What are the main features of the PREMIUM PRF047XW?
| Feature | Description |
|---|---|
| Door | Integrated Foaming Door with painting sheet metal and simple, beautiful recessed handle. |
| Gasket seal for the door | Recessed door gasket seal, easy to be discharged and cleaned. |
| Hinge | Plastic material, simple and practically. |
| Accessory | One shelf and one drip tray inside. |
| Structure | Front, Left and right side shell compose to whole “U” shape shell, with aluminum internal tank with cotton ginning, and unitary plastic linear mouth. It has inside hidden evaporator and condenser, and unitary foaming insulation. |
What are the unit specifications for the PREMIUM PRF047XW?
| Specification | Value |
|---|---|
| Net Capacity (L) | 47 |
| Voltage (V) | 115 |
| Frequency (Hz) | 60 |
| Refrigerant | R134a |
| Refrigerant Amount (g) | 38g |
What safety precautions should be taken during maintenance or service of the PREMIUM PRF047XW?
To ensure safety during maintenance, you must obey the following basic attention:
1) During service:
• Pay attention to the flame or ignition nearby, particularly after welding using gas too. You must turn off the flame first, then you can do other maintenance work, because the refrigerant will produce toxic air when it touches flame, sparkle or a capacitor.
• Do not do the welding work in an airtight or bad air circulation room.
• When discharging the refrigerant, you must keep the room in a good air circulation condition.
• When cutting the suction pipe or discharging pipe of the compressor, pay attention to the surplus refrigerant and internal pressure in the cooling system pipe.
2) Unplug the unit:
• When you are ready to proceed with maintenance, you must first unplug the freezer to ensure safety.
3) Avoid electrical shock:
• Normally when proceeding with maintenance, you must open the power supply first. But if you must check the field wiring or a component of the unit with the power supply on, you must be very careful and not touch the live parts. If you find out the wiring is aged, please replace it in time.
4) Correct use of components:
• If a component is damaged and needs to be replaced, be sure to replace it with a component of the same model. Do not use other models or other brand components, and do not use a changed component.
5) Correct use of service tools:
• Ensure to use the appropriate service tool right. Otherwise it will cause bad electrical contact or loose fixing, and an incidence will happen.
6) Wiring connection:
• When re-connecting a cut wire, be sure to use a soldering method or terminal connection, and then wrap the connection point with insulation tape to ensure a good connection.
7) Insulation resistance measure:
• After completing the service and assembly, you must use a multi-meter to measure the insulation resistance. If it is greater than 1 million ohm, then you can plug in the unit.
8) Grounding test:
• After maintenance, use a multimeter to measure the grounding resistance to ensure the grounding resistance is less than 0.1 ohm.
9) Pay attention to children or infants nearby:
• When performing maintenance, don’t let a child or an infant be nearby.
10) Cleaning:
• After service, do the necessary cleaning work and tell the customer the necessary precautions.
Is there anything to note about the electrical diagram for the PREMIUM PRF047XW?
Please note, some units are without the RUNNING CAPACITOR marked in red color in the diagram, according to the used compressor model.
How does the cooling system in the PREMIUM PRF047XW work?
The refrigerant flows through the system in the following order:
1. Compressor
2. Condenser
3. Dry Filter
4. Capillary
5. Evaporator
6. Air Suction Pipe
7. Back to the Compressor
The arrows in the system diagram indicate the flowing direction of the refrigerant.
What are the main replaceable parts of the PREMIUM PRF047XW?
| No. | Parts Name | PRF047XW |
|---|---|---|
| 1 | Door | 1 |
| 2 | Hinge | 2 |
| 3 | Shelf | 1 |
| 4 | Freezer Cabinet | 1 |
| 5 | Thermostat cover | 1 |
| 6 | Compressor base | 1 |
| 7 | Condensate Water Drain cap | 1 |
| 8 | Fixing feet | 2 |
How do I replace the thermostat on my PREMIUM PRF047XW?
When replacing components, you must unplug the unit first for safety.
Unscrew the fixing screw of the thermostat box, remove the thermostat box, then remove the old thermostat. Install the new thermostat of the same model, and reinstall back the whole thermostat box with the same fixing screw.
How do I replace the PTC starter and overload protector on my PREMIUM PRF047XW?
When replacing components, you must unplug the unit first for safety.
Remove the clamp of the connecting terminal cover of the compressor and the terminal cover. Toward the vertical direction, remove the broken-down starter or overload protector, install back the new starter or overload protector, then fix back the terminal box cover and its clamp.
How do I replace the door gasket seal on my PREMIUM PRF047XW?
When replacing components, you must unplug the unit first for safety.
Remove the old door gasket seal from the groove of the door liner, then install the new gasket seal into the four sides of the groove. Install it as evenly as possible. Open and close the door several times to ensure that the door is sealed.
How do I replace the compressor on my PREMIUM PRF047XW?
When replacing components, you must unplug the unit first for safety.
(a) First, cut the welding point of the technical pipe of the compressor to discharge the refrigerant inside the cooling system. Then weld the old point to disconnect the pipe to the compressor, remove the compressor to replace with a new one. Pay attention to replace with a new refrigerant dry filter.
(b) Install the new compressor, weld the high pressure side and low pressure side pipe to the compressor, and check the system for leakage. After completing a vacuum on the cooling system, charge the correct amount of refrigerant into the system from the low pressure side pipe. After this, run the unit to check if the cooling performance is ok or not, then weld and close the technical pipe.
What should I do if there is no frost on the cabinet liner of my PREMIUM PRF047XW?
If there is no frost, you should perform leakage detecting.
A) If a leakage point is found, first cut off the low pressure pipe to discharge the remaining refrigerant in the system. Then clean the pipe, replace it with a new dry filter, and weld again. Recharge the refrigerant and perform leakage detection again.
B) If a leakage point cannot be found, cut off the low pressure pipe. If there is no refrigerant coming out, then recharge the refrigerant and perform leakage detection again. If there is refrigerant coming out, cut off the high pressure pipe (this means that compressor suction is normal) and charge the condenser pipe with pressurized nitrogen. If no air comes out at the low pressure side, it means the pipe is blocked; replace the blocked parts and clean the system pipe. If there is no air suction at the compressor low pressure side, cut off the high pressure pipe; this means the air compression of the compressor is not good, so please replace the compressor.
What should I do if there is a little frost on the surface of my PREMIUM PRF047XW?
First, perform leakage detection.
A) If the leakage point is confirmed, cut off the low pressure pipe. If a little refrigerant air spurts out, it means that the system leaks slowly at the leakage point. You should repair the welding of the cut pipe and the leakage point, and clean the system pipe with high pressure nitrogen. Replace the dry filter, and after completing this work, re-vacuum and recharge the refrigerant. Finally, perform leakage detection again.
B) If a large quantity of refrigerant spurts out, cut off the high pressure pipe to check if the suction of the compressor low pressure pipe is normal. If there is no suction or weak suction, it means there is not good compression, and you need to replace the compressor. If the suction is normal, then charge the clean and warm nitrogen to the condenser pipe. If you find the returned nitrogen from the low pressure side is not sufficient, it means the system pipe is clogged lightly; please replace the clogged parts and clean the pipe.
What should I check if there is no frost but there is condensate water on the cabinet liner of my PREMIUM PRF047XW?
Check the temperature of the high pressure side pipe and the compressor. You will find it is too high. Then check the low pressure pipe with frost. If this is the case, it means there is too much refrigerant in the system. Please recharge with the appropriate quantity of refrigerant once more.
What does it mean if my PREMIUM PRF047XW works discontinuously?
The unit working discontinuously may indicate that the system is clogged with ice. Please replace the dry filter and clean the system with clean and warm nitrogen.
What should I do if the compressor on my PREMIUM PRF047XW doesn’t run?
Please check the electrical parts, such as the PTC starter, capacitor, overload protector, thermostat, etc. If you find that the parts are malfunctioning, then replace them with a new one of the same type and specification. If all of these parts are good, please measure the resistance of the compressor winding. If the resistance is abnormal, you must replace the compressor. Otherwise, check if the overload protector is activated. If it is, it means there is an overly large current and the compressor is malfunctioning, so you should also replace the compressor.
What should I do if the power indicator is off and the compressor isn’t running on my PREMIUM PRF047XW?
| Check point and the detail | Caused by | |
|---|---|---|
| Check that other appliances are working or not. | No power supply in neighbor house | Field power supply is cut off. |
| All of other appliances in house don’t work | Main fuse is cut off. | |
| Only this freezer doesn’t work | Power supply outlet has problem |
Why won’t the compressor run on my PREMIUM PRF047XW even though the power indicator is on?
| Check point and the detail | Caused by |
|---|---|
| If the cooling thermostat is shorted of the circuit or turn the thermostat to the coldest point, the compressor can run. | Thermostat is breakdown |
| There is sound when turning the knob of the thermostat. | The knob is broken or is not installed properly. |
| Thermal protector may be overloaded. Check it is cutoff or not by the multi-meter. | If it is cutoff, means it is broken down. |
| PTC Starter. Check it is cutoff or not by the multi-meter. | If it is open, means it is broken down. |
| Check the circuit wiring. Check if it has a broken point or not in the circuit wiring according to the electrical diagram. | Maybe the lead is broken or the connection point is loosing. |
| Compressor problem. Measure the winding resistance of the compressor. | The winding is broken or burnt. |
What are possible issues if the compressor on my PREMIUM PRF047XW is running but not cooling properly?
| Check point and the detail | Caused by |
|---|---|
| Measure the insulation resistance by meg-ohm meter, if the insulation resistance < 1 ΜΩ, the unit can’t be used for long time. | The winding is burnt. |
| Power supply voltage is too low (Maybe lower than 175V). | Compressor can’t start because of under voltage. |
| There is no sound of refrigerant flowing in cooling system and it leaves oil on the welding point. | Leakage of refrigerant. |
| There is no sound of refrigerant flowing in cooling system and no oil on the welding point. | Inside leakage of cooling pipe or the pipe is blocked. |
| No air is discharged out on the discharging mouth of the compressor. | Compressor valve is breakdown. |
| There is abnormal sound inside compressor. | Compressor is breakdown. |
What does it mean if the frost is thicker than 5mm in my PREMIUM PRF047XW?
If the frost thickness is greater than 5mm, it indicates that the frost is too thick, which can be due to incorrect usage.
What should I check if my PREMIUM PRF047XW is running but the cooling effect is not good?
| Check point and the detail | Caused by |
|---|---|
| Thermostat is set at higher temperature (lower digit)? | Set it to lower temperature. |
| There is too much food in cooling compartment, too crowded, ensure good air circulation inside freezer. | Too much food. |
| Is there high temperature food, like hot soup etc., inside freezer? | Hot temperature food let the temperature inside freezer cooling compartment rise. |
| Too many times of opening of the door. | It will affect the cooling effect. |
| Check the door gasket sealing strip is broken or deforming. | Broken of the door gasket sealing strip. |
| Check the door is warped off by the food and the door is closed tightly or not. | The door is not closed tightly. |
| The freezer is inside direct sunshine. | The unit can not dissipate the heat because of sunshine. |
| The back of the unit is too close to the wall. | Too close will affect the heat dissipation. |
| There is heat source near the unit. | Over-hot environment will affect the heat dissipation. |
What could cause the temperature in my PREMIUM PRF047XW to be too low?
| Check point and the detail | Caused by |
|---|---|
| Check the sensor head of the thermostat is loosing or not. | Incorrect temperature sensing of thermostat. |
| Thermostat is not at good quality. | Thermostat is breakdown. |
Why is there condensed water on the closure of my PREMIUM PRF047XW?
If there is condensed water on the closure, it is because the environment is too wet, which means the relative humidity is too high.
What should I do if I feel an electrical shock from my PREMIUM PRF047XW?
| Check point and the detail | Caused by |
|---|---|
| Confirm the insulation resistance is lower than 1 MΩ by the meg ohm meter. | Insulation is not good. |
| Check the electrical parts of the unit are wet. | Insulation is not good. |
| Check the electrical parts touch with the metal enclosure or not, and the grounding lead is not grounded properly. | Electricity leakage. |
| Check if it has static electricity influence. | Static electricity influence. |
What causes excessive noise and vibration in my PREMIUM PRF047XW?
| Symptom | Check point and the detail | Caused by |
|---|---|---|
| There is sound inside compressor | Check if the compressor has abnormal sound or not. | Compressor abnormal |
| There is vibration sound | Check if the pipe is touched each other or not. | Pipe touching to produce resonance. |
| Check if the installation ground is flat and the feet is adjusted at proper position or not. | The unit is not placed evenly. |
What are the requirements for cooling system parts when servicing the PREMIUM PRF047XW with R134a refrigerant?
Because refrigerant R134a and its lubricating oil grease have strong water absorbability and oxidation ability, and will cause catalysis reactivity with chloride to produce impurity to be silt, you should pay more attention to the water quantity, oxide quantity, chloride quantity, oil quantity and impurity quantity in the cooling system, and control it more strictly.
Left water quantity control:
a) If the cooling system parts, like condenser, evaporator, compressor, or the dry filter etc., need to be replaced, the replaced parts should be stored charging with dry nitrogen with pressure 0.2~0.3Mpa. If these parts have leakage of nitrogen, they must be dried in a high temperature chamber and be taken out of the water before using.
b) The molecular dry desiccant inside the dry filter must be controlled strictly, guaranteed that the left water quantity must be lower than 1.5WT%. Normally, after the dry filter is opened from its vacuum package, it must be welded to the pipe system within 5 minutes. In a wet condition (relative humidity>50%), you must take measures to be protected from humidity, and the dry filter must be connected to the system pipe at once after removing it from its package, so as to produce a sealing system.
What are the requirements for service equipment when servicing the PREMIUM PRF047XW with R134a refrigerant?
1) No need for recycling equipment, except for a charging machine. If the equipment is special for the R134a refrigerant system, you must mark it clearly to avoid using it with other refrigerants (except for welding machine, pliers, electronic balance).
2) The vacuum machine and charging machine are special and should be used only for the R134a refrigerant system.
What are the special requirements and main points to consider during the service process for the PREMIUM PRF047XW?
Special requirement during service process:
(a). The duration from opening the compressor to the vacuuming process must be less than 10 minutes, and for other parts, not more than 12 minutes.
(b). The vacuuming duration should not be less than 20 minutes.
(c). If refrigerant leakage happens, it is necessary to replace the compressor. Before welding, dry the cooling system with nitrogen air.
(d). If a dust blockage happens in the cooling system pipe, if it can be blown out by the nitrogen, you don’t need to replace the compressor; otherwise, the cabinet is not useful (and the evaporator is not useful).
(e). If an ice blockage happens in the system pipe, you must replace the compressor.
(f). Change the dry filter only if the system is opened.
Main point of service:
1. The replaced compressor must be returned back to the compressor manufacturer to be treated.
2. The compressor can’t be tested through direct absorbing atmosphere; it will damage the compressor.
3. If the system pipe is opened for a long time or leakage happens, you can dry the system by nitrogen during service.
4. All of the welding material must be protected from wet conditions. And ensure to use as little as enough as possible.
5. Check if the compressor is pressurized or not when opening.
6. When storing the R134a refrigerant, you must keep it sealed and not in contact with the atmosphere directly.
What performance tests are required after servicing the PREMIUM PRF047XW?
After completing the service, it normally needs to be test run for 1-2 days. When proved to be safe and have good cooling performance, then move it to the customer or user. During test running, we suggest that you perform the following items:
1) Insulation and safety:
Before plugging in, use the DC 500 meg-ohm meter to measure the insulation resistance between the live parts and dead metal enclosure, ensuring the result is not lower than 1 meg-ohm.
2) Starting capability:
The compressor should start smoothly, and can start or stop normally. If the unit can’t start or stop normally, you must find the root cause and delete the cause, then you can plug it in to let it run.
3) Cooling performance:
After running for 24 hours, check that the frost on the surface of the cabinet liner is even, and there is no frost on the suction pipe.
4) Electrical structure and safety:
After service, check all of the electrical parts, ensure the connection terminal of the electrical parts don’t loose and the grounding wire is ok.
5) Leakage checking:
After running for 24 hours, check one by one of the welding points by using a halogen leakage detecting device or suds. If leakage happens again, then it should be serviced again.
What is the maintenance parts list for the PREMIUM PRF047XW?
| No. | Parts name | PCS/unit | Note |
|---|---|---|---|
| 1 | Compressor | 1 | |
| 2 | Thermal protector of compressor | 1 | |
| 3 | PTC starter | 1 | |
| 4 | Feet of compressor | 4 | |
| 5 | Refrigerant dry filter | 1 | |
| 6 | Thermostat | 1 | |
| 7 | Power cord assembly | 1 | |
| 8 | Adjustable feet | 4 | |
| 9 | Door gasket sealing strip | 1 | |
| 9 | Running indicator | 0 | |
| 10 | Power indicator | 0 |