What are the general features of the EXTRON TOUCHLINK TLP PRO 1025M?
The EXTRON TOUCHLINK TLP PRO 1025M includes the following features across all models in its series:
• LCD touchscreen: A 10.1-inch touchscreen with 1280×800 (WXGA) resolution, 24-bit color depth, and a vibrant edge-to-edge glass display.
• Gorilla® Glass screen: The screen is tough, scratch, and smudge-resistant, offering greater strength and scratch resistance than standard glass while maintaining touch sensitivity, color saturation, and brightness.
• Faster, quad-core processing: Provides enhanced response and overall user experience.
• Power over Ethernet (PoE 802.3af, class 3) compliance: Allows the touchpanel to receive power and communication over a single Ethernet cable, eliminating the need for a local power supply (power injector sold separately).
• Optional Mounting Kits available: Various kits are available for mounting in a two-gang junction box or on a wall, lectern, or any flat surface, including glass.
• Remote Management: Can be managed, monitored, and controlled remotely using GVE GlobalViewer Enterprise Resource Management software.
• Built-in speaker: Provides audible feedback from button presses.
• Light sensor: Adjusts screen brightness based on ambient room lighting conditions.
• Automatic clock synchronization: Allows the touchpanel to display the accurate time and date.
• Energy-saving features:
– An adjustable sleep timer puts the touchpanel into sleep mode.
– A motion detector wakes the touchpanel.
• High speed USB 2.0 port: Available for future expansion.
What specific features are part of the TLP Pro series for the EXTRON TOUCHLINK TLP PRO 1025M?
The TLP Pro series, which includes the EXTRON TOUCHLINK TLP PRO 1025M, has the following specific features:
• Compatibility with Extron Control Processors: Works with the full range of Extron IPL Pro and IPCP Pro control processors for easy integration into existing systems.
• LinkLicense for TLP Control Processor: Can be transformed into an all-in-one Pro xi Series control system with the appropriate LinkLicense and TLCA 1 TouchLink Control Port Expansion Adapter.
• System connection status indicator: A communication LED provides visual feedback on the connection status with a control processor.
• Fully customizable using Extron control system software: The user interface is designed with GUI Designer and can be configured with Global Configurator Plus, Global Configurator Professional, or ControlScript Deployment Utility.
• Extron Control App Support: Supports the Extron Control App and Extron Control for Web.
• Digital input: Allows connections to various devices such as sensors and switches.
What is the installation overview for the EXTRON TOUCHLINK TLP PRO 1025M?
Follow this overview for the installation process of your EXTRON TOUCHLINK TLP PRO 1025M.
1. Download and Install Software: Before starting, download and install the latest versions of the required software:
• GUI Designer: For designing layouts for the touchpanel.
• Global Configurator Plus and Professional: For setting up and configuring the control processor and touchpanel.
• ControlScript Deployment Utility: Provides an integrated development environment for programming Extron control systems.
• Toolbelt: Provides device discovery, firmware updates, and configuration of network settings.
2. Obtain Network Information: Get the following information from your network administrator:
• Dynamic Host Configuration Protocol (DHCP) status: If DHCP is off, you will also need an IP address, Subnet mask, and Gateway.
• User name: This can be either admin or user.
• Password: The factory configured password is the device serial number. The default password after a reset is “extron”.
• MAC address: Make a note of the MAC address from the rear panel label.
3. Mount and Cable the Unit: Mount the touchpanel in its desired location. Do not power on the unit until you have reviewed the Power over Ethernet (PoE) power supply information. Connect the necessary cables to the touchpanel. Once cabled, connect the power cords and power on all devices.
4. Set up Network Communication: Connect your PC, the Extron control processor, and the touchpanel to the same Ethernet subnetwork. Use the On-screen Menus or Toolbelt to set the DHCP status and, if needed, the IP address, subnet mask, gateway, and related settings.
5. Configure or Program the Touchpanel: Use the GUI Designer Help File, the Global Configurator Plus and Professional Help File, and the ControlScript Deployment Utility Help File for step-by-step instructions on configuring the touchpanel’s interface and functions.
What are the features on the front panel of the EXTRON TOUCHLINK TLP PRO 1025M?
The front panel of the EXTRON TOUCHLINK TLP PRO 1025M includes:
• LCD touchscreen: A 10.1-inch touchscreen with 1280×800 (WXGA) resolution, made with tough, scratch-resistant glass.
• Motion sensor (two): Detects motion between 3 to 5 feet (0.9 to 1.5 meters) from the touchpanel, at least 15° from the center axis. When Sleep Mode and Wake on Motion are enabled, the touchpanel will enter sleep mode after a period of no motion and will wake up when motion is detected.
• Communication LED: Shows the configuration and connection status. It is unlit during normal operation, blinks if configured but not connected to a processor, and lights steadily if not configured. This can be enabled/disabled in the On-screen Menus.
• Light sensor: Monitors ambient light and adjusts screen brightness accordingly if Auto Brightness is enabled.
• Front status light (two): Two LEDs (one on each side) that can be configured to blink or remain lit, in red or green, to provide system feedback.
What are the functions of the buttons and ports on the rear panel of the EXTRON TOUCHLINK TLP PRO 1025M?
The rear panel of the EXTRON TOUCHLINK TLP PRO 1025M includes the following:
• MENU button: Activates the On-screen Menus for configuration.
• RESET button: Allows the unit to be reset in several different modes, and can also be used to toggle the DHCP client.
• Reset LED: Provides feedback about the reset status when the RESET button is pressed.
• Mounting slots (four): One in each corner for securing the touchpanel to a mounting plate.
• Digital input monitoring port: A two-pole captive screw port (1=signal, G=ground) that monitors digital input with or without a +5 VDC pull-up. The port’s logic states are as follows:
Digital Input, Pullup Disabled
| Logic State | Notes |
|---|---|
| Logic Low | Voltage below 2.0 VDC |
| Logic High | Voltage above 2.8 VDC |
Digital Input, Pullup Enabled
| Logic State | Notes |
|---|---|
| Logic Low | Externally shorted to ground |
| Logic High | Open, +5V from pull-up resistor |
• LAN/PoE connector: For network connection and power via Power over Ethernet (PoE).
• USB port: Compatible with USB 2.0 for future expansion.
• Speaker: The TLP Pro 1025M has two speakers (dual mono) for audible feedback.
• Slot for mounting plate: The tongue at the bottom of the mounting plate fits into this slot for wall mounting.
• Mounting screw: Tightens against the tongue of the mounting plate to secure the touchpanel.
• Rear status light: The TLP Pro 1025M has a single LED strip on each side of the rear panel that can be configured to provide system feedback.
How do I connect power to my EXTRON TOUCHLINK TLP PRO 1025M?
The EXTRON TOUCHLINK TLP PRO 1025M must be powered by Power over Ethernet (PoE). You must provide your own PoE power injector or use a PoE-enabled network switch.
To use a PoE injector:
1. Connect a straight-through Ethernet cable from the power injector’s “LAN” port to your network switch or router. This cable carries network information.
2. Connect a second straight-through Ethernet cable from the power injector’s “LAN + PWR OUT” (or similarly labeled) port to the LAN/PoE port on the touchpanel. This cable carries both network information and 48 VDC power.
3. Connect the IEC power cord of the power injector to a convenient 100 VAC to 240 VAC, 50-60 Hz power source.
Alternatively, you can connect the touchpanel directly to a port on a PoE switch.
How do I access and navigate the on-screen menus of the EXTRON TOUCHLINK TLP PRO 1025M?
To access the setup menu for initial configuration, use a small screwdriver with a fine blade to press the MENU button located on the rear panel of the EXTRON TOUCHLINK TLP PRO 1025M.
The menus open to the Status screen. There are several panels you can navigate to using the buttons at the top of the screen:
• Status: Provides a read-only summary of the touchpanel’s basic information.
• Network: Configure IP address, DHCP, and other network settings.
• Display: Adjust sleep timer, brightness, and motion sensor settings.
• Audio: Control system, click, and sound volumes.
• Advanced: View project information and configure certain hardware features.
The selected panel’s button is yellow, while the others are black. From the Status screen, you can also access the LinkLicenses and System Information panels.
To save any changes and close the menu screens, press the red Exit button in the top right corner.
How do I enable or disable a LinkLicense on my EXTRON TOUCHLINK TLP PRO 1025M?
You can enable or disable a LinkLicense from the Status screen in the on-screen menus. A LinkLicense must first be applied to the touchpanel for the toggle switch to be active.
To Enable LinkLicense:
1. From the Status screen, locate the LinkLicenses pane.
2. Move the toggle switch to the right (on position). An “Enable LinkLicenses” dialog box will open, warning you that all user-loaded project files will be removed.
3. Click Enable LinkLicenses. The touchpanel will reboot with the LinkLicense enabled, functioning as a control processor.
To Disable LinkLicense:
1. From the Status screen, move the toggle switch in the LinkLicenses pane to the left (off position). A “Disable LinkLicenses” dialog box opens.
2. Click Disable LinkLicenses. The touchpanel will reboot with the LinkLicense disabled.
NOTE: Enabling or disabling a LinkLicense will remove all projects from the touchpanel, and they will need to be reloaded.
How do I pair my EXTRON TOUCHLINK TLP PRO 1025M with a control processor?
Pairing connects the touchpanel to a primary control processor. This is done from the System Information section of the Status tab in the on-screen menus. This process does not apply if the touchpanel is in LinkLicense mode, as it acts as its own controller.
1. On the Status page, in the System Information panel, click Edit. The System ID dialog box opens.
2. Enter the Primary Controller Address (the IP address of the control processor).
3. Enter the System ID. This is a four-digit number generated by ControlScript Deployment Utility or Global Configurator Plus/Professional that is needed to link the touchpanel to the control processor.
4. Click Save.
The dialog box closes, and the Primary Controller Address and System ID are now displayed in the System Information pane, indicating a successful pairing.
How do I configure network settings on the EXTRON TOUCHLINK TLP PRO 1025M?
You can configure network settings from the Network screen in the on-screen menus. Verify with your network administrator whether the IP address should be assigned by DHCP or set manually.
1. Press the Network button at the top of the screen.
2. Select the Max Ethernet Speed (100Mbps or 1.0Gbps).
3. DHCP Configuration:
• If IP addresses are assigned by DHCP, press On. The IP address fields will be grayed out as they are set by the DHCP server. You can edit the Host Name.
• If IP addresses are assigned manually, press Off. The Host Name will be grayed out. You can now edit the IP Address, Subnet Mask, Gateway, and DNS Primary fields.
4. Manual IP Address Entry (if DHCP is Off):
• Press the button for the address you wish to edit (e.g., IP Address).
• A numeric keypad will appear. Select an octet and enter the 3-digit value (0-255).
• Press OK to save the changes for that address and return to the Network screen.
5. After making changes, the Apply and Revert buttons become active. Press Apply to save all new network settings or Revert to discard them. Once applied, the buttons will gray out.
How do I configure the display settings for my EXTRON TOUCHLINK TLP PRO 1025M?
Display settings can be adjusted from the Display screen in the on-screen menus.
• Sleep Timer: Toggle between On and Off. When On, the screen goes dark (Sleep mode) after a period of inactivity to save power. Use the up and down arrows to set the inactivity period from 1 to 120 minutes. If Off, the panel does not enter sleep mode.
• Auto Brightness: Toggle between On and Off. When On, the light sensor monitors ambient light and automatically adjusts the screen’s backlighting. When Off, the screen brightness is not affected by changes in ambient light.
• LCD Brightness: Use the slider control to manually adjust the screen brightness on a scale from 0 to 100.
• Wake on Motion: Toggle between On and Off. For this to work, the touchpanel must be in sleep mode. When On, any motion detected by the motion sensor will wake the panel. When Off, the panel does not wake in response to motion; it must be woken by touching the screen.
How can I adjust the audio settings on the EXTRON TOUCHLINK TLP PRO 1025M?
Audio settings are managed on the Audio screen in the on-screen menus. Use the slider controls to adjust the volume for each category.
• System: Sets the maximum volume for all other sound settings. For example, if System volume is at 80, a Sound volume set to 90 will be 90% of 80, which is 72% of the absolute maximum.
• Click: Sets the volume for the audible feedback you hear when a screen button is pressed.
• Sound: Sets the volume of audio from any audio file playback.
• Speaker icon: Click the speaker icon at the bottom of each panel to toggle the audio between on and mute for that specific category.
How do I set up a PIN for the on-screen menu on my EXTRON TOUCHLINK TLP PRO 1025M?
You can enable, disable, or change the setup menu PIN from the Advanced screen. The PIN is a 4-digit number, with each digit ranging from 0-9.
1. In the Menu PIN section of the Advanced screen, choose an option:
• Click On to enable the use of a PIN.
• Click Off to disable the use of a PIN.
• Click Change to edit an existing PIN.
2. If you are setting a new PIN or changing an existing one, a numeric keypad dialog opens for “Enter New Menu PIN”.
3. Press four numbers on the keypad to enter your desired PIN. As you enter them, blue circles will appear in the boxes at the top.
4. After the fourth digit is entered, the screen changes to “Confirm New Menu Pin”.
5. Enter the same 4-digit PIN a second time. If it matches the first entry, the PIN is set, and the dialog closes.
How do I update the firmware on my EXTRON TOUCHLINK TLP PRO 1025M?
Firmware can be upgraded using the Extron Toolbelt software. Before you begin, ensure the touchpanel has a unique IP address and is connected to the same network as your computer.
1. From the Extron home page, select the Downloads tab, then click Firmware.
2. In the Search Firmware text box, start typing the product name (“TLP Pro x25 Series”). The name will appear in a drop-down list.
3. Click the firmware name. Information about the latest firmware version will be displayed.
4. Click the Download button for the active version.
5. Enter any required information and click the download button to save the file to your computer.
6. Go to your Downloads folder and run the file to install the firmware on your PC. By default, it is stored at `C:\\Program Files (x86)\Extron\Firmware\<product name>\<firmware version>`.
7. Open the Extron Toolbelt software and use it to upload this newly installed firmware file to your touchpanel. For specific instructions on using Toolbelt for firmware updates, refer to the Toolbelt Help File.
How do I mount the EXTRON TOUCHLINK TLP PRO 1025M to a wall box or junction box?
The EXTRON TOUCHLINK TLP PRO 1025M mounts to a 2-gang junction box.
1. Install a 2-gang junction box or wall box according to the manufacturer’s instructions.
2. Fasten the correct mounting plate to the wall box using the provided screws. Use the mounting holes on the plate that are appropriate for your type of junction box (US, MK, or EU).
3. Run and connect the necessary cables to the back of the touchpanel.
4. Position the touchpanel so that the four mounting slots on its rear align with the four hooks on the mounting plate.
5. Move the touchpanel inwards so that the slots move over the hooks.
6. Move the touchpanel down so it is seated securely on the hooks and the tongue at the bottom of the mounting plate is sitting in the corresponding groove in the bottom of the touchpanel.
7. Tighten the mounting screw on the bottom of the touchpanel to fasten it securely to the mounting plate.
What are the best practices for cleaning my EXTRON TOUCHLINK TLP PRO 1025M?
To safely clean your EXTRON TOUCHLINK TLP PRO 1025M, especially the touchscreen, follow these guidelines. All Extron products can be safely cleaned with:
• 70% concentration or higher isopropyl alcohol
• Disinfectant cleaners that are non-ammonium based and contain 2% or less sodium hypochlorite (2% bleach, 98% water).
Follow these general steps when cleaning:
1. If possible, unplug the device.
2. Spray the cleaner on a lint-free cloth until the cloth is damp.
3. Do not spray the cleaner directly onto the product itself.
4. Gently clean the product surface using the damp cloth.
How can I reset my EXTRON TOUCHLINK TLP PRO 1025M?
The EXTRON TOUCHLINK TLP PRO 1025M has three reset modes initiated by pressing the recessed RESET button on the rear panel.
Use Factory Firmware
This mode boots the unit with its factory-installed firmware for a single power cycle, which is useful if a firmware update fails.
1. Remove power from the touchpanel.
2. Press and hold the RESET button while re-applying power. The Reset LED will light up.
3. Continue holding the RESET button for 2 more seconds, then release it. The touchpanel enters factory firmware mode. You can now upload new firmware.
Reset Network Settings
This mode resets all IP settings to factory defaults.
1. Hold down the RESET button for about 6 seconds until the Reset LED blinks twice (once at 3 seconds, again at 6 seconds).
2. Within 1 second, release and momentarily press the RESET button again (for less than 1 second). This resets the IP address to 192.168.254.251, subnet to 255.255.255.0, gateway to 0.0.0.0, and turns DHCP off.
Full Factory Reset
This mode resets all IP and touchpanel settings (including passwords) to factory defaults and removes all configurations, except for the firmware.
1. Hold down the RESET button for about 9 seconds until the Reset LED blinks three times (at 3, 6, and 9 seconds).
2. Within 1 second, release and momentarily press the RESET button again. The unit will be reset to its original factory state.
How do I toggle the DHCP client on my EXTRON TOUCHLINK TLP PRO 1025M using the RESET button?
You can toggle the DHCP client between enabled and disabled using the RESET button. This feature is supported on firmware version 3.0 or higher.
1. Press the RESET button five times consecutively.
2. Release the button. Do not press the button again within 3 seconds following the fifth press.
• If DHCP was enabled, it is now disabled. The Reset LED blinks three times. The unit reverts to its previously-set static IP address.
• If DHCP was disabled, it is now enabled. The Reset LED blinks six times.
What are the file requirements for an IEEE 802.1X security certificate for the EXTRON TOUCHLINK TLP PRO 1025M?
To create an 802.1X security certificate for uploading to the EXTRON TOUCHLINK TLP PRO 1025M, ensure the certificate file meets the following requirements:
• It must contain X.509 certificate information.
• It must contain a private key (for machine certificates only).
• It must be PEM encoded. DER encoded files (with .der, .crt, or .cer extensions) must be converted to PEM format before use.
• It must have a file extension of .crt or .pem.
• Its file name must consist only of the following valid characters:
– Alphanumerical (A-Z, a-z, 0-9)
– Special characters: colon [:], underscore [_], and hyphen [-]
• Spaces are not permitted anywhere in the file name.
What are the file requirements for a private key file used with the EXTRON TOUCHLINK TLP PRO 1025M?
Private key files are required only when using machine certificates for 802.1X authentication. When creating a private key for the EXTRON TOUCHLINK TLP PRO 1025M, follow these requirements:
• Its file name consists of the following types of valid characters:
– Alphanumerical (A-Z, a-z, 0-9)
– Some special characters (colon [:], underscore [_], and hyphen [-])
• It has a file extension that is .key or .pem.
• It can have optional encryption (via password or passphrase).
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD EXTRON TOUCHLINK TLP PRO 1025M (01) PDF DOCUMENT