What safety instructions should be followed when handling the AXIS T90D30 POE IR-LED?
The following safety instructions should be adhered to when installing and operating the AXIS T90D30 POE IR-LED:
WARNINGS:
The Axis product shall be installed by a trained professional, and in compliance with local laws and regulations.
CAUTIONS:
IR is emitted from this product. It can be harmful to the eyes. Avoid eye exposure. Use shielding or eye protection.
Possibly hazardous optical radiation is emitted from this product. It can be harmful to the eyes. Don’t stare at the operating lamp.
Do not power the illuminator if the power cable is damaged. If done in a professional way, it is possible to shorten the power cable and replace the connector to repair the cable. If unable to repair the power cable, the illuminator must be disposed of and re-cycled.
NOTICES:
The Axis product shall be used in compliance with local laws and regulations.
Store the Axis product in a dry and ventilated environment.
Avoid exposing the Axis product to shocks or heavy pressure.
Do not install the product on unstable poles, brackets, surfaces or walls.
Use only applicable tools when installing the Axis product. Using excessive force with power tools could cause damage to the product.
Do not use chemicals, caustic agents, or aerosol cleaners.
Use a clean cloth dampened with pure water for cleaning.
Use only accessories that comply with the technical specification of your product. These can be provided by Axis or a third party. Axis recommends using Axis power source equipment compatible with your product.
Use only spare parts provided by or recommended by Axis.
Do not attempt to repair the product yourself. Contact Axis support or your Axis reseller for service matters.
When transporting the Axis product, use the original packaging or equivalent to prevent damage to the product.
What is included in the package with the AXIS T90D30 POE IR-LED?
The package for the AXIS T90D30 POE IR-LED contains the following items:
• AXIS T90D Illuminator (1x)
• Pre-mounted diversion lens
• Separate diversion lens (2x)
• IP66 cable coupler (for PoE versions only)
• Printed materials (Installation Guide)
How do I install the AXIS T90D30 POE IR-LED?
This guide describes an installation where the illuminator is controlled by the photocell. For more information about settings, options, and telemetry cables, refer to the User Manual.
1. If required, remove the screws and move the standard bracket to the top of the illuminator.
2. If required, loosen the screws and turn the bracket 90°.
3. Position the illuminator next to the camera and point it towards the camera’s field of view.
4. Connect the illuminator to the Power Source Equipment (PSE). For PoE versions, connect the network cables from the PSE and the illuminator to the IP66 cable coupler.
Important: To maintain the IP66 rating of the illuminator, ensure that it is correctly connected to the PSE.
How do I change the lens on the AXIS T90D30 POE IR-LED?
Handle the lens with care and do not touch the optical film. The pre-mounted lens provides an illumination angle of 35°. You can alter the angle as follows:
• To alter to a 10° angle, remove the lens.
• To alter to a 60° angle, replace with the supplied lens.
• To alter to an 80° angle, replace with the supplied lens.
A lens for a 120° angle is available but not included with the product. All lenses have markings indicating the angle of illumination.
To maintain the IP66 rating, ensure the illuminator is correctly reassembled by following these steps:
1. Disconnect the power.
2. Remove the screws holding the baseplate using a 2.5 mm allen/hex key.
3. Change to a diversion lens with the desired angle of illumination.
4. Place the baseplate in its original position and fasten the screws using a 2.5 mm allen/hex key.
5. Point the illuminator towards the camera’s field of view.
What do the LED indicators on the AXIS T90D30 POE IR-LED signify?
The AXIS T90D30 POE IR-LED has two colored LED indicators on its base that provide operating and status information. There are two modes: Programming Mode and Normal Operating Mode. On powering up, the illuminator automatically enters Programming Mode.
The LED status indicates the following:
• LHS LED solid green = Power on
• RHS LED flashing amber = Illuminator is in Programming Mode
• LHS LED solid red = Illuminator fault detected
• LHS LED flashing red = Voltage supply problem detected
Note: If any manual buttons are pressed, the illuminator automatically enters Normal Operating Mode 30 minutes after the last button press. After 7 days, the illuminator automatically enters Normal Operating Mode and the RHS LED will be unlit.
What are the power specifications for the AXIS T90D30 POE IR-LED?
The illuminator is Class III for insulation. The external cable cannot be replaced. If it is damaged and cannot be shortened and re-used, the illuminator must not be powered.
| Axis product | Max output power |
| AXIS T90D20 PoE IR-LED | The supply to the units should be limited to 60 W |
| AXIS T90D25 PoE W-LED | |
| AXIS T90D30 PoE IR-LED | |
| AXIS T90D35 PoE W-LED |
Applies to PoE illuminators only:
In order for the Power Supply Equipment (PSE) to conform to IEC/EN 60950-1, the maximum power supplied to each illuminator must not exceed 60 W.
Applies to all illuminators:
The LEDs (light source) of these illuminators are not replaceable. When the unit reaches its end of life, the whole illuminator shall be disposed of and re-cycled where possible.
How can I reset the AXIS T90D30 POE IR-LED to its factory default settings?
A full reset will restore the illuminator to its factory settings. To perform a full reset:
1. Press and hold the two manual control buttons whilst recycling the power.
2. Both Indicator LEDs will flash amber when the reset is completed.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD AXIS T90D30 POE IR-LED (01) PDF DOCUMENT