Free English JOHN DEERE SEEDSTAR N500C (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD JOHN DEERE SEEDSTAR N500C (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
How do I add new run pages on the JOHN DEERE SEEDSTAR N500C?
To add run pages, follow these steps:
1. Select Menu.
2. Select the Applications tab.
3. Select the Layout Manager application.
4. Select the Active Set tab or All Run Pages tab.
5. Select a run page to edit or select Add New.
How do I add a module to a run page on the JOHN DEERE SEEDSTAR N500C?
To add a module, follow these steps:
1. Select the All Run Pages tab.
2. Select Add New.
3. Select Add Module.
4. Choose an application to see the associated modules available.
5. Save the edited or new run page. Select the Active Set tab and add the new run page. You can arrange the order of displayed pages by using the arrow buttons after selecting a page on the list.
How do I add shortcut keys to the JOHN DEERE SEEDSTAR N500C?
To add shortcut keys, follow these steps:
1. Select Menu.
2. Select the Applications tab.
3. Select the Layout Manager application.
4. Select the Shortcut Bars tab.
5. Select the shortcut bar to edit.
6. Select the shortcut keys to remove or add. After selecting Add, choose an application to see the associated shortcuts available.
7. Select a shortcut key to add and save the edited shortcut bar.
How do I prime the delivery system on the JOHN DEERE SEEDSTAR N500C?
To prime the delivery system and avoid skips, select the option to engage the meter drives while the machine is stationary.
What do the color indicators on the run pages of the JOHN DEERE SEEDSTAR N500C represent?
The colors used on tiles indicate the following status:
Green: The status is within a target range.
Red: The status is outside an alarm limit.
Gray: The status is inactive.
What do the RelativeFlow blockage color indicators represent on the JOHN DEERE SEEDSTAR N500C?
The colors used for sensors on bar graphs and frame sections indicate the following:
Green: Indicates an active sensor with product flowing.
Red: Indicates a blocked secondary hose.
Yellow: Indicates an unexpected flow detection on an inactive sensor.
Gray: Indicates a missing or extra sensor detected by the blockage software.
Clear: Indicates an inactive sensor with no product flowing.
Black: Indicates a manually disabled sensor.
How do I manually command sections on the JOHN DEERE SEEDSTAR N500C?
To command sections on and off, enter the JOHN DEERE SEEDSTAR N500C application and select the option to access manual control of the sections. You can then use the buttons for manual command of the sections.
How do I enable or disable sensors on the JOHN DEERE SEEDSTAR N500C?
You can use the Sensor Toggle Button to enable and disable a selected sensor. To enable all sensors that are manually disabled, use the Enable Sensors button. This button is only shown when one or more sensors are disabled.
How do I clear blocked sensors on the JOHN DEERE SEEDSTAR N500C?
Select the Reset button to clear currently blocked sensors. This button is only enabled when there is an issue and the meters are stopped.
How do I adjust the downforce on the JOHN DEERE SEEDSTAR N500C?
Use the plus and minus buttons on the run page to increase or decrease the target force of the openers. You can also select the field to manually input a value.
How do I adjust advanced downforce settings on the JOHN DEERE SEEDSTAR N500C?
Enter the Advanced Settings from the JOHN DEERE SEEDSTAR N500C application to adjust the following:
Increment Adjust: Defines the amount downforce adjusts when plus and minus buttons are selected.
Down Force Disabled Warning Delay: Defines the amount of time that passes before a warning is given that downforce has been disabled.
Failed to reach Set Point Timeout: Defines the amount of time that passes before a warning is given that the downforce setting was not achieved.
How do I configure the tank and blockage alarm on the JOHN DEERE SEEDSTAR N500C?
Select the option to access the tank and blockage alarm setup. From there, you can configure the blockage alarm and set the Tank Alarm Trigger by choosing between Area to Empty (defines a remaining coverage area) or Tank Scale (defines a remaining tank weight, if equipped). You can also set the Tank Threshold, which defines the level at which the tank alarm is triggered.
How do I configure blockage alarm behaviors on the JOHN DEERE SEEDSTAR N500C?
Within the blockage alarm setup, you can select the following alarm behaviors:
Alarm on Block: A message appears on the screen and an audible alert is made.
Beep on Block: An audible alert is made.
Do Nothing: No notification is given.
You can also adjust the following advanced settings:
Blockage Delay: Defines the amount of time a blockage is sensed before an alarm sounds.
Blockage Alarm Reminder: Defines the amount of time the alarm remains silenced by the operator.
Meter ON Delay: Defines the amount of time that the software waits to detect product at the blockage sensor after meter activation.
Meter OFF Delay: Defines the amount of time that the software waits for detected product to clear after the meters are deactivated.
CLICK HERE TO DOWNLOAD JOHN DEERE SEEDSTAR N500C (01) PDF DOCUMENT