What are the key safety instructions for using the IFM UGT528 sensor?

When using the IFM UGT528, please adhere to the following safety instructions:

• Read the operating instructions document before setting up the product and keep it for the entire service life of the sensor.

• Ensure the product is suitable for the specific applications and environmental conditions without any restrictions.

• Only use the product for its intended purpose, which is monitoring levels and detecting objects.

• Failure to adhere to the operating instructions or technical data may result in personal injury and/or damage to property.

• The manufacturer assumes no liability or warranty for consequences caused by tampering with the product or incorrect use by the operator.

• Installation, electrical connection, set-up, operation, and maintenance of the product must be carried out by qualified personnel authorized by the machine operator.

• Protect the sensor unit and its cables against damage.


What are the important considerations for installing the IFM UGT528?

For proper installation of the IFM UGT528, secure the unit to a bracket and take note of the following points:

• Sound-absorbing surfaces can have a negative effect on the reliable function of the sensor.

• Always consider the dead zone (refer to the technical data sheet). No object detection is possible within the dead zone.

• For units with a metal housing (according to UL 508), you must observe a minimum distance of 12.7 mm between the sensor and non-insulated live parts.


How do I electrically connect the IFM UGT528?

To connect the IFM UGT528, first disconnect the power. Then, connect the device according to the type selected, using the following pinout and color codes (to DIN EN 60947-5-2):

• Pin 1: BN (brown) – L+

• Pin 2: WH (white) – OUT2 (switching output)

• Pin 3: BU (blue) – L-

• Pin 4: BK (black) – OUT1 (switching output / IO-Link)


How are the settings configured on the IFM UGT528?

The unit and its parameters for the IFM UGT528 are set by means of IO-Link. Upon delivery, the unit can also be used without IO-Link setting, as it comes with preset switch points.


What are the IO-Link capabilities of the IFM UGT528?

The IFM UGT528 has an IO-Link communication interface that enables direct access to process and diagnostic data and allows for parameter setting while the unit is in operation. The unit is designed for fully bidirectional communication. The following options are available via IO-Link:

• Remote display: Read and display the current status.

• Remote parameter setting: Read and change the current parameters via IO-Link parameter setting.

Operation via IO-Link requires an IO-Link master. Communication with a PC is possible when the system is not in operation, using suitable IO-Link software and an IO-Link adapter cable.


How can I check if the IFM UGT528 is operating correctly and what do the LEDs indicate?

To check if the IFM UGT528 is operating correctly, bring about a sensor response by taking suitable measures and observing the LED displays. The meaning of the LEDs is as follows:

LED Status Meaning
Status LED 1/2 yellow ON Switching output is active.
Echo LED green ON Echo is received.
Echo LED green flashing Short circuit at the output.

The status LEDs 1/2 (yellow) also function as a setting aid and output indication. The echo LED (green), labeled as 3, is on when an object or background is detected.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD IFM UGT528 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.