FREE ENGLISH VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U (01) PDF DOCUMENT.
FREE ENGLISH VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U (01) PDF USER GUIDE.
FREE ENGLISH VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U (01) PDF USER MANUAL.
FREE ENGLISH VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U (01) PDF OWNER GUIDE.
FREE ENGLISH VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U (01) PDF OWNER MANUAL.
FREE ENGLISH VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U (01) PDF REFERENCE GUIDE.
FREE ENGLISH VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U (01) PDF REFERENCE MANUAL.
FREE ENGLISH VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What are the main components and features of the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U?
The components and features are identified by numbers on the rear panel of the unit. The following table describes each component:
| Item | Description |
|---|---|
| 1 | Input Circuit Breaker |
| 2 | AC Input |
| 3 | USB Communication Port |
| 4 | Vertiv™ Liebert® IntelliSlot™ Port |
| 5 | Programmable Receptacles (white) |
| 6 | Non-programmable receptacles |
| 7 | Emergency Power Off (EPO) connector |
| 8 | Output Circuit Breakers |
What items are included in the package for the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U?
Inspect the contents of the box. If anything is missing or damaged, contact Vertiv. The following items are included in the package for all models:
• Vertiv™ Edge
• Accessory Package includes:
• Quick Install Guide
• Safety and Regulatory Statements
• USB type A to B cable
• Rail kit box
• Left and right rail set
• 12 x Rail kit screws (M5 x 14mm)
• 4 x Tower feet
• 2 x UPS rack ears with 8 x rack ear screws (M4 x 8mm)
• 2 x IEC C13 to C14 output cables
For the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U model, the following is also included:
• Input power cable IEC Schuko to IEC C19
• Input power cable BS1362 to IEC C19
• Input power cable AUS to IEC C19
Where is the proper location to install the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U?
Install the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U in a temperature-controlled environment that is free of corrosive and conductive contaminants. Avoid locations near heat or water sources and exposed to direct sunlight. For proper air flow, leave four inches of clearance on the front and back of the UPS.
How do I install the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U in a rack?
The VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U may be installed in either a rack or tower configuration. For rack installation, follow these steps:
1. Attach a rack ear with four rack ear screws to the front right and left sides of the UPS.
2. Install the rear member of the rail onto the rack with one rail kit screw on the top and one on the bottom. Loosely tighten the screws (finger tight). Slide the front member of the rail to the front of the rack and secure the two bottom holes to the rack with two rail kit screws. Tighten all screws. Repeat for the second rail.
3. Place the UPS with assembled rack ears onto the rail supports. The batteries may be temporarily removed for easier installation.
4. Attach two rail kit screws to each UPS rack ear and rail to secure the UPS to the rack.
How do I install the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U in a tower configuration?
For tower installation of the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U, follow these steps:
1. Connect two tower feet together. Repeat to assemble two tower stands.
2. Place the UPS in the tower stands 70 mm from each edge of the UPS.
How should I connect loads to my VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U?
The UPS has non-programmable and programmable rear outlets. Plug your critical equipment (such as computer, monitors, etc.) into the non-programmable outlets and your less critical equipment (less often used peripherals) into the programmable outlets. Do not plug in the UPS input power until after all load and optional connections have been made.
How do I connect an optional network communication card to the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U?
Advanced monitoring and simple control of the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U can be done with the use of a Vertiv™ Liebert® IntelliSlot™ Communications card.
1. Remove the two screws and protective cover on the rear panel network communications port.
2. Insert the card into the port and secure it with the screws. Refer to the documentation with the card for cable connection and operation.
How do I use the optional USB Communication Connection on the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U?
Basic monitoring of the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U and unattended controlled shutdown of your computer in case of a power failure can be done using the Vertiv™ Power Assist software via the USB port.
How do I set up the Emergency Power Off (EPO) connection on the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U?
To comply with national and local wiring codes and regulations, the EPO connector internally disconnects all power sources to connected equipment. To use this feature, remove the factory installed jumper on the rear panel EPO connector and connect to active-open contacts that are normally closed but open during an emergency power off event. Operating logic may be reversed in the settings menu. If you do not use the EPO connector, leave the factory installed jumper in place and the default (active open) EPO setting in the settings menu.
How do I connect the AC input power to the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U?
Ensure that all the loads are first powered off. Connect to an input power supply/wall outlet that is properly protected by a circuit breaker in accordance with national and local electrical codes. The input receptacle must be grounded. Once the UPS is plugged into the wall outlet, it begins charging the battery.
What is the procedure for starting up the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U?
Plug the UPS input plug into a stable 230VAC source. The LCD display turns on and the batteries begin charging. Press and hold the ENTER/ button for two seconds until the output turns on. The UPS is in Battery Self Test mode for 10 seconds. After a successful battery self test, the UPS is in On Mode.
How do I shut down the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U?
Press and hold the ENTER/ button for two seconds and use the popup window to confirm that the UPS should be turned off. This will turn the outlets off. Disconnect the input power.
How do I perform a full shutdown of the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U?
After turning the UPS off, remove input power, then remove the front bezel and disconnect the battery connector. Replace the front bezel. The unit is now fully shut down.
What safety precautions should I follow for maintenance and battery replacement of the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U?
Although the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U is designed and manufactured to ensure personal safety, improper use can result in electrical shock or fire. To ensure safety, observe the following precautions:
• Turn off and unplug the UPS before cleaning it.
• Clean the UPS with a dry cloth. Do not use liquid or aerosol cleaners.
• Never block or insert any objects into the UPS ventilation holes or openings.
• Do not place the UPS power cord where it might be damaged.
IMPORTANT: Before you proceed with battery replacement, please review the battery safety precautions.
What are the guidelines for charging the battery of the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U?
The batteries are lithium ion and should be kept charged to attain their design life. The VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U charges the batteries continuously when it is connected to the utility input power. If the unit will be stored for a long time, it is recommended to connect the UPS to input power for at least three hours every four to six months to ensure full recharge of the batteries.
How do I replace the battery in the VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U?
IMPORTANT: Before you proceed, please review the battery safety precautions.
NOTE: Replace the battery with the same type and number as originally installed.
The VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U battery can be hot-swapped and may be replaced while the UPS is on and plugged in. As long as the utility power is available, power to the outlets will remain. Follow these steps:
1. Removing the front panel: Remove the front bezel by pulling firmly until the snaps release.
2. Disconnecting the battery wires: Disconnect the battery connector by squeezing the ends and pulling apart.
3. Removing the battery box: Remove the four screws and the metal battery cover. Pull the battery kit out.
4. Installing the new battery: Orient the connector and the new battery in the same way as the original battery, then slide them into the UPS. Reinstall the metal battery cover.
5. Reconnecting the battery and front panel: Reconnect the battery connectors. Snap the front bezel back on.
How do I reset the battery statistics on my VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U after a replacement?
Navigate through the menu to Settings > Battery > Replace Battery and confirm battery replacement.
NOTE: Default password is 111111.
How should I dispose of the old battery from my VERTIV EDGE LITHIUM-ION EDGELI-3000IRT2U?
Properly dispose of old batteries at an appropriate recycling center or return them to Vertiv in the packing material for the replacement batteries.