How do I prepare the STORZ & BICKEL PLENTY for use?
Step 1. Open the Filling Chamber.
Step 2. Grind your materials.
Step 3. Fill the Filling Chamber. Always fill the Filling Chamber completely up to the upper edge.
What is the correct way to fill the Filling Chamber on the STORZ & BICKEL PLENTY?
There are two correct ways to fill the chamber:
Completely filled: For a full session, fill the chamber completely with your ground materials. This will produce vapor.
Partially filled: If you only wish to partially fill the chamber, you must place the Liquid Pad on top of your materials. This will also produce vapor.
An incorrectly filled chamber, where it is only partially filled without the Liquid Pad, will produce hot air instead of vapor.
How do I operate the STORZ & BICKEL PLENTY vaporizer?
Step 1. Switch on the device using the orange power switch.
Step 2. Press the auto off release handle.
Step 3. Choose your desired temperature using the temperature scale dial.
What are the vaporization temperatures for the STORZ & BICKEL PLENTY?
The vaporization temperature scale has 7 levels:
| Level | Temperature (°C) | Temperature (°F) |
|---|---|---|
| 1 | 130°C | 266°F |
| 2 | 142°C | 288°F |
| 3 | 154°C | 310°F |
| 4 | 166°C | 331°F |
| 5 | 178°C | 352°F |
| 6 | 190°C | 374°F |
| 7 | 202°C | 396°F |
What are the main components of the STORZ & BICKEL PLENTY Vaporization Unit?
The PLENTY Vaporization Unit consists of the following parts:
Mouthpiece
Upper Tubing Section (long)
Cooling Coil
Lower Tubing Section (short)
Filling Chamber Cap
Upper Screen
Lower Screen
Filling Chamber Cylinder
Filling Chamber Housing
How do I disassemble the STORZ & BICKEL PLENTY for cleaning?
Step 1. Pull the Mouthpiece away from the Cooling Coil.
Step 2. Pull the Cooling Coil out of the Filling Chamber Cap.
Step 3. Push out the Upper Screen with the help of the Cleaning Brush.
Step 4. To disassemble the Filling Chamber, push out the Filling Chamber Cylinder.
Step 5. Push out the Lower Screen.
How should I clean the components of the STORZ & BICKEL PLENTY?
Perform a manual cleaning of the disassembled components, such as the Filling Chamber Cylinder and Housing, using alcohol (min. 90%) or dishwashing soap.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD STORZ & BICKEL PLENTY (01) PDF DOCUMENT