Free English EXTRON TOUCHLINK TLP PRO 725T (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD EXTRON TOUCHLINK TLP PRO 725T (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

What are the general features of the EXTRON TOUCHLINK TLP PRO 725T?

The EXTRON TOUCHLINK TLP PRO 725T includes the following features:

• LCD touchscreen: A 7-inch touchscreen with 1024×600 (WSVGA) resolution, 24-bit color depth, and a vibrant edge-to-edge glass display.

• Gorilla® Glass screen: The screen is tough, scratch, and smudge-resistant, maintaining touch sensitivity, color saturation, and brightness.

• Faster, quad-core processing: Provides enhanced response and overall user experience.

• Power over Ethernet (PoE 802.3af, class 3) compliance: Allows the touchpanel to receive power and communication over a single Ethernet cable, eliminating the need for a local power supply (power injector sold separately).

• Optional Mounting Kits: The tabletop model features a fixed 65-degree viewing angle, threaded holes in the baseplate for secure mounting, and can be used with the optional SMA-2 Swivel Mount Adapter.

• Remote Management: Can be managed, monitored, and controlled remotely using GVE GlobalViewer Enterprise Resource Management software.

• Built-in speaker: Provides audible feedback from button presses.

• Light sensor: Adjusts screen brightness as the ambient room lighting changes.

• Automatic clock synchronization: Allows the touchpanel to display the accurate time and date.

• Energy-saving features: Includes an adjustable sleep timer to put the touchpanel into sleep mode and a motion detector to wake the touchpanel.

• High speed USB 2.0 port: Available for future expansion.


What is the initial installation overview for the EXTRON TOUCHLINK TLP PRO 725T?

Follow this overview for the installation process of your EXTRON TOUCHLINK TLP PRO 725T:

1. Before starting, download and install the latest versions of the required software:

• GUI Designer: For designing layouts for the touchpanel.

• Global Configurator Plus and Professional: For setting up and configuring the control processor and touchpanel.

• ControlScript Deployment Utility: Provides integrated development environments for Extron control systems programming.

• Toolbelt: Provides device discovery, firmware updates, and configuration of network settings, system utilities, and user management.

2. Obtain the following network information from your network administrator:

• Dynamic Host Configuration Protocol (DHCP) status (on or off). If DHCP is off, you also require an IP address, Subnet mask, and Gateway.

• User name (admin or user).

• Password (factory default is the device serial number).

• MAC address (found on a label on the base).

• SSL security certificates and IEEE 802.1X authentication information if applicable.

3. Mount and cable the unit.

4. Set up the touchpanel for network communication by connecting your PC, control processor, and the touchpanel to the same Ethernet subnetwork. Use the On-screen Menus or Toolbelt to set the network settings.

5. Configure or program the Touchpanel using the appropriate software tools like GUI Designer and Global Configurator.


How do I connect power to my EXTRON TOUCHLINK TLP PRO 725T?

The EXTRON TOUCHLINK TLP PRO 725T must be powered by Power over Ethernet (PoE). You must provide your own PoE power injector or use a PoE switch. To use a power injector:

1. Connect a straight-through Ethernet cable from the power injector’s LAN port to a network switch or router. This cable carries network information.

2. Connect a second straight-through Ethernet cable from the power injector’s LAN+PWR OUT port to the touchpanel. This cable carries both network information and 48 VDC power.

3. Connect the IEC power cord from the power injector to a convenient 100 VAC to 240 VAC, 50-60 Hz power source.

Alternatively, you can connect the touchpanel directly to a PoE switch.


What are the front panel features of the EXTRON TOUCHLINK TLP PRO 725T?

• LCD touchscreen: A 7-inch, tough, scratch-resistant touchscreen with 1024×600 (WSVGA) resolution.

• Motion sensor (two): The sensor detects motion between 3 to 5 feet (0.9 to 1.5 meters) from the touchpanel, and at least 15° from the center axis. When Sleep Mode and Wake on Motion are enabled, the touchpanel will enter sleep mode after a period of no motion and will wake up when motion is detected.

• Communication LED: Shows the configuration and connection status. It is unlit during normal operation (configured and connected), blinks if configured but not connected, and lights steadily if not configured.

• Light sensor: Monitors ambient light level and adjusts screen brightness based on the configured settings.

• Front status light: A single LED in the center of the bottom edge. The light can blink or remain lit steadily in red or green. It can be configured to provide feedback information about the system status.


What are the functions of the buttons and connectors on the base of the EXTRON TOUCHLINK TLP PRO 725T?

The base of the EXTRON TOUCHLINK TLP PRO 725T includes the following:

• MENU button: Activates the On-screen Menus.

• RESET button: Allows the unit to be reset in three different modes and can be used to toggle the DHCP client.

• Cable guide: An opening at the back of the base through which the Ethernet cable is inserted.

• RESET LED: Provides feedback about the reset status when the RESET button is pressed.

• LAN/PoE connector: This is where you connect the Ethernet cable for network connectivity and Power over Ethernet (PoE).

• Speaker: A single speaker provides audible feedback for the user.

• USB port: Compatible with USB 2.0. A plastic cover must be removed for access.

• Rear status light: A single LED at the top center of the rear panel that can be configured to provide system feedback.


How do I access and navigate the on-screen setup menu on the EXTRON TOUCHLINK TLP PRO 725T?

To open the setup menu, use a screwdriver with a fine blade to press the MENU button located on the base of the EXTRON TOUCHLINK TLP PRO 725T.

The menu opens at the Status screen. There are several different panels you can access:

• Status

• LinkLicenses

• System Information

• Network

• Display

• Audio

• Advanced

You can select the Status, Network, Display, Audio, and Advanced screens by pressing the appropriate button in the navigation panel at the top of the screen. The selected button will be yellow. LinkLicenses and System Information are accessible only from the Status screen.

Press the red Exit button in the top right corner to apply and save any changes and close the menu.


How do I configure network settings on the EXTRON TOUCHLINK TLP PRO 725T using the on-screen menu?

1. Access the on-screen menu by pressing the MENU button on the base.

2. Press the Network button in the navigation panel at the top of the screen.

3. Select the Max Ethernet Speed (100Mbps or 1.0Gbps).

4. If IP addresses are assigned by DHCP, press On. If IP addresses are assigned manually, press Off.

• When DHCP is On, the Host Name can be edited, but the other address fields are grayed out as they are set by the DHCP server.

• When DHCP is Off, the Host Name is grayed out, but you can edit the IP Address, Subnet Mask, Gateway, and DNS Primary addresses.

5. To edit a field, press the corresponding button. An alphanumeric keypad will appear for the Host Name, and a numeric keypad will appear for addresses.

6. Enter the new information and press Save or OK.

7. If you have made changes, the Apply and Revert buttons become active. Press Apply to save the new values or Revert to cancel the changes.


How do I configure the display settings on my EXTRON TOUCHLINK TLP PRO 725T?

1. Access the on-screen menu by pressing the MENU button.

2. Press the Display button in the top navigation panel.

3. Configure the following settings:

Sleep Timer: Toggle between On and Off. When On, the screen goes dark after a period of inactivity to save power. Use the up and down arrows to set the inactivity period from 1 to 120 minutes.

Auto Brightness: Toggle between On and Off. When On, the light sensor automatically adjusts screen backlighting. When Off, brightness is not affected by ambient light.

LCD Brightness: Use the slider control to manually adjust the screen brightness between 0 and 100.

Wake on Motion: Toggle between On and Off. For this to work, the touchpanel must be in sleep mode. When On, motion detected by the motion sensor wakes the panel. When Off, you must press the screen to wake the panel.


How do I adjust the audio settings on the EXTRON TOUCHLINK TLP PRO 725T?

1. Access the on-screen menu by pressing the MENU button.

2. Press the Audio button in the top navigation panel.

3. Use the slider controls to adjust the following volume settings:

System: Sets the maximum volume for all other sound settings. For example, if System volume is set to 80 (80%), when the Sound volume is set to 90, it is equivalent to 90% of 80, which is 72% of maximum.

Click: Sets the volume for audible feedback from events like a screen button being pressed.

Sound: Sets the volume of audio from any audio file playback.

4. Click on the Speaker icon at the bottom of each panel to toggle between audio on and audio mute.


How do I set up a Menu PIN on the EXTRON TOUCHLINK TLP PRO 725T?

The Menu PIN is a 4-digit number that secures access to the setup menu.

1. Access the on-screen menu and press the Advanced button.

2. In the Menu PIN section, click On to enable the use of a PIN or Change to edit an existing PIN. This opens the PIN dialog.

3. On the numeric keypad, press a number. A blue circle appears in the first of four boxes.

4. Select the other three digits for the PIN. After the fourth digit is entered, the screen changes to “Confirm New Menu Pin”.

5. Enter the PIN a second time. If the PINs match, the PIN is set, and the dialog closes.

To disable the PIN, click Off in the Menu PIN section.


How do I update the firmware on my EXTRON TOUCHLINK TLP PRO 725T?

Firmware can be upgraded using the Toolbelt software. Before starting, ensure the touchpanel has a unique IP address and is connected to the same network as your computer.

1. On the Extron home page, select the Downloads tab and then click Firmware.

2. Start typing the product name (TLP Pro x25 Series) in the Search Firmware text box. The name will appear in a drop-down list.

3. Click the Firmware name from the list.

4. Click the Download button next to the latest firmware version.

5. Enter the required information and click the download button.

6. Go to your Downloads folder and click the file to install the firmware on your PC. By default, it is stored at C:\\Program Files (x86)\Extron\Firmware\\\\.

7. Open the Toolbelt software and upload this file to the touchpanel. For detailed instructions on using Toolbelt, refer to the Toolbelt Help File.


How do I mount the EXTRON TOUCHLINK TLP PRO 725T to a desk or table?

The EXTRON TOUCHLINK TLP PRO 725T can be placed on any suitable flat surface. For additional security, you can secure it to a table or desk with screws:

1. Under the table top, mark the location for two mounting holes, 2.71 inches (69 mm) apart.

2. Drill two holes through the table top from underneath.

3. Attach the touchpanel using two #6-32 machine screws through the table top from underneath into the two holes in the base of the touchpanel.

The touchpanel can also be mounted with the optional Extron SMA-2 swivel mount adapter, which must be purchased separately and installed following the instructions provided with the kit.


How do I apply a LinkLicense to my EXTRON TOUCHLINK TLP PRO 725T?

A LinkLicense activation file can be applied to the touchpanel using the Toolbelt software.

1. Open Toolbelt.

2. Connect the touchpanel.

3. Open the LinkLicense tab.

4. Press the … menu button.

5. Find the LinkLicense activation file on your computer.

6. Click Apply.

The LinkLicense is then applied to the touchpanel.


What are the best practices for cleaning the EXTRON TOUCHLINK TLP PRO 725T?

All Extron products can be safely cleaned with:

• 70% concentration or higher isopropyl alcohol

• Disinfectant cleaners that are non-ammonium based and contain 2% or less sodium hypochlorite (e.g., 2% bleach, 98% water).

Follow these general guidelines when cleaning:

1. If possible, unplug the device.

2. Spray the cleaner on a lint-free cloth until the cloth is damp.

3. Do not spray the cleaner directly onto the product.

4. Gently clean the product surface using the cloth.


How do I use the “Use Factory Firmware” reset mode on the EXTRON TOUCHLINK TLP PRO 725T?

This mode boots the unit with factory-installed firmware for a single power cycle, which is useful if a firmware update fails.

Activation:

1. Remove power from the touchpanel.

2. On the touchpanel base, hold down the recessed RESET button while re-applying power to the unit. When power is restored, the Reset LED lights.

3. Continue to hold the RESET button for a further 2 seconds before releasing it. The touchpanel enters factory firmware mode.

4. You can now upload new firmware to the unit as desired.

Result:

The unit reverts to factory-installed firmware for this session. All user files and settings are maintained. To return the unit to the firmware version that was running prior to the reset, simply cycle power to the unit.


How do I perform a “Reset Network Settings” on the EXTRON TOUCHLINK TLP PRO 725T?

This mode resets all IP settings to factory defaults.

Activation:

1. Hold down the RESET button for about 6 seconds until the Reset LED blinks twice (once at 3 seconds and again at 6 seconds).

2. Release and press the RESET button momentarily (for less than 1 second) within 1 second of releasing it.

Result:

• The IP address is set back to the factory default (192.168.254.251).

• The subnet is set back to the factory default (255.255.255.0).

• The default gateway address is set to the factory default (0.0.0.0).

• All other IP settings, addresses, and domain/host names are reset to factory default.

• DHCP is turned off.


How do I perform a “Full Factory Reset” on the EXTRON TOUCHLINK TLP PRO 725T?

This mode resets all IP settings and touchpanel settings, including passwords, to factory defaults and removes all configurations. It allows you to start over with configuration and uploading.

Activation:

1. Hold down the RESET button for about 9 seconds until the Reset LED blinks three times (at 3, 6, and 9 seconds).

2. Release and press the RESET button momentarily (for less than 1 second) within 1 second of releasing it.

Result:

• It performs all actions of the “Reset Network Settings” mode.

• It removes the touchpanel user interface layout and configurations.

• It resets all touchpanel settings to factory default.

• The password is reset to the default configuration, which is “extron” for both admin and user accounts.


How do I toggle the DHCP client on the EXTRON TOUCHLINK TLP PRO 725T using the RESET button?

This mode toggles between DHCP enabled and DHCP disabled.

Activation:

1. Press the RESET button five times consecutively.

2. Release the button. Do not press the button again within 3 seconds following the fifth press.

Result:

• If DHCP was enabled, it is now disabled. The Reset LED blinks three times.

• If DHCP was disabled, it is now enabled. The Reset LED blinks six times.

By default, DHCP is off and the unit uses a static IP address. When you disable DHCP, the unit reverts to using the previously-set static IP address.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD EXTRON TOUCHLINK TLP PRO 725T (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.