How do I set up the blockage monitoring for my JOHN DEERE SEEDSTAR 2?
To set up blockage monitoring, select the primary Menu button, then the Blockage button, then the Blockage Configuration softkey, and finally the Row Fail Rate drop down menu. Verify your machine configuration is accurate. A check next to Top or Bottom Shoot indicates an active system. Select the setup Wizard button. Verify the Primary or All Run blockage configuration. Advance through the screen pages to verify the blockage configuration matches your tool components. Select a level of sensor response, which sets the amount of time allowed between seed detections before blockage or undesired seed flow is indicated. Once the seed rate is verified in the field, set the level as sensitive as possible without triggering nuisance alerts.
What do the sensor indicators mean on the JOHN DEERE SEEDSTAR 2?
The sensor indicators for the JOHN DEERE SEEDSTAR 2 are as follows: Green indicates product flow and an active sensor. White indicates an inactive sensor. Red indicates a blocked hose. X indicates a deactivated sensor.
How does the row fail rate feature work on the JOHN DEERE SEEDSTAR 2?
The JOHN DEERE SEEDSTAR 2 row fail rate functions differently based on whether meter sections are commanded ON or OFF. Please see the table below:
| When meter sections are commanded ON | When meter sections are commanded OFF |
|---|---|
| If product flow is below selected level, blockage is indicated. (Blockage warning, or blockage run screen indicator will change to Red.) | If product flow is above selected level, undesired seed flow is indicated. (Undesired seed flow warning, or blockage run screen indicator will change to Green.) |
What do the tower designations mean on the JOHN DEERE SEEDSTAR 2?
A tower designator followed by a series of numbered boxes indicates an all run system for the JOHN DEERE SEEDSTAR 2, where the numbers coincide with secondaries. A stand alone box indicates a primary only system.
What are the functions of the buttons on the JOHN DEERE SEEDSTAR 2 display?
The following buttons perform specific tasks on the JOHN DEERE SEEDSTAR 2:
Blockage – Main: Select for the main blockage run page.
Blockage – Setup: Select to define the tool and blockage configuration.
Diagnostics: Select to enter diagnostic information.
Operator Alert Setup: Used to set the Blockage Warning.