What are the safety recommendations for installing the WESTERMO SDW-532-MM-LC2?
Before installation, you should:
- Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit.
- This unit should only be installed by qualified personnel.
- This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only.
- The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations.
- This unit uses convection cooling. To avoid obstructing the air flow around the unit, follow the spacing recommendations (see Installation section).
What are the safety recommendations before mounting, using, or removing the WESTERMO SDW-532-MM-LC2?
Before mounting, using or removing this unit:
- Prevent access to hazardous voltage by disconnecting the unit from power supply.
- Warning! Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply.
What is the safety warning regarding the Class 1 Laser Product feature of the WESTERMO SDW-532-MM-LC2?
Class 1 Laser Product: Do not look directly into fibre optical fibre port or any connected fibre although this unit is designed to meet the Class 1 Laser regulations.
What care recommendations should be followed for the WESTERMO SDW-532-MM-LC2 to maintain full operation and fulfill warranty obligations?
Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations.
- This unit must not be operating with removed covers or lids.
- Do not attempt to disassemble the unit. There are no user serviceable parts inside.
- Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards.
- Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.
- Do not paint the unit. Paint can clog the unit and prevent proper operation.
- Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels.
- Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged.
- Fibre connectors are supplied with plugs to avoid contamination inside the optical port. As long as no optical fibre is mounted on the connector, e.g. for storage, service or transportation, should the plug be applied.
What special treatment is required for fibre optic handling when using the WESTERMO SDW-532-MM-LC2?
Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If the fibre will be disconnected from the modem the protective hood on the transmitter/receiver must be connected. The protective hood must be kept on during transportation. The fibre optic cable must also be handle the same way.
How should optical connectors on the WESTERMO SDW-532-MM-LC2 be cleaned?
In the event of contamination, the optical connectors should be cleaned by the use of forced nitrogen and some kind of cleaning stick.
Recommended cleaning fluids:
- Methyl-, ethyl-, isopropyl- or isobutyl-alcohol
- Hexane
- Naphtha
What maintenance is required for the WESTERMO SDW-532-MM-LC2?
No maintenance is required, as long as the unit is used as intended within the specified conditions.
How should the WESTERMO SDW-532-MM-LC2 be disposed of?
This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it. It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment.
By ensuring this product is disposed of correctly, you will help to reduce hazardous substances and prevent potential negative consequences to both environment and human health, which could be caused by inappropriate disposal.
What are the isolation specifications between interfaces for the WESTERMO SDW-532-MM-LC2?
| Power Interface to all other | 2.8 kV DC 2.0 kV RMS @ 50 Hz and 60 s duration |
| TX signal Interface to all other | 2.1 kV DC 1.5 kV RMS @ 50 Hz and 60 s duration |
| TX shield Interface to all other | 1.5 kV DC 1.0 kV RMS @ 50 Hz and 60 s duration |
What are the environmental conditions for temperature, relative humidity, and altitude for the WESTERMO SDW-532-MM-LC2?
| Temperature, operating | -25 to +60°C (SDW-532) |
| Temperature, storage and transportation | -25 to +70°C |
| Relative humidity, operating | 5 to 95% (non-condensing) |
| Relative humidity, storage and transportation | 5 to 95% (condensation allowed outside packaging) |
| Altitude, operating | 2000 m/70 kPa |
What are the mechanical specifications for the WESTERMO SDW-532-MM-LC2 regarding dimension, weight, mounting, and degree of protection?
| Dimension (W x H x D) | 35 x 121 x 119 mm |
| Weight | 0.2 kg |
| Mounting | DIN-rail |
| Degree of protection | IP21 |
How is the WESTERMO SDW-532-MM-LC2 configured?
Configuration is auto configured (auto-negotiation) or done by manually setting of speed and duplex of individual TX port, by DIP-switches.
Port mirror function is possible to set with DIP-switch. With the port mirror function active the switch will copy all outgoing traffic to port 1. This can be used to monitor all traffic going out from the switch. Packets may be discarded if the total throughput exceeds the port speed of port 1.
What are the fibre optic power budget specifications for the WESTERMO SDW-532-MM-LC2 (Multimode MM-xx2)?
| Model | Multimode MM-xx2 |
|---|---|
| Transmitted wavelength | 1310 nm |
| Min. output power, transmitter | -19 dBm |
| Max. output power, transmitter | -12 dBm |
| Input sensitivity, receiver | -31 dBm |
| Min. power budget | 12 dBm |
| Max. power budget | 19 dBm |
| Recommended fibre cable and core / cladding diameter | 50/125 62.5/125 |
What are the normal attenuation values in connectors and splices for the WESTERMO SDW-532-MM-LC2?
| Type | Normal attenuation |
|---|---|
| Connector | 0.2 – 0.4 dBm |
| Fusion splice | 0.1 dBm |
| Mechanical splice | 0.2 dBm |
What are the power interface specifications for the WESTERMO SDW-532-MM-LC2?
| Rated voltage | 12-48 VDC, polarity protected |
| Operating voltage | 9.6 – 57.6 VDC |
| Rated current (@12VDC power input) | 450 mA |
| Rated frequency | DC |
| Connection | Detachable screw terminal |
| Connector size | 0.2 – 2.5 mm² (AWG 24-12) |
What are the Ethernet TX interface specifications for the WESTERMO SDW-532-MM-LC2?
| Electrical specification | IEEE std 802.3. 2000 edition |
| Data rate | 10 Mbit/s or 100 Mbit/s, manual or auto |
| Duplex | Full or half, manual or auto |
| Connection | SC, ST or LC |
| Circuit type | Optical |
| Transmission range | 100 m |
What are the Ethernet FX interface specifications for the WESTERMO SDW-532-MM-LC2?
| Electrical specification | IEEE std 802.3. 2000 edition |
| Data rate | 10 Mbit/s or 100 Mbit/s, manual or auto |
| Duplex | Full or half, manual or auto |
| Connection | SC, ST or LC |
| Circuit type | Optical |
| Transmission range | 100 m |
How are the power connections wired on the WESTERMO SDW-532-MM-LC2?
The WESTERMO SDW-532-MM-LC2 supports redundant power connection. The positive input are +VA and +VB, the negative input for both supplies are COM. The power is drawn from the input with the highest voltage.
| 3-pos screw terminal | Description | Power |
|---|---|---|
| 1 | COM | 0V |
| 2 | +VA | A: 9.6 – 57.6 VDC |
| 3 | +VB | B: 9.6 – 57.6 VDC |
What are the pin assignments for the Ethernet TX connection (RJ-45 connector) on the WESTERMO SDW-532-MM-LC2?
The Ethernet TX connection supports automatic MDI/MDI-X crossover. CAT 5 cable is recommended. Unshielded (UTP) or shielded (STP) connector might be used.
| Contact | Signal Name | Direction | Description/Remark |
|---|---|---|---|
| 1 | TD+ | In/Out | Transmitted/Received data |
| 2 | TD− | In/Out | Transmitted/Received data |
| 3 | RD+ | In/Out | Transmitted/Received data |
| 4 | – | – | – |
| 5 | – | – | – |
| 6 | RD− | In/Out | Transmitted/Received data |
| 7 | – | – | – |
| 8 | – | – | – |
| Shield | – | – | HF-connected |
What type of fibre optic connection is used for FX LC Multi- or single mode on the WESTERMO SDW-532-MM-LC2?
The Ethernet FX connection uses 1300 nm singlemode fibre transceiver with LC-connector. The dust protection plug shall be mounted when no fibre is connected.
What do the LED indicators on the WESTERMO SDW-532-MM-LC2 signify?
At power on the PWR flashes during initialising. The indicators (LED) are Power (PWR), Link (LINK) of every port, and Speed (SPD) and duplex (DPX) of TX ports.
| LED | Status | Indication of |
|---|---|---|
| PWR | ON | Internal power, initialising OK |
| Slow flash | Initialisation progressing | |
| Fast flash | Initialisation error | |
| LINK | OFF | No Ethernet link |
| ON | Good Ethernet link | |
| Flash | Ethernet data is transmitted or received, traffic indication | |
| SPD (TX only) | OFF | 10 Mbit/s |
| ON | 100 Mbit/s | |
| DPX (TX only) | OFF | Half duplex |
| ON | Full duplex |
Where are the DIP switches located on the WESTERMO SDW-532-MM-LC2, and what is the caution when accessing them?
DIP-switches are accessible under the lid on top of the unit. DIP-switches are used to configure the unit.
Warning! Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap), before the lid on top/front of the unit is removed.
Warning! Do not open connected equipment. Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections.
When do DIP switch settings take effect on the WESTERMO SDW-532-MM-LC2?
When configuration via DIP-switches, the settings of DIP-switches configure the unit only after a reboot (power off/on).
What must be observed when configuring the DIP-switches on the WESTERMO SDW-532-MM-LC2?
- Speed and duplex setting only valid when auto-negotiation is disabled.
- When monitoring selected all outgoing packets from the switch is also copied to the port 1.
- Speed and duplex switch settings are ignored for FX ports.
- If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X configuration.
How are the DIP switches configured for Port 1 settings on the WESTERMO SDW-532-MM-LC2?
| Setting | DIP-switch S1 (Pins 1-8) |
|---|---|
| Auto-negotiation and auto MDI/MDI-X disabled | Pin 1 ON, Pins 2-8 OFF |
| Auto-negotiation and auto MDI/MDI-X enabled | Pin 1 OFF, Pins 2-8 OFF |
| 10 Mbit/s speed selected | Pin 2 ON, Pins 1, 3-8 OFF |
| 100 Mbit/s speed selected | Pins 1-2 OFF, Pin 3 ON, Pins 4-8 OFF |
| Half duplex selected | Pins 1-3 OFF, Pin 4 ON, Pins 5-8 OFF |
| Full duplex selected | Pins 1-4 OFF, Pin 5 ON, Pins 6-8 OFF |
How are the DIP switches configured for Port 2 settings on the WESTERMO SDW-532-MM-LC2?
| Setting | DIP-switch S1 (Pins 1-8) |
|---|---|
| Auto-negotiation and auto MDI/MDI-X disabled | Pin 6 ON, Pins 1-5, 7-8 OFF |
| Auto-negotiation and auto MDI/MDI-X enabled | Pins 1-6 OFF, Pins 7-8 OFF |
| 10 Mbit/s speed selected | Pin 7 ON, Pins 1-6, 8 OFF |
| 100 Mbit/s speed selected | Pins 1-7 OFF, Pin 8 ON |
| Half duplex selected | Pins 1-4, 6-8 OFF, Pin 5 ON |
| Full duplex selected | Pins 1-5, 7-8 OFF, Pin 6 ON (This seems contradictory based on the image, referring to the Port 2 settings diagram, Pins 1, 2, 3, 4, 5, 6, 7, 8 in S1. Assuming the diagram for Port 2 reflects the same bit sequence logic as Port 1, for Full duplex selected: S1: Pin 5 ON, all others OFF for Port 1. For Port 2, Full Duplex selected: S1: Pin 6 ON, all others OFF – based on the diagram.) |
How are the DIP switches configured for Port 3 settings on the WESTERMO SDW-532-MM-LC2?
| Setting | DIP-switch S1 (Pins 1-8) |
|---|---|
| Auto-negotiation and auto MDI/MDI-X disabled | Pin 1 ON, Pins 2-8 OFF |
| Auto-negotiation and auto MDI/MDI-X enabled | Pin 1 OFF, Pins 2-8 OFF |
| 10 Mbit/s speed selected | Pin 2 ON, Pins 1, 3-8 OFF |
| 100 Mbit/s speed selected | Pins 1-2 OFF, Pin 3 ON, Pins 4-8 OFF |
| Half duplex selected | Pins 1-3 OFF, Pin 4 ON, Pins 5-8 OFF (S2 is used for this setting: Pin 1 ON, Pins 2-8 OFF) |
| Full duplex selected | Pins 1-4 OFF, Pin 5 ON, Pins 6-8 OFF (S2 is used for this setting: Pin 2 ON, Pins 1, 3-8 OFF) |
How are the DIP switches configured for Port 4 settings on the WESTERMO SDW-532-MM-LC2?
These settings are ignored when using the WESTERMO SDW-532-MM-LC2 (SDW-532 models).
How are the DIP switches configured for Port mirroring settings on the WESTERMO SDW-532-MM-LC2?
| Setting | DIP-switch S2 (Pins 1-5) |
|---|---|
| No monitoring selected | Pins 1-5 OFF |
| Monitoring selected | Pin 1 ON, Pins 2-5 OFF |
How are the DIP switches configured for Flow control settings on the WESTERMO SDW-532-MM-LC2?
| Setting | DIP-switch S3 (Pins 1-4) |
|---|---|
| Flow control selected | Pins 1-4 OFF |
| No flow control selected | Pin 1 ON, Pins 2-4 OFF |
How are the DIP switches configured for Factory settings on the WESTERMO SDW-532-MM-LC2?
| Setting | DIP-switch S1 (Pins 1-8) | DIP-switch S2 (Pins 1-8) | DIP-switch S3 (Pins 1-4) |
|---|---|---|---|
| Factory settings | Pins 1, 5, 6 ON, Pins 2, 3, 4, 7, 8 OFF | Pins 1, 2, 3, 4, 5, 6, 7, 8 OFF | Pins 1, 2, 3, 4 OFF |
What steps should be taken before mounting or removing the WESTERMO SDW-532-MM-LC2?
Before mounting or removing the unit:
- Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap).
- Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections.
How should the WESTERMO SDW-532-MM-LC2 be mounted?
This unit should be mounted on 35 mm DIN-rail which is horizontally mounted on a wall or cabinet backplate.
This unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules. Recommended spacing 25 mm (1.0 inch) above/below and 10 mm (0.4 inches) left/right the unit. The 10 mm spacing left/right is recommended for full operating temperature range.
Mounting is done by snapping the unit onto the DIN-rail.
How is the WESTERMO SDW-532-MM-LC2 removed from its mounting?
Press down the black support at the back of the unit to remove it.