What safety precautions should be followed before installing the WESTERMO SDW-541-SM-LC40?
Before installation of the WESTERMO SDW-541-SM-LC40:
Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit.
This unit should only be installed by qualified personnel.
This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only.
The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations.
This unit uses convection cooling. To avoid obstructing the air flow around the unit, follow the spacing recommendations (see Installation section).
What safety precautions should be followed before mounting, using, or removing the WESTERMO SDW-541-SM-LC40?
Before mounting, using or removing the WESTERMO SDW-541-SM-LC40:
Prevent access to hazardous voltage by disconnecting the unit from power supply.
Warning! Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply.
What is the warning regarding the Class 1 Laser Product in the WESTERMO SDW-541-SM-LC40?
Do not look directly into fibre optical fibre port or any connected fibre although this unit is designed to meet the Class 1 Laser regulations.
What care recommendations should be followed to maintain the full operation of the WESTERMO SDW-541-SM-LC40 and fulfill warranty obligations?
Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations.
This unit must not be operating with removed covers or lids.
Do not attempt to disassemble the unit. There are no user serviceable parts inside.
Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards.
Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.
Do not paint the unit. Paint can clog the unit and prevent proper operation.
Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels.
Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged.
Fibre connectors are supplied with plugs to avoid contamination inside the optical port. As long as no optical fibre is mounted on the connector, e.g. for storage, service or transportation, should the plug be applied.
What special treatment is required when handling fibre optic equipment for the WESTERMO SDW-541-SM-LC40?
Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If the fibre will be disconnected from the modem the protective hood on the transmitter/receiver must be connected. The protective hood must be kept on during transportation. The fibre optic cable must also be handle the same way.
If this recommendation not will be followed it can jeopardise the warranty.
How should the optical connectors of the WESTERMO SDW-541-SM-LC40 be cleaned if contaminated?
In the event of contamination, the optical connectors should be cleaned by the use of forced nitrogen and some kind of cleaning stick.
Recommended cleaning fluids:
• Methyl-, ethyl-, isopropyl- or isobutyl-alcohol
• Hexane
• Naphtha
What maintenance is required for the WESTERMO SDW-541-SM-LC40?
No maintenance is required, as long as the unit is used as intended within the specified conditions.
What is the required product disposal procedure for the WESTERMO SDW-541-SM-LC40?
This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it. It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment.
By ensuring this product is disposed of correctly, you will help to reduce hazardous substances and prevent potential negative consequences to both environment and human health, which could be caused by inappropriate disposal.
What is the description for the WESTERMO SDW-541-SM-LC40 based on its article number 3644-0025?
The article number is 3644-0025. The model is SDW-541-SM-LC40. The description is 10/100Base-T/TX: 4 ports 100Base-FX: 1 port.
What are the Isolation between interfaces specifications for the WESTERMO SDW-541-SM-LC40?
| Isolation between interfaces | |
| Power Interface to all other | 2.8 kV DC 2.0 kV RMS @ 50 Hz and 60 s duration |
| TX signal Interface to all other | 2.1 kV DC 1.5 kV RMS @ 50 Hz and 60 s duration |
| TX shield Interface to all other | 1.5 kV DC 1.0 kV RMS @ 50 Hz and 60 s duration |
What are the Environmental conditions specifications for the WESTERMO SDW-541-SM-LC40?
| Environmental | |
| Temperature, operating | -25 to +65°C (SDW-541) |
| Temperature, storage and transportation | -25 to +70°C |
| Relative humidity, operating | 5 to 95% (non-condensing) |
| Relative humidity, storage and transportation | 5 to 95% (condensation allowed outside packaging) |
| Altitude, operating | 2000 m/70 kPa |
What are the Mechanical specifications for the WESTERMO SDW-541-SM-LC40?
| Mechanical | |
| Dimension (W x H x D) | 35 x 121 x 119 mm |
| Weight | 0.2 kg |
| Mounting | DIN-rail |
| Degree of protection | IP21 |
How is the WESTERMO SDW-541-SM-LC40 configured?
The WESTERMO SDW-541-SM-LC40 is Auto configured (auto-negotiation) or has manual setting of speed and duplex of individual TX port, by DIP-switches.
Port mirror function is possible to set with DIP-switch. With the port mirror function active the switch will copy all outgoing traffic to port 1. This can be used to monitor all traffic going out from the switch. Packets may be discarded if the total throughput exceeds the port speed of port 1.
What are the Fibre optic power budget specifications for the WESTERMO SDW-541-SM-LC40 (Singlemode SM-LC40)?
| Model | Singlemode SM-LC40 |
| Transmitted wavelength | 1310 nm |
| Min. output power, transmitter | -5 dBm |
| Max. output power, transmitter | 0 dBm |
| Input sensitivity, receiver | -34 dBm |
| Min. power budget | 29 dBm |
| Max. power budget | 34 dBm |
| Recommended fibre cable and core / cladding diameter | 9/125 |
| 10/125 |
What is the Normal attenuation in connectors / splices for the WESTERMO SDW-541-SM-LC40?
| Type | Normal attenuation |
| Connector | 0.2 – 0.4 dBm |
| Fusion splice | 0.1 dBm |
| Mechanical splice | 0.2 dBm |
What is the Rated current for the WESTERMO SDW-541-SM-LC40 (SDW-541-SM-LC40 model)?
The rated current for the WESTERMO SDW-541-SM-LC40 (@12VDC power input) is 350 mA.
What are the Power specifications for the WESTERMO SDW-541-SM-LC40?
| Power SDW-500 series | |
| Rated voltage | 12–48 VDC, polarity protected |
| Operating voltage | 9.6–57.6 VDC |
| Rated frequency | DC |
| Connection | Detachable screw terminal |
| Connector size | 0.2–2.5 mm² (AWG 24-12) |
What are the Ethernet TX interface specifications for the WESTERMO SDW-541-SM-LC40?
| Ethernet TX | |
| Electrical specification | IEEE std 802.3. 2000 edition |
| Data rate | 10 Mbit/s or 100 Mbit/s, manual or auto |
| Duplex | Full or half, manual or auto |
| Connection | SC, ST or LC |
| Circuit type | Optical |
| Transmission range | 100 m |
What are the Ethernet FX interface specifications for the WESTERMO SDW-541-SM-LC40?
| Ethernet FX | |
| Electrical specification | IEEE std 802.3. 2000 edition |
| Data rate | 10 Mbit/s or 100 Mbit/s, manual or auto |
| Duplex | Full or half, manual or auto |
| Connection | SC, ST or LC |
| Circuit type | Optical |
| Transmission range | 100 m |
How does the WESTERMO SDW-541-SM-LC40 support redundant power connection?
The WESTERMO SDW-541-SM-LC40 supports redundant power connection. The positive inputs are +VA and +VB, and the negative input for both supplies is COM. The power is drawn from the input with the highest voltage.
What are the pin descriptions for the 3-pos screw terminal power connection on the WESTERMO SDW-541-SM-LC40?
| 3-pos screw terminal | Description | Power |
| 1 | COM | 0V |
| 2 | +VA | A: 9.6 – 57.6 VDC |
| 3 | +VB | B: 9.6 – 57.6 VDC |
What is the Ethernet TX connection type and crossover capability on the WESTERMO SDW-541-SM-LC40?
The Ethernet TX connection is an RJ-45 connector, with automatic MDI/MDI-X crossover.
What are the contact signal names and descriptions for the Ethernet TX connection on the WESTERMO SDW-541-SM-LC40?
| Contact | Signal Name | Direction | Description/Remark |
| 1 | TD+ | In/Out | Transmitted/Received data |
| 2 | TD− | In/Out | Transmitted/Received data |
| 3 | RD+ | In/Out | Transmitted/Received data |
| 4 | − | − | − |
| 5 | − | − | − |
| 6 | RD− | In/Out | Transmitted/Received data |
| 7 | − | − | − |
| 8 | − | − | − |
| Shield | − | − | HF-connected |
What type of cable is recommended for the Ethernet TX connection on the WESTERMO SDW-541-SM-LC40?
CAT 5 cable is recommended. Unshielded (UTP) or shielded (STP) connector might be used.
What is the specification for FX LC Multi- or single mode (optional) on the WESTERMO SDW-541-SM-LC40?
Ethernet FX connection.
1300 nm singlemode fibre transceiver with LC-connector.
The dust protection plug shall be mounted when no fibre is connected.
What is the status indication of the PWR LED on the WESTERMO SDW-541-SM-LC40?
| LED | Status | Indication of |
| PWR | ON | Internal power, initialising OK |
| Slow flash | Initialisation progressing | |
| Fast flash | Initialisation error |
What is the status indication of the LINK LED on the WESTERMO SDW-541-SM-LC40?
| LED | Status | Indication of |
| LINK | OFF | No Ethernet link |
| ON | Good Ethernet link | |
| Flash | Ethernet data is transmitted or received, traffic indication |
What is the status indication of the SPD LED (TX only) on the WESTERMO SDW-541-SM-LC40?
| LED | Status | Indication of |
| SPD (TX only) | OFF | 10 Mbit/s |
| ON | 100 Mbit/s |
What is the status indication of the DPX LED (TX only) on the WESTERMO SDW-541-SM-LC40?
| LED | Status | Indication of |
| DPX (TX only) | OFF | Half duplex |
| ON | Full duplex |
Where are the DIP-switches located on the WESTERMO SDW-541-SM-LC40 and what are they used for?
DIP-switches are accessible under the lid on top of the unit. DIP-switches are used to configure the unit.
What is an important note regarding DIP-switch configuration on the WESTERMO SDW-541-SM-LC40?
When configuration via DIP-switches, the settings of DIP-switches configure the unit only after a reboot (power off/on).
What precautions must be observed when configuring the DIP-switches on the WESTERMO SDW-541-SM-LC40?
To be observe when the DIP-switches will be configured:
Speed and duplex setting only valid when auto-negotiation is disabled.
When monitoring selected all outgoing packets from the switch is also copied to the port 1.
Speed and duplex switch settings are ignored for FX ports.
If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X configuration.
How do I set Port 1 settings for Auto-negotiation and auto MDI/MDI-X disabled on the WESTERMO SDW-541-SM-LC40?
Set S1 switches to:
ON
1 2 3 4 5 6 7 8
■ ■ ■ ■ ■ ■ ■ ■
How do I set Port 1 settings for Auto-negotiation and auto MDI/MDI-X enabled on the WESTERMO SDW-541-SM-LC40?
Set S1 switches to:
ON
■
1 2 3 4 5 6 7 8
How do I set Port 1 settings for 10 Mbit/s speed selected on the WESTERMO SDW-541-SM-LC40?
Set S1 switches to:
ON
■ ■
1 2 3 4 5 6 7 8
How do I set Port 1 settings for 100 Mbit/s speed selected on the WESTERMO SDW-541-SM-LC40?
Set S1 switches to:
ON
■
1 2 3 4 5 6 7 8
How do I set Port 1 settings for Half duplex selected on the WESTERMO SDW-541-SM-LC40?
Set S1 switches to:
ON
■ ■ ■
1 2 3 4 5 6 7 8
How do I set Port 1 settings for Full duplex selected on the WESTERMO SDW-541-SM-LC40?
Set S1 switches to:
ON
■ ■
1 2 3 4 5 6 7 8
How do I set Port 2 settings for Auto-negotiation and auto MDI/MDI-X disabled on the WESTERMO SDW-541-SM-LC40?
Set S1 switches to:
ON
■ ■ ■ ■ ■ ■ ■ ■
1 2 3 4 5 6 7 8
How do I set Port 2 settings for Auto-negotiation and auto MDI/MDI-X enabled on the WESTERMO SDW-541-SM-LC40?
Set S1 switches to:
ON
■
1 2 3 4 5 6 7 8
How do I set Port 2 settings for 10 Mbit/s speed selected on the WESTERMO SDW-541-SM-LC40?
Set S1 switches to:
ON
■ ■
1 2 3 4 5 6 7 8
How do I set Port 2 settings for 100 Mbit/s speed selected on the WESTERMO SDW-541-SM-LC40?
Set S1 switches to:
ON
■
1 2 3 4 5 6 7 8
How do I set Port 2 settings for Half duplex selected on the WESTERMO SDW-541-SM-LC40?
Set S1 switches to:
ON
■ ■ ■
1 2 3 4 5 6 7 8
How do I set Port 2 settings for Full duplex selected on the WESTERMO SDW-541-SM-LC40?
Set S1 switches to:
ON
■ ■
1 2 3 4 5 6 7 8
How do I set Port 3 settings for Auto-negotiation and auto MDI/MDI-X disabled on the WESTERMO SDW-541-SM-LC40?
Set S1 switches to:
ON
■ ■ ■ ■ ■ ■ ■ ■
1 2 3 4 5 6 7 8
How do I set Port 3 settings for Auto-negotiation and auto MDI/MDI-X enabled on the WESTERMO SDW-541-SM-LC40?
Set S1 switches to:
ON
■
1 2 3 4 5 6 7 8
How do I set Port 3 settings for 10 Mbit/s speed selected on the WESTERMO SDW-541-SM-LC40?
Set S1 switches to:
ON
■ ■
1 2 3 4 5 6 7 8
How do I set Port 3 settings for 100 Mbit/s speed selected on the WESTERMO SDW-541-SM-LC40?
Set S1 switches to:
ON
■
1 2 3 4 5 6 7 8
How do I set Port 3 settings for Half duplex selected on the WESTERMO SDW-541-SM-LC40?
Set S2 switches to:
ON
■ ■ ■
1 2 3 4 5 6 7 8
How do I set Port 3 settings for Full duplex selected on the WESTERMO SDW-541-SM-LC40?
Set S2 switches to:
ON
■ ■
1 2 3 4 5 6 7 8
How do I set Port 4 settings for Auto-negotiation and auto MDI/MDI-X disabled on the WESTERMO SDW-541-SM-LC40?
Set S2 switches to:
ON
■ ■ ■ ■ ■
1 2 3 4 5
How do I set Port 4 settings for Auto-negotiation and auto MDI/MDI-X enabled on the WESTERMO SDW-541-SM-LC40?
Set S2 switches to:
ON
■
1 2 3 4 5
How do I set Port 4 settings for 10 Mbit/s speed selected on the WESTERMO SDW-541-SM-LC40?
Set S2 switches to:
ON
■ ■
1 2 3 4 5
How do I set Port 4 settings for 100 Mbit/s speed selected on the WESTERMO SDW-541-SM-LC40?
Set S2 switches to:
ON
■
1 2 3 4 5
How do I set Port 4 settings for Half duplex selected on the WESTERMO SDW-541-SM-LC40?
Set S2 switches to:
ON
■ ■ ■
1 2 3 4 5
How do I set Port 4 settings for Full duplex selected on the WESTERMO SDW-541-SM-LC40?
Set S2 switches to:
ON
■ ■
1 2 3 4 5
How do I set Port mirroring settings for No monitoring selected on the WESTERMO SDW-541-SM-LC40?
Set S2 switches to:
ON
■ ■ ■ ■ ■
1 2 3 4 5
How do I set Port mirroring settings for Monitoring selected on the WESTERMO SDW-541-SM-LC40?
Set S2 switches to:
ON
■
1 2 3 4 5
How do I set Factory settings on the WESTERMO SDW-541-SM-LC40?
Set S1 switches to:
ON
■ ■ ■ ■ ■ ■ ■
1 2 3 4 5 6 7 8
Set S2 switches to:
ON
■ ■ ■ ■ ■
1 2 3 4 5
How should the WESTERMO SDW-541-SM-LC40 be mounted?
This unit should be mounted on 35 mm DIN-rail which is horizontally mounted on a wall or cabinet backplate.
This unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules. Recommended spacing 25 mm (1.0 inch) above/below and 10 mm (0.4 inches) left/right the unit.
Snap on mounting.
How is the WESTERMO SDW-541-SM-LC40 removed?
Press down the black support at the back of the unit.