What safety precautions should be followed before installing the WESTERMO SDW-532-MM-SC2-SM-SC15?
Before installation, read the manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit.
This unit should only be installed by qualified personnel.
This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only.
The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations.
This unit uses convection cooling. To avoid obstructing the air flow around the unit, follow the spacing recommendations (see Installation section).
What safety precautions should be taken before mounting, using, or removing the WESTERMO SDW-532-MM-SC2-SM-SC15?
Prevent access to hazardous voltage by disconnecting the unit from power supply.
Warning! Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply.
What care recommendations should be followed for the WESTERMO SDW-532-MM-SC2-SM-SC15?
Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations.
This unit must not be operating with removed covers or lids.
Do not attempt to disassemble the unit. There are no user serviceable parts inside.
Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards.
Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.
Do not paint the unit. Paint can clog the unit and prevent proper operation.
Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels.
Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged.
If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support.
Fibre connectors are supplied with plugs to avoid contamination inside the optical port. As long as no optical fibre is mounted on the connector, e.g. for storage, service or transportation, should the plug be applied.
What is the note regarding Fibre Optic Handling for the WESTERMO SDW-532-MM-SC2-SM-SC15?
Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If the fibre will be disconnected from the modem the protective hood on the transmitter/receiver must be connected. The protective hood must be kept on during transportation. The fibre optic cable must also be handle the same way.
If this recommendation not will be followed it can jeopardise the warranty.
How should the optical connectors of the WESTERMO SDW-532-MM-SC2-SM-SC15 be cleaned?
In the event of contamination, the optical connectors should be cleaned by the use of forced nitrogen and some kind of cleaning stick.
Recommended cleaning fluids:
- Methyl-, ethyl-, isopropyl- or isobutyl-alcohol
- Hexane
- Naphtha
What maintenance is required for the WESTERMO SDW-532-MM-SC2-SM-SC15?
No maintenance is required, as long as the unit is used as intended within the specified conditions.
What are the environmental conditions for the WESTERMO SDW-532-MM-SC2-SM-SC15 regarding isolation between interfaces?
| Isolation between interfaces | |
| Power Interface to all other | 2.8 kV DC 2.0 kV RMS @ 50 Hz and 60 s duration |
| TX signal Interface to all other | 2.1 kV DC 1.5 kV RMS @ 50 Hz and 60 s duration |
| TX shield Interface to all other | 1.5 kV DC 1.0 kV RMS @ 50 Hz and 60 s duration |
What are the environmental conditions for the WESTERMO SDW-532-MM-SC2-SM-SC15 regarding temperature and humidity?
| Environmental | |
| Temperature, operating | -25 to +60°C (SDW-532) |
| Temperature, storage and transportation | -25 to +70°C |
| Relative humidity, operating | 5 to 95% (non-condensing) |
| Relative humidity, storage and transportation | 5 to 95% (condensation allowed outside packaging) |
| Altitude, operating | 2000 m/70 kPa |
What are the mechanical specifications for the WESTERMO SDW-532-MM-SC2-SM-SC15?
| Mechanical | |
| Dimension (W x H x D) | 35 x 121 x 119 mm |
| Weight | 0.2 kg |
| Mounting | DIN-rail |
| Degree of protection | IP21 |
How is the configuration set on the WESTERMO SDW-532-MM-SC2-SM-SC15?
The WESTERMO SDW-532-MM-SC2-SM-SC15 is auto configured (auto-negotiation) or allows manually setting of speed and duplex of individual TX port, by DIP-switches.
Port mirror function is possible to set with DIP-switch. With the port mirror function active the switch will copy all outgoing traffic to port 1. This can be used to monitor all traffic going out from the switch. Packets may be discarded if the total throughput exceeds the port speed of port 1.
What are the specifications for the Fibre optic power budget for the WESTERMO SDW-532-MM-SC2-SM-SC15?
The WESTERMO SDW-532-MM-SC2-SM-SC15 includes Multi-mode and Single-mode fibre ports. The relevant specifications for the ports on the WESTERMO SDW-532-MM-SC2-SM-SC15 are as follows:
| Model | Multimode MM-xx2 | Singlemode SM-SC15 |
| Transmitted wavelength | 1310 nm | 1310 nm |
| Min. output power, transmitter | -19 dBm | -15 dBm |
| Max. output power, transmitter | -12 dBm | -8 dBm |
| Input sensitivity, receiver | -31 dBm | -34 dBm |
| Min. power budget | 12 dBm | 19 dBm |
| Max. power budget | 19 dBm | 26 dBm |
| Recommended fibre cable and core / cladding diameter | 50/125 62.5/125 |
9/125 10/125 |
What is the attenuation in connectors and splices for the WESTERMO SDW-532-MM-SC2-SM-SC15?
| Type | Normal attenuation |
| Connector | 0.2 – 0.4 dBm |
| Fusion splice | 0.1 dBm |
| Mechanical splice | 0.2 dBm |
What are the key features of the WESTERMO SDW-532-MM-SC2-SM-SC15?
Features:
- TX shields individually isolated
- Wide DC power range 12 – 48 VDC
- Wide temperature range
- Automatic MDI/MDI-X crossover
- LED indicators for Power, Speed, Duplex, Link and Traffic
- Port monitoring
- 35 mm DIN rail mounting
- Enable or disable of flow control
What are example applications for the WESTERMO SDW-532-MM-SC2-SM-SC15?
Example of applications are:
- 5-port switch
- Ethernet isolator, for STP networks
What are the power specifications for the WESTERMO SDW-532-MM-SC2-SM-SC15?
| Power SDW-500 series | |
| Rated voltage | 12 – 48 VDC, polarity protected |
| Operating voltage | 9.6 – 57.6 VDC |
| Rated current | @12VDC power input |
| WESTERMO SDW-532-MM-SC2-SM-SC15 | 450 mA |
| Rated frequency | DC |
| Connection | Detachable screw terminal |
| Connector size | 0.2 – 2.5 mm² (AWG 24-12) |
What are the Ethernet TX interface specifications for the WESTERMO SDW-532-MM-SC2-SM-SC15?
| Ethernet TX | |
| Electrical specification | IEEE std 802.3. 2000 edition |
| Data rate | 10 Mbit/s or 100 Mbit/s, manual or auto |
| Duplex | Full or half, manual or auto |
| Connection | SC, ST or LC |
| Circuit type | Optical |
| Transmission range | 100 m |
What are the Ethernet FX interface specifications for the WESTERMO SDW-532-MM-SC2-SM-SC15?
| Ethernet FX | |
| Electrical specification | IEEE std 802.3. 2000 edition |
| Data rate | 10 Mbit/s or 100 Mbit/s, manual or auto |
| Duplex | Full or half, manual or auto |
| Connection | SC, ST or LC |
| Circuit type | Optical |
| Transmission range | 100 m |
How does the Power connection work on the WESTERMO SDW-532-MM-SC2-SM-SC15?
The WESTERMO SDW-532-MM-SC2-SM-SC15 supports redundant power connection. The positive input are +VA and +VB, the negative input for both supplies are COM. The power is drawn from the input with the highest voltage.
| 3-pos screw terminal | Description | Power |
| 1 | COM | 0 V |
| 2 | +VA | A: 9.6 – 57.6 VDC |
| 3 | +VB | B: 9.6 – 57.6 VDC |
What are the connections for the Ethernet TX (RJ-45 connector) on the WESTERMO SDW-532-MM-SC2-SM-SC15?
Ethernet TX connection (RJ-45 connector), automatic MDI/MDI-X crossover.
| Contact | Signal Name | Direction | Description/Remark |
| 1 | TD+ | In/Out | Transmitted/Received data |
| 2 | TD- | In/Out | Transmitted/Received data |
| 3 | RD+ | In/Out | Transmitted/Received data |
| 4 | – | – | – |
| 5 | – | – | – |
| 6 | RD- | In/Out | Transmitted/Received data |
| 7 | – | – | – |
| 8 | – | – | – |
| Shield | – | – | HF-connected |
CAT 5 cable is recommended. Unshielded (UTP) or shielded (STP) connector might be used.
What are the requirements for FX SC Multi- or single mode connection on the WESTERMO SDW-532-MM-SC2-SM-SC15?
Ethernet FX connection. 1300 nm multi- or singlemode fibre tranceiver with SC-connector. The dust protection plug shall be mounted when no fibre is connected.
What are the requirements for FX ST Multi mode connection on the WESTERMO SDW-532-MM-SC2-SM-SC15?
Ethernet FX connection. 1300 nm multi mode fibre tranceiver with ST-connector. The dust protection plugs shall be mounted when no fibre is connected.
What are the requirements for FX LC Multi- or single mode connection on the WESTERMO SDW-532-MM-SC2-SM-SC15?
Ethernet FX connection. 1300 nm singlemode fibre transceiver with LC-connector. The dust protection plug shall be mounted when no fibre is connected.
What do the LED indicators on the WESTERMO SDW-532-MM-SC2-SM-SC15 signify?
At power on the PWR flashes during initialising.
Indicators (LED):
- Power (PWR)
- Link (LINK) of every port
- Speed (SPD) and duplex (DPX) of TX ports
| LED | Status | Indication of |
| PWR | ON | Internal power, initialising OK |
| Slow flash | Initialisation progressing | |
| Fast flash | Initialisation error | |
| LINK | OFF | No Ethernet link |
| ON | Good Ethernet link | |
| Flash | Ethernet data is transmitted or received, traffic indication | |
| SPD (TX only) | OFF | 10 Mbit/s |
| ON | 100 Mbit/s | |
| DPX (TX only) | OFF | Half duplex |
| ON | Full duplex |
How are DIP-switches used to configure the WESTERMO SDW-532-MM-SC2-SM-SC15?
DIP-switches are accessible under the lid on top of the unit. DIP-switches are used to configure the unit. When configuration via DIP-switches, the settings of DIP-switches configure the unit only after a reboot (power off/on).
What warnings should be observed when accessing the DIP-switches on the WESTERMO SDW-532-MM-SC2-SM-SC15?
Warning! Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap), before the lid on top/front of the unit is removed.
Warning! Do not open connected equipment. Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections.
What must be observed when configuring the DIP-switches on the WESTERMO SDW-532-MM-SC2-SM-SC15?
To be observe when the DIP-switches will be configured:
- Speed and duplex setting only valid when auto-negotiation is disabled.
- When monitoring selected all outgoing packets from the switch is also copied to the port 1.
- Speed and duplex switch settings are ignored for FX ports.
- If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X configuration.
What are the DIP switch settings for Port 1 on the WESTERMO SDW-532-MM-SC2-SM-SC15?
Port 1 settings:
- Auto-negotiation and auto MDI/MDI-X disabled: S1 switch with pins 1, 2, 3, 4, 5, 6, 7, 8 OFF.
- Auto-negotiation and auto MDI/MDI-X enabled: S1 switch with pins 1, 2, 3, 4, 5, 6, 7, 8 ON.
- 10 Mbit/s speed selected: S1 switch with pin 8 OFF and pins 1, 2, 3, 4, 5, 6, 7 ON.
- 100 Mbit/s speed selected: S1 switch with pin 8 ON and pins 1, 2, 3, 4, 5, 6, 7 OFF.
- Half duplex selected: S1 switch with pin 7 OFF and pins 1, 2, 3, 4, 5, 6, 8 ON.
- Full duplex selected: S1 switch with pin 7 ON and pins 1, 2, 3, 4, 5, 6, 8 OFF.
What are the DIP switch settings for Port 2 on the WESTERMO SDW-532-MM-SC2-SM-SC15?
Port 2 settings:
- Auto-negotiation and auto MDI/MDI-X disabled: S1 switch with pins 1, 2, 3, 4, 5, 6, 7, 8 OFF.
- Auto-negotiation and auto MDI/MDI-X enabled: S1 switch with pins 1, 2, 3, 4, 5, 6, 7, 8 ON.
- 10 Mbit/s speed selected: S1 switch with pin 6 OFF and pins 1, 2, 3, 4, 5, 7, 8 ON.
- 100 Mbit/s speed selected: S1 switch with pin 6 ON and pins 1, 2, 3, 4, 5, 7, 8 OFF.
- Half duplex selected: S1 switch with pin 5 OFF and pins 1, 2, 3, 4, 6, 7, 8 ON.
- Full duplex selected: S1 switch with pin 5 ON and pins 1, 2, 3, 4, 6, 7, 8 OFF.
What are the DIP switch settings for Port 3 on the WESTERMO SDW-532-MM-SC2-SM-SC15?
Port 3 settings:
- Auto-negotiation and auto MDI/MDI-X disabled: S1 switch with pins 1, 2, 3, 4, 5, 6, 7, 8 OFF.
- Auto-negotiation and auto MDI/MDI-X enabled: S1 switch with pins 1, 2, 3, 4, 5, 6, 7, 8 ON.
- 10 Mbit/s speed selected: S1 switch with pin 4 OFF and pins 1, 2, 3, 5, 6, 7, 8 ON.
- 100 Mbit/s speed selected: S1 switch with pin 4 ON and pins 1, 2, 3, 5, 6, 7, 8 OFF.
- Half duplex selected: S2 switch with pin 8 OFF and pins 1, 2, 3, 4, 5, 6, 7 ON.
- Full duplex selected: S2 switch with pin 8 ON and pins 1, 2, 3, 4, 5, 6, 7 OFF.
What are the DIP switch settings for Port mirroring on the WESTERMO SDW-532-MM-SC2-SM-SC15?
Port mirroring settings:
- No monitoring selected: S2 switch with pins 1, 2, 3, 4, 5 OFF.
- Monitoring selected: S2 switch with pin 5 ON and pins 1, 2, 3, 4 OFF.
What are the DIP switch factory settings for the WESTERMO SDW-532-MM-SC2-SM-SC15?
Factory settings:
- S1 switch: pins 1, 2, 3, 4, 5, 6, 7, 8 ON.
- S2 switch: pins 1, 2, 3, 4, 5 ON, pins 6, 7, 8 OFF.
How should the WESTERMO SDW-532-MM-SC2-SM-SC15 be mounted?
This unit should be mounted on 35 mm DIN-rail which is horizontally mounted on a wall or cabinet backplate. This unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules. Recommended spacing 25 mm (1.0 inch) above/below and 10 mm (0.4 inches) left/right the unit. Snap on mounting.
How should the WESTERMO SDW-532-MM-SC2-SM-SC15 be removed?
Press down the black support at the back of the unit.
What are the connections for the WESTERMO SDW-532-MM-SC2-SM-SC15?
The connections for the WESTERMO SDW-532-MM-SC2-SM-SC15 are:
- Network RJ-45 connection (Ports 1, 2, 3)
- Power connection
- Network Fibre connection (Ports 4, 5)
For the WESTERMO SDW-532-MM-SC2-SM-SC15 specifically:
- Port 4: SC Single mode 15 km connector
- Port 5: SC Multi mode 2 km connector