What are the standard components included with the KANOMAX CLIMOMASTER 6551-21?

The standard components for the KANOMAX CLIMOMASTER 6551-21 are listed below:

Items MODEL Qty Functions
Main Body 6501-00 One of these
Main Body with analog output 6501-A0 With analog output function
Main Body with pressure sensor 6501-B0 With pressure measurement function
Main body with pressure sensor and analog output 6501-C0 With pressure measurement and analog output functions
Probe 6531-21 One of these Air velocity, air temperature, humidity sensor (directivity)
6541-21 Air velocity, air temperature sensor (directivity)
6542-21 Air velocity, air temperature sensor (needle-type)
6533-21 Air velocity, air temperature, humidity sensor (spherical)
6543-21 Air velocity, air temperature sensor (spherical)
6551-21 Air velocity sensor (mini-spherical, straight type)
6552-21 Air velocity sensor (mini-spherical, articulating type)
6561-21 Air velocity, air temperature sensor (directivity)
Probe Cable 6531-06 1 To connect Probe to Main Body
USB Cable 1 USB Communication Cable
Carrying Case 1 Hard case
Operation Manual 1
Manganese AA Batteries 6

What available accessories can be used with the KANOMAX CLIMOMASTER 6551-21?

Items MODEL Functions
Extension Rod (Flexible) 6531-04 For measurements in high places
Extension Rod (Straight) 6531-05 For measurements in high places
AC Adaptor 6113-02 Power Supply
Printer (Recommended) DPU-S245 To print out data, calculation results, etc.
Printer Cable 6000-31 To connect the Main Body to the Printer
Mobile ANEMOMASTER Measurement Software 6000-41 Data acquisition software
Hands-free Case 6000-61 For hands-free measurement

What do the safety symbols in the KANOMAX CLIMOMASTER 6551-21 manual mean?

The symbols indicate different levels of warnings and required actions:

Classifications:

Danger: To Prevent Serious Injury or Death – Warnings in this classification indicate a danger that may result in serious injury or death if not observed.

Caution: To Prevent Damage to the Product – Warnings in this classification indicate a risk of damage to the product that may void the product warranty if not observed.

Description of Symbols:

Triangle Symbol: This symbol indicates a condition that requires caution (including danger). The subject of each caution is illustrated inside the triangle (e.g., a high temperature caution symbol).

Circle with a slash Symbol: This symbol indicates a prohibition. Do not take the prohibited action shown inside or near this symbol (e.g., the disassembly prohibition symbol).

Solid circle with an exclamation mark Symbol: This symbol indicates a mandatory action. A specific action is given near the symbol.


What are the key safety precautions when operating the KANOMAX CLIMOMASTER 6551-21?

DANGER:

Never bring the probe close to a flammable gas atmosphere. The heated sensor may cause a fire or explosion.

Never touch the sensor. The sensor is heated during operation and touching it may cause burns or damage the sensor itself.

Do not disassemble or heat the batteries, or put them into a fire. This may cause burns and the batteries may burst.

If abnormal noises, smells or smoke occur, or if liquid enters the instrument, turn off the instrument immediately, and remove the batteries or pull out the plug. There is a possibility of malfunction, electric shock, and/or fire. Contact your local distributor for repair.

CAUTION:

Always unplug the instrument from the electrical outlet when the instrument is not in use. Failure to do so may cause an electrical shock, fire or circuit damage.

Do not use the instrument in a water vapor atmosphere. Condensed steam on the sensor will change the heat dissipation rate, resulting in inaccurate measurements and may cause damage.

This instrument is designed for use in a clean air stream without any dust or foreign materials, which can cause damage or impede accurate measurements.

Do not apply force to the sensor. If the sensor is deformed, its accuracy may be affected.

When measuring, ensure that the direction mark is facing into the airflow. Otherwise, the measurement may be inaccurate, as some sensors (uni-directional probes) have a specific directivity.


What are the handling, storage, and maintenance precautions for the KANOMAX CLIMOMASTER 6551-21?

Do not use or leave the instrument in a high temperature, high humidity or dusty environment, or under direct sunlight for a prolonged period.

Do not subject the instrument or the probe to strong impacts. Dropping the unit or placing heavy objects on it may cause damage.

Never disassemble, modify or repair the product.

Do not pick up or carry the instrument by the probe cable, as it may cause a malfunction or break the wire.

Remove the batteries from the battery compartment when storing the instrument for a long period. Do not leave exhausted batteries in the compartment. Insert batteries with the correct polarity to prevent battery leakage.

Do not wipe the instrument with a volatile solvent like thinner or benzene. Use a soft dry cloth. For persistent stains, use a cloth soaked in a neutral detergent.

Discharge any built-up static electricity from your body before touching the instrument to prevent damage to the circuit.

Regularly check the head of the probe for contamination. To clean dust, use a blow brush for cameras or rinse with water and allow it to air-dry completely. Always turn the power off before cleaning and never dry the probe with heat.

Do not move the main unit and the probe from a cold to a warm place quickly to avoid condensation, which can cause inaccurate measurements and rusting.

Do not touch the LCD screen with a sharp-pointed object or with excessive pressure.

When storing the instrument, put it in the carrying case and keep it in a place with an ambient temperature of -10 to 50°C and no condensation.

Do not dispose of the instrument as household waste. Disposal of the instrument and batteries should be in line with your local or national legislation.


How do I install or replace the batteries on the KANOMAX CLIMOMASTER 6551-21?

Follow these steps to install the batteries:

1. On the backside of the body, press down on the battery cover.

2. Slide the cover until it stops.

3. Lift the cover away from the body.

4. Insert six (6) AA size batteries according to the indicated polarity chart. The instrument requires all six batteries to be of the same type. Do not mix different types of batteries. Note that batteries cannot be recharged by the AC adapter.

Types of batteries that can be used are:

Manganese AA size batteries

Alkaline AA size batteries

Ni-Cd AA size batteries

Ni-MH AA size batteries

5. Put the cover back on by reversing the above procedure.


How do I connect and disconnect the probe on my KANOMAX CLIMOMASTER 6551-21?

Always make sure the power is turned OFF when connecting or disconnecting the probe or probe cable.

Connecting the Probe:

1. Align the connector of the probe or probe cable with the probe terminal on the body. When connecting the probe, ensure the probe number faces towards the front side of the main unit.

2. Line up the connector and the terminal and gently push until it clicks. Do not force or rotate the connector once it is connected, as this may cause serious damage.

Disconnecting the Probe:

1. Lightly lift the locking ring of the probe/probe cable.

2. Pull the probe/probe cable out vertically while holding the lock ring up. Do not rotate the connector when it is connected to the main body.


How do I turn the KANOMAX CLIMOMASTER 6551-21 on and off?

The power switch is located on the side of the instrument.

Power ON: Slide the switch to the “|” position.

Power OFF: Slide the switch to the “O” position.

When you turn the power on after connecting the probe, a test screen will be displayed for a few seconds before it switches to the Normal Mode screen. If the probe is not connected properly, a “NO PROBE!” warning will be displayed. If this happens, turn the power off and check the probe connection.


What do the different battery level indicators on the KANOMAX CLIMOMASTER 6551-21 mean?

The battery level indicator on the display shows the remaining battery level. The indicator changes as the battery level decreases.

Full to Low: The indicator icon will show a decreasing number of bars.

Blinking Indicator: When the batteries need to be replaced or recharged, the indicator will start blinking. The screen may freeze if a high velocity is measured when the indicator is blinking.

Locked Status ( [X] symbol): When this symbol is displayed, all functions are locked. The current measurement will be cancelled and data will not be saved. To release the lock, turn off the power and replace the batteries.


What are the precautions for measuring air velocity, air temperature, and humidity with the KANOMAX CLIMOMASTER 6551-21?

Air Velocity:

For directional probes (MODEL 6531/6541/6561), make sure the direction mark is facing into the airflow. If unsure of the direction, slowly rotate the probe to find the maximum velocity reading.

For omnidirectional probes (MODEL 6533/6542/6543/6551/6552), be aware of their 360-degree horizontal dynamic characteristic.

Ensure both the air velocity sensor and temperature compensation sensor are evenly exposed to the airflow under the same temperature conditions.

In environments with rapid air temperature changes, wait for the reading to stabilize for at least 20 seconds before starting the measurement.

Air Temperature:

Response time is faster in higher wind speeds. Wait for the reading to become stable before measuring. The normal response time is approximately 30 seconds at 1 m/s air velocity.

When there is no airflow, the reading may be higher than the actual temperature due to heat from the air velocity sensor. It is recommended to slowly wave the probe to create approx. 0.1m/s airflow for accurate readings.

Humidity:

In atmospheres with extremely high humidity or rapid temperature changes, readings may be higher due to condensation on the sensor. If this occurs, allow the probe to dry in an environment with 40%RH or less for 24 hours.


How do I perform a pressure zero adjustment on my KANOMAX CLIMOMASTER 6551-21?

Before measuring pressure, perform a zero adjustment with both pressure ports (+) and (-) open.

1. Press the MENU key to enter the Main Menu.

2. Use the navigation keys to select “8. PRESSURE ZERO” and press SET.

3. Use the navigation keys to select “1. ZERO ADJUST” and press SET.

4. Use the navigation keys to select “YES”.

5. Press SET to display 0.00 kPa.

6. Use the navigation keys to select “2. SAVE INFO”.

7. Press SET. This completes the zero adjustment and returns you to the Main Menu.

If you press MENU before saving, you will return to the Main Menu without completing the adjustment.


How do I input the duct shape and size on the KANOMAX CLIMOMASTER 6551-21?

Before measuring volumetric flow rate, you must enter the duct shape and size settings. You can register up to 25 different duct types.

1. Press MENU to enter the Main Menu.

2. Use the navigation keys to select “2. DUCT TYPE” and press SET.

3. Set Duct ENTRY No.: Select “1. ENTRY No.” and press SET. Use the navigation keys to choose a memory address from 1 to 25 and press SET.

4. Set Duct SHAPE: Select “2. SHAPE” and press SET. Use the navigation keys to select “RECTANGLE” or “CIRCLE” and press SET.

5. Set Duct Size:

For a Rectangular Duct: Select “3. WIDTH”, press SET, enter the width, and press SET. Then select “4. HEIGHT”, press SET, enter the height, and press SET. The maximum is 9999mm or 999.9 inch.

For a Circular Duct: Select “3. DIAMETER”, press SET, enter the diameter, and press SET. The maximum is 9999mm or 999.9inch.

6. Set Units (mm/inch): Select “5. UNIT(mm/inch)” (or “4.” for a circular duct) and press SET. Use the navigation keys to select mm or inch and press SET.

7. Save the Setting: Select “6. SAVE INFO” and press SET. This will complete the input and return you to the Main Menu.


How do I hold a reading or the maximum value in NORMAL Mode on the KANOMAX CLIMOMASTER 6551-21?

Hold the Current Reading:

While measuring in NORMAL Mode, press the START/HOLD key to hold the current reading. The “HOLD” indicator will appear on the display. This applies to flow rate and pressure screens as well. Press START/HOLD again to release.

Hold the Maximum Value:

While measuring in NORMAL Mode, press and hold the START/HOLD key. The “HOLD” indicator will appear. As long as you keep the button pressed, the instrument will display the maximum value of each parameter (air velocity, air temperature, humidity, and pressure). When you release the button, the reading will be frozen. Press START/HOLD again to release.


How do I set the Time Constant on the KANOMAX CLIMOMASTER 6551-21?

In NORMAL Mode, you can change the Time Constant (TC) by pressing the up/down navigation keys. The Time Constant determines the time span of the moving average. A longer value provides more stable readings, while a shorter value is more responsive.

You can select from:

TC1: Displays the instantaneous value at every 1 second.

TC5: Displays the moving average for the past 5 seconds.

TC10: Displays the moving average for the past 10 seconds.

By default, the time constant is only effective for AIR VELOCITY and AIR FLOW measurements. To apply it to AIR TEMPERATURE, HUMIDITY, and PRESSURE as well, you must change the settings.


How do I perform a measurement in CALCULATION Mode on the KANOMAX CLIMOMASTER 6551-21?

CALCULATION Mode automatically calculates the maximum, minimum, and mean of measured data.

Setup:

1. Press MENU and select “3. CALCULATION”, then press SET.

2. Select “1. MODE” and choose AVERAGE (displays average for sampling time) or INSTANT (takes a single measurement at the end of sampling time). Press SET.

3. Select “2. SAMPLING (TIME)” and set the duration from 1 to 999 seconds. Press SET.

4. Select “3. SAMPLING(n)” and set the number of trials from 1 to 9999. Press SET.

5. Select “4. DATA STORAGE?” and choose YES or NO. Press SET.

6. Select “5. SET TO START” and press SET. The instrument will be in READY mode.

Measurement:

1. In the READY screen, press MODE to change the applied parameters if needed (Air Velocity, Flow Rate, Pressure, etc.).

2. Press START/HOLD to start the measurement.

3. The measurement will proceed according to your settings. Press START/HOLD to stop it. If you selected YES for data storage, the data will be stored. Pressing MENU will also stop the measurement, but the data will not be saved.

4. After all trials are finished, the calculated results (MAX, AVG, MIN) will be displayed. Use the navigation keys to cycle through results for each parameter.


How do I clean the probe of my KANOMAX CLIMOMASTER 6551-21?

Clean the sensor by soaking it in water in an ultrasonic cleaner for 10 to 20 seconds. Do not soak it for too long to avoid damaging the coating. Please use only water for cleaning the probe.

CAUTION:

When cleaning, make sure the power is turned OFF.

Make sure that the sensor is dry before turning it ON.

DO NOT let the humidity sensor come into contact with water. If it gets wet, let it air dry by placing it in an environment with less than 40%RH for more than 24 hours.

NEVER USE alcohol or any other organic fluid, as it will cause permanent damage to the humidity sensor.

DO NOT place the sensor in an upward position until it is completely dry as residual water could damage the sensor.

After cleaning, you can dry the probe with cool air.


What are the specifications of the KANOMAX CLIMOMASTER 6551-21?

Product CLIMOMASTER Air Velocity Meter
Model No. of the Main Body 6501
Model No. of the Probe 6531-21 6541 -21 6561 -21 6542 -21 6551 -21 6552 -21 6533-21 / 6543-21
Measuring Object Clean air flow
Air Velocity [m/s] Measuring Range 0.01 to 30.0, 0.01 to 50.0 (6561-21 only) 0.01 to 5.00
Resolution 0 to 9.99: 0.01
10 to 30: 0.1
30 to 50: 0.1 (6561-21 only)
0.01
Accuracy ±2% of reading or ±0.015 (±3FPM), whichever is greater 0.01 to 0.99:±0.02
0.99 to 5.00: ±2% of reading or ±0.015 (±3FPM), whichever is greater
Air Temperature [°C] Response Time [sec.] Approx. 1 Approx. 4 Approx. 7 (at 1m/s, 90% response time) Approx. 7
Measuring Range -20.0 to 70.0 -20.0 to 70.0
Accuracy ±0.5 ±0.5
Humidity [%RH] Response Time [sec.] Approx. 30 (at 1m/s, 90% response time) Approx. 30 (at 1m/s, 90% response time)
Accuracy 2 to 80: ±2.0
80 to 98: ±3.0
2 to 80: ±2.0
80 to 98: ±3.0
Pressure [kPa] Accuracy ±3% of reading or ±0.01
Functions Readings Hold, Max Hold, Time Constant (1, 5, 10 sec.), Battery Level Indicator (5 Levels), Unit selection, Max., Min., and Average Calculation, Sampling Time: 1 to 999 sec. No. of trails: 1 to 9999, Store up to 25 Duct Sizes, Max.Data Storage: 20000
Output Digital Output: USB (when connected to a printer, automatically switch to RS-232C, Baud Rate 4800, 9600, 19200 and 38400 bps)
Analog Output: DC 0 to 1V
Power 6 × AA Batteries, AC Adaptor: AC 100 to 240V (50/60Hz)
Battery Life Approximately 10 continuous hours (at air velocity 5m/s, 20°C, with alkaline batteries)
Operating Environment Main Body: 5 to 40°C (41 to 104°F) with no visible condensation
Probe: -20 to 70°C (-4 to 158 °F) with no visible condensation
Storage Environment -10 to 50°C (14 to 122°F) with no visible condensation
Weight Approximately 400g (batteries included)
Accessories Carrying case, Operation manual, 6×AA Batteries, Probe cable (2m), USB cable

What are the Discomfort Index (DI) and Dew Point Temperature (DT) calculated by the KANOMAX CLIMOMASTER 6551-21?

Discomfort Index (DI)

Discomfort Index is an index to show how uncomfortable it is in the summer time. The KANOMAX CLIMOMASTER 6551-21 uses the formula: DI = 0.81T + 0.01H(0.99T – 14.3) + 46.3, where T is Temperature (°C) and H is Relative Humidity (%RH).

The DI Scale is as follows:

Comfortable Little Uncomfortable Uncomfortable Very Uncomfortable Cannot Endure
68 70 75 80 86

Dew Point Temperature (DT)

This is calculated using a formula based on saturated vapor pressure.


The KANOMAX CLIMOMASTER 6551-21 will not turn on. What should I do?

The battery may be inserted with the wrong polarity. Turn off the power and insert the battery correctly according to the polarity markings.


The display on my KANOMAX CLIMOMASTER 6551-21 is not visible or is too dark/light. What is the cause?

The display contrast may not be set up properly. You can adjust the contrast volume switch/dial, which is located inside the battery compartment.


The battery level indicator is flashing on my KANOMAX CLIMOMASTER 6551-21. What does this mean?

This indicates that the battery is low. Turn off the instrument and replace the batteries.


Why is “[NO PROBE]” displayed on my KANOMAX CLIMOMASTER 6551-21?

This message indicates that the probe is not connected. Turn off the instrument and ensure the probe is securely connected.


Can I change the measurement units on the KANOMAX CLIMOMASTER 6551-21?

Yes, you can change the measurement units by following the steps on page 46 of the user manual.


What does it mean when my KANOMAX CLIMOMASTER 6551-21 displays “[**.*]” as the measured value?

This indicates that the measurement is outside the measuring range. The instrument must be used within the range stated in the specifications.


Why is my KANOMAX CLIMOMASTER 6551-21 displaying “[—-]” for the air velocity measurement?

This could be due to a few reasons:

The probe or the probe cable is not connected properly. Check the connection between the probe and the probe cable.

The probe or the probe cable may be damaged. In this case, contact your local representative for repair or replacement.


Why isn’t my KANOMAX CLIMOMASTER 6551-21 reading the correct air speed?

The probe might not be facing into the wind. For directional probes, make sure the wind direction indicator is facing into the wind.


Why does the KANOMAX CLIMOMASTER 6551-21 read a higher temperature with no wind?

The device cannot measure the correct temperature with no wind (less than 0.1m/s of wind) due to heat from the sensor. For an accurate reading in still air, slowly wave the probe.


The response time of my KANOMAX CLIMOMASTER 6551-21 is slow. What should I check?

Check that the correct time constant (TC) is set. A longer time constant (e.g., TC10) will result in a slower response time.


Why is “[—–]” displayed as the air volumetric flow measurement on my KANOMAX CLIMOMASTER 6551-21?

This indicates that the duct information (shape and size) is not stored. You must register the duct information in the settings to get a flow measurement.


My printer doesn’t operate with the KANOMAX CLIMOMASTER 6551-21. What are the possible causes?

There are several possible causes:

The printer is not connected properly. Confirm the printer connection.

The Baud Rate might not be set properly. Check that both the instrument and printer settings match.

You may not be using the optional printer (Model DPU-S245) and printer cable (Model 6000-31).

The connection procedure may be incorrect. Connect the printer to the printer port, then turn on the instrument and then the printer.


I cannot printout the display from my KANOMAX CLIMOMASTER 6551-21. What should I do?

The display is not frozen. First, press START/HOLD to hold the display. Then, press MODE to print out.


My PC doesn’t load the measuring data from the KANOMAX CLIMOMASTER 6551-21. What should I check?

Confirm the USB connection, which is different from the printer connection.

The Baud Rate might not be set properly. Check that both the instrument and PC settings match.

Confirm you are using the correct communication command (e.g., in Hyper Terminal).


No data is being generated from the analog output of my KANOMAX CLIMOMASTER 6551-21. What could be the issue?

First, check the connection and confirm the polarity is correct.

Second, the HOLD function might be active. Press START/HOLD to cancel the HOLD function.


The output data from my KANOMAX CLIMOMASTER 6551-21 is not correct. What should I check?

Confirm the setting for analog output and confirm the output range is correctly selected.

The load impedance might not be optimum. Set the load impedance to be larger than 5k Ω.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD KANOMAX CLIMOMASTER 6551-21 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.