What are the safety hazard levels associated with the AXIS T90D25 POE W-LED?
The safety information for the AXIS T90D25 POE W-LED defines several hazard levels to be aware of:
DANGER: Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING: Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE: Indicates a situation which, if not avoided, could result in damage to property.
What are the main safety instructions for the AXIS T90D25 POE W-LED?
WARNING: The AXIS T90D25 POE W-LED must be installed by a trained professional, in compliance with local laws and regulations.
CAUTION: Possibly hazardous optical radiation is emitted from this product. It can be harmful to the eyes. Do not stare at the operating lamp.
NOTICE:
• The product shall be used in compliance with local laws and regulations.
• Store the product in a dry and ventilated environment.
• Avoid exposing the product to shocks or heavy pressure.
• Do not install the product on unstable poles, brackets, surfaces, or walls.
• Use only applicable tools when installing the product. Using excessive force with power tools could cause damage.
• Do not use chemicals, caustic agents, or aerosol cleaners.
• Use a clean cloth dampened with pure water for cleaning.
• Use only accessories that comply with the technical specification of your product. These can be provided by Axis or a third party. Axis recommends using Axis power source equipment compatible with your product.
• Use only spare parts provided by or recommended by Axis.
• Do not attempt to repair the product yourself. Contact Axis support or your Axis reseller for service matters.
What should I consider when transporting the AXIS T90D25 POE W-LED?
When transporting the AXIS T90D25 POE W-LED, use the original packaging or an equivalent to prevent damage to the product.
What is included in the package for the AXIS T90D25 POE W-LED?
The package for the AXIS T90D25 POE W-LED contains the following items:
• AXIS T90D Illuminator (1x)
• Pre-mounted diversion lens
• Separate diversion lens (2x)
• IP66 cable coupler (for PoE versions only)
• Printed materials, including the Installation Guide.
What are the main components of the AXIS T90D25 POE W-LED?
The main components of the AXIS T90D25 POE W-LED are:
Front/Back View:
1. Photocell
2. Network cable (for PoE versions)
3. Breather gland
Baseplate (must be removed to access controls):
1. Mounting bracket (pre-mounted)
2. Control button (left)
3. Left Hand Side LED (LHS)
4. Right Hand Side LED (RHS)
5. Control button (right)
How do I install the AXIS T90D25 POE W-LED?
This guide describes an installation where the illuminator is controlled by the photocell. For installation using a compatible bracket, refer to the guide delivered with the mounting bracket.
Follow these installation procedures:
1. If required, remove the screws and move the standard bracket to the top of the illuminator.
2. If required, loosen the screws and turn the bracket 90°.
3. Position the illuminator next to the camera and point it towards the camera’s field of view.
4. Connect the illuminator to the Power Source Equipment (PSE). For PoE versions, connect the network cables from the PSE and the illuminator to the IP66 cable coupler.
Important: To maintain the IP66 rating of the illuminator, ensure it is correctly connected to the PSE.
CAUTION: Do not power the illuminator if the power cable is damaged. If done professionally, it’s possible to shorten and replace the connector. If not, the illuminator must be disposed of and recycled.
How do I change the lens on my AXIS T90D25 POE W-LED?
NOTICE: Handle the lens with care and do not touch the optical film.
The pre-mounted lens provides a 35° angle of illumination. You can alter this angle:
• To alter to a 10° angle, remove the lens.
• To alter to a 60° angle, replace with a supplied lens.
• To alter to an 80° angle, replace with a supplied lens.
A 120° lens is available but not included. All lenses have markings indicating the angle of illumination.
Important: To maintain the IP66 rating, ensure the illuminator is correctly reassembled.
1. Disconnect the power.
2. Remove the screws holding the baseplate using a 2.5 mm allen/hex key.
3. Change to a diversion lens with the desired angle of illumination.
4. Place the baseplate in its original position and fasten the screws using a 2.5 mm allen/hex key.
5. Point the illuminator towards the camera’s field of view.
What do the LED indicators on the AXIS T90D25 POE W-LED signify?
The AXIS T90D25 POE W-LED has two colored LED indicators on its base that provide operating and status information. On power-up, the illuminator automatically enters Programming Mode. The statuses are:
• LHS LED solid green: Power on
• RHS LED flashing amber: Illuminator is in Programming Mode
• LHS LED solid red: Illuminator fault detected
• LHS LED flashing red: Voltage supply problem detected
Note: If any manual buttons are pressed, the illuminator automatically enters Normal Operating Mode 30 minutes after the last button press. After 7 days, the illuminator automatically enters Normal Operating Mode and the RHS LED will be unlit.
What are the power specifications for the AXIS T90D25 POE W-LED?
For the AXIS T90D25 POE W-LED, the supply to the units should be limited to 60 W. In order for the Power Supply Equipment (PSE) to conform to IEC/EN 60950-1, the maximum power supplied to each illuminator must not exceed 60 W.
How do I reset the AXIS T90D25 POE W-LED to factory default settings?
To perform a full reset and restore the AXIS T90D25 POE W-LED to factory settings, follow these steps:
1. Press and hold the two manual control buttons whilst recycling the power.
2. Both Indicator LEDs will flash amber when the reset is completed.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD AXIS T90D25 POE W-LED (01) PDF DOCUMENT