasks like upgrading firmware on the HIKVISION DS-K1T607TMF?
You can perform various maintenance tasks such as upgrading firmware and managing data.
Upgrade Firmware:
1. Plug in a USB flash drive containing the upgrade file.
2. Tap Maint. (Maintenance) on the System Settings page.
3. Tap Upgrade. The device will automatically read the file and upgrade the firmware.
Note: Do not power off during the upgrade. The upgrading file should be in the root directory and named digicap.dav.
Data Management:
1. Tap Data (Data Management) on the Home page.
2. Tap a button to manage data as described below:
| Parameter | Description |
|---|---|
| Delete All Events | Delete all events stored in the device. |
| Delete User Data | Delete all user data in the device. |
| Delete Captured Pic. | Delete the device captured pictures. |
| Restore to Factory | Restore the system to factory settings. The device will reboot. |
| Restore to Default | Restore the system to default settings, saving communication and remote user settings. The device will reboot. |
Log Query:
1. On the Home page, tap Log.
2. Select a search type (e.g., Card, Name).
3. Input the employee ID, card No., or user name.
4. Select a time period (Custom, Yesterday, etc.).
5. Tap the search icon to view the results.
How do I use the two-way audio feature on the HIKVISION DS-K1T607TMF?
After adding the HIKVISION DS-K1T607TMF to the client software, you can initiate two-way audio calls with various devices.
Call Client Software from Device:
1. Add the device to the client software.
2. On the device’s initial page, tap Call.
3. Input 0 in the pop-up window and tap Call.
4. Tap Answer on the pop-up page in the client software to start the two-way audio.
Call Master Station from Device:
1. Add both the master station and the device to the client software.
2. Set the master station’s IP and SIP address in the device’s remote configuration page.
3. Tap the call button on the device. The device will call the master station in priority.
4. Answer the call on the master station to start two-way audio.
Call Device from Client Software:
1. Add the device to the client software.
2. Enter the Live View page and double-click the added device to start live view.
3. Right-click the live view image and select Start Two-Way Audio.
Call Indoor Station from Device:
1. Add the indoor station and the device to the client software.
2. Link a user to an indoor station and set a room No. for it.
3. Tap the call icon on the device’s authentication page.
4. Input the room No. on the dial page and tap the call button.
5. When the indoor station answers, you can start two-way audio.
What are the tips for scanning a fingerprint correctly on the HIKVISION DS-K1T607TMF?
To ensure successful fingerprint scanning, please follow these tips:
Recommended Finger:
Use your forefinger, middle finger, or third finger.
Correct Scanning:
Press your finger on the scanner horizontally. The center of your scanned finger should align with the scanner’s center. Avoid placing your finger vertically, on the edge, or sideways on the scanner.
Environment:
The scanner should avoid direct sunlight, high temperature, humid conditions, and rain. If your finger is too dry, the scanner may not recognize it successfully. You can try blowing on your finger and scanning again.
Others:
If your fingerprint is shallow or hard to scan, it is recommended to use other authentication methods. If you have injuries on the scanned finger, the scanner may not recognize it. In this case, change to another finger and try again.
What are the best practices for collecting and comparing a face picture with the HIKVISION DS-K1T607TMF?
To get a good quality and accurate face picture for recognition, follow these recommendations:
Position (Recommended Distance: 0.5 m):
Stand at a recommended height of 1.4 m to 1.9 m. Avoid being too high, too low, too close, or too far from the camera.
Expression:
Keep your expression natural, similar to a passport photo. Do not wear a hat, sunglasses, or other accessories that can affect facial recognition. Ensure your hair does not cover your eyes or ears. Heavy makeup is not allowed.
Posture:
Position your face looking directly at the camera. Avoid tilting your head up, down, or to the side.
Size:
Make sure your face is in the middle of the collecting window. It should not be too close or too far.
What are the installation environment requirements for the HIKVISION DS-K1T607TMF?
1. Light Source Illumination Reference Value:
• Candle: 10 Lux
• Bulb: 100~850 Lux
• Sunlight: More than 1200 Lux
2. Placement:
Install the device at least 2 meters away from any light source and at least 3 meters away from a window or door.
3. Avoid Direct Light:
Avoid backlight, direct sunlight, indirect sunlight through a window, and being too close to a light source.
What is the relationship between wake-up distance and the environment for the HIKVISION DS-K1T607TMF?
The wake-up distance of the HIKVISION DS-K1T607TMF varies depending on the environment, lighting conditions, and the target (e.g., a wall, a person). The following table provides estimated distances for Short, Medium, and Long wake-up settings.
| Environment | Short | Medium | Long | |
|---|---|---|---|---|
| At Dusk (Low Illumination) | Normal White Wall | 1.06 m | 1.67 m | 3.62 m |
| Acrylic Wall in Laboratory | 0.85/0.73 m | 1.30/1.21 m | 4.16 m | |
| Human Body | 0.74 m | 0.94 m | 1.50/1.45 m | |
| Window Glass | / | / | / | |
| At Night (Turn Light Off) | Normal White Wall | 0.97 m | 1.61 m | 3.91 m |
| Acrylic Wall in Laboratory | 0.79 m | 1.32 m | 3.67 m | |
| Human Body | 0.47 m | 1.03 m | 1.65 m | |
| Window Glass | 1.18/1.65 m (Turn on Light at Night) | 1.53/2.66 m (Turn on Light at Night) | 3.35 m | |
| Daytime (Turn Fluorescent Lamp on) | Normal White Wall | 1.1 m | 1.8 m | > 4 m |
| Acrylic Wall in Laboratory | 0.8 m | 1.5 m | 3.1 m | |
| Human Body | 0.7/0.6 m | 1.2/1.14 m | 1.5/1.42 m | |
| Window Glass | 1.1 m | 1.8 m | > 4 m | |
| Daytime (Turn Camera to Sunlight) | Human Body | 0.3/0.26 m | 0.56/0.5 m | 1.03/1.06 m |
| Daytime (Turn device’s back to Sunlight) | Human Body | 0.36 m | 0.6 m | 1.25 m |
| At Night (Turn Light on) | Acrylic Black Wall | 0.56 m | 0.83 m | 1.25 m |
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD HIKVISION DS-K1T607TMF (01) PDF DOCUMENT