What are the safety warnings for installing and using the TCL TCD125D1HWH-DV air conditioner?

Failure to observe a warning may result in death, injury, or damage to the equipment. Please follow these warnings:

• Ask your Dealer or qualified personnel to carry out installation work. Do not try to install the machine yourself, as improper installation may result in water leakage, electric shock, or fire.

• Perform installation work in accordance with the installation manual. Improper installation may result in water leakage, electrical shock, or fire.

• Be sure to use only the specified accessories and parts for installation work. Failure to use specified parts may result in water leakage, electric shock, fire, or the unit failing.

• Install the conditioner on a structure strong enough to withstand the weight of the unit. An insufficient structure may result in the equipment falling and causing injuries.

• Carry out the specified installation work after considering strong winds, typhoons, or earthquakes. Improper installation work may result in the equipment falling and causing accidents.

• Ensure a separate power supply circuit is provided and all electrical work is carried out by qualified personnel according to local laws, regulations, and this installation manual. An insufficient power supply or improper electrical construction may lead to electric shocks or fire.

• Make sure all wiring is secured, the specified wires are used, and no external forces act on the terminal connection or wires. Improper connections or installation may result in fire.

• When wiring, position wires so that the switch box cover can be securely fastened. Improper positioning may result in electric shock, fire, or the terminals overheating.

• If refrigerant gas leaks during installation, ventilate the area immediately.

• After completing installation, check that the refrigerant gas does not leak. Fire may occur if leaked refrigerant contacts an ignition source.

• Before accessing terminals and electrical parts, all supply circuits must be disconnected.

• Do not install the indoor unit or remote controller where they may be exposed to rain or moisture. Water or other fluids on electrical components may result in fire or electric shock.

• Grounding is necessary. Earth the air conditioner. Do not connect the earth wire to gas or water pipes, a lightning conductor, or a telephone ground wire. Improper earthing may result in electric shock.

• Be sure to install an earth leakage breaker. Failure to do so may result in electric shock.


What safety cautions should be observed when installing the TCL TCD125D1HWH-DV air conditioner?

Failure to observe a caution may result in injury or damage to the equipment. Please adhere to the following cautions:

• Do not install the indoor unit or wired controller where flammable gases may leak, where there are carbon fibers or ignitable dust, or where volatile flammables like thinner or gasoline are handled.

• Do not install the indoor unit or wired controller where the area is filled with steam or the ground is always wet. Insulation of electric components may be damaged, resulting in electric shock.

• Be sure to only use refrigerant piping approved for use with R32 refrigerant. Unapproved piping may result in an explosive rupture.

• When making piping connections, do not let air or other substances other than the specified refrigerant enter the refrigeration cycle. This can cause lower capacity, abnormally high pressure, explosion, and injury.

• The appliance is not for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience, unless supervised or instructed.

• Children should be supervised to not play with the appliance.

• The appliance must be installed according to national wiring regulations.

• This appliance can be used by children aged 8 and above and persons with reduced capabilities if they have been given supervision or instruction.

• Children shall not play with the appliance. Cleaning and user maintenance shall not be done by children without supervision.


What are the specific instructions for servicing the TCL TCD125D1HWH-DV with R32 refrigerant?

1. Check this manual for the dimensions of space needed for proper installation, including minimum distances to adjacent structures.

2. The appliance must be installed, operated, and stored in a room with a floor area larger than 4m².

3. Installation of pipe-work shall be kept to a minimum.

4. Pipe-work must be protected from physical damage and not installed in an unventilated space if the space is smaller than 4m².

5. Compliance with national gas regulations must be observed.

6. Mechanical connections must be accessible for maintenance.

7. Follow instructions for handling, installing, cleaning, maintaining, and disposing of the refrigerant.

8. Ensure ventilation openings are clear of obstruction.

9. Servicing shall be performed only as recommended by the manufacturer.

10. **Warning:** The appliance must be stored in a well-ventilated area where the room size corresponds to the room area specified for operation.

11. **Warning:** The appliance must be stored in a room without continuously operating open flames (e.g., an operating gas appliance) and ignition sources (e.g., an operating electric heater).

12. The appliance must be stored to prevent mechanical damage.

13. Anyone working on a refrigerant circuit should hold a valid certificate from an accredited assessment authority, recognizing their competence to handle refrigerants.

14. Every working procedure that affects safety must only be carried out by competent persons.

15. **Warning:**

– Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.

– The appliance must be stored in a room without continuously operating ignition sources.

– Do not pierce or burn.

– Be aware that refrigerants may not contain an odor.


What checks are necessary before beginning work on a TCL TCD125D1HWH-DV system containing flammable R32 refrigerant?

Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure the risk of ignition is minimized. For repair to the refrigerating system, the following precautions must be complied with:

1. **Work procedure:** Work shall be undertaken under a controlled procedure to minimize the risk of a flammable gas or vapor being present.

2. **General work area:** All maintenance staff and others in the local area must be instructed on the nature of the work. Avoid work in confined spaces. The area around the workspace must be sectioned off and made safe by controlling flammable material.

3. **Checking for presence of refrigerant:** The area must be checked with an appropriate refrigerant detector before and during work to ensure the technician is aware of potentially flammable atmospheres. The leak detection equipment must be suitable for use with flammable refrigerants (non-sparking, adequately sealed, or intrinsically safe).

4. **Presence of fire extinguisher:** If hot work is conducted, appropriate fire extinguishing equipment (dry powder or CO2) must be available.

5. **No ignition sources:** No person working on a refrigeration system shall use any sources of ignition that may lead to fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away. “No Smoking” signs must be displayed.

6. **Ventilated area:** Ensure the area is in the open or adequately ventilated before breaking into the system or conducting hot work. Ventilation must continue during the work period to safely disperse any released refrigerant.

7. **Checks to the refrigeration equipment:** When changing electrical components, they must be fit for the purpose and to the correct specification. Always follow the manufacturer’s maintenance and service guidelines.

8. **Checks to electrical devices:** Repair and maintenance to electrical components must include initial safety checks and component inspection procedures. If a fault that could compromise safety exists, no electrical supply should be connected until it is resolved. Initial safety checks include ensuring capacitors are discharged safely, no live electrical components are exposed, and there is continuity of earth bonding.


What is the required minimum room area for installing the TCL TCD125D1HWH-DV?

The installation of your TCL TCD125D1HWH-DV, which uses R32 refrigerant, must be in a room larger than the minimum construction area. This area is determined by the total refrigerant charging quantity (factory charge + additional charge). Please refer to the following table to determine the minimum required area for your ceiling-type unit.
Minimum Room Area for Ceiling Type Unit
R32 refrigerant Weight (kg) Area (m²)
<1.224
1.224 0.956
1.4 1.25
1.6 1.63
1.8 2.07
2.0 2.55
2.2 3.09
2.4 3.68
2.6 4.31
2.8 5.00
3.0 5.74
3.2 6.54
3.4 7.38
3.6 8.27
3.8 9.22
4.0 10.2
4.2 11.3
4.4 12.4
4.6 13.5
4.8 14.7
5.0 16.0
5.2 17.3
5.4 18.6
5.6 20.0
5.8 21.5
6.0 23.0
6.2 24.5
6.4 26.1
6.6 27.8
6.8 29.5
7.0 31.3
7.2 33.1
7.4 34.9
7.6 36.9
7.8 38.8
8.0 40.8

Where is the best location to install the indoor unit of the TCL TCD125D1HWH-DV?

Select a location for the indoor unit that meets the following criteria:

1. A place with sufficient space for repair in a hung ceiling that can bear the weight of the machine.

2. A place where the air inlet and outlet are not hindered and are without influence from outdoor air.

3. A place without heat sources like smoke, fire, or toxic pollution.

4. A place where airflow can be transmitted everywhere in the room.

5. A place convenient for installation.


Where is the best location to install the outdoor unit of the TCL TCD125D1HWH-DV?

Select a location for the outdoor unit that meets the following criteria:

1. A place with sufficient space for installation and repair.

2. A place where the air inlet and outlet are not hindered, without strong airflow.

3. A dry and ventilated place.

4. A place where the overhanging is level and can bear the weight of the outdoor unit, without much noise.

5. A place where neighbors are not annoyed by noise and exhausted air.

6. A place without leakage of flammable gas.

7. A place convenient for installation.

Caution: Avoid locations that may cause malfunction, such as:

• Places with flammable gas leakage.

• Areas with salty air (near the coast).

• Areas with caustic gas (like sulfide) in the air.

• Places that cannot bear the weight of the machine.

• Kitchens full of oil gas.

• Areas with strong electromagnetic waves.

• Places where acid or alkaline liquid is evaporating.

• Areas where air circulation is not enough.

• Other special surroundings.


What accessories are included with the TCL TCD125D1HWH-DV?

Please check that the following accessories are included with your TCL TCD125D1HWH-DV unit.
Model Name Quantity
TCD100 / TCD125 / TCD140 / TCD160 Hose Clamp 1
Drain Hose 1
Installation Manual 1
Operation Manual 1
Hanger Bracket Accessories Pack 1
Pipe Insulation 2
Wired Controller 1
Wired controller connection cable 1

What items should I check after completing the installation of my TCL TCD125D1HWH-DV?

After installation is finished, take special care to check the following items to ensure proper operation and safety.
Items to be checked If not properly done, what is likely to occur
Is the gas leak test finished? It may result in insufficient cooling or heating.
Does the unit require external insulation? Condensate water may drip.
Does drainage flow smoothly? Condensate water may drip.
Does the power supply voltage correspond to that shown on the name plate? The unit may malfunction or the components burn out.
Is the wiring and piping correct? The unit may malfunction or the components burn out.
Is the unit safely grounded? Dangerous during electric leakage.
Is the wiring size according to specification? The unit may malfunction or the components burn out.
Is something blocking the air outlet or inlet of either the indoor or outdoor units? It may result in insufficient cooling or heating.
Are refrigerant piping length and additional refrigerant charge noted down? The refrigerant charge in the system is not clear.
Is the indoor unit positioned so that it is not in contact with parts of the ceiling? Vibration and noise can be transmitted into building.
Is the airflow within specification? Poor performance or malfunction.
Is an air filter installed in the return air? Blocked heat exchanger causing malfunction or compressor failure.
Is an external drain tray installed? Condensate water may drip.
Check and confirm that there are no R32 leak after the installation. (Not specified)

Also, at completion, ensure you have shown the customer how to operate the system using the operation manual, reviewed the safety considerations, and handed the operation manual to the customer.


How do I perform refrigerant piping work for the TCL TCD125D1HWH-DV?

All refrigerant piping work must only be carried out by a qualified person. Where additional refrigerant is required, use only R32.

CAUTION:

• Avoid introducing air or other contaminants into the piping. If contaminants remain, the system will malfunction.

• Carry out sufficient ventilation if refrigerant gas leaks during installation.

• Use both a spanner and a torque wrench when connecting or disconnecting pipes.

• Use only a flaring block suitable for R32 tube.

• When connecting the flare nut, coat only the flare’s inner surface with ether or ester oil. Initially tighten by hand for 3 to 4 turns before firmly tightening.

• Use the flare nuts included with the indoor unit.

• Refer to the tables below for flare dimensions, proper tightening torque, and tightening angles (if a torque wrench is not available).

Table 2: Tightening Torque and Flare Dimensions
Pipe size Tightening torque Flare dimensions A (mm)
6.4 (1/4″) 14.2-17.2 N·m (144-175 kgf·cm) 8.6-9.0
9.5 (3/8″) 32.7-39.9 N·m (333-407 kgf·cm) 12.6-13.0
12.7 (1/2″) 49.5-60.3 N·m (504-614 kgf·cm) 15.8-16.2
15.9 (5/8″) 61.8-75.4 N·m (630-770 kgf·cm) 19.3-19.7

Not recommended but in case of an emergency (without a torque wrench):

As you tighten the flare nut with a spanner, there is a point where the tightening torque suddenly increases. From that position, further tighten the flare nut using the angle shown below. After finishing, check for gas leaks.

Table 3: Further Tightening Angle
Pipe size Further tightening angle Recommended arm length of tool
6.4 (1/4″) 60 to 90 degrees Approx. 150mm
9.5 (3/8″) 60 to 90 degrees Approx. 200mm
12.7 (1/2″) 30 to 60 degrees Approx. 250mm
15.9 (5/8″) 30 to 60 degrees Approx. 300mm

CAUTION: Be sure to insulate local piping all the way into the pipe connections inside the machine. Exposed piping may cause condensation or burns on contact.


How do I perform drain piping work for the TCL TCD125D1HWH-DV?

WARNING: Improperly installed drain piping may result in water leaks and eventually wet furniture and belongings. After the piping work is finished, check that the drainage flows smoothly by pouring approximately 1 litre of water gradually into the drain tray.

CAUTION: For units with water pumps, you can choose between pump drainage (Fig10 ①) or natural drainage (Fig10 ②).

• If pump drainage is selected, the “Tray Drain Outlet” (②) must be blocked with the “Drain Plug”.

• If natural drainage is chosen, remove the “Drain Plug” from the “Tray Drain Outlet” (②) and unplug the “CN14” pump terminal on the circuit board. Wrap the unplugged terminal wires with insulating tape and secure them in an empty space in the electrical box to prevent contact with other components.

For Units With a Pump:

• The drain pipe outlet can be raised up to 600mm above the ceiling.

• Keep the horizontal pipe length and offset within 100mm or less to avoid overflow from water backflow when the unit stops.

General Installation:

• Keep the drain pipe short and sloping downward at a gradient of at least 1/100 to prevent air pockets.

• Secure the pipe every 1 to 1.5m to prevent sagging.

• Use the provided drain hose and clamp. Tighten the clamp firmly.

• Insulate the metal clamp with a field-supplied sealing pad.

• Insulate the drain hose inside the building.

• As a safety measure, use a safety drain tray (field supplied) and drain it separately.

• Insulate the drain pipe to prevent condensate dripping in humid conditions.

• Do not connect the drain piping directly to sewage pipes. Drainage must conform to local plumbing regulations.


What are the electrical wiring specifications for the TCL TCD125D1HWH-DV?

All field-supplied parts, materials, and electric works must conform to local codes. Use copper wire only. All wiring must be performed by an authorized electrician.

Precautions for Wiring:

• Do not clamp wired controller cords together with wires connecting the units.

• Keep controller cords and connecting wires at least 50mm from other electric wires to avoid electrical noise.

• Use a round crimp-style terminal for connection to the power supply terminal block.

• Do not connect wires of different gauges to the same power supply terminal.

• After connecting wires, secure them with cable ties so no pressure is applied to the connections.

• Ensure the terminal box cover fits snugly without pinching any wires.

Wire Specifications and Fuse:

Indoor Unit Model Power Supply (V/Ph/Hz) Fuse Capacity (A) Circuit Breaker Capacity (A) Min. Sectional Area of Power Cord (mm²)
TCD71/85 220-240V 1~ 50Hz 8 10 0.75
TCD100/125 8 10 1.0
TCD140/160 8 10 1.5
Outdoor Unit Model Power Supply (V/Ph/Hz) Fuse Capacity (A) Circuit Breaker Capacity (A) Min. Sectional Area of Power Cord (mm²)
TCD71/85 220-240V 1~ 50Hz 30 32 2.5
TCD100/125 30 40 4
TCD140/160 30 40 4

How do I separate and reassemble the indoor unit of the TCL TCD125D1HWH-DV (TCD100/125/140/160 models)?

WARNING: Power should be disconnected and tagged off when performing this procedure on an already installed unit.

To Separate the Indoor Unit:

1. Carefully remove the Airbox compartment by removing the (4) M6 bolts.

2. Carefully remove the (1) thermistor cable (R1T) from its clamp.

3. Wrap the thermistor cable and place it neatly into the rubber bush next to the fan deck.

4. Carefully disconnect the fan motor wiring from the base panel located underneath the reactor box.

5. Remove the (5) tapping screws located above the fan deck flange.

6. Remove the (4) M6 bolts securing the fan deck to the base panel of the heat exchanger compartment.

7. Carefully separate the fan deck assembly from the base panel, taking care not to damage the fan motor wiring.

8. Carefully detach the fan deck.

To Reassemble the Indoor Unit:

9. Carefully place the fan deck back in position on the base panel.

10. Secure the fan deck onto the heat exchanger compartment with the (4) M6 bolts and (5) tapping screws for the top flange of the fan deck.

11. Place the thermistor cable (R1T) back to the side of the fan deck and secure it with the thermistor clamp. Ensure the tip of the thermistor is positioned horizontally opposite the fan casing.

12. Reconnect the fan motor connector back to the connector of the base panel.

13. Carefully place the fan deck compartment with (4) M6 bolts, taking care not to damage the fan motor wiring.


How do I operate the wired remote controller for the TCL TCD125D1HWH-DV?

Here are the explanations for the main buttons on your wired remote controller:

1. **[ON/OFF] button:** Press to turn the air conditioner on or off.

2. **[MODE] button:** Press to cycle through the running modes: AUTO -> COOL -> DRY -> FAN -> HEAT.

3. **[∧ / ∨] button:** Press ‘∧’ to increase and ‘∨’ to decrease the set temperature or time value.

4. **[FAN SPEED] button:** Press to cycle through fan speeds: Mute -> Low speed -> Medium-low speed -> Medium speed -> Medium-high speed -> High speed -> Turbo -> Auto speed.

5. **[UP-DOWN SWING]/[ENTER] button:** Press to activate or inactivate the upward-downward swing function. When setting a function, press this button to confirm the selection.

6. **[LEFT-RIGHT SWING]/[BACK] button:** Press to activate or inactivate the left-right swing function. When setting a function, press this button to return to the previous setting.

7. **[FUNCTION] button:** Press for function selection. The current function icon will blink. Use the ‘∧’ or ‘∨’ buttons to switch to the next function. If the icon is lit up permanently, the function is activated; otherwise, it is inactivated. Functions include SLEEP, I FEEL, HEALTH, ECO, GENTLE, SELF-CLEANING, 8H HEATING, and GENERATOR.


How do I adjust the parameter settings on the wired controller for my TCL TCD125D1HWH-DV?

1. Press the “FUNC.” button until the parameter setting icon blinks.

2. Press the “[ENTER]” button to access the parameter setting interface. The timer zone will blink and display the current device function code, and the temperature zone will display the corresponding parameter.

3. Use the “∧” and “∨” buttons to change the device function code.

4. Press “[ENTER]” to select the target function. The temperature zone will then blink.

5. Use the “∧” and “∨” buttons to change the function parameter.

6. Press “[ENTER]” for confirmation.

7. Press “[BACK]” to exit from the parameter setting.

The following parameters can be adjusted:

Device Function Code Device Function Device Function Parameter Remarks
P6 Degree Fahrenheit/Celsius display F-C C: Degree Celsius display
F: Degree Fahrenheit display
PA Ambient/set temperature display 00-01 00: Set temperature
01: Ambient temperature
PD Wired controller button Buzzer switch ON-OF ON: Buzzer on
OFF: Buzzer off
A8 Maximum backlight luminance 30~100 Percentage of maximum backlight luminance
B3 Dust full reminding ON-OF ON: Dust full reminding function on
OFF: Dust full reminding function off
B4 Clock display setting 12-24 12: 12-hour system display
24: 24-hour system display
BA Night quiet mode switch (on some models) ON-OF ON: Activate night quiet mode
OFF: Deactivate night quiet mode
BB Night quiet mode start time (on some models) 0-23 Start time selection
BC Night quiet mode end time (on some models) 0-23 End time selection

How do I set the Night Quiet Mode on my TCL TCD125D1HWH-DV?

You can set the Night Quiet Mode using the wired controller.

1. In the power on or off state, press and hold the “FAN” key and the “∨” key for 5-7 seconds to enter the parameter setting screen. The temperature display will show “01” and the time display will show a blinking “PO”.

2. Use the “∨” or “∧” keys to select the “bA” icon, which will blink.

3. Press the “[ENTER]” button. The “bA” will stop blinking, and the temperature display zone will blink.

4. Use the “∨” or “∧” buttons to select “ON” or “OF”, then press “[ENTER]” to enable or disable Night Quiet Mode.

5. After enabling, the “bA” will blink again. Use the “∨” or “∧” buttons to navigate to the “bb” icon (start time).

6. Press “[ENTER]”. The digital code in the temperature display zone will blink. Select a start time between “0” and “23”.

7. Press “[ENTER]” to confirm. Use the “∨” or “∧” buttons to navigate to the “bC” icon (end time).

8. Press “[ENTER]”. The digital code in the temperature display zone will blink. Select an end time between “0” and “23”.

9. Press “[ENTER]” to confirm. The “bC” icon will blink.

10. Press the “[BACK]” or “MODE” icon (or wait 5 seconds) to return to the normal display.

Notes:

• Night Quiet Mode is effective only in cooling or heating modes.

• It will activate at the selected start time and deactivate at the selected end time.

• The start and end times cannot be the same.

• Activating this mode may result in a slight reduction in capacity.


How do I manually set the static pressure and constant air volume on my TCL TCD125D1HWH-DV?

If the default static pressure (150 Pa) does not meet your installation duct requirements, you can adjust it using the wired controller.

1. In the power on or off state, press and hold the “FAN” key and the “∨” key for 5-7 seconds to enter the parameter setting screen.

2. Use the “∨” or “∧” keys to select the icon “PL”, which will blink.

3. Press the “[ENTER]” button. The “PL” will stop blinking, and the digital code in the temperature display zone will blink (default is “00”).

4. Use the “∨” or “∧” keys to select a number from “01” to “09” corresponding to the static pressure value you need.

5. Press the “[ENTER]” button to confirm. The “PL” icon will blink again.

6. Press the “[BACK]” or “MODE” icon (or wait 15 seconds) to return to the normal display.

Refer to the table below for the code and corresponding static pressure value.

Table 4: Static Pressure Settings via Wired Controller
Display code 00 01 02 03 04 05 06 07 08 09 10 11
Set definition current operating static pressure value is displayed on the light pane P1 (0Pa) P2 (25Pa) P3 (50Pa) P4 (75Pa) P5 (100Pa) P6 (125Pa) P7 (150Pa) P8 (175Pa) P9 (200Pa) current indoor unit free static function pressure setting

What are the dimensions of the outdoor unit for the TCL TCD125D1HWH-DV?

The dimensions for the various models are as follows:
MODEL A (Width) B (Height) C (Depth) D E F G
TCD71/85 910 804 607 421 391 380 378
TCD100/125 1010 858 660 494 462 440 436
TCD140/160 950 1339 600 409 375 354 352

When do I need to add or reduce refrigerant for my TCL TCD125D1HWH-DV?

The TCL TCD71~TCD160 models are pre-charged with refrigerant for 20 meters of connecting piping.

• **When the pipeline length exceeds 20 meters:** Additional refrigerant is required. The formula is:
Additional charge (kg) = {Main length (m) – 20(m)} × 0.03 (kg/m)

• **When the pipeline length is between 10m and 20m:** Refrigerant needs to be reduced for optimal performance. The formula is:
Refrigerant reduced (kg) = {20(m) – main length (m)} × 0.03 (kg/m)

• **When the pipeline length is between 5m and 10m:** Refrigerant needs to be reduced for optimal performance. The formula is:
Refrigerant reduced (kg) = {20(m) – main length (m)} × 0.03 (kg/m)

• **When the pipeline length is shorter than 5 meters:** The refrigerant shall be at the rated charge indicated on the nameplate for 5 meters of refrigerant pipeline.

Additional Charge per Meter of Pipe:

Model Additional charge for 1m pipe (R32)/g
TCD71/85 30
TCD100/125 30
TCD140/160 30

Pipe Length and Height Drop Limits:

TCD71/85 TCD100/125/140/160
Longest pipe (L) 50m 75m
Maximum height drop (H) 30m 30m

When the drop between indoor and outdoor units is longer than 10m, an oil return bend should be added every 6m if the outdoor unit is above the indoor unit.


What do the error codes on my TCL TCD125D1HWH-DV mean?

If the display panel or wired control displays an error code, please refer to the following table for its meaning.
Error Code Error Content Error Code Error Content
E0 Indoor and outdoor communication failure F1 Battery module failure
E1 Indoor ambient temperature sensor failure F2 Exhaust temperature sensor failure protection
E2 Indoor fancoil temperature sensor failure F3 Failure protection of outer tube temperature sensor
E3 Outdoor fancoil temperature sensor failure F4 Abnormal protection of refrigerant circulation
E4 Abnormal system malfunction(lack of fluorine) F5 PFC protection
E5 Model configuration error F6 Compressor missing/ reverse phase protection
E6 Indoor PG/DC fan failure F7 Module temperature protection
E7 Outdoor ambient temperature sensor failure F8 Abnormal commutation of four-way valve
E8 Outdoor exhaust temperature sensor failure F9 Module temperature sensor circuit malfunction
E9 Outdoor IPM module failure/compressor drive failure FA Compressor phase current detection fault
EA Outdoor current sensor failure Fb Cooling and heating overload protection limit / reduce frequency
Eb PCB and display screen communication Failure FC High power protection limit / reduce frequency
EC Outdoor modules Communication failure FE Module current (compressor phase current) protection limit / reduce frequency
EE Outdoor EEPROM fault FF Module temperature protection limit / reduce frequency
EF Outdoor DC fan failure FH Drive protection limit / reduce frequency
EH Outdoor suction sensor failure FP Anti condensation protection limit / reduce frequency
EP Outdoor compressor casing top failure FU Anti freezing protection limit / reduce frequency
EU Outdoor voltage sensor failure Fj Exhaust protection limit / reduce frequency
Ej Outdoor central coil temperature sensor failure Fn External AC current protection limit / reduce frequency
En Outdoor air pipe temperature sensor failure Fy Fluorine deficiency protection
Ey Outdoor liquid pipe temperature sensor failure H1 High pressure switch malfunction
PO IPM module protection H2 Low pressure switch malfunction
P1 Overvoltage and undervoltage protection bf TVOC sensor failure
P2 Overcurrent protection be PM2.5 sensor failure
P3 Other protections bj Humidity sensor failure
P4 Protection against excessive outdoor exhaust temperature bE CO₂ sensor malfunction
P5 Cooling protection against overcooling bd Fresh air fan failure
P6 Cooling and anti overheating protection d4 Water full protection failure
P7 Heating and anti overheating protection d5 Access control protection
P8 Protection against high or low outdoor temperature b5 Main fan drive communication fault
P9 Compressor drive protection (abnormal load) Fd Refrigerant sensor fault
PA Communication failure/mode conflict Hd Refrigerant leakage protection
FO Infrared human sensing sensor failure

My TCL TCD125D1HWH-DV won’t run. What should I check?

If your air conditioner fails to function normally, please check the following items before calling for maintenance:
Problem Cause Corrective measure
The air conditioner can’t run. If you turn off the unit and then immediately turn it on, the compressor will delay running for 3 minutes to protect it. Please wait for a while.
Wire connection is wrong. Connect wires according to the wiring diagram.
Fuse or circuit breaker is broken. Replace the fuse or switch on the circuit breaker.
Power failure. Restart after power is resumed.
Power plug is loose. Reinsert the power plug.
Wired controller has low battery. Replace the batteries.

My TCL TCD125D1HWH-DV has a bad cooling or heating effect. What could be the cause?

If you are experiencing poor cooling or heating performance, check the following possible causes and solutions:
Cause Corrective measure
Air inlet and outlet of indoor or outdoor units have been blocked. Clear the obstacles and keep the area for indoor and outdoor units well ventilated.
Improper temperature setting. Reset to a proper temperature.
Fan speed is too low. Reset to a proper fan speed.
Air flow direction is not right. Change the direction of air louvers.
Doors or windows are open. Close them.
Exposed under direct sunshine. Put on curtains or louvers in front of the windows.
Too many heat sources in the room. Remove unnecessary heat sources.
Filter is blocked or dirty. Send for a professional to clean the filter.
Air inlets or outlets of the units are blocked. Clear away obstacles that are blocking the air inlets and outlets of indoor and outdoor units.

Are these situations with my TCL TCD125D1HWH-DV considered failures?

The following situations are not operation failures and are part of the normal function of your air conditioner:
Phenomenon Time of occurrence Cause
Mist comes from the air conditioner. During operation. If the unit is running under high humidity, the wet air in the room will be quickly cooled down.
Water full protection During operation. When in cooling mode, if the water level is too high, the machine will shut down for protection. The water pump continues to draw water. After the water level drops, the machine returns to normal. This protection frequency is less than or equal to 3 times.
System switches to heating mode after defrosting. Post-defrosting. Defrosting process will generate some water, which will turn to water vapor.
The air conditioner is buzzing at the beginning of operation. Start of operation. The temperature controller will buzz when it starts. The noise will become weak after about 1 minute.
When the unit is turned on, it purrs. When system is just started. The refrigerant is not stable. After about 30 seconds, the purr of the unit becomes low.
Refrigerant brushing sound. About 20s after enabling heating mode or during defrost. This is the sound of the 4-way valve switching direction. It will disappear after the valve changes direction.
Hissing sound. When the unit is started, stopped, or during/after operation. This is the sound of gaseous refrigerant that stops flowing and the sound of the drainage system.
Crunching sound. During and after operation. Due to temperature change, the front panel and other components may swell, causing an abrasion sound.
Hissing sound. When turned on or suddenly stopped during operation or after defrosting. This is caused by refrigerant suddenly stopping or changing its flow direction.
Dust comes from the unit. When starting after being unused for a long time. Dust inside the indoor unit comes out with the air.
The air conditioner generates some smell. During operation. The room smell or the smell of cigarettes comes out through the indoor unit.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD TCL TCD125D1HWH-DV (02) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.