FREE ENGLISH VERTIV LIEBERT-1500RT120LI (01) PDF DOCUMENT.
FREE ENGLISH VERTIV LIEBERT-1500RT120LI (01) PDF USER GUIDE.
FREE ENGLISH VERTIV LIEBERT-1500RT120LI (01) PDF USER MANUAL.
FREE ENGLISH VERTIV LIEBERT-1500RT120LI (01) PDF OWNER GUIDE.
FREE ENGLISH VERTIV LIEBERT-1500RT120LI (01) PDF OWNER MANUAL.
FREE ENGLISH VERTIV LIEBERT-1500RT120LI (01) PDF REFERENCE GUIDE.
FREE ENGLISH VERTIV LIEBERT-1500RT120LI (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH VERTIV LIEBERT-1500RT120LI (01) PDF REFERENCE MANUAL.
FREE ENGLISH VERTIV LIEBERT-1500RT120LI (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH VERTIV LIEBERT-1500RT120LI (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD VERTIV LIEBERT-1500RT120LI (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What are the descriptions of the numbered parts on the VERTIV LIEBERT-1500RT120LI?
| # | Description | # | Description |
|---|---|---|---|
| 1 | Grounding screw | 6 | SNMP IntelliSlot port |
| 2 | Network/Fax/Modem surge protection input/output | 7 | Emergency Power Off (EPO) connector |
| 3 | USB communication port | 8 | Input circuit breaker |
| 4 | Programmable receptacles | 9 | AC input |
| 5 | Non-programmable receptacles | 10 | Output circuit breaker |
What should I do before installing, connecting, or operating the VERTIV LIEBERT-1500RT120LI?
Before installing, connecting to supply, or operating your VERTIV LIEBERT-1500RT120LI, please review the Safety and Regulatory Statements sheet. For detailed installation, operating, maintenance and troubleshooting information, refer to the User Guide.
What items are included in the box for the VERTIV LIEBERT-1500RT120LI (RT model)?
The following items are included for RT models like the VERTIV LIEBERT-1500RT120LI:
UPS
Accessory box including:
• Quick install guide
• Safety and regulatory statements
• Front bezel
• 4 x Tower feet and screws (M4 x 8 mm)
• 2 x UPS rack ears
• 8 x Rack ear screws (M4 x 8 mm)
• USB type A to B cable
Rail slide kit box:
• Left and right rail set
• 8 x Rail kit screws (M6 x 12 mm)
• 4 x Fixing studs (Ø8.5 x 15.5)
• 6 x Rack nuts (M6)
• NEMA L5-20 to 5-20P adapter cord (PSI5-2200RT120LI only)
What items are included in the box for Mini-Tower (MT) models?
The following items are included for MT models:
• UPS
• Quick install guide
• Safety and regulatory statements
• USB type A to B cable
How should I choose a location for installing the VERTIV LIEBERT-1500RT120LI?
Install the VERTIV LIEBERT-1500RT120LI in a temperature-controlled environment that is free of corrosive and conductive contaminants. Avoid locations near heat or water sources and exposed to direct sunlight. For proper air flow, leave four inches of clearance on the front and back of the RT models, and front, back, and sides of the MT model.
How do I install the VERTIV LIEBERT-1500RT120LI in a rack configuration?
1. Attach the rack ears with four rack ear screws to the front right and left sides of the UPS. Snap the front bezel onto the front of the UPS.
2. Attach two fixing studs to each rail. Select the desired U position and position the rails onto the rack using the fixing studs.
3. Attach two rail kit screws to each rail to secure the rails to the rack.
4. Attach three rack nuts on each side of the rack.
5. Place the UPS with attached rack ears onto the rail supports. The batteries may be temporarily removed for easier installation.
6. Attach two rail kit screws to each UPS rack ear and corresponding rack nut to secure the UPS to the rack.
How do I install the VERTIV LIEBERT-1500RT120LI in a tower configuration?
1. With the front bezel removed, rotate the display clockwise until it is seated in the proper orientation.
2. Connect two tower feet together and attach two screws. Repeat to assemble two tower stands.
3. Snap the front bezel onto the front of the UPS and place the UPS in the tower stands 70 mm from each edge of the UPS.
How do I connect loads to the VERTIV LIEBERT-1500RT120LI?
The VERTIV LIEBERT-1500RT120LI has non-programmable and programmable rear outlets. Plug your critical equipment (such as computer, monitors, etc.) into the non-programmable outlets and your less-critical equipment (such as printers and other less-often used peripherals) into the programmable outlets. Do not plug in the UPS input power until after all load and optional connections have been made.
How do I connect an optional network communication card to the VERTIV LIEBERT-1500RT120LI?
1. Remove the two screws and protective cover on the rear panel network communications port.
2. Insert the card into the port and secure it with the screws. Refer to the documentation with the card for cable connection and operation.
How do I use the Emergency Power-Off (EPO) connection on the VERTIV LIEBERT-1500RT120LI?
To comply with national and local wiring codes and regulations, the EPO connector internally disconnects all power sources to the UPS and connected equipment. To use this feature, remove the factory installed jumper on the rear panel EPO connector and connect to active-open contacts that open during an emergency power off event. Operating logic may be reversed in the Settings menu. If you do not use the EPO connector, leave the factory installed jumper in place and the default (active open) EPO setting in the Settings menu.
How do I connect the AC input power for the VERTIV LIEBERT-1500RT120LI?
Ensure that all the loads are first powered off. Connect to an input-power supply/wall outlet that is properly protected by a circuit breaker in accordance with national and local electrical codes. The input receptacle must be grounded.
How do I start up the VERTIV LIEBERT-1500RT120LI?
Once the UPS is plugged into a stable 120 VAC source, the LCD display briefly turns on and the batteries begin charging. Press and hold the ON/MUTE button for two seconds until the display flashes on. The UPS is in battery self check mode for 10 seconds. After a successful battery self-test, the UPS is in on mode and the output receptacles will provide power.
How do I turn off the VERTIV LIEBERT-1500RT120LI?
Press and hold the OFF/ENTER button for two seconds, turning off all outlets.
How do I fully shut down the VERTIV LIEBERT-1500RT120LI?
After turning the UPS off, remove input power, then remove the front bezel and disconnect the battery connector. Replace the front bezel. The unit is now fully shut down.
What safety precautions should I observe when using the VERTIV LIEBERT-1500RT120LI?
To ensure safety, observe the following precautions:
• Turn off and unplug the UPS before cleaning it.
• Clean the UPS with a dry cloth. Do not use liquid or aerosol cleaners.
• Never block or insert any objects into the UPS ventilation holes or openings.
• Do not place the UPS power cord where it might be damaged.
How should I maintain the battery charge for the VERTIV LIEBERT-1500RT120LI?
The batteries are lithium ion and should be kept charged to attain their design life. The VERTIV LIEBERT-1500RT120LI charges the batteries continuously when it is connected to the utility input power. If the UPS will be stored for a long time, we recommend connecting the UPS to input power for at least two hours every four to six months to ensure full recharge of the batteries.
How do I replace the battery in the VERTIV LIEBERT-1500RT120LI (RT model)?
Before you proceed, please review the battery safety precautions. The battery is hot-swappable and may be replaced while the UPS is on and plugged in. As long as the utility power is available, power to the outlets will remain.
1. Remove the front panel: Remove the front bezel by pulling firmly until the snaps release.
2. Disconnect the battery wires: Disconnect the battery connector by squeezing the ends and pulling apart.
3. Remove the battery: Remove the two screws and the metal battery cover plate. Slide out the existing battery kit.
4. Install the new battery: Plug the connector into the terminals of the new battery, plugging the black wire in first then the red wire. Orient the connector and the new battery in the same way as the original battery, then slide them into the UPS. Replace the metal plate and secure with the two screws. Reconnect the two halves of the battery connector. Snap the front bezel back on.
5. Test the new battery: Press and hold the power button for three seconds to initiate the battery self check mode and to clear any previous battery fault warnings.
6. Dispose of the old battery: Properly dispose of old batteries at an appropriate recycling center or return them to Vertiv in the packing material for the replacement batteries.
How do I replace the battery in a Mini-Tower (MT) model UPS?
Before you proceed, please review the battery safety precautions. The battery is hot-swappable and may be replaced while the UPS is on and plugged in. As long as the utility power is available, power to the outlets will remain.
1. Remove the battery cover screws: Place the unit on its left side and remove the six screws holding the metal battery cover plate in place.
2. Remove the battery cover: Remove the metal battery cover from the unit.
3. Remove the battery: Slide out the existing battery and disconnect the two halves of the battery connector.
4. Install the new battery: Plug the connector into the terminals of the new battery, plugging the black wire in first then the red wire. Orient the new battery in the same way as the original battery, connect the two halves of the battery connector, then slide them into the UPS. Replace the metal plate and secure with the six screws.
5. Test the new battery: Press and hold the power button for three seconds to initiate the battery self check mode and to clear any previous battery fault warnings.
6. Dispose of the old battery: Properly dispose of old batteries at an appropriate recycling center or return them to Vertiv in the packing material for the replacement batteries.
CLICK HERE TO DOWNLOAD VERTIV LIEBERT-1500RT120LI (01) PDF DOCUMENT
