What care recommendations should be followed for the WESTERMO SDW-532-MM-ST2 to maintain full operation and fulfill warranty obligations?

Follow the care recommendations below to maintain full operation of the unit and to fulfill the warranty obligations:

  • This unit must not be operating with removed covers or lids.
  • Do not attempt to disassemble the unit. There are no user serviceable parts inside.
  • Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards.
  • Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.
  • Do not paint the unit. Paint can clog the unit and prevent proper operation.
  • Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels.
  • Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged.
  • If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support.
  • Fibre connectors are supplied with plugs to avoid contamination inside the optical port. As long as no optical fibre is mounted on the connector, e.g. for storage, service or transportation, should the plug be applied.

What is the legal information regarding the contents of the documentation for the WESTERMO SDW-532-MM-ST2?

The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.

Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.


What is the safety warning regarding Class 1 Laser Product for the WESTERMO SDW-532-MM-ST2?

Do not look directly into fibre optical fibre port or any connected fibre although this unit is designed to meet the Class 1 Laser regulations.


What are the recommendations for handling fibre optic equipment in the WESTERMO SDW-532-MM-ST2?

Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If the fibre will be disconnected from the modem the protective hood on the transmitter/receiver must be connected. The protective hood must be kept on during transportation. The fibre optic cable must also be handle the same way.

If this recommendation not will be followed it can jeopardise the warranty.


How should the optical connectors of the WESTERMO SDW-532-MM-ST2 be cleaned?

In the event of contamination, the optical connectors should be cleaned by the use of forced nitrogen and some kind of cleaning stick.

Recommended cleaning fluids:

  • Methyl-, ethyl-, isopropyl- or isobutyl-alcohol
  • Hexane
  • Naphtha

What maintenance is required for the WESTERMO SDW-532-MM-ST2?

No maintenance is required, as long as the unit is used as intended within the specified conditions.


What are the legal requirements for product disposal of the WESTERMO SDW-532-MM-ST2?

This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it. It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment.

By ensuring this product is disposed of correctly, you will help to reduce hazardous substances and prevent potential negative consequences to both environment and human health, which could be caused by inappropriate disposal.


What are the characteristics of the WESTERMO SDW-532-MM-ST2 model?

Article Model Description
3644-0031 SDW-532-MM-ST2 10/100Base-T/TX: 3 ports 100Base-FX: 2 port

What are the isolation specifications between interfaces for the WESTERMO SDW-532-MM-ST2?

Isolation between interfaces
Power Interface to all other 2.8 kV DC 2.0 kV RMS @ 50 Hz and 60 s duration
TX signal Interface to all other 2.1 kV DC 1.5 kV RMS @ 50 Hz and 60 s duration
TX shield Interface to all other 1.5 kV DC 1.0 kV RMS @ 50 Hz and 60 s duration

What are the environmental conditions for the WESTERMO SDW-532-MM-ST2 regarding temperature, humidity, and altitude?

Environmental
Temperature, operating -25 to +60°C (SDW-532)
Temperature, storage and transportation -25 to +70°C
Relative humidity, operating 5 to 95% (non-condensing)
Relative humidity, storage and transportation 5 to 95% (condensation allowed outside packaging)
Altitude, operating 2000 m/70 kPa

What are the mechanical specifications for the WESTERMO SDW-532-MM-ST2?

Mechanical
Dimension (W x H x D) 35 x 121 x 119 mm
Weight 0.2 kg
Mounting DIN-rail
Degree of protection IP21

How is the WESTERMO SDW-532-MM-ST2 configured?

The WESTERMO SDW-532-MM-ST2 is Auto configured (auto-negotiation) or manually setting of speed and duplex of individual TX port, by DIP-switches.

Port mirror function is possible to set with DIP-switch. With the port mirror function active the switch will copy all outgoing traffic to port 1. This can be used to monitor all traffic going out from the switch. Packets may be discarded if the total throughput exceeds the port speed of port 1.


What is the fibre optic power budget for the Multimode MM-xx2 model of the WESTERMO SDW-532-MM-ST2?

Model Multimode MM-xx2 Singlemode SM-SC15 Singlemode SM-LC15 Singlemode SM-LC40
Transmitted wavelength 1310 nm 1310 nm 1310 nm 1310 nm
Min. output power, transmitter -19 dBm -15 dBm -15 dBm -5 dBm
Max. output power, transmitter -12 dBm -8 dBm -8 dBm 0 dBm
Input sensitivity, receiver -31 dBm -34 dBm -31 dBm -34 dBm
Min. power budget 12 dBm 19 dBm 16 dBm 29 dBm
Max. power budget 19 dBm 26 dBm 23 dBm 34 dBm
Recommended fibre cable and core / cladding diameter 50/125 9/125 9/125 9/125
62.5/125 10/125 10/125 10/125

What is the normal attenuation in connectors and splices for the WESTERMO SDW-532-MM-ST2?

Type Normal attenuation
Connector 0.2 – 0.4 dBm
Fusion splice 0.1 dBm
Mechanical splice 0.2 dBm

What is the power interface specification for the WESTERMO SDW-532-MM-ST2?

Power SDW-500 series
Rated voltage 12-48 VDC, polarity protected
Operating voltage 9.6 – 57.6 VDC
Rated current @12 VDC power input
SDW-532-MM-ST2 600 mA
Rated frequency DC
Connection Detachable screw terminal
Connector size 0.2 – 2.5 mm² (AWG 24-12)

What are the Ethernet TX specifications for the WESTERMO SDW-532-MM-ST2?

Ethernet TX
Electrical specification IEEE std 802.3. 2000 edition
Data rate 10 Mbit/s or 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Connection SC, ST or LC
Circuit type Optical
Transmission range 100 m

What are the Ethernet FX specifications for the WESTERMO SDW-532-MM-ST2?

Ethernet FX
Electrical specification IEEE std 802.3. 2000 edition
Data rate 10 Mbit/s or 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Connection SC, ST or LC
Circuit type Optical
Transmission range 100 m

What are the connections for the power supply on the WESTERMO SDW-532-MM-ST2?

The WESTERMO SDW-532-MM-ST2 supports redundant power connection. The positive inputs are +VA and +VB, and the negative input for both supplies is COM. The power is drawn from the input with the highest voltage.

3-pos screw terminal Description Power
1 COM 0 V
2 +VA A: 9.6 – 57.6 VDC
3 +VB B: 9.6 – 57.6 VDC

What are the contact details for the Ethernet TX connection (RJ-45 connector) on the WESTERMO SDW-532-MM-ST2?

The Ethernet TX connection uses an RJ-45 connector with automatic MDI/MDI-X crossover. CAT 5 cable is recommended. Unshielded (UTP) or shielded (STP) connector might be used.

Contact Signal Name Direction Description/Remark
1 TD+ In/Out Transmitted/Received data
2 TD- In/Out Transmitted/Received data
3 RD+ In/Out Transmitted/Received data
4
5
6 RD- In/Out Transmitted/Received data
7
8
Shield HF-connected

How is the FX ST Multi mode (optional) Ethernet FX connection implemented on the WESTERMO SDW-532-MM-ST2?

The Ethernet FX connection uses a 1300 nm multi mode fibre transceiver with ST-connector. The dust protection plugs shall be mounted when no fibre is connected.


What do the LED indicators on the WESTERMO SDW-532-MM-ST2 signify?

At power on the PWR flashes during initialising. The indicators (LED) are Power (PWR), Link (LINK) of every port, and Speed (SPD) and duplex (DPX) of TX ports.

LED Status Indication of
PWR ON Internal power, initialising OK
Slow flash Initialisation progressing
Fast flash Initialisation error
LINK OFF No Ethernet link
ON Good Ethernet link
Flash Ethernet data is transmitted or received, traffic indication
SPD (TX only) OFF 10 Mbit/s
ON 100 Mbit/s
DPX (TX only) OFF Half duplex
ON Full duplex

How are the DIP-switches accessed and used to configure the WESTERMO SDW-532-MM-ST2?

DIP-switches are accessible under the lid on top of the unit. DIP-switches are used to configure the unit. When configuration via DIP-switches, the settings of DIP-switches configure the unit only after a reboot (power off/on).

To be observed when the DIP-switches will be configured:

  • Speed and duplex setting only valid when auto-negotiation is disabled.
  • When monitoring selected all outgoing packets from the switch is also copied to the port 1.
  • Speed and duplex switch settings are ignored for FX ports.
  • If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X configuration.

What are the safety precautions before accessing the DIP-switches or opening the WESTERMO SDW-532-MM-ST2?

Warning! Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap), before the lid on top/front of the unit is removed.

Warning! Do not open connected equipment. Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections.


What are the DIP switch settings for Port 1 of the WESTERMO SDW-532-MM-ST2?

Switch Setting Configuration
S1 ON, 1, 2, 3, 4, 5, 6, 7, 8 OFF Auto-negotiation and auto MDI/MDI-X disabled
S1 ON, 1, 2, 3, 4, 5, 6, 7, 8 ON Auto-negotiation and auto MDI/MDI-X enabled
S1 ON, 1, 2, 3, 4, 5, 6, 7, 8 OFF (5 OFF) 10 Mbit/s speed selected
S1 ON, 1, 2, 3, 4, 5, 6, 7, 8 ON (5 ON) 100 Mbit/s speed selected
S1 ON, 1, 2, 3, 4, 5, 6, 7, 8 OFF (6 OFF) Half duplex selected
S1 ON, 1, 2, 3, 4, 5, 6, 7, 8 ON (6 ON) Full duplex selected

What are the DIP switch settings for Port 2 of the WESTERMO SDW-532-MM-ST2?

Switch Setting Configuration
S1 ON, 1, 2, 3, 4, 5, 6, 7, 8 OFF (7 OFF) Auto-negotiation and auto MDI/MDI-X disabled
S1 ON, 1, 2, 3, 4, 5, 6, 7, 8 ON (7 ON) Auto-negotiation and auto MDI/MDI-X enabled
S1 ON, 1, 2, 3, 4, 5, 6, 7, 8 OFF (3 OFF) 10 Mbit/s speed selected
S1 ON, 1, 2, 3, 4, 5, 6, 7, 8 ON (3 ON) 100 Mbit/s speed selected
S1 ON, 1, 2, 3, 4, 5, 6, 7, 8 OFF (4 OFF) Half duplex selected
S1 ON, 1, 2, 3, 4, 5, 6, 7, 8 ON (4 ON) Full duplex selected

What are the DIP switch settings for Port 3 of the WESTERMO SDW-532-MM-ST2?

Switch Setting Configuration
S1 ON, 1, 2, 3, 4, 5, 6, 7, 8 OFF (5 OFF) Auto-negotiation and auto MDI/MDI-X disabled
S1 ON, 1, 2, 3, 4, 5, 6, 7, 8 ON (5 ON) Auto-negotiation and auto MDI/MDI-X enabled
S1 ON, 1, 2, 3, 4, 5, 6, 7, 8 OFF (1 OFF) 10 Mbit/s speed selected
S1 ON, 1, 2, 3, 4, 5, 6, 7, 8 ON (1 ON) 100 Mbit/s speed selected
S2 ON, 1, 2, 3, 4, 5, 6, 7, 8 OFF (6 OFF) Half duplex selected
S2 ON, 1, 2, 3, 4, 5, 6, 7, 8 ON (6 ON) Full duplex selected

What are the DIP switch settings for Port mirroring on the WESTERMO SDW-532-MM-ST2?

Switch Setting Configuration
S2 ON, 1, 2, 3, 4, 5 OFF No monitoring selected
S2 ON, 1, 2, 3, 4, 5 ON Monitoring selected

What are the DIP switch settings for Flow control on the WESTERMO SDW-532-MM-ST2?

Switch Setting Configuration
S3 ON, 1, 2, 3, 4 ON Flow control selected
S3 ON, 1, 2, 3, 4 OFF No flow control selected

What are the factory DIP switch settings for the WESTERMO SDW-532-MM-ST2?

Switch Setting
S1 ON, 1, 2, 3, 4, 5, 6, 7, 8 ON (Factory settings: 1, 2, 3, 4, 5, 6, 7, 8 are ON)
S2 ON, 1, 2, 3, 4, 5, 6, 7, 8 ON (Factory settings: 1, 2, 3, 4, 5, 6, 7, 8 are ON)
S3 ON, 1, 2, 3, 4 ON (Factory settings: 1, 2, 3, 4 are ON)

What are the installation requirements and recommended spacing for mounting the WESTERMO SDW-532-MM-ST2?

This unit should be mounted on 35 mm DIN-rail which is horizontally mounted on a wall or cabinet backplate.

This unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules. Recommended spacing 25 mm (1.0 inch) above/below and 10 mm (0.4 inches) left/right the unit.

Before mounting or removing the unit:

  • Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap).
  • Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections.

How is the WESTERMO SDW-532-MM-ST2 removed from the DIN-rail?

Press down the black support at the back of the unit.