What safety precautions should be followed before installing the WESTERMO SDW-532-MM-SC2-SM-SC15?

Before installation, read the manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit.

This unit should only be installed by qualified personnel.

This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only.

The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations.

This unit uses convection cooling. To avoid obstructing the air flow around the unit, follow the spacing recommendations (see Installation section).


What safety precautions should be taken before mounting, using, or removing the WESTERMO SDW-532-MM-SC2-SM-SC15?

Prevent access to hazardous voltage by disconnecting the unit from power supply.

Warning! Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply.


What care recommendations should be followed for the WESTERMO SDW-532-MM-SC2-SM-SC15?

Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations.

This unit must not be operating with removed covers or lids.

Do not attempt to disassemble the unit. There are no user serviceable parts inside.

Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards.

Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.

Do not paint the unit. Paint can clog the unit and prevent proper operation.

Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels.

Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged.

If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support.

Fibre connectors are supplied with plugs to avoid contamination inside the optical port. As long as no optical fibre is mounted on the connector, e.g. for storage, service or transportation, should the plug be applied.


What is the note regarding Fibre Optic Handling for the WESTERMO SDW-532-MM-SC2-SM-SC15?

Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If the fibre will be disconnected from the modem the protective hood on the transmitter/receiver must be connected. The protective hood must be kept on during transportation. The fibre optic cable must also be handle the same way.

If this recommendation not will be followed it can jeopardise the warranty.


How should the optical connectors of the WESTERMO SDW-532-MM-SC2-SM-SC15 be cleaned?

In the event of contamination, the optical connectors should be cleaned by the use of forced nitrogen and some kind of cleaning stick.

Recommended cleaning fluids:

  • Methyl-, ethyl-, isopropyl- or isobutyl-alcohol
  • Hexane
  • Naphtha

What maintenance is required for the WESTERMO SDW-532-MM-SC2-SM-SC15?

No maintenance is required, as long as the unit is used as intended within the specified conditions.


What are the environmental conditions for the WESTERMO SDW-532-MM-SC2-SM-SC15 regarding isolation between interfaces?

Isolation between interfaces
Power Interface to all other 2.8 kV DC 2.0 kV RMS @ 50 Hz and 60 s duration
TX signal Interface to all other 2.1 kV DC 1.5 kV RMS @ 50 Hz and 60 s duration
TX shield Interface to all other 1.5 kV DC 1.0 kV RMS @ 50 Hz and 60 s duration

What are the environmental conditions for the WESTERMO SDW-532-MM-SC2-SM-SC15 regarding temperature and humidity?

Environmental
Temperature, operating -25 to +60°C (SDW-532)
Temperature, storage and transportation -25 to +70°C
Relative humidity, operating 5 to 95% (non-condensing)
Relative humidity, storage and transportation 5 to 95% (condensation allowed outside packaging)
Altitude, operating 2000 m/70 kPa

What are the mechanical specifications for the WESTERMO SDW-532-MM-SC2-SM-SC15?

Mechanical
Dimension (W x H x D) 35 x 121 x 119 mm
Weight 0.2 kg
Mounting DIN-rail
Degree of protection IP21

How is the configuration set on the WESTERMO SDW-532-MM-SC2-SM-SC15?

The WESTERMO SDW-532-MM-SC2-SM-SC15 is auto configured (auto-negotiation) or allows manually setting of speed and duplex of individual TX port, by DIP-switches.

Port mirror function is possible to set with DIP-switch. With the port mirror function active the switch will copy all outgoing traffic to port 1. This can be used to monitor all traffic going out from the switch. Packets may be discarded if the total throughput exceeds the port speed of port 1.


What are the specifications for the Fibre optic power budget for the WESTERMO SDW-532-MM-SC2-SM-SC15?

The WESTERMO SDW-532-MM-SC2-SM-SC15 includes Multi-mode and Single-mode fibre ports. The relevant specifications for the ports on the WESTERMO SDW-532-MM-SC2-SM-SC15 are as follows:

Model Multimode MM-xx2 Singlemode SM-SC15
Transmitted wavelength 1310 nm 1310 nm
Min. output power, transmitter -19 dBm -15 dBm
Max. output power, transmitter -12 dBm -8 dBm
Input sensitivity, receiver -31 dBm -34 dBm
Min. power budget 12 dBm 19 dBm
Max. power budget 19 dBm 26 dBm
Recommended fibre cable and core / cladding diameter 50/125
62.5/125
9/125
10/125

What is the attenuation in connectors and splices for the WESTERMO SDW-532-MM-SC2-SM-SC15?

Type Normal attenuation
Connector 0.2 – 0.4 dBm
Fusion splice 0.1 dBm
Mechanical splice 0.2 dBm

What are the key features of the WESTERMO SDW-532-MM-SC2-SM-SC15?

Features:

  • TX shields individually isolated
  • Wide DC power range 12 – 48 VDC
  • Wide temperature range
  • Automatic MDI/MDI-X crossover
  • LED indicators for Power, Speed, Duplex, Link and Traffic
  • Port monitoring
  • 35 mm DIN rail mounting
  • Enable or disable of flow control

What are example applications for the WESTERMO SDW-532-MM-SC2-SM-SC15?

Example of applications are:

  • 5-port switch
  • Ethernet isolator, for STP networks

What are the power specifications for the WESTERMO SDW-532-MM-SC2-SM-SC15?

Power SDW-500 series
Rated voltage 12 – 48 VDC, polarity protected
Operating voltage 9.6 – 57.6 VDC
Rated current @12VDC power input
WESTERMO SDW-532-MM-SC2-SM-SC15 450 mA
Rated frequency DC
Connection Detachable screw terminal
Connector size 0.2 – 2.5 mm² (AWG 24-12)

What are the Ethernet TX interface specifications for the WESTERMO SDW-532-MM-SC2-SM-SC15?

Ethernet TX
Electrical specification IEEE std 802.3. 2000 edition
Data rate 10 Mbit/s or 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Connection SC, ST or LC
Circuit type Optical
Transmission range 100 m

What are the Ethernet FX interface specifications for the WESTERMO SDW-532-MM-SC2-SM-SC15?

Ethernet FX
Electrical specification IEEE std 802.3. 2000 edition
Data rate 10 Mbit/s or 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Connection SC, ST or LC
Circuit type Optical
Transmission range 100 m

How does the Power connection work on the WESTERMO SDW-532-MM-SC2-SM-SC15?

The WESTERMO SDW-532-MM-SC2-SM-SC15 supports redundant power connection. The positive input are +VA and +VB, the negative input for both supplies are COM. The power is drawn from the input with the highest voltage.

3-pos screw terminal Description Power
1 COM 0 V
2 +VA A: 9.6 – 57.6 VDC
3 +VB B: 9.6 – 57.6 VDC

What are the connections for the Ethernet TX (RJ-45 connector) on the WESTERMO SDW-532-MM-SC2-SM-SC15?

Ethernet TX connection (RJ-45 connector), automatic MDI/MDI-X crossover.

Contact Signal Name Direction Description/Remark
1 TD+ In/Out Transmitted/Received data
2 TD- In/Out Transmitted/Received data
3 RD+ In/Out Transmitted/Received data
4
5
6 RD- In/Out Transmitted/Received data
7
8
Shield HF-connected

CAT 5 cable is recommended. Unshielded (UTP) or shielded (STP) connector might be used.


What are the requirements for FX SC Multi- or single mode connection on the WESTERMO SDW-532-MM-SC2-SM-SC15?

Ethernet FX connection. 1300 nm multi- or singlemode fibre tranceiver with SC-connector. The dust protection plug shall be mounted when no fibre is connected.


What are the requirements for FX ST Multi mode connection on the WESTERMO SDW-532-MM-SC2-SM-SC15?

Ethernet FX connection. 1300 nm multi mode fibre tranceiver with ST-connector. The dust protection plugs shall be mounted when no fibre is connected.


What are the requirements for FX LC Multi- or single mode connection on the WESTERMO SDW-532-MM-SC2-SM-SC15?

Ethernet FX connection. 1300 nm singlemode fibre transceiver with LC-connector. The dust protection plug shall be mounted when no fibre is connected.


What do the LED indicators on the WESTERMO SDW-532-MM-SC2-SM-SC15 signify?

At power on the PWR flashes during initialising.

Indicators (LED):

  • Power (PWR)
  • Link (LINK) of every port
  • Speed (SPD) and duplex (DPX) of TX ports
LED Status Indication of
PWR ON Internal power, initialising OK
Slow flash Initialisation progressing
Fast flash Initialisation error
LINK OFF No Ethernet link
ON Good Ethernet link
Flash Ethernet data is transmitted or received, traffic indication
SPD (TX only) OFF 10 Mbit/s
ON 100 Mbit/s
DPX (TX only) OFF Half duplex
ON Full duplex

How are DIP-switches used to configure the WESTERMO SDW-532-MM-SC2-SM-SC15?

DIP-switches are accessible under the lid on top of the unit. DIP-switches are used to configure the unit. When configuration via DIP-switches, the settings of DIP-switches configure the unit only after a reboot (power off/on).


What warnings should be observed when accessing the DIP-switches on the WESTERMO SDW-532-MM-SC2-SM-SC15?

Warning! Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap), before the lid on top/front of the unit is removed.

Warning! Do not open connected equipment. Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections.


What must be observed when configuring the DIP-switches on the WESTERMO SDW-532-MM-SC2-SM-SC15?

To be observe when the DIP-switches will be configured:

  • Speed and duplex setting only valid when auto-negotiation is disabled.
  • When monitoring selected all outgoing packets from the switch is also copied to the port 1.
  • Speed and duplex switch settings are ignored for FX ports.
  • If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X configuration.

What are the DIP switch settings for Port 1 on the WESTERMO SDW-532-MM-SC2-SM-SC15?

Port 1 settings:

  • Auto-negotiation and auto MDI/MDI-X disabled: S1 switch with pins 1, 2, 3, 4, 5, 6, 7, 8 OFF.
  • Auto-negotiation and auto MDI/MDI-X enabled: S1 switch with pins 1, 2, 3, 4, 5, 6, 7, 8 ON.
  • 10 Mbit/s speed selected: S1 switch with pin 8 OFF and pins 1, 2, 3, 4, 5, 6, 7 ON.
  • 100 Mbit/s speed selected: S1 switch with pin 8 ON and pins 1, 2, 3, 4, 5, 6, 7 OFF.
  • Half duplex selected: S1 switch with pin 7 OFF and pins 1, 2, 3, 4, 5, 6, 8 ON.
  • Full duplex selected: S1 switch with pin 7 ON and pins 1, 2, 3, 4, 5, 6, 8 OFF.

What are the DIP switch settings for Port 2 on the WESTERMO SDW-532-MM-SC2-SM-SC15?

Port 2 settings:

  • Auto-negotiation and auto MDI/MDI-X disabled: S1 switch with pins 1, 2, 3, 4, 5, 6, 7, 8 OFF.
  • Auto-negotiation and auto MDI/MDI-X enabled: S1 switch with pins 1, 2, 3, 4, 5, 6, 7, 8 ON.
  • 10 Mbit/s speed selected: S1 switch with pin 6 OFF and pins 1, 2, 3, 4, 5, 7, 8 ON.
  • 100 Mbit/s speed selected: S1 switch with pin 6 ON and pins 1, 2, 3, 4, 5, 7, 8 OFF.
  • Half duplex selected: S1 switch with pin 5 OFF and pins 1, 2, 3, 4, 6, 7, 8 ON.
  • Full duplex selected: S1 switch with pin 5 ON and pins 1, 2, 3, 4, 6, 7, 8 OFF.

What are the DIP switch settings for Port 3 on the WESTERMO SDW-532-MM-SC2-SM-SC15?

Port 3 settings:

  • Auto-negotiation and auto MDI/MDI-X disabled: S1 switch with pins 1, 2, 3, 4, 5, 6, 7, 8 OFF.
  • Auto-negotiation and auto MDI/MDI-X enabled: S1 switch with pins 1, 2, 3, 4, 5, 6, 7, 8 ON.
  • 10 Mbit/s speed selected: S1 switch with pin 4 OFF and pins 1, 2, 3, 5, 6, 7, 8 ON.
  • 100 Mbit/s speed selected: S1 switch with pin 4 ON and pins 1, 2, 3, 5, 6, 7, 8 OFF.
  • Half duplex selected: S2 switch with pin 8 OFF and pins 1, 2, 3, 4, 5, 6, 7 ON.
  • Full duplex selected: S2 switch with pin 8 ON and pins 1, 2, 3, 4, 5, 6, 7 OFF.

What are the DIP switch settings for Port mirroring on the WESTERMO SDW-532-MM-SC2-SM-SC15?

Port mirroring settings:

  • No monitoring selected: S2 switch with pins 1, 2, 3, 4, 5 OFF.
  • Monitoring selected: S2 switch with pin 5 ON and pins 1, 2, 3, 4 OFF.

What are the DIP switch factory settings for the WESTERMO SDW-532-MM-SC2-SM-SC15?

Factory settings:

  • S1 switch: pins 1, 2, 3, 4, 5, 6, 7, 8 ON.
  • S2 switch: pins 1, 2, 3, 4, 5 ON, pins 6, 7, 8 OFF.

How should the WESTERMO SDW-532-MM-SC2-SM-SC15 be mounted?

This unit should be mounted on 35 mm DIN-rail which is horizontally mounted on a wall or cabinet backplate. This unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules. Recommended spacing 25 mm (1.0 inch) above/below and 10 mm (0.4 inches) left/right the unit. Snap on mounting.


How should the WESTERMO SDW-532-MM-SC2-SM-SC15 be removed?

Press down the black support at the back of the unit.


What are the connections for the WESTERMO SDW-532-MM-SC2-SM-SC15?

The connections for the WESTERMO SDW-532-MM-SC2-SM-SC15 are:

  • Network RJ-45 connection (Ports 1, 2, 3)
  • Power connection
  • Network Fibre connection (Ports 4, 5)

For the WESTERMO SDW-532-MM-SC2-SM-SC15 specifically:

  • Port 4: SC Single mode 15 km connector
  • Port 5: SC Multi mode 2 km connector