Free English AXIS T90D20 IR-LED (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD AXIS T90D20 IR-LED (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
What are the hazard and message levels used in the AXIS T90D20 IR-LED installation guide?
The guide uses the following levels to indicate hazardous situations or important information:
Hazard levels:
DANGER: Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING: Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE: Indicates a situation which, if not avoided, could result in damage to property.
Other message levels:
Important: Indicates significant information which is essential for the product to function correctly.
Note: Indicates useful information which helps in getting the most out of the product.
What are the critical safety instructions for installing and using the AXIS T90D20 IR-LED?
WARNING: The Axis product shall be installed by a trained professional, and in compliance with local laws and regulations.
CAUTION: IR is emitted from this product. It can be harmful to the eyes. Avoid eye exposure. Use shielding or eye protection.
CAUTION: Possibly hazardous optical radiation is emitted from this product. It can be harmful to the eyes. Don’t stare at the operating lamp.
NOTICE:
• The Axis product shall be used in compliance with local laws and regulations.
• Store the Axis product in a dry and ventilated environment.
• Avoid exposing the Axis product to shocks or heavy pressure.
• Do not install the product on unstable poles, brackets, surfaces or walls.
• Use only applicable tools when installing the Axis product. Using excessive force with power tools could cause damage to the product.
• Do not use chemicals, caustic agents, or aerosol cleaners.
• Use a clean cloth dampened with pure water for cleaning.
• Use only accessories that comply with the technical specification of your product. These can be provided by Axis or a third party. Axis recommends using Axis power source equipment compatible with your product.
• Use only spare parts provided by or recommended by Axis.
• Do not attempt to repair the product yourself. Contact Axis support or your Axis reseller for service matters.
How should I transport the AXIS T90D20 IR-LED?
When transporting the AXIS T90D20 IR-LED, use the original packaging or equivalent to prevent damage to the product.
What are the main installation steps for the AXIS T90D20 IR-LED?
1. Make sure the package contents, tools and other materials necessary for the installation are in order.
2. Study the product overview.
3. Study the specifications.
4. Install the hardware.
What is included in the package for the AXIS T90D20 IR-LED?
• AXIS T90D Illuminator (1x)
• Pre-mounted diversion lens
• Separate diversion lens (2x)
• IP66 cable coupler (for PoE versions only)
• Printed materials (Installation Guide)
How do I install the AXIS T90D20 IR-LED hardware?
This guide describes an installation where the illuminator is controlled by the photocell. For AC/DC versions, only the red and black cables are required for installation.
1. If required, remove the screws and move the standard bracket to the top of the illuminator.
2. If required, loosen the screws and turn the bracket 90°.
3. Position the illuminator next to the camera and point it towards the camera’s field of view.
4. Connect the illuminator to the Power Source Equipment (PSE).
– For AC/DC versions: Connect the power cable from the PSE to the illuminator.
– For PoE versions: Connect the network cables from the PSE and the illuminator to the IP66 cable coupler.
Important: To maintain the IP66 rating, ensure the illuminator is correctly connected to the PSE.
CAUTION: Do not power the illuminator if the power cable is damaged. If done professionally, it is possible to shorten the power cable and replace the connector. If unable to repair, the illuminator must be disposed of and recycled.
How can I change the lens on the AXIS T90D20 IR-LED?
NOTICE: Handle the lens with care and do not touch the optical film.
The pre-mounted lens provides an angle of illumination of 35°. You can change the angle as follows:
• To alter to a 10° angle, remove the lens.
• To alter to a 60° angle, replace with a supplied lens.
• To alter to an 80° angle, replace with a supplied lens.
A lens for a 120° angle is available but not included with the product. All lenses have markings with the angle of illumination.
Important: To maintain the IP66 rating of the illuminator, make sure that the illuminator is correctly reassembled.
Follow these steps to change the lens:
1. Disconnect the power.
2. Remove the screws holding the baseplate using a 2.5 mm Allen/hex key.
3. Change to a diversion lens with the desired angle of illumination.
4. Place the baseplate in its original position and fasten the screws using a 2.5 mm Allen/hex key.
5. Point the illuminator towards the camera’s field of view.
What do the LED indicators on the AXIS T90D20 IR-LED signify?
The AXIS T90D20 IR-LED has two colored LED indicators on its base that provide operating and status information. There are two modes: Programming Mode and Normal Operating Mode. The illuminator automatically enters Programming Mode on power-up.
The LED status meanings are as follows:
• LHS LED solid green = Power on
• RHS LED flashing amber = Illuminator is in Programming Mode
• LHS LED solid red = Illuminator fault detected
• LHS LED flashing red = Voltage supply problem detected
Note: If any manual buttons are pressed, the illuminator automatically enters Normal Operating Mode 30 minutes after the last button press. After 7 days, the illuminator automatically enters Normal Operating Mode and the RHS LED will be unlit.
What should I know about the power connector and cable for the AXIS T90D20 IR-LED?
The illuminator uses either an AC/DC power connector or a network cable. The external cable cannot be replaced. If the cable is damaged and you are unable to shorten and re-use it, the illuminator must not be powered. The illuminator is suitable for both outdoor and indoor environments and is Class III for insulation.
What are the maximum output power specifications for the AXIS T90D series illuminators?
| Axis product | Max output power |
| AXIS T90D20 IR-LED | The supply to the units should be limited to/ fused at 2.5 A |
| AXIS T90D25 W-LED | The supply to the units should be limited to/ fused at 3.15 A |
| AXIS T90D30 IR-LED AXIS T90D35 W-LED AXIS T90D40 IR-LED |
The supply to the units should be limited to/ fused at 5 A |
| Axis product | Max output power |
| AXIS T90D20 PoE IR-LED AXIS T90D25 PoE W-LED AXIS T90D30 PoE IR-LED AXIS T90D35 PoE W-LED |
The supply to the units should be limited to 60 W |
Applies to PoE illuminators only: In order for the Power Supply Equipment (PSE) to conform to IEC/EN 60950-1, maximum power supplied to each illuminator must not exceed 60 W.
Applies to all illuminators: The LEDs (light source) of these illuminators are not replaceable. When the unit reaches its end of life, the whole illuminator shall be disposed of and recycled where possible.
How do I reset the AXIS T90D20 IR-LED to its factory default settings?
A full reset will restore the illuminator to its factory settings.
• Press and hold the two manual control buttons whilst recycling the power.
• Both Indicator LEDs will flash amber when the reset is completed.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD AXIS T90D20 IR-LED (01) PDF DOCUMENT