Free English WESTERMO SDW-550 E-MARK (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD WESTERMO SDW-550 E-MARK (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.


How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.


What are the safety precautions to take before installing the WESTERMO SDW-550 E-MARK?

Before installation of the WESTERMO SDW-550 E-MARK, read the manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit.

This unit should only be installed by qualified personnel.

This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only.

The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations.

This unit uses convection cooling. To avoid obstructing the air flow around the unit, follow the spacing recommendations (see Installation section).


What safety precautions should be taken before mounting, using, or removing the WESTERMO SDW-550 E-MARK?

Prevent access to hazardous voltage by disconnecting the unit from power supply. Warning! Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply.


What should be known about the fibre optical port on the WESTERMO SDW-550 E-MARK?

Do not look directly into fibre optical fibre port or any connected fibre although this unit is designed to meet the Class 1 Laser regulations.


What are the care recommendations for the WESTERMO SDW-550 E-MARK to maintain full operation and fulfil warranty obligations?

Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations.

This unit must not be operating with removed covers or lids.

Do not attempt to disassemble the unit. There are no user serviceable parts inside.

Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards.

Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.

Do not paint the unit. Paint can clog the unit and prevent proper operation.

Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels.

Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged.

If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support.

Fibre connectors are supplied with plugs to avoid contamination inside the optical port. As long as no optical fibre is mounted on the connector, e.g. for storage, service or transportation, should the plug be applied.


What special treatment is needed for fibre optic handling with the WESTERMO SDW-550 E-MARK?

Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If the fibre will be disconnected from the modem the protective hood on the transmitter/receiver must be connected. The protective hood must be kept on during transportation.

The fibre optic cable must also be handle the same way.

If this recommendation not will be followed it can jeopardise the warranty.


How should the optical connectors of the WESTERMO SDW-550 E-MARK be cleaned in the event of contamination?

In the event of contamination, the optical connectors should be cleaned by the use of forced nitrogen and some kind of cleaning stick.

Recommended cleaning fluids:

  • Methyl-, ethyl-, isopropyl- or isobutyl-alcohol
  • Hexane
  • Naphtha

Is maintenance required for the WESTERMO SDW-550 E-MARK?

No maintenance is required, as long as the unit is used as intended within the specified conditions.


What does the product disposal symbol on the WESTERMO SDW-550 E-MARK mean?

This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it. It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment.

By ensuring this product is disposed of correctly, you will help to reduce hazardous substances and prevent potential negative consequences to both environment and human health, which could be caused by inappropriate disposal.


What are the environmental conditions for the WESTERMO SDW-550 E-MARK?

The operating temperature for the WESTERMO SDW-550 E-MARK is -25 to +70°C.

The temperature for storage and transportation is -25 to +70°C.

The relative humidity for operating is 5 to 95% (non-condensing).

The relative humidity for storage and transportation is 5 to 95% (condensation allowed outside packaging).

The altitude for operating is 2000 m/70 kPa.


What are the isolation specifications between interfaces for the WESTERMO SDW-550 E-MARK?

The isolation between interfaces for the WESTERMO SDW-550 E-MARK are:

Power Interface to all other 2.8 kV DC 2.0 kV RMS @ 50 Hz and 60 s duration
TX signal Interface to all other 2.1 kV DC 1.5 kV RMS @ 50 Hz and 60 s duration
TX shield Interface to all other 1.5 kV DC 1.0 kV RMS @ 50 Hz and 60 s duration

What are the mechanical specifications for the WESTERMO SDW-550 E-MARK?

The mechanical specifications for the WESTERMO SDW-550 E-MARK are:

Dimension (W x H x D) 35 x 121 x 119 mm
Weight 0.2 kg
Mounting DIN-rail
Degree of protection IP21

How is the configuration set for the TX ports on the WESTERMO SDW-550 E-MARK?

TX ports on the WESTERMO SDW-550 E-MARK are Auto configured (auto-negotiation) or manually setting of speed and duplex of individual TX port, by DIP-switches.


What is the function of the port mirror feature on the WESTERMO SDW-550 E-MARK?

The port mirror function is possible to set with DIP-switch. With the port mirror function active the switch will copy all outgoing traffic to port 1. This can be used to monitor all traffic going out from the switch. Packets may be discarded if the total throughput exceeds the port speed of port 1.


What are the fibre optic power budget specifications for models similar to the WESTERMO SDW-550 E-MARK that use Multimode MM-xx2?

The fibre optic power budget specifications for models similar to the WESTERMO SDW-550 E-MARK using Multimode MM-xx2 are:

MM-xx2
Transmitted wavelength 1310 nm
Min. output power, transmitter -19 dBm
Max. output power, transmitter -12 dBm
Input sensitivity, receiver -31 dBm
Min. power budget 12 dBm
Max. power budget 19 dBm
Recommended fibre cable and core / cladding diameter 50/125 62.5/125

What are the fibre optic power budget specifications for models similar to the WESTERMO SDW-550 E-MARK that use Singlemode SM-SC15?

The fibre optic power budget specifications for models similar to the WESTERMO SDW-550 E-MARK using Singlemode SM-SC15 are:

Singlemode SM-SC15
Transmitted wavelength 1310 nm
Min. output power, transmitter -15 dBm
Max. output power, transmitter -8 dBm
Input sensitivity, receiver -34 dBm
Min. power budget 19 dBm
Max. power budget 26 dBm
Recommended fibre cable and core / cladding diameter 9/125 10/125

What are the fibre optic power budget specifications for models similar to the WESTERMO SDW-550 E-MARK that use Singlemode SM-LC15?

The fibre optic power budget specifications for models similar to the WESTERMO SDW-550 E-MARK using Singlemode SM-LC15 are:

Singlemode SM-LC15
Transmitted wavelength 1310 nm
Min. output power, transmitter -15 dBm
Max. output power, transmitter -8 dBm
Input sensitivity, receiver -31 dBm
Min. power budget 16 dBm
Max. power budget 23 dBm
Recommended fibre cable and core / cladding diameter 9/125 10/125

What are the fibre optic power budget specifications for models similar to the WESTERMO SDW-550 E-MARK that use Singlemode SM-LC40?

The fibre optic power budget specifications for models similar to the WESTERMO SDW-550 E-MARK using Singlemode SM-LC40 are:

Singlemode SM-LC40
Transmitted wavelength 1310 nm
Min. output power, transmitter -5 dBm
Max. output power, transmitter 0 dBm
Input sensitivity, receiver -34 dBm
Min. power budget 29 dBm
Max. power budget 34 dBm
Recommended fibre cable and core / cladding diameter 9/125 10/125

What is the normal attenuation in connectors and splices for the WESTERMO SDW-550 E-MARK fibre optic connections?

The normal attenuation in connectors and splices for the WESTERMO SDW-550 E-MARK fibre optic connections are:

Type Normal attenuation
Connector 0.2 – 0.4 dBm
Fusion splice 0.1 dBm
Mechanical splice 0.2 dBm

What are the key features of the WESTERMO SDW-550 E-MARK?

The features of the WESTERMO SDW-550 E-MARK include:

  • TX shields individually isolated
  • Wide DC power range 12 – 48 VDC
  • Wide temperature range
  • Automatic MDI/MDI-X crossover
  • LED indicators for Power, Speed, Duplex, Link and Traffic
  • Port monitoring
  • 35 mm DIN rail mounting
  • Enable or disable of flow control

What are some example applications for the WESTERMO SDW-550 E-MARK?

Example applications for the WESTERMO SDW-550 E-MARK are:

  • 5-port switch
  • Ethernet isolator, for STP networks

What is the rated voltage and operating voltage for the Power on the WESTERMO SDW-500 series?

The rated voltage for the Power on the WESTERMO SDW-500 series is 12-48 VDC, polarity protected.

The operating voltage is 9.6 – 57.6 VDC.


What is the rated current for the WESTERMO SDW-550 E-MARK when the DC power input is 12VDC?

The rated current for the WESTERMO SDW-550 E-MARK @12VDC power input is 320 mA.


What are the electrical specifications for the Ethernet TX on the WESTERMO SDW-500 series?

The electrical specifications for the Ethernet TX on the WESTERMO SDW-500 series are:

Electrical specification IEEE std 802.3. 2000 edition
Data rate 10 Mbit/s or 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Connection SC, ST or LC
Circuit type Optical
Transmission range 100 m

What are the electrical specifications for the Ethernet FX on the WESTERMO SDW-500 series?

The electrical specifications for the Ethernet FX on the WESTERMO SDW-500 series are:

Electrical specification IEEE std 802.3. 2000 edition
Data rate 10 Mbit/s or 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Connection SC, ST or LC
Circuit type Optical
Transmission range 100 m

How is the power connected to the WESTERMO SDW-500 series?

The SDW-500 series supports redundant power connection. The positive inputs are +VA and +VB, the negative input for both supplies are COM. The power is drawn from the input with the highest voltage.

The 3-pos screw terminal connections for Power are:

3-pos screw terminal Description Power
1 COM 0V
2 +VA A: 9.6 – 57.6 VDC
3 +VB B: 9.6 – 57.6 VDC

What is the pinout for the Ethernet TX connection (RJ-45 connector) on the WESTERMO SDW-500 series?

The pinout for the Ethernet TX connection (RJ-45 connector) on the WESTERMO SDW-500 series, which supports automatic MDI/MDI-X crossover, is:

Contact Signal Name Direction Description/Remark
1 TD+ In/Out Transmitted/Received data
2 TD- In/Out Transmitted/Received data
3 RD+ In/Out Transmitted/Received data
4
5
6 RD- In/Out Transmitted/Received data
7
8
Shield HF-connected

CAT 5 cable is recommended. Unshielded (UTP) or shielded (STP) connector might be used.


What are the LED indications for the WESTERMO SDW-550 E-MARK?

The LED indicators for the WESTERMO SDW-550 E-MARK are:

LED Status Indication of
PWR ON Internal power, initialising OK
Slow flash Initialisation progressing
Fast flash Initialisation error
LINK OFF No Ethernet link
ON Good Ethernet link
Flash Ethernet data is transmitted or received, traffic indication
SPD (TX only) OFF 10 Mbit/s
ON 100 Mbit/s
DPX (TX only) OFF Half duplex
ON Full duplex

At power on the PWR flashes during initialising. LINK (LINK) of every port. Speed (SPD) and duplex (DPX) of TX ports.


What should be observed when configuring the DIP-switches for the WESTERMO SDW-550 E-MARK?

To be observed when the DIP-switches will be configured for the WESTERMO SDW-550 E-MARK:

  • Speed and duplex setting only valid when auto-negotiation is disabled.
  • When monitoring selected all outgoing packets from the switch is also copied to the port 1.
  • Speed and duplex switch settings are ignored for FX ports.
  • If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X configuration.

What are the DIP switch settings for Port 1 on the WESTERMO SDW-550 E-MARK?

The DIP switch settings for Port 1 on the WESTERMO SDW-550 E-MARK are:

  • S1 (switches 1-8): ON for Auto-negotiation and auto MDI/MDI-X disabled.
  • S1 (switches 1-8): ON for Auto-negotiation and auto MDI/MDI-X enabled.
  • S1 (switches 1-8): ON for 10 Mbit/s speed selected.
  • S1 (switches 1-8): ON for 100 Mbit/s speed selected.
  • S1 (switches 1-8): ON for Half duplex selected.
  • S1, S2 (switches 1-8): ON for Full duplex selected.

What are the DIP switch settings for Port 2 on the WESTERMO SDW-550 E-MARK?

The DIP switch settings for Port 2 on the WESTERMO SDW-550 E-MARK are:

  • S1 (switches 1-8): ON for Auto-negotiation and auto MDI/MDI-X disabled.
  • S1 (switches 1-8): ON for Auto-negotiation and auto MDI/MDI-X enabled.
  • S1 (switches 1-8): ON for 10 Mbit/s speed selected.
  • S1 (switches 1-8): ON for 100 Mbit/s speed selected.
  • S1 (switches 1-8): ON for Half duplex selected.
  • S1, S2 (switches 1-8): ON for Full duplex selected.

What are the DIP switch settings for Port 3 on the WESTERMO SDW-550 E-MARK?

The DIP switch settings for Port 3 on the WESTERMO SDW-550 E-MARK are:

  • S1 (switches 1-8): ON for Auto-negotiation and auto MDI/MDI-X disabled.
  • S1 (switches 1-8): ON for Auto-negotiation and auto MDI/MDI-X enabled.
  • S1 (switches 1-8): ON for 10 Mbit/s speed selected.
  • S1 (switches 1-8): ON for 100 Mbit/s speed selected.
  • S2 (switches 1-8): ON for Half duplex selected.
  • S2 (switches 1-8): ON for Full duplex selected.

What are the DIP switch settings for Port mirroring on the WESTERMO SDW-550 E-MARK?

The DIP switch settings for Port mirroring on the WESTERMO SDW-550 E-MARK are:

  • S2 (switches 1-8): ON for No monitoring selected.
  • S2 (switches 1-8): ON for Monitoring selected.

What are the DIP switch settings for Flow control on the WESTERMO SDW-550 E-MARK?

The DIP switch settings for Flow control on the WESTERMO SDW-550 E-MARK are:

  • S3 (switches 1-4): ON for Flow control selected.
  • S3 (switches 1-4): ON for No flow control selected.

What are the factory settings for the DIP switches on the WESTERMO SDW-550 E-MARK?

The factory settings for the DIP switches on the WESTERMO SDW-550 E-MARK are:

  • S1 (switches 1-8): ON
  • S2 (switches 1-8): ON
  • S3 (switches 1-4): ON

What is the procedure for mounting the WESTERMO SDW-550 E-MARK on a DIN-rail?

To mount the WESTERMO SDW-550 E-MARK on a DIN-rail:

Snap on mounting, see figure. To avoid obstructing the airflow around the unit, use the following spacing rules. Recommended spacing 25 mm (1.0 inch) above/below and 10 mm (0.4 inches) left/right the unit.

* Spacing (left/right) recommended for full operating temperature range.


How is the WESTERMO SDW-550 E-MARK removed from a DIN-rail?

To remove the WESTERMO SDW-550 E-MARK, press down the black support at the back of the unit, see figure.