What safety precautions should be taken before installing the WESTERMO SDW-532-SM-LC15?

Before installation:

Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit.

This unit should only be installed by qualified personnel.

This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only.

The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations.

This unit uses convection cooling. To avoid obstructing the air flow around the unit, follow the spacing recommendations (see Installation section).


What safety precautions should be taken before mounting, using, or removing the WESTERMO SDW-532-SM-LC15?

Prevent access to hazardous voltage by disconnecting the unit from power supply.

Warning! Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply.


What is the safety information regarding the Class 1 Laser Product in the WESTERMO SDW-532-SM-LC15?

Do not look directly into fibre optical fibre port or any connected fibre although this unit is designed to meet the Class 1 Laser regulations.


What care recommendations should be followed to maintain full operation of the WESTERMO SDW-532-SM-LC15?

Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations.

This unit must not be operating with removed covers or lids.

Do not attempt to disassemble the unit. There are no user serviceable parts inside.

Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards.

Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.

Do not paint the unit. Paint can clog the unit and prevent proper operation.

Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels.

Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged.

Fibre connectors are supplied with plugs to avoid contamination inside the optical port. As long as no optical fibre is mounted on the connector, e.g. for storage, service or transportation, should the plug be applied.


What special treatment is required for Fibre Optic Handling with the WESTERMO SDW-532-SM-LC15?

Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If the fibre will be disconnected from the modem the protective hood on the transmitter/receiver must be connected. The protective hood must be kept on during transportation. The fibre optic cable must also be handle the same way.

If this recommendation not will be followed it can jeopardise the warranty.


How should optical connectors for the WESTERMO SDW-532-SM-LC15 be cleaned if contaminated?

In the event of contamination, the optical connectors should be cleaned by the use of forced nitrogen and some kind of cleaning stick.

Recommended cleaning fluids:

  • Methyl-, ethyl-, isopropyl- or isobutyl-alcohol
  • Hexane
  • Naphtha

What are the maintenance requirements for the WESTERMO SDW-532-SM-LC15?

No maintenance is required, as long as the unit is used as intended within the specified conditions.


What is the product disposal information for the WESTERMO SDW-532-SM-LC15?

This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it. It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment.

By ensuring this product is disposed of correctly, you will help to reduce hazardous substances and prevent potential negative consequences to both environment and human health, which could be caused by inappropriate disposal.


What are the environmental conditions for the WESTERMO SDW-532-SM-LC15?

Isolation between interfaces
Power Interface to all other 2.8 kV DC 2.0 kV RMS @ 50 Hz and 60 s duration
TX signal Interface to all other 2.1 kV DC 1.5 kV RMS @ 50 Hz and 60 s duration
TX shield Interface to all other 1.5 kV DC 1.0 kV RMS @ 50 Hz and 60 s duration
Environmental
Temperature, operating -25 to +60°C (SDW-532)
Temperature, storage and transportation -25 to +70°C
Relative humidity, operating 5 to 95% (non-condensing)
Relative humidity, storage and transportation 5 to 95% (condensation allowed outside packaging)
Altitude, operating 2000 m/70 kPa

What are the mechanical specifications for the WESTERMO SDW-532-SM-LC15?

Mechanical
Dimension (W x H x D) 35 x 121 x 119 mm
Weight 0.2 kg
Mounting DIN-rail
Degree of protection IP21

How is the WESTERMO SDW-532-SM-LC15 configured?

Auto configured (auto-negotiation) or manually setting of speed and duplex of individual TX port, by DIP-switches.

Port mirror function is possible to set with DIP-switch. With the port mirror function active the switch will copy all outgoing traffic to port 1. This can be used to monitor all traffic going out from the switch. Packets may be discarded if the total throughput exceeds the port speed of port 1.


What is the fibre optic power budget for the WESTERMO SDW-532-SM-LC15?

The WESTERMO SDW-532-SM-LC15 model is a Singlemode SM-LC15. The power budget is as follows:

Model Singlemode SM-LC15
Transmitted wavelength 1310 nm
Min. output power, transmitter -15 dBm
Max. output power, transmitter -8 dBm
Input sensitivity, receiver -31 dBm
Min. power budget 16 dBm
Max. power budget 23 dBm
Recommended fibre cable and core / cladding diameter 9/125

10/125


What is the normal attenuation in connectors and splices for the WESTERMO SDW-532-SM-LC15?

Type Normal attenuation
Connector 0.2 – 0.4 dBm
Fusion splice 0.1 dBm
Mechanical splice 0.2 dBm

What are the power interface specifications for the WESTERMO SDW-532-SM-LC15?

Power SDW-500 series
Rated voltage 12–48 VDC, polarity protected
Operating voltage 9.6–57.6 VDC
Rated current @12VDC power input
SDW-532-SM-LC15 450 mA
Rated frequency DC
Connection Detachable screw terminal
Connector size 0.2 – 2.5 mm² (AWG 24-12)

What are the Ethernet TX interface specifications for the WESTERMO SDW-532-SM-LC15?

Ethernet TX
Electrical specification IEEE std 802.3. 2000 edition
Data rate 10 Mbit/s or 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Connection SC, ST or LC
Circuit type Optical
Transmission range 100 m

What are the Ethernet FX interface specifications for the WESTERMO SDW-532-SM-LC15?

Ethernet FX
Electrical specification IEEE std 802.3. 2000 edition
Data rate 10 Mbit/s or 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Connection SC, ST or LC
Circuit type Optical
Transmission range 100 m

How are the positive and negative power inputs for the WESTERMO SDW-532-SM-LC15 connected?

The WESTERMO SDW-532-SM-LC15 supports redundant power connection. The positive inputs are +VA and +VB, and the negative input for both supplies is COM. The power is drawn from the input with the highest voltage.

3-pos screw terminal Description Power
1 COM 0V
2 +VA A: 9.6 – 57.6 VDC
3 +VB B: 9.6 – 57.6 VDC

What are the signal names, directions, and descriptions for the Ethernet TX connection (RJ-45) on the WESTERMO SDW-532-SM-LC15?

Ethernet TX connection (RJ-45 connector), automatic MDI/MDI-X crossover. CAT 5 cable is recommended. Unshielded (UTP) or shielded (STP) connector might be used.

Contact Signal Name Direction Description/Remark
1 TD+ In/Out Transmitted/Received data
2 TD- In/Out Transmitted/Received data
3 RD+ In/Out Transmitted/Received data
4
5
6 RD- In/Out Transmitted/Received data
7
8
Shield HF-connected

What are the specifications for FX LC Multi- or single mode connectivity on the WESTERMO SDW-532-SM-LC15?

Ethernet FX connection.

1300 nm singlemode fibre transceiver with LC-connector.

The dust protection plug shall be mounted when no fibre is connected.


What do the LED indicators on the WESTERMO SDW-532-SM-LC15 signify?

At power on the PWR flashes during initialising. Indicators include Power (PWR), Link (LINK) of every port, and Speed (SPD) and duplex (DPX) of TX ports.

LED Status Indication of
PWR ON Internal power, initialising OK
Slow flash Initialisation progressing
Fast flash Initialisation error
LINK OFF No Ethernet link
ON Good Ethernet link
Flash Ethernet data is transmitted or received, traffic indication
SPD (TX only) OFF 10 Mbit/s
ON 100 Mbit/s
DPX (TX only) OFF Half duplex
ON Full duplex

Where are the DIP-switches located on the WESTERMO SDW-532-SM-LC15, and what must be observed when configuring them?

DIP-switches are accessible under the lid on top of the unit. DIP-switches are used to configure the unit.

Warning! Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap), before the lid on top/front of the unit is removed.

Warning! Do not open connected equipment. Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections.

NOTE: When configuration via DIP-switches, the settings of DIP-switches configure the unit only after a reboot (power off/on).

To be observe when the DIP-switches will be configured:

Speed and duplex setting only valid when auto-negotiation is disabled.

When monitoring selected all outgoing packets from the switch is also copied to the port 1.

Speed and duplex switch settings are ignored for FX ports.

If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X configuration.


What are the DIP switch settings for Port 1 on the WESTERMO SDW-532-SM-LC15?

Port 1 settings (S1 DIP-switch):

Auto-negotiation and auto MDI/MDI-X disabled:

ON

☐☐☐☐☐☐☐☐

1 2 3 4 5 6 7 8

Auto-negotiation and auto MDI/MDI-X enabled:

ON

■☐☐☐☐☐☐☐

1 2 3 4 5 6 7 8

10 Mbit/s speed selected:

ON

☐■☐☐☐☐☐☐

1 2 3 4 5 6 7 8

100 Mbit/s speed selected:

ON

■■☐☐☐☐☐☐

1 2 3 4 5 6 7 8

Half duplex selected:

ON

☐☐■☐☐☐☐☐

1 2 3 4 5 6 7 8

Full duplex selected:

ON

■☐■☐☐☐☐☐

1 2 3 4 5 6 7 8


What are the DIP switch settings for Port 2 on the WESTERMO SDW-532-SM-LC15?

Port 2 settings (S1 DIP-switch):

Auto-negotiation and auto MDI/MDI-X disabled:

ON

☐☐☐☐☐☐☐☐

1 2 3 4 5 6 7 8

Auto-negotiation and auto MDI/MDI-X enabled:

ON

☐☐☐■☐☐☐☐

1 2 3 4 5 6 7 8

10 Mbit/s speed selected:

ON

☐☐☐☐■☐☐☐

1 2 3 4 5 6 7 8

100 Mbit/s speed selected:

ON

☐☐☐■■☐☐☐

1 2 3 4 5 6 7 8

Half duplex selected:

ON

☐☐☐☐☐■☐☐

1 2 3 4 5 6 7 8

Full duplex selected:

ON

☐☐☐■☐■☐☐

1 2 3 4 5 6 7 8


What are the DIP switch settings for Port 3 on the WESTERMO SDW-532-SM-LC15?

Port 3 settings (S1 and S2 DIP-switches):

Auto-negotiation and auto MDI/MDI-X disabled (S1):

ON

☐☐☐☐☐☐☐☐

1 2 3 4 5 6 7 8

Auto-negotiation and auto MDI/MDI-X enabled (S1):

ON

☐☐☐☐☐☐☐■

1 2 3 4 5 6 7 8

10 Mbit/s speed selected (S1):

ON

☐☐☐☐☐☐■☐

1 2 3 4 5 6 7 8

100 Mbit/s speed selected (S1):

ON

☐☐☐☐☐☐■■

1 2 3 4 5 6 7 8

Half duplex selected (S2):

ON

■☐☐☐☐☐☐☐

1 2 3 4 5 6 7 8

Full duplex selected (S2):

ON

☐■☐☐☐☐☐☐

1 2 3 4 5 6 7 8


What are the DIP switch settings for Port mirroring on the WESTERMO SDW-532-SM-LC15?

Port mirroring settings (S2 DIP-switch):

No monitoring selected:

ON

☐☐☐☐☐☐☐☐

1 2 3 4 5 6 7 8

Monitoring selected:

ON

☐☐☐☐■☐☐☐

1 2 3 4 5 6 7 8


What are the DIP switch settings for Flow control on the WESTERMO SDW-532-SM-LC15?

Flow control settings (S3 DIP-switch):

Flow control selected:

ON

■☐☐☐

1 2 3 4

No flow control selected:

ON

☐■☐☐

1 2 3 4


What are the Factory DIP switch settings for the WESTERMO SDW-532-SM-LC15?

Factory settings:

S1:

ON

■☐■☐■☐■☐

1 2 3 4 5 6 7 8

S2:

ON

☐■☐■☐■☐■

1 2 3 4 5 6 7 8

S3:

ON

■☐☐☐

1 2 3 4


How is the WESTERMO SDW-532-SM-LC15 mounted?

This unit should be mounted on 35 mm DIN-rail which is horizontally mounted on a wall or cabinet backplate.

This unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules. Recommended spacing 25 mm (1.0 inch) above/below and 10 mm (0.4 inches) left/right the unit.

Snap on mounting.


How is the WESTERMO SDW-532-SM-LC15 removed?

Press down the black support at the back of the unit.