What do the symbols in the user manual for the HIKVISION DS-K1T607PMW mean?

The symbols in the user manual for your HIKVISION DS-K1T607PMW are defined as follows:

Symbol Description
Danger Indicates a hazardous situation which, if not avoided, will or could result in death or serious injury.
Caution Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance degradation, or unexpected results.
Note Provides additional information to emphasize or supplement important points of the main text.

What are the key safety instructions for using the HIKVISION DS-K1T607PMW?

Dangers:

Follow these safeguards to prevent serious injury or death.

  • All electronic operations must comply with electrical safety, fire prevention, and other related regulations in your local region.

  • Use the provided power adapter. The equipment is intended to be supplied from a Class 2 surge-protected power source rated DC 12V, 3A.

  • Do not connect multiple devices to one power adapter to avoid overload, which can cause overheating or a fire hazard.

  • Ensure power is disconnected before you wire, install, or dismantle the device.

  • When installed on a wall or ceiling, the device must be firmly fixed.

  • If you see smoke, odors, or noise from the device, turn off the power immediately, unplug the power cable, and contact the service center.

  • Do not ingest the battery, as it is a Chemical Burn Hazard. This product contains a coin/button cell battery. If swallowed, it can cause severe internal burns in just 2 hours and can lead to death. Keep new and used batteries away from children. If you suspect a battery has been swallowed or placed inside any part of the body, seek immediate medical attention.

  • If the product does not work correctly, contact your dealer or the nearest service center. Do not attempt to disassemble the device yourself.

Cautions:

Follow these precautions to prevent potential injury or material damage.

  • Do not drop the device or subject it to physical shock. Avoid high electromagnetism radiation and installation on vibrating surfaces.

  • Do not place the device in extremely hot, cold, dusty, or damp locations. Refer to the specifications for the detailed operating temperature.

  • The device cover for indoor use must be kept from rain and moisture.

  • Avoid exposing the equipment to direct sunlight, low ventilation, or heat sources like heaters or radiators.

  • Do not aim the device at the sun or extra bright places to avoid blooming or smear, which can affect sensor endurance.

  • Use the provided glove when handling the device cover to prevent acidic sweat from eroding the surface coating.

  • Use a soft, dry cloth to clean the inside and outside surfaces of the device cover. Do not use alkaline detergents.

  • Improper use or replacement of the battery can result in an explosion hazard. Replace only with the same or equivalent type. Dispose of used batteries according to the manufacturer’s instructions.

  • Biometric recognition products are not 100% applicable to anti-spoofing environments. For higher security, use multiple authentication modes.

  • For indoor use, install the device at least 2 meters from any light and at least 3 meters from a window or door. For outdoor use, apply silicone sealant around the cable wiring area to prevent rain from entering.

  • The device has a protection level of IP65.


What are the different models available for the HIKVISION DS-K1T607PMW and what power supplies should be used?

The HIKVISION DS-K1T607PMW is part of the DS-K1T607 Series Face Recognition Terminal. The available models are:

Product Name Model
Face Recognition Terminal DS-K1T607M
DS-K1T607MF
DS-K1T607E
DS-K1T607EF
DS-K1T607MW
DS-K1T607MFW
DS-K1T607PE
DS-K1T607PEF
DS-K1T607PMW
DS-K1T607PMFW
DS-K1T607TM
DS-K1T607TMF
DS-K1T607TE
DS-K1T607TEF
DS-K1T607TMW
DS-K1T607TMFWW

Use only the power supplies listed in the user instructions:

Model Manufacturer Standard
C2000IC12.0-24P-DE MOSO Power Supply Technology Co., Ltd. CEE
C2000IC12.0-24P-GB MOSO Power Supply Technology Co., Ltd. BS
KPL-040F-VI Channel Well Technology Co Ltd. CEE

What are the main components of the HIKVISION DS-K1T607PMW?

The main components and their descriptions for the HIKVISION DS-K1T607PMW are as follows:

No. Name Description
1 Fingerprint Module For fingerprint recognition. Note: Only parts of models support this function.
2 Card Swiping Area Swipe card within this area.
3 Display Screen 7-inch LCD touch screen.
4 Camera (IR Light) IR light camera for recording or capturing videos or pictures in IR light.
5 Camera (White Light) White light camera for recording or capturing white light videos or pictures.
6 Supplement Light (White Light) Supplement light for white light camera.
7 Supplement Light (IR Light) Supplement light for IR camera.
8 Supplement Light (IR Light) Supplement light for IR camera.
9 USB Interface Connect to USB flash drive.
10 Network Interface Connect to Ethernet.
11 SIM Card Slot Reserved.
12 Debugging Port The debug terminal is used for debugging only.
13 Power Interface Connect to power supply.
14 Wiring Terminals Connect to other external devices, including RS-485 card reader, Wiegand card reader, door lock, alarm input, alarm output, etc.
15 PSAM Card Slot Reserved.

How do I install the HIKVISION DS-K1T607PMW with a gang box?

Before installing, ensure the environment illumination is more than 100 Lux. For indoor installation, the device should be at least 2 meters from light and 3 meters from a window/door. For outdoor installation, apply silicone sealant to the cable wiring area to prevent rain entry.

Follow these steps to install your HIKVISION DS-K1T607PMW with a gang box:

  1. Stick the mounting template on the wall or other surface, ensuring the datum line is 1.4 meters higher than the ground.

  2. Drill holes according to the mounting template and install the gang box.

  3. Use two supplied screws (4_KA4 × 22-SUS) to secure the mounting plate on the gang box.

  4. Use another four supplied screws to secure the mounting plate on the wall.

  5. Remove the two screws on the rear panel of the device and remove the sheet to display the wiring terminals.

  6. Route the necessary cables through the cable hole of the mounting plate and connect them to the corresponding external devices’ cables.

  7. Reinstall the sheet back to the device with the two screws.

  8. Apply silicone sealant among the cable wiring area to keep rain from entering.

  9. Optional: If your model has a fingerprint module, insert it into the holes at the bottom of the main part.

  10. Align the device with the mounting plate and hang it on the plate.

  11. Use two supplied screws (SC-M4 × 12TP10-SUS) to secure the device to the mounting plate.


How do I install the HIKVISION DS-K1T607PMW without a gang box?

Before installing, ensure the environment illumination is more than 100 Lux. For indoor installation, the device should be at least 2 meters from light and 3 meters from a window/door. For outdoor installation, apply silicone sealant to the cable wiring area to prevent rain entry.

Follow these steps to install your HIKVISION DS-K1T607PMW without a gang box:

  1. Stick the mounting template on the wall or other surface, ensuring the datum line is 1.4 meters higher than the ground.

  2. Drill 6 holes on the wall according to Hole 1 and Hole 2 on the mounting template.

  3. Insert the screw sockets of the setscrews into the drilled holes.

  4. Align the 6 holes of the mounting plate with the drilled holes and secure it with screws.

  5. Remove the two screws on the rear panel of the device and remove the sheet to display the wiring terminals.

  6. Route the necessary cables through the cable hole of the mounting plate and connect them to the corresponding external devices’ cables.

  7. Reinstall the sheet back to the device with the two screws.

  8. Apply silicone sealant among the cable wiring area to keep rain from entering.

  9. Optional: If your model has a fingerprint module, insert it into the holes at the bottom of the main part.

  10. Align the device with the mounting plate and hang it on the plate.

  11. Use two supplied screws (SC-M4 × 12TP10-SUS) to secure the device to the mounting plate.


What are the wiring terminal descriptions for the HIKVISION DS-K1T607PMW?

The terminals on the HIKVISION DS-K1T607PMW contain power input, alarm input, alarm output, RS-485, Wiegand output, and door lock connections. The descriptions are as follows:

Group No. Function Color Name Description
Group A A1 Power Input Red +12 V 12 VDC Power Supply
A2 Black GND Ground
Group B B1 Alarm Input Yellow/Blue IN1 Alarm Input 1
B2 Yellow/Black GND Ground
B3 Alarm Output Yellow/Orange IN2 Alarm Input 2
B4 Yellow/Purple NC Alarm Output Wiring
B5 Yellow/Brown COM
B6 Yellow/Red NO
Group C C1 RS-485 Yellow 485+ RS-485 Wiring
C2 Blue 485-
C3 Black GND Ground
C4 Wiegand Green W0 Wiegand Wiring 0
C5 White W1 Wiegand Wiring 1
C6 Brown WG_OK Wiegand Authenticated
C7 Orange WG_ERR Wiegand Authentication Failed
C8 Purple BUZZER Buzzer Wiring
C9 Gray TAMPER Tampering Alarm Wiring
Group D D1 Door Lock White/Purple NC Lock Wiring (NC)
D2 White/Yellow COM Common
D3 White/Red NO Lock Wiring (NO)
D4 Yellow/Green SENSOR Door Contact
D5 Yellow/Gray BTN Exit Door Wiring

How do I activate the HIKVISION DS-K1T607PMW for the first time?

You must activate your HIKVISION DS-K1T607PMW before the first login. You can activate it via the device itself, the SADP tool, or client software. The default values are:

  • IP Address: 192.0.0.64

  • Port No.: 8000

  • User Name: admin

Activate via Device

  1. After powering on the device, the system will enter the Device Activation page.

  2. On the “Activate Device” page, create a strong password.

  3. Confirm the password.

  4. Tap “Activate” to complete the activation.

Password Strength Recommendation: Use a minimum of 8 characters, including at least three of the following: upper case letters, lower case letters, numbers, and special characters.


How do I set the application and recognition modes on the HIKVISION DS-K1T607PMW after activation?

Set Application Mode

After activating the device, you should select an application mode for better performance.

  1. On the Welcome page, select Indoor or Others from the drop-down list.

  2. Tap OK to save.

Note: If you install the device indoors near a window or if face recognition is not working well, select Others. If you do not configure this, the system will default to Indoor.

Set Recognition Mode

After setting the application mode, select a face recognition mode.

  1. On the Welcome page, select Normal Mode or Deep Mode from the drop-down list.

    • Normal Mode: Recognizes faces via the camera normally.

    • Deep Mode: Recognizes a much wider range of people and is suitable for more complicated environments.

  2. Tap OK to save.

Note: The system will default to Normal if not configured. Normal mode and deep mode are not compatible; it is suggested not to change this parameter once it is configured.


How do I log in to the HIKVISION DS-K1T607PMW?

Login for the First Time

  1. Long tap on the initial page for 3 seconds to enter the password entry page.

  2. Tap the Password field and enter the device activation password you created.

  3. Tap OK to enter the home page.

Note: The device will be locked for 30 minutes after 5 failed password attempts.

Login by Administrator

After you have added an administrator to the device, only the administrator can log in to perform device operations.

  1. Long tap on the initial page for 3 seconds to enter the admin login page.

  2. Authenticate using the administrator’s face, fingerprint, or card to enter the home page.

Note: The device will be locked for 30 minutes after 5 failed fingerprint or card attempts. You can tap the lock icon to enter the activation password for login if needed.


How do I configure communication settings on the HIKVISION DS-K1T607PMW?

You can configure Network, Wi-Fi, RS-485, and Wiegand parameters from the Communication Settings page.

  1. Tap Comm. (Communication Settings) on the Home page.

Set Network Parameters

  1. On the Communication Settings page, tap Network.

  2. Tap IP Address, Subnet Mask, or Gateway and input the required parameters.

  3. Tap OK to save the settings.

Set Wi-Fi Parameters

  1. On the Communication Settings page, tap Wi-Fi.

  2. Enable the Wi-Fi function.

  3. Select a Wi-Fi network from the list.

  4. Select an IP mode (Static or Dynamic) and input the password and any required network details.

  5. Tap OK to save.

Set RS-485 Parameters

  1. On the Communication Settings page, tap RS-485.

  2. Select an external device (Controller, Unit, or Reader) based on your needs.

  3. Tap the checkmark to save the network parameters. The device will reboot if you change the external device.

Set Wiegand Parameters

  1. On the Communication Settings page, tap Wiegand.

  2. Enable the Wiegand function.

  3. Select a transmission direction:

    • Output: To connect to an external access controller.

    • Input: To connect to a Wiegand card reader.

  4. Tap the checkmark to save. The device will reboot if you change the parameters.


How do I add users and their credentials on the HIKVISION DS-K1T607PMW?

You can add users and manage their credentials (face picture, fingerprint, card, password) from the User Management interface.

To add a new user:

  1. On the Home page, tap User+ to enter the Add User page.

  2. Edit the Employee ID (must be unique, less than 32 characters, and not start with 0).

  3. Tap the Name field and input the user’s name.

To add credentials:

  • Add Face Picture:

    1. Tap the Face Picture field.

    2. Position your face looking at the camera, ensuring it is within the outline.

    3. The device will capture the picture automatically.

    4. Tap Save.

  • Add Fingerprint:

    1. Tap the Fingerprint field.

    2. Place your finger on the fingerprint module and follow the on-screen instructions.

    3. After adding the fingerprint, tap Yes on the pop-up to save and add another, or No to save and return to the user page. (Up to 10 fingerprints per user).

  • Add Card:

    1. Tap the Card field.

    2. Enter the card number manually or swipe the card over the swiping area to capture the number.

    3. Optionally, enable the Duress Card function.

  • Add Password:

    1. Tap the Password field.

    2. Create and confirm a password (numbers only, up to 8 characters).

After adding credentials, you can set the Authentication Mode (Device or Custom) and tap the checkmark to save all settings.


How can I import and export user data on the HIKVISION DS-K1T607PMW using a USB flash drive?

Export Data

  1. Tap Transfer on the Home page.

  2. Tap one of the export options: Export Att. Data, Export User Data, Export Face Pic., Export Access Control Param., or Export Captured Pic.

  3. Plug a USB flash drive into the device.

  4. Tap Yes on the pop-up page. The data will be exported to the USB flash drive.

Note: The supported USB flash drive format is DB. The system supports storage from 1G to 32G, with more than 512M of free space.

Import Data

  1. Plug a USB flash drive containing the data into the device.

  2. On the Transfer page, tap Import User Data, Import Face Pic., or Import Access Control Param.

  3. Tap Yes on the pop-up window, and the data will be imported from the USB flash drive to the device.

Note: The supported USB flash drive format is FAT32. For picture imports, pictures should be saved in a root directory folder named “enroll_pic” and follow the naming rule: Card No._Name_Department_Employee ID_Gender.jpg.


What system settings can I configure on the HIKVISION DS-K1T607PMW?

On the System Settings page, you can configure basic parameters, face picture parameters, fingerprint parameters, and time settings.

Tap System on the Home page to enter System Settings.

Basic Parameters

Parameter Description
Community No. Set the device installed community No.
Building No. Set the device installed building No.
Unit No. Set the device installed Unit No.
Voice Prompt Enable or disable the voice prompt.
Voice Volume Adjust the voice volume.
Application Mode Select others or indoor according to the environment.
Wake-up Distance The live view on the device screen will enter the IR mode.
IR Light Brightness Set the IR light brightness when the IR light is enabled.
White Light Brightness Set the supplement white light’s brightness (0-100). 0 is off, 100 is brightest.

Face Picture Parameters

Tap the Face Pic. tab to configure settings like 1:N security level, face anti-spoofing, recognition interval, margin settings, pitch/yaw angles, and WDR level.

Fingerprint Parameters

Tap the Fingerprint tab to set the fingerprint security level. A higher level decreases the false acceptance rate (FAR) but increases the false rejection rate (FRR).

Time Settings

Tap Time on the Home page to set the device time and DST (Daylight Saving Time).


How do I configure Time and Attendance (T&A) status settings on my HIKVISION DS-K1T607PMW?

You can set the attendance mode as disable, manual, auto, or a combination. Tap T&A Status on the Home page to begin.

Disable Attendance Mode

Set the Attendance Mode to Disable. You will not view or configure attendance status on the initial page, and the system will follow rules from the platform.

Set Manual Attendance

  1. Set the Attendance Mode to Manual.

  2. Enable the Attendance Status function.

  3. After authentication, you must manually select an attendance status (e.g., Check In, Check Out). If you do not select a status, the authentication will fail and not be marked as valid.

Set Auto Attendance

  1. Set the Attendance Mode to Auto.

  2. Select an attendance status (e.g., Break Out) and set its schedule.

  3. The system will automatically mark authentications within the configured schedule with the corresponding status.

Set Manual and Auto Attendance

Set the Attendance Mode to Manual and Auto. The system will automatically change the status based on the schedule, but you can also manually change it after authentication.


What access control parameters can be set on the HIKVISION DS-K1T607PMW?

On the Home page, tap ACS (Access Control Settings) to configure access permissions. The available parameters are:

Parameter Description
Terminal Auth. Mode Select the terminal’s authentication mode (e.g., Card/Face/FP). You can also customize the mode.
Reader Auth. Mode Select the card reader’s authentication mode.
NFC Anti-Cloning Enable this to prevent the use of cloned cards for authentication.
Door Contact Select “Open (Remain Open)” or “Close (Remain Closed)”. Default is Close.
Anti-Passback When enabled, persons must authenticate according to a configured path set in the client software.
Door Locked Time Set the door unlocking duration (1 to 255s). If the door isn’t opened within this time, it will re-lock.
Door Open Timeout Alarm Triggers an alarm if the door remains open for longer than the set time (0 to 255s).
Continuous Failed Auth. Alarm Triggers an alarm after a set number of consecutive failed authentication attempts.

How do I perform maintenance tasks like upgrading firmware on the HIKVISION DS-K1T607PMW?

Upgrade Firmware

  1. Plug in a USB flash drive containing the upgrade file (digicap.dav) in the root directory.

  2. On the System Settings page, tap Maint. (Maintenance).

  3. Tap Upgrade.

  4. The device will automatically read the file and begin the upgrade. Do not power off during this process.

Data Management

Tap Data (Data Management) to manage device data. You can perform the following actions:

  • Delete All Events: Deletes all events stored in the device.

  • Delete User Data: Deletes all user data in the device.

  • Delete Captured Pic.: Deletes all captured pictures.

  • Restore to Factory: Restores the system to factory settings. The device will reboot.

  • Restore to Default: Restores parameters to default but saves communication and remote user settings. The device will reboot.


What are the recommended tips for scanning a fingerprint on the HIKVISION DS-K1T607PMW?

  • Recommended Finger: Use your forefinger, middle finger, or third finger.

  • Correct Scanning: Press your finger on the scanner horizontally. The center of your scanned finger should align with the center of the scanner.

  • Incorrect Scanning: Avoid scanning vertically, from the edge, or from the side of your finger.

  • Environment: The scanner should avoid direct sunlight, high temperature, humid conditions, and rain. If your finger is too dry, you can blow on it before scanning again.

  • Others: If your fingerprint is shallow or hard to scan, it is recommended to use other authentication methods. If you have injuries on the scanned finger, the scanner may not recognize it; try a different finger.


What are the best practices for collecting and comparing a face picture on the HIKVISION DS-K1T607PMW?

To get a good quality and accurate face picture, follow these recommendations:

  • Position: The recommended distance from the device is 0.5 meters. Ensure you are not too high, too low, too close, or too far from the camera.

  • Expression: Keep your expression natural, similar to a standard passport photo.

  • Accessories: Do not wear a hat, sunglasses, or other accessories that can obstruct the facial recognition function. Do not let your hair cover your eyes or ears. Heavy makeup is not allowed.

  • Posture: Position your face looking directly at the camera. Avoid tilting your head up, down, or to the side.

  • Size: Make sure your face is centered in the middle of the collecting window.


What are the installation environment requirements for the HIKVISION DS-K1T607PMW?

To ensure optimal performance of your HIKVISION DS-K1T607PMW, follow these installation environment guidelines:

  1. Light Source Illumination: The device operates under different lighting conditions. Reference values are:

    • Candle: 10 Lux

    • Bulb: 100~850 Lux

    • Sunlight: More than 1200 Lux

  2. Distance from Light/Windows: Install the device at least 2 meters away from any direct light source and at least 3 meters away from a window or door.

  3. Avoid Backlight and Sunlight: Do not install the device in a location with strong backlight, direct sunlight, indirect sunlight through a window, or in close proximity to a strong light source.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD HIKVISION DS-K1T607PMW (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.