FREE ENGLISH VERTIV LIEBERT PSA5-700MT120 (01) PDF DOCUMENT.
FREE ENGLISH VERTIV LIEBERT PSA5-700MT120 (01) PDF USER GUIDE.
FREE ENGLISH VERTIV LIEBERT PSA5-700MT120 (01) PDF USER MANUAL.
FREE ENGLISH VERTIV LIEBERT PSA5-700MT120 (01) PDF OWNER GUIDE.
FREE ENGLISH VERTIV LIEBERT PSA5-700MT120 (01) PDF OWNER MANUAL.
FREE ENGLISH VERTIV LIEBERT PSA5-700MT120 (01) PDF REFERENCE GUIDE.
FREE ENGLISH VERTIV LIEBERT PSA5-700MT120 (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH VERTIV LIEBERT PSA5-700MT120 (01) PDF REFERENCE MANUAL.
FREE ENGLISH VERTIV LIEBERT PSA5-700MT120 (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH VERTIV LIEBERT PSA5-700MT120 (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD VERTIV LIEBERT PSA5-700MT120 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What safety information is important for the VERTIV LIEBERT PSA5-700MT120?
This manual contains important safety instructions that must be followed during the installation and maintenance of the UPS and batteries. Read the manual and all safety and regulatory information thoroughly before attempting to install, connect to supply, or operate this UPS.
What are the functions of the front and rear panel controls and features on the VERTIV LIEBERT PSA5-700MT120?
| ITEM | DESCRIPTION |
|---|---|
| 1 | Power button. |
| 2 | Silence-alarm button. |
| 3 | Scroll button. To scroll through the LCD-display parameters. |
| 4 | LCD display. |
| 5 | USB charging ports, 5 V/2.1 A max. combined. |
| 6 | Surge-protected only receptacles. |
| 7 | Battery-backed and surge-protected receptacles. |
| 8 | USB communication port (Type B). |
| 9 | RJ11/45 connectors for phone/fax/modem or network surge protection. |
| 10 | Coax connectors for cable-TV or cable-modem or DSS-receiver surge protection. |
| 11 | Input Circuit Breaker. |
| 12 | Input power cord (NEMA 5-15P). |
What is included in the box with the VERTIV LIEBERT PSA5-700MT120?
USB cable; one 2 m (6.5 ft) long
Coax cable; one 1 m (3 ft) long
Quick Installation Guide
Safety and Regulatory Guidelines
What should I do when unpacking the VERTIV LIEBERT PSA5-700MT120?
Unpack the UPS and conduct the following checks:
Inspect the UPS for shipping damage. If any shipping damage is found, report it to the carrier and your local dealer or your Vertiv representative immediately.
Check the accessories included in the packaging list. If there is any discrepancy, contact your local dealer or your Vertiv representative immediately.
What are the environmental and clearance requirements for installing the VERTIV LIEBERT PSA5-700MT120?
Installation Environment:
Install the UPS indoors in a controlled environment, where it cannot be accidentally turned Off. The installation environment should meet the specifications listed in the Specifications section.
Place it in an area of unrestricted air-flow around the unit, away from water, flammable liquids, gases, corrosives, and conductive contaminants. Avoid direct sunlight.
The socket outlet should be nearby and easily accessible.
This UPS is not for use in a computer room as defined in the standard for the Protection of Electronic Computer/Data Processing Equipment ANSI/NFPA 75.
NOTE: Operating the UPS in temperatures above 77°F (25°C) reduces battery life.
Installation Clearances:
Maintain at least 4 in (100 mm) clearance in the front and rear. Do not obstruct the air inlets on the front panel and rear panel. Blocking the air inlets reduces ventilation and heat dissipation, shortening the service life of the UPS.
How do I connect loads to the VERTIV LIEBERT PSA5-700MT120?
The UPS has 5 battery-backed outlets and surge-protected receptacles and 5 surge-protected-only receptacles. Plug your critical equipment (such as computer, monitors, etc.) into the battery-backed receptacles and your less-critical equipment (such as printers and other less-often used peripherals) into the surge-only receptacles.
How do I connect network, telephone, or TV protection on the VERTIV LIEBERT PSA5-700MT120?
Network/Telephone: Protection from electrical surges to your computer network or telephone is provided. Use the network/telephone surge-protection ports on the rear panel. Connect the “IN” port to the line from the wall jack and the “OUT” port to your device port. Use of this feature is not required for proper operation of the UPS.
Cable/DSS: Surge protection for your cable modem, DSS Receiver, or cable-TV connection is also provided using the coax surge-protection ports on the rear panel. Connect the “IN” port to the line from the wall jack and the “OUT” port to your device port. Use of this feature is not required for proper operation of the UPS.
How do I use the USB communication connection on the VERTIV LIEBERT PSA5-700MT120?
You can connect the PSA5 to a computer via USB allowing unattended, controlled-shutdown of your computer in case of UPS input power failure. The UPS works with the computer running software built-in within the Microsoft® Windows® operating system. Use of this feature is not required for proper operation of the UPS. To use this feature, plug the provided USB cable into USB Type-B port located on the rear panel of the UPS and the other end into an open USB port on your computer.
How do the USB charging ports work on the VERTIV LIEBERT PSA5-700MT120?
The PSA5 has two easily-accessible, front-panel USB Type-A charging ports. These ports charge phones or other small USB powered devices. The ports provide up to 2.1 A of charge total shared dynamically between both ports. You may plug devices into these ports at any time during installation and operation.
NOTE: Charging is only available when the UPS is in an On mode.
How do I connect the AC input for the VERTIV LIEBERT PSA5-700MT120?
Ensure that all the loads are first powered off. Connect to an input-power supply/wall outlet that is properly protected by a circuit breaker in accordance with national and local electrical codes. The input receptacle must be grounded.
Once the UPS is plugged into the wall outlet, it begins charging the battery.
NOTE: While every precaution has been taken to ensure that the battery is in good condition, we recommend allowing the UPS to be plugged into AC input and to charge the battery for at least 12 hours prior to providing full back-up time protection for any utility-power abnormality.
What are the different modes of operation for the VERTIV LIEBERT PSA5-700MT120?
NOTE: In all of the following modes, including Off mode: The UPS always provides surge protection and input-breaker protection to the 5 battery backed-up outlets and the 5 surge-only outlets. The UPS does not need to be On to provide this protection. The surge-only outlets always have the same voltage level as the UPS input voltage, even when the UPS is Off. The surge-only outlets are not voltage regulated, battery backed-up, or switched by the UPS.
Off Mode: The UPS input is plugged into a stable, nominal source, but the battery-backed-up outlets are turned off. The internal batteries are charging. The surge-only outlets will still have power.
On/Normal Mode: The UPS input is plugged into a stable, nominal source, and the battery-backed-up outlets are turned on. The internal batteries are charging.
On/Automatic Voltage Regulation (AVR) Mode: The UPS input is plugged in, but the voltage source is abnormally low (brown-out). The UPS automatically corrects the low voltage and allows the battery-backed-up outlets to be on with the normal, expected voltage. The internal batteries are charging. The surge-only outlets will have the abnormally-low input voltage and equipment plugged into these outlets may not work.
On/Battery Mode: The UPS input is not plugged in, or the voltage source has become extremely low or high and unusable. The UPS automatically switches to the internal battery to provide normal, usable voltage to the battery-backed-up outlets. The surge-only outlets will not have power.
Fault Mode: An error or fault condition has occurred. The battery-backed-up outlets are shut off. The surge-only outlets may still have power if the UPS input is plugged in.
How does the Battery Self-test Mode work on the VERTIV LIEBERT PSA5-700MT120?
The UPS enters a cycle of approximately 10 seconds during which it tests the internal battery. The battery-backed-up outlets are still temporarily powered by the internal battery. Self-test mode occurs at the following instances:
At start-up turning the UPS On.
Automatically every 8 weeks as a self-check.
Manually by pressing and holding the power button for 3 seconds when the unit is On.
How do the front panel buttons on the VERTIV LIEBERT PSA5-700MT120 work?
| ITEM | DESCRIPTION |
|---|---|
| Power button |
Press-and-hold for 1 second to cycle between On and Off mode. Press-and-hold for 3 seconds to enter Battery Self-test mode. Press quickly to wake the display. |
| Silence Battery-mode Alarm button |
Press-and-hold for 2 seconds during On/Battery mode to mute the battery-alarm beep. Press quickly to wake the display. |
| Scroll button |
When the UPS is On, press to cycle through UPS operating parameters. Press quickly to wake the display. |
What do the display panel icons and indicators mean on the VERTIV LIEBERT PSA5-700MT120?
NOTE: The display automatically powers-off to conserve power. However, the display remains on when there is a warning or fault to call attention to the event.
| ITEM | DESCRIPTION |
|---|---|
| 1 | Battery mode when lit. |
| 2 | Replace battery warning when lit. See Warnings for more details. |
| 3 | AC-mode:
On solid = Normal mode. Flashing = Automatic Voltage Regulation mode. |
| 4 | Output-overload warning when flashing. See Warnings for more details. |
| 5 | Site-wiring fault warning when lit. See Warnings for more details. |
| 6 | Output-load level graph in 25% increments. |
| 7 | Numeric display of UPS operational parameters:
VAC = input/output voltage Hz = input/output frequency KW = output power MIN = estimated battery back-up time |
| 8 | Fault when lit. Fault codes indicated: E01, E02, E03, E04, E05, E06. See Faults for more details. |
| 9 | Battery-capacity graph in 25% increments. |
| 10 | Battery-mode alarm muted when lit. See Audible-tone Indicators for more details. |
What do the audible tones and beeps mean on the VERTIV LIEBERT PSA5-700MT120?
| TYPE | INDICATES |
|---|---|
| 1 beep every 10 seconds | Battery mode |
| 2 beeps every second | UPS warning |
| 2 beeps every 5 seconds | Low-battery warning |
| 3 beeps every 30 seconds | Replace-battery warning |
| Constant, solid tone | UPS fault |
| 3-second tone followed by 2 beeps | Power-on in battery self-test mode |
| 1 long tone | Power off |
| 3 beeps | Manual battery self-test |
How do I troubleshoot warnings on the VERTIV LIEBERT PSA5-700MT120?
The UPS has three early-warning indicators that allow the UPS to function normally for a short period before the outputs are shut-off.
| AUDIBLE TONE | DESCRIPTION | SUGGESTED TROUBLESHOOTING |
|---|---|---|
| 1 beep every second | Output-overload. The load devices plugged-in to the UPS output are drawing more power than the UPS rating. | Reduce the load to below the UPS rating in the specifications table. |
| Constant, solid tone | Site-wiring fault. Problem detected with the outlet wiring to which the AC input of the UPS is connected. | Power-off the UPS and contact an electrician to correct the wiring. Possible causes are line and neutral are reversed or there is no ground conductor. |
| 3 beeps every 30 seconds | The battery is weak or damaged. | Charge the UPS battery for at least 12 hours, or replace the battery. |
How do I troubleshoot fault codes on the VERTIV LIEBERT PSA5-700MT120?
The UPS displays fault codes when it detects a problem and automatically shuts-off output power.
| FAULT CODE | DESCRIPTION | SUGGESTED TROUBLESHOOTING |
|---|---|---|
| E01 | Output short circuit. | Turn-off the UPS, disconnect all loads, and restart the UPS.
If the fault is still active, contact Vertiv technical support for a replacement. If the fault is no longer active, plug in equipment one at a time to locate the device with the short circuit. |
| E02 | Output overload exceeded warning time, and output is shut off. | Turn-off the UPS, disconnect all loads, and restart the UPS. Plug in equipment one at a time and make sure not to exceed the UPS rating for load capacity. |
| E03 | Un-used. | Un-used. |
| E04 | Internal inverter circuitry failure during start-up self-test. | Turn-off the UPS and call Vertiv technical support for a replacement unit. |
| E05 | Battery-charge failure. | Turn-off the UPS and call Vertiv technical support for a replacement unit. |
| E06 | Internal battery is dead or damaged. | Charge the UPS for at least 12 hours or replace the battery. |
How do I perform a normal start-up of the VERTIV LIEBERT PSA5-700MT120?
With the UPS connected to AC input, press-and-hold the power button for 1 second. A long tone and 2 short beeps sound while the UPS is in battery self-test mode for a few seconds. After a successful self-test, the outlets are on.
How do I shut down the VERTIV LIEBERT PSA5-700MT120?
Normal Shut-down
1. Press-and-hold the power button for 1 second. The outlets are turned off.
2. Disconnect AC-input power.
3. Remove the battery cover and disconnect the battery connector.
Full Shut-down
1. Press-and-hold the power button for 1 second. The outlets are turned off.
2. Disconnect AC-input power.
3. Remove the battery cover and disconnect the battery connector. The unit is fully shut down.
What are the maintenance precautions for the VERTIV LIEBERT PSA5-700MT120?
Although the PSA5 is designed and manufactured to ensure personal safety, improper use can result in electrical shock or fire. To ensure safety, observe the following precautions:
Turn off and unplug the UPS before cleaning it.
Clean the UPS with a dry cloth. Do not use liquid or aerosol cleaners.
Never block or insert any objects into the ventilation holes or other openings of the UPS.
Do not place the UPS power cord where it might be damaged.
How should I manage battery charging for the VERTIV LIEBERT PSA5-700MT120?
The batteries are valve-regulated, non-spill-able, lead acid and should be kept charged to attain their design life. The PSA5 charges the batteries continuously when it is connected to the utility input power. If the PSA5 will be stored for a long time, we recommend connecting the UPS to input power for at least 24 hours every 4 to 6 months to ensure full recharge of the batteries.
How do I replace the battery in the VERTIV LIEBERT PSA5-700MT120?
IMPORTANT! Before you proceed, please review the battery safety precautions.
You may safely replace the internal battery pack. See the Specifications for the part number of the replacement battery for your UPS model number.
To replace the battery:
1. Turn the UPS on its side or slide it to the edge of a table.
2. Remove the front battery-compartment cover: While firmly pressing in on the V indentation located in the center just below the USB charging ports, slide the battery compartment cover down, then lift off the cover and expose the battery.
3. Disconnect the battery connector by squeezing and gently pulling the two pieces apart.
4. Slide out the existing battery and disconnect the bottom top half of the connector cable from the two battery terminals. Disconnect the red wire first, then the black.
5. Plug the removed connector into the terminals of the new replacement battery. Plug the black wire in first, then the red.
6. Orient the connector and the replacement battery in the same way as the removed battery and slide into the UPS.
7. Reconnect the two halves of the battery connector and slide the front panel back on until it clicks.
8. Press-and-hold the power button for 3 seconds to initiate the battery self-test and clear any previous battery fault warning.
9. Properly dispose of the old batteries at an appropriate recycling facility or return them to Vertiv in the packing material for the new batteries.
What are the technical specifications for the VERTIV LIEBERT PSA5-700MT120?
| Capacity (VA / W) | 700 / 420 |
| Unit Dimensions, in. (mm) W x D x H | 3.9 x 11.4 x 11.0 (99 x 290 x 280) |
| Unit Weight, lbs (kg) | 15.2 (6.9) |
| Input AC | |
| Nominal Voltage | 120 VAC |
| Voltage Range | 86-143 VAC |
| Frequency Range | 60 Hz, ±5 Hz |
| Internal Rear-panel Input Breaker Rating | 7 A, 250 VAC |
| Output AC (On Utility) | |
| Nominal Voltage | 120 VAC |
| Voltage Range | 105-143 VAC |
| Output AC (On Battery) | |
| Nominal Voltage | 120 VAC |
| Voltage Range | Nominal ±5% |
| Frequency Range | 60 Hz, ±1 Hz |
| Waveform | PWM Simulated Sine wave |
| Transfer Time | 10 ms, max. |
| Battery | |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Manufacturer / Model | Leoch / DJW12-9.0, CSB / HR1234W or UPS12460 |
| Battery Quantity x VDC x Ah | 1 x 12V x 9.0Ah |
| Outlets | |
| Battery Backed Outlets | (5) NEMA 5-15R |
| Surge Only Outlets | (5) NEMA 5-15R |
| Environmental | |
| Operating Temperature, degF(degC) | 32-104 (0-40) |
| Audible Noise | <40 dBA @ 3 ft (1 m) from all sides |
What are the approximate battery run times for the VERTIV LIEBERT PSA5-700MT120 at different loads?
Note: Run times in this table are approximate. They are based upon new, fully charged standard battery modules at a temperature of 25 degC (77 degF) with 100% resistive UPS loading.
| LOAD PERCENT OF CAPACITY | 700 VA/420 W (Run time in minutes) |
|---|---|
| 10% | 60 |
| 20% | 27 |
| 25% | 17 |
| 30% | 15 |
| 40% | 10 |
| 50% | 8 |
| 60% | 5 |
| 70% | 4.5 |
| 75% | 3.2 |
| 80% | 3 |
| 90% | 2.5 |
| 100% | 2 |