What are the general safety warnings for the SHARK HP070 air purifier?

To reduce the risk of fire, electric shock, or injury when using your SHARK HP070, follow these general warnings:

1. This appliance has a polarized plug. To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature. Unplug or disconnect the appliance from the power supply before servicing.

2. DO NOT operate any unit with a damaged cord or plug. Discard the unit or return to an authorized service facility for examination and/or repair.

3. If the power cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.

4. This appliance should only be placed on flat and dry surfaces.

5. This appliance is not intended for use by anyone (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

6. Children should be supervised to ensure that they DO NOT play with the appliance.

7. Cleaning and user maintenance shall not be made by children without supervision.

8. Prior to cleaning or other maintenance, the appliance must be unplugged from the electrical outlet.

9. DO NOT handle plug or appliance with wet hands.

10. DO NOT use without filter in place.

11. Only use Shark® branded filters and accessories.

12. DO NOT use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce airflow.

13. DO NOT use if airflow is restricted. If the air paths become blocked, turn the appliance off and unplug from electrical outlet. Remove all obstructions before you plug in and turn on the unit again.

14. DO NOT use if appliance is not working as it should, or has been dropped, damaged, left outdoors, or dropped into water.

15. DO NOT place appliance on unstable surfaces such as chairs or tables.

16. Turn off all controls before plugging in or unplugging the appliance.

17. Unplug from electrical outlet when not in use and before any maintenance or cleaning.

18. Hand wash exterior/hard plastic/non-electronic parts with water only. Do not immerse. Cleaning with chemicals could damage the unit.

19. Make sure filter is in place after routine maintenance.

20. Not suitable for use with solid-state speed controls.

21. The appliance is only to be used with the power supply unit provided with the appliance.


What are the safety precautions for handling the power cord of the SHARK HP070?

To avoid damaging the power cord of your SHARK HP070, please adhere to the following:

a) DO NOT run the cord under carpeting. DO NOT cover the cord with throw rugs, runners, or similar coverings. DO NOT route the cord under furniture or appliances. Keep the cord away from high traffic areas where it will not be tripped over.

b) DO NOT pull or carry the appliance by the cord or use the cord as a handle.

c) DO NOT unplug by pulling on the cord. Grasp the plug, not the cord.

d) DO NOT stand the appliance on the power cord, close a door on the cord, pull the cord around sharp corners, or leave the cord near heated surfaces.


In which areas should I avoid using the SHARK HP070?

DO NOT use your SHARK HP070 in the following areas:

a) Wet or damp surfaces

b) Outdoor areas

c) Spaces that are enclosed and may contain explosive or toxic fumes or vapors (lighter fluid, gasoline, kerosene, paint, paint thinners, mothproofing substances, or flammable dust)


What are the safety guidelines for the Odor Neutralizer Technology cartridge on the SHARK HP070?

Observe the following when interacting with the Odor Neutralizer Technology cartridge for your SHARK HP070:

a) DO NOT attempt to disassemble the Odor Neutralizer Technology cartridge.

b) Avoid direct contact with the fragrance pod in the cartridge.

c) DO NOT directly inhale from the Odor Neutralizer Technology cartridge.

d) Keep away from children and pets.

e) Keep away from heat, sparks, and open flame.

f) DO NOT place in direct sunlight.

g) Avoid contact with fabrics and finished surfaces.


What is the first aid procedure for the fragrance cartridge of the SHARK HP070?

Follow these first aid instructions if you come into contact with the fragrance cartridge:

a) Eye contact: Remove contact lenses if present. Rinse continuously with water for several minutes.

b) Skin contact: Wash hands thoroughly after handling. If irritation or rash develops, seek medical advice/attention.

c) Inhalation: Move person to fresh air if they are experiencing any respiratory symptoms. If symptoms persist, seek medical advice/attention.

d) Ingestion: DO NOT induce vomiting. Seek medical advice/attention.


What are the parts of the SHARK HP070 air purifier?

The SHARK HP070 air purifier consists of the following parts:

1. Air Output Vents

2. Odor Neutralizer Technology Dial

3. Control Panel

4. Front Display

5. Air Purifier Body

6. Air Intake Vents

7. Mesh Dust Filter

8. HEPA Filter

9. HEPA Filter Door


What are the tips for setting up my SHARK HP070 air purifier?

For best performance, follow these tips when setting up your SHARK HP070:

• Make sure the front panel of the air purifier faces away from the closest wall.

• Do not move the unit while it is running. Turn off the power and unplug the air purifier before moving it.

• Make sure the air intake vents are not blocked.

• Do not place anything on the air purifier.

• Do not place the air purifier near heaters or radiators.

• Keep the air purifier out of direct sunlight and away from water or other liquid.

• Keep all nearby doors and windows closed when operating the air purifier.

• Avoid using in very humid environments.


How do I set up my SHARK HP070 for the first time?

Follow these steps to set up your SHARK HP070:

1. DO NOT plug in the air purifier. First, carefully turn the air purifier upside down and place it on a level floor surface. Rotate the filter door counterclockwise to unlock it, then lift it off to access the HEPA filter.

2. Take the HEPA filter out of its plastic packaging. Reinstall the HEPA filter in either orientation.

3. With the HEPA filter reinstalled, rotate the filter door clockwise until it clicks into place.

4. Set up the air purifier on a level surface, at least 3 inches (8 cm) from walls and objects. If using, find the Odor Neutralizer Technology cartridge and follow the instructions to install it.

5. Carefully remove the yellow sticker on the front of the air purifier to access the display panel. Plug the air purifier into an electrical outlet and press the power button on the top control panel.

6. When the power is on, the air purifier will begin to analyze the air quality, indicated by the rotating lights. After a few seconds, the air purifier will display the current air quality.


What are the functions of the top control panel buttons on the SHARK HP070?

The top control panel of your SHARK HP070 has the following buttons:

On/Off: Press to turn the power on or off.

Fan Speed: Press repeatedly to cycle through the fan speed options: A Auto, 1 Quiet, 2 Low, 3 Medium, 4 High, 5 Maximum. For optimal filter life and performance, select Auto mode. In Auto mode, the fan speed automatically adjusts based on air quality.

Air Info: Press to switch between air quality display options and filter life information.

Brightness: Adjusts the brightness of both the front display screen and the top control panel. Switch between 3 options: full brightness, partially dim, fully dim.

Child Lock: Press and hold the Brightness and Fan speed buttons at the same time for two seconds to lock the top control panel buttons. To unlock, press and hold both buttons again for two seconds.


How do I use the Eco Mode and turn off beeping on my SHARK HP070?

Optimize Performance in Eco Mode: After 100% clean air status is achieved for 5 minutes in Auto Mode, your SHARK HP070 will enter Eco Mode. Your unit’s filter life will be optimized.

Turn Off Beeping: To turn off notification sounds, press and hold the Air Info and Fan Speed buttons at the same time for two seconds. To resume, press and hold both buttons again.


How do I understand the air quality display options on my SHARK HP070?

The built-in sensor on your SHARK HP070 detects your air quality to give you real-time information. Use the AIR INFO button to switch between air quality display options.

INFO REAL-TIME READING
% CLEAN AIR

Displays the air quality rating:

• Poor: 0%-69% • Fair: 70%-84% • Good: 85%-100%

% CLEAN AIR uses particulate matter (PM) air quality standards as determined by the EPA to calculate the air quality rating.

PARTICLE SIZES The PM (particulate matter) value is the amount of particulate in your air, measured in micrograms (µg) per cubic meter. Your air purifier measures three particle sizes, PM1, PM2.5, and PM10.
PM1 Displays the number of PM1-sized particles in your air, including ultra-fine allergens.*
*Allergens refers to non-living matter.
PM2.5 Displays the number of PM2.5-sized particles in your air, including smoke.
PM10 Displays the number of PM10-sized particles in your air, including dust and pollen.

How do I understand the air quality color rings on the front display of my SHARK HP070?

The rings on the front display of your SHARK HP070 change color to indicate your air quality:

GOOD (85-100%): A blue ring means your air quality is good, with a low level of particle concentration.

FAIR (70-84%): An amber ring means your air quality is fair, with a moderate level of particle concentration. For better results, increase fan speed or select Auto Mode.

POOR (0-69%): A red ring means your air quality is poor, with a high level of particle concentration. For better results, increase fan speed or select Auto Mode.

Note: The air quality sensor uses a cumulative particle count across all particle sizes to determine the percentage of clean air.


How can I optimize the fan speed on my SHARK HP070?

Your SHARK HP070 air purifier has 5 speed settings plus Auto Mode. Adjust fan speed to optimize your cleaning performance.

SPEED BEST FOR
AUTO Optimizing HEPA filter life
1-2 Quiet operation
3-4 Reducing odors
5 (MAX) Maximum purification and debris capture

What are the recommended settings for the SHARK HP070?

We recommend using this air purifier in Auto Mode. Auto Mode leverages your air purifier’s particle sensor, and this adjusts the fan speed automatically. Higher fan speeds work best for reducing odors and capturing debris most effectively.


Where should I set up my SHARK HP070 air purifier?

We recommend setting up the SHARK HP070 in the room of your home where there is the most activity. This will help to clear the air of pollutants and odors as they are introduced. Note: This model is recommended for smaller rooms.


What is Eco mode on the SHARK HP070?

After 100% clean air is achieved for 5 minutes in Auto Mode, your SHARK HP070 air purifier will enter Eco Mode. The fan will turn off until a significant number of particles are detected, optimizing your HEPA filter’s life.


Can I mute the beeping sounds on the SHARK HP070?

Yes. To turn off notification sounds, press and hold the Air Info and Fan Speed buttons at the same time for two seconds. To reactivate sounds, press and hold both buttons for 2 seconds again.


Why are the top control panel buttons on my SHARK HP070 not working?

Your SHARK HP070 may have the child lock setting activated. Press and hold the Brightness and Fan Speed button for two seconds to turn this setting on or off.


Why is the air quality on my SHARK HP070 always at 100%?

If your SHARK HP070 displays a blue ring, your air quality is good. However, air quality will fluctuate as you introduce pollutants into your home. Activities like smoking, cooking, dusting, or spraying cleaning products (among other things) can add pollutants to your air. The Clean Sense IQ™ technology tracks this fluctuation in real time and adjusts as it detects particles. To determine if the sensor is working correctly, spray perfume or aerosol cleaning product near the sensor on the back of the air purifier.


Why is the air quality on my SHARK HP070 never at 100% or always at 0%?

If your air quality never reaches 100%, make sure that the HEPA filter is properly installed and that its original plastic packaging has been removed. Activities like smoking, burning candles, running a humidifier, opening windows, and cooking (among other things) can add more pollutants to your air. Make sure to survey your environment and remove anything that could be causing low air quality.

If the problem persists after these checks, the air quality sensor on the back of the air purifier may be dirty, causing a false reading. First, turn off and unplug the unit. Remove the mesh dust filter to locate the sensor on the back. Use a hand vacuum or hose attachment to clean the area around the sensor. After cleaning, wait 30 seconds before plugging the unit back in and turning it on. Let it run for 24 hours and monitor the air quality.


What is the purpose of the mesh dust filter on the SHARK HP070?

This easy-to-clean mesh dust filter captures large debris like hair, dust, and lint to protect the 3-layer HEPA filter. Maintenance is required on this filter when indicated on the front display. Refer to the Mesh Dust Filter Maintenance section for more information.


How do I know when to clean the pre-filter (mesh dust filter) on my SHARK HP070?

When the mesh dust filter needs maintenance, the front display will show a pulsing red ring along with the text “check dust filter.”


Can I wash the HEPA filter on my SHARK HP070?

No, the HEPA filter is not washable. Keep the filter away from water and dispose of it when it is dirty.


How do I check if the mesh dust filter on my SHARK HP070 needs cleaning?

When the mesh dust filter on your SHARK HP070 needs maintenance, the front display will show a screen with a pulsing red ring and the text “CHECK DUST FILTERS”.


How do I clean the mesh dust filter on my SHARK HP070?

When the “Check Dust Filter” message appears, KEEP THE AIR PURIFIER PLUGGED IN and running, and complete the following steps:

1. LOCATE AND REMOVE MESH DUST FILTER: Gently slide up the filter and remove it. Check the screen for dust and debris buildup.

2. CLEAN DUST FILTER: Use a vacuum cleaner on low speed with a soft brush attachment OR a cloth/towel to remove debris from the mesh screen. DO NOT use abrasive chemical cleaners.

3. ADDITIONAL CLEANING (NOT REQUIRED): If additional cleaning is required, rinse the mesh dust filter with room temperature tap water. Be sure to completely dry the screen for 12 hours before reinstalling. DO NOT USE the air purifier when the mesh filter is wet.

4. REINSTALL MESH DUST FILTER: Gently reinsert the mesh dust filter into the slot on the side of the air purifier. Be sure to push the dust filter into place until it is flush with the air purifier body.

5. RECALIBRATION: Once the filter has been cleaned and reinstalled, the air purifier will recalibrate and begin to analyze air quality, indicated by the rotating lights.

Note: To manually reset the Check Dust Filter indicator, press and hold the Air Info button on the top control panel for 1.5 seconds.


How do I clean the exterior of my SHARK HP070?

For best results, clean the exterior of your SHARK HP070 every two months or as needed. Use a microfiber cloth to remove dust. To clean, wipe down the exterior with a microfiber cloth dampened with warm, soapy water. Avoid excess water and abrasive chemical cleaners to prevent damage. Be sure to unplug the air purifier before cleaning.


How do I clean the interior of my SHARK HP070?

For best results, clean the interior of your SHARK HP070 every two months or as needed. First, unplug the unit. Remove the filter door, take out the HEPA filter, and use a vacuum cleaner or a microfiber cloth to remove dust and debris from the interior. DO NOT use abrasive chemical cleaners or water on the inside of the air purifier.


How do I install the Odor Neutralizer Technology cartridge assembly on my SHARK HP070?

Follow these steps to install the cartridge assembly:

1. OPEN THE PACKAGED ODOR CARTRIDGE ASSEMBLY: Remove the odor cartridge assembly from the cardboard box and aluminum bag.

2. INSERT ODOR CARTRIDGE ASSEMBLY INTO AIR PURIFIER: Flip up the handle on the odor dial, align the arrows, then insert the assembly into the air purifier.

3. ROTATE UNTIL CLICK: To lock and engage the odor cartridge assembly, rotate it counterclockwise until it clicks at least once. Continue to rotate the dial toward the high position to increase the intensity.


What are the different intensity settings for the Odor Neutralizer Technology on the SHARK HP070?

The Odor Neutralizer Technology dial on your SHARK HP070 has 4 intensity settings: Low, Medium, High, and Off.

ODOR DIAL POSITION SETTING RECOMMENDED FOR
1 CLICK OFF • When you are not actively looking to reduce odors. This will extend the life of the odor cartridge.
2 CLICKS LOW • Mild odor events such as trash smells.
• Small spaces like a bathroom or entryway.
3 CLICKS MEDIUM • Strong odor events such as cooking or pet smells.
• Mid-sized spaces like a bedroom or kitchen.
4 CLICKS HIGH • Optimal odor-reducing performance.
• Extreme odor events such as smoke or lingering burnt smells.
• Large spaces like a living room or multiple rooms.

How do I remove the Odor Neutralizer cartridge from my SHARK HP070?

To remove the odor cartridge from the dial, flip up the handle and rotate the odor dial clockwise until the two arrows are aligned. Pull the handle to remove the dial and access the cartridge.


What should I know about the fragrance strength and maintenance of the Odor Neutralizer cartridge for my SHARK HP070?

Fragrance Strength Over Time: The intensity of the Odor Neutralizer Technology’s fragrance may diminish over time. It may also have no noticeable fragrance at all. This is natural and does not indicate that the technology is not working. Follow replacement instructions to ensure continued performance.

Maintenance Required: Replace the cartridge as recommended under Odor Cartridge Replacement.


How do I replace the Odor Neutralizer Technology cartridge on my SHARK HP070?

Follow these steps to replace the cartridge:

1. REMOVE THE ODOR CARTRIDGE ASSEMBLY: Flip up the handle and rotate the dial counterclockwise until the two arrows are aligned. Pull the handle to remove the dial from the air purifier.

2. REMOVE OLD ODOR CARTRIDGE: Rotate the cartridge counterclockwise in the dial housing and pull out the cartridge to remove it.

3. REMOVE NEW CARTRIDGE FROM BAG: Remove the new odor cartridge from the sealed packaging. To maintain the life of the cartridge, keep it in the sealed packaging until you are ready to install it.

4. INSTALL NEW CARTRIDGE IN DIAL: Align the yellow arrow on the side of the cartridge with the yellow arrow on the side of the dial cover, then insert the cartridge into the dial. Rotate the cartridge clockwise to lock it in place.

5. INSTALL THE ODOR DIAL ASSEMBLY: Align the arrow on the dial cover with the arrow on the air purifier, then reinsert the dial into the air purifier. Rotate the dial counterclockwise until it clicks into an intensity setting to engage. Rotate further to change the intensity setting.

6. USED CARTRIDGE DISPOSAL: Dispose of the old cartridge by dropping it into the trash.

Note: Odor cartridges should be replaced every 3 months or as needed for optimal Odor Neutralizer Technology performance.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD SHARK HP070 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.