What care recommendations should be followed for the WESTERMO SDW-532-SM-LC40?
Follow the care recommendations below to maintain full operation of the WESTERMO SDW-532-SM-LC40 and to fulfil the warranty obligations.
This unit must not be operating with removed covers or lids.
Do not attempt to disassemble the unit. There are no user serviceable parts inside.
Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards.
Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.
Do not paint the unit. Paint can clog the unit and prevent proper operation.
Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels.
Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged.
If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support.
Fibre connectors are supplied with plugs to avoid contamination inside the optical port. As long as no optical fibre is mounted on the connector, e.g. for storage, service or transportation, should the plug be applied.
How should I handle fibre optic equipment related to the WESTERMO SDW-532-SM-LC40?
Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If the fibre will be disconnected from the modem the protective hood on the transmitter/receiver must be connected. The protective hood must be kept on during transportation. The fibre optic cable must also be handle the same way.
If this recommendation is not followed it can jeopardise the warranty.
How should the optical connectors of the WESTERMO SDW-532-SM-LC40 be cleaned?
In the event of contamination, the optical connectors should be cleaned by the use of forced nitrogen and some kind of cleaning stick.
Recommended cleaning fluids:
- Methyl-, ethyl-, isopropyl- or isobutyl-alcohol
- Hexane
- Naphtha
Does the WESTERMO SDW-532-SM-LC40 require maintenance?
No maintenance is required, as long as the WESTERMO SDW-532-SM-LC40 is used as intended within the specified conditions.
What are the environmental conditions for the WESTERMO SDW-532-SM-LC40?
Environmental conditions for the WESTERMO SDW-532-SM-LC40:
| Environmental | |
|---|---|
| Temperature, operating | -25 to +60°C (SDW-532) |
| Temperature, storage and transportation | -25 to +70°C |
| Relative humidity, operating | 5 to 95% (non-condensing) |
| Relative humidity, storage and transportation | 5 to 95% (condensation allowed outside packaging) |
| Altitude, operating | 2000 m/70 kPa |
What are the mechanical specifications for the WESTERMO SDW-532-SM-LC40?
Mechanical specifications for the WESTERMO SDW-532-SM-LC40:
| Mechanical | |
|---|---|
| Dimension (W x H x D) | 35 x 121 x 119 mm |
| Weight | 0.2 kg |
| Mounting | DIN-rail |
| Degree of protection | IP21 |
How is the WESTERMO SDW-532-SM-LC40 configured?
The WESTERMO SDW-532-SM-LC40 is Auto configured (auto-negotiation) or manually setting of speed and duplex of individual TX port, by DIP-switches.
Port mirror function is possible to set with DIP-switch. With the port mirror function active the switch will copy all outgoing traffic to port 1. This can be used to monitor all traffic going out from the switch. Packets may be discarded if the total throughput exceeds the port speed of port 1.
What is the fibre optic power budget for the WESTERMO SDW-532-SM-LC40?
Fibre optic power budget for the WESTERMO SDW-532-SM-LC40 (SM-LC40):
| Model | Singlemode SM-LC40 |
|---|---|
| Transmitted wavelength | 1310 nm |
| Min. output power, transmitter | -5 dBm |
| Max. output power, transmitter | 0 dBm |
| Input sensitivity, receiver | -34 dBm |
| Min. power budget | 29 dBm |
| Max. power budget | 34 dBm |
| Recommended fibre cable and core / cladding diameter | 9/125 10/125 |
What is the attenuation in connectors / splices for the WESTERMO SDW-532-SM-LC40?
Attenuation in connectors / splices for the WESTERMO SDW-532-SM-LC40:
| Type | Normal attenuation |
|---|---|
| Connector | 0.2 – 0.4 dBm |
| Fusion splice | 0.1 dBm |
| Mechanical splice | 0.2 dBm |
What is the description of the WESTERMO SDW-532-SM-LC40?
The SDW-550 (part of the SDW-500 series) is an Industrial Ethernet 5-port switch. All ports support auto-negotiation, but DIP-switches also allow speed and duplex configuration of any individual TX port. It is also possible to set up one port to monitor traffic to/from the switch. The SDW-550 has been designed to meet high industrial specifications, providing very high dependability in harsh environmental conditions.
What are the features of the WESTERMO SDW-532-SM-LC40?
Features of the WESTERMO SDW-532-SM-LC40 (SDW-550 series):
- TX shields individually isolated
- Wide DC power range 12 – 48 VDC
- Wide temperature range
- Automatic MDI/MDI-X crossover
- LED indicators for Power, Speed, Duplex, Link and Traffic
- Port monitoring
- 35 mm DIN rail mounting
- Enable or disable of flow control
What are examples of applications for the WESTERMO SDW-532-SM-LC40?
Examples of applications for the WESTERMO SDW-532-SM-LC40 (SDW-500 series):
- 5-port switch
- Ethernet isolator, for STP networks
What are the power specifications for the WESTERMO SDW-532-SM-LC40?
Power specifications for the WESTERMO SDW-532-SM-LC40:
| Rated voltage | 12–48 VDC, polarity protected |
|---|---|
| Operating voltage | 9.6–57.6 VDC |
| Rated current @12VDC power input | 450 mA |
| Rated frequency | DC |
| Connection | Detachable screw terminal |
| Connector size | 0.2–2.5 mm² (AWG 24-12) |
What are the Ethernet TX interface specifications for the WESTERMO SDW-532-SM-LC40?
Ethernet TX interface specifications for the WESTERMO SDW-532-SM-LC40:
| Electrical specification | IEEE std 802.3. 2000 edition |
|---|---|
| Data rate | 10 Mbit/s or 100 Mbit/s, manual or auto |
| Duplex | Full or half, manual or auto |
| Connection | SC, ST or LC |
| Circuit type | Optical |
| Transmission range | 100 m |
What are the Ethernet FX interface specifications for the WESTERMO SDW-532-SM-LC40?
Ethernet FX interface specifications for the WESTERMO SDW-532-SM-LC40:
| Electrical specification | IEEE std 802.3. 2000 edition |
|---|---|
| Data rate | 10 Mbit/s or 100 Mbit/s, manual or auto |
| Duplex | Full or half, manual or auto |
| Connection | SC, ST or LC |
| Circuit type | Optical |
| Transmission range | 100 m |
How does the Power connection work on the WESTERMO SDW-532-SM-LC40?
The SDW-500 series, including the WESTERMO SDW-532-SM-LC40, supports redundant power connection. The positive inputs are +VA and +VB, and the negative input for both supplies is COM. The power is drawn from the input with the highest voltage.
The 3-pos screw terminal connections are:
| 3-pos screw terminal | Description | Power |
|---|---|---|
| 1 | COM | 0 V |
| 2 | +VA | A: 9.6 – 57.6 VDC |
| 3 | +VB | B: 9.6 – 57.6 VDC |
What are the specifications for the Ethernet TX connection (RJ-45 connector) on the WESTERMO SDW-532-SM-LC40?
The Ethernet TX connection uses an RJ-45 connector and features automatic MDI/MDI-X crossover. CAT 5 cable is recommended. Unshielded (UTP) or shielded (STP) connector might be used.
Contact specifications:
| Contact | Signal Name | Direction | Description/Remark |
|---|---|---|---|
| 1 | TD+ | In/Out | Transmitted/Received data |
| 2 | TD- | In/Out | Transmitted/Received data |
| 3 | RD+ | In/Out | Transmitted/Received data |
| 4 | – | – | – |
| 5 | – | – | – |
| 6 | RD- | In/Out | Transmitted/Received data |
| 7 | – | – | – |
| 8 | – | – | – |
| Shield | – | – | HF-connected |
What are the specifications for the FX LC Multi- or single mode (optional) Ethernet connection on the WESTERMO SDW-532-SM-LC40?
FX LC Multi- or single mode (optional) Ethernet FX connection:
1300 nm singlemode fibre transceiver with LC-connector.
The dust protection plug shall be mounted when no fibre is connected.
What do the LED indicators on the WESTERMO SDW-532-SM-LC40 signify?
At power on the PWR flashes during initialising.
Indicators (LED):
- Power (PWR)
- Link (LINK) of every port
- Speed (SPD) and duplex (DPX) of TX ports
| LED | Status | Indication of |
|---|---|---|
| PWR | ON | Internal power, initialising OK |
| Slow flash | Initialisation progressing | |
| Fast flash | Initialisation error | |
| LINK | OFF | No Ethernet link |
| ON | Good Ethernet link | |
| Flash | Ethernet data is transmitted or received, traffic indication | |
| SPD (TX only) | OFF | 10 Mbit/s |
| ON | 100 Mbit/s | |
| DPX (TX only) | OFF | Half duplex |
| ON | Full duplex |
How are the DIP-switches accessed and used for configuration on the WESTERMO SDW-532-SM-LC40?
DIP-switches are accessible under the lid on top of the unit. DIP-switches are used to configure the unit. When configuration via DIP-switches, the settings of DIP-switches configure the unit only after a reboot (power off/on).
What should be observed when configuring the DIP-switches on the WESTERMO SDW-532-SM-LC40?
- Speed and duplex setting only valid when auto-negotiation is disabled.
- When monitoring selected all outgoing packets from the switch is also copied to the port 1.
- Speed and duplex switch settings are ignored for FX ports.
- If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X configuration.
What are the DIP switch settings for Port 1 on the WESTERMO SDW-532-SM-LC40 (SDW-532)?
Port 1 settings (S1 DIP-switch bank):
Auto-negotiation and auto MDI/MDI-X disabled:
ON
☐☐☐☐☐☐☐☐
1 2 3 4 5 6 7 8
Auto-negotiation and auto MDI/MDI-X enabled:
ON
■☐☐☐☐☐☐☐
1 2 3 4 5 6 7 8
10 Mbit/s speed selected:
ON
☐■☐☐☐☐☐☐
1 2 3 4 5 6 7 8
100 Mbit/s speed selected:
ON
■■☐☐☐☐☐☐
1 2 3 4 5 6 7 8
Half duplex selected:
ON
☐☐■☐☐☐☐☐
1 2 3 4 5 6 7 8
Full duplex selected:
ON
■☐■☐☐☐☐☐
1 2 3 4 5 6 7 8
What are the DIP switch settings for Port 2 on the WESTERMO SDW-532-SM-LC40 (SDW-532)?
Port 2 settings (S1 DIP-switch bank):
Auto-negotiation and auto MDI/MDI-X disabled:
ON
☐☐☐☐☐☐☐☐
1 2 3 4 5 6 7 8
Auto-negotiation and auto MDI/MDI-X enabled:
ON
■☐☐☐☐☐☐☐
1 2 3 4 5 6 7 8
10 Mbit/s speed selected:
ON
☐■☐☐☐☐☐☐
1 2 3 4 5 6 7 8
100 Mbit/s speed selected:
ON
■■☐☐☐☐☐☐
1 2 3 4 5 6 7 8
Half duplex selected:
ON
☐☐■☐☐☐☐☐
1 2 3 4 5 6 7 8
Full duplex selected:
ON
■☐■☐☐☐☐☐
1 2 3 4 5 6 7 8
What are the DIP switch settings for Port 3 on the WESTERMO SDW-532-SM-LC40 (SDW-532)?
Port 3 settings (S1 and S2 DIP-switch banks):
Auto-negotiation and auto MDI/MDI-X disabled (S1):
ON
☐☐☐☐☐☐☐☐
1 2 3 4 5 6 7 8
Auto-negotiation and auto MDI/MDI-X enabled (S1):
ON
■☐☐☐☐☐☐☐
1 2 3 4 5 6 7 8
10 Mbit/s speed selected (S1):
ON
☐■☐☐☐☐☐☐
1 2 3 4 5 6 7 8
100 Mbit/s speed selected (S1):
ON
■■☐☐☐☐☐☐
1 2 3 4 5 6 7 8
Half duplex selected (S2):
ON
☐☐☐☐☐☐☐☐
1 2 3 4 5 6 7 8
Full duplex selected (S2):
ON
■☐☐☐☐☐☐☐
1 2 3 4 5 6 7 8
What are the DIP switch settings for Port 5 on the WESTERMO SDW-532-SM-LC40 (SDW-550)?
Port 5 settings (S2 DIP-switch bank – applies to SDW-550):
Auto-negotiation and auto MDI/MDI-X disabled:
ON
☐☐☐☐☐☐☐☐
1 2 3 4 5 6 7 8
Auto-negotiation and auto MDI/MDI-X enabled:
ON
■☐☐☐☐☐☐☐
1 2 3 4 5 6 7 8
10 Mbit/s speed selected:
ON
☐■☐☐☐☐☐☐
1 2 3 4 5 6 7 8
100 Mbit/s speed selected:
ON
■■☐☐☐☐☐☐
1 2 3 4 5 6 7 8
Half duplex selected:
ON
☐☐■☐☐☐☐☐
1 2 3 4 5 6 7 8
Full duplex selected:
ON
■☐■☐☐☐☐☐
1 2 3 4 5 6 7 8
What are the DIP switch settings for Port mirroring on the WESTERMO SDW-532-SM-LC40 (SDW-550)?
Port mirroring settings (S2 DIP-switch bank – applies to SDW-550):
No monitoring selected:
ON
☐☐☐☐☐☐☐☐
1 2 3 4 5 6 7 8
Monitoring selected:
ON
☐☐☐■☐☐☐☐
1 2 3 4 5 6 7 8
What are the DIP switch settings for Flow control on the WESTERMO SDW-532-SM-LC40 (SDW-550)?
Flow control settings (S3 DIP-switch bank – applies to SDW-550):
Flow control selected:
ON
☐☐☐☐
1 2 3 4
No flow control selected:
ON
■☐☐☐
1 2 3 4
What are the Factory DIP switch settings for the WESTERMO SDW-532-SM-LC40 (SDW-550)?
Factory settings (applies to SDW-550):
S1:
ON
■☐■☐☐☐☐☐
1 2 3 4 5 6 7 8
S2:
ON
■☐■☐☐☐☐☐
1 2 3 4 5 6 7 8
S3:
ON
■☐☐☐
1 2 3 4
What are the DIP switch settings for Port 4 on the WESTERMO SDW-532-SM-LC40 (SDW-541)?
Port 4 settings (S2 DIP-switch bank – applies to SDW-541):
Auto-negotiation and auto MDI/MDI-X disabled:
ON
☐☐☐☐☐
1 2 3 4 5
Auto-negotiation and auto MDI/MDI-X enabled:
ON
■☐☐☐☐
1 2 3 4 5
10 Mbit/s speed selected:
ON
☐■☐☐☐
1 2 3 4 5
100 Mbit/s speed selected:
ON
■■☐☐☐
1 2 3 4 5
Half duplex selected:
ON
☐☐■☐☐
1 2 3 4 5
Full duplex selected:
ON
■☐■☐☐
1 2 3 4 5
What are the DIP switch settings for Port mirroring on the WESTERMO SDW-532-SM-LC40 (SDW-541/SDW-532)?
Port mirroring settings (S2 DIP-switch bank – applies to SDW-541/SDW-532):
No monitoring selected:
ON
☐☐☐☐☐
1 2 3 4 5
Monitoring selected:
ON
☐☐☐■☐
1 2 3 4 5
What are the Factory DIP switch settings for the WESTERMO SDW-532-SM-LC40 (SDW-541/SDW-532)?
Factory settings (applies to SDW-541/SDW-532):
S1:
ON
■☐■☐☐☐☐☐
1 2 3 4 5 6 7 8
S2:
ON
■☐■☐☐
1 2 3 4 5
How should the WESTERMO SDW-532-SM-LC40 be mounted?
This unit should be mounted on 35 mm DIN-rail which is horizontally mounted on a wall or cabinet backplate. This unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules. Recommended spacing 25 mm (1.0 inch) above/below and 10 mm (0.4 inches) left/right the unit.
Snap on mounting is used.
How is the WESTERMO SDW-532-SM-LC40 removed?
Press down the black support at the back of the unit.