What are the meanings of the symbols used in the operating instructions for the IFM E30467?

The symbols used in the operating instructions are as follows:

: Requirement

: Instructions

: Reaction, result

[…]: Designation of keys, buttons or indications

: Cross-reference

! (Important note): Non-compliance may result in malfunction or interference.

i (Information): Supplementary note.


What are the main safety instructions for the IFM E30467?

Please adhere to the following safety instructions when using the IFM E30467:

• Read the operating instructions before setting up the product and keep it during the entire service life.

• The product must be suitable for the corresponding applications and environmental conditions without any restrictions.

• Only use the product for its intended purpose.

• Only use the product for permissible media (refer to technical data).

• If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property may occur.

• The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator.

• Installation, set-up, operation and maintenance of the product must be carried out by qualified personnel authorised by the machine operator.

• Protect units, accessories and cables against damage.


What is the intended use of the IFM E30467 filter cover?

The IFM E30467 filter cover is a protective element that can be used for pressure sensors with screwed pressure compensation elements to avoid soiling of the ventilation diaphragm in harsh environments.

How do I remove the existing filter cover from the pressure sensor before installing the IFM E30467?

Follow these steps to remove the existing filter cover:

1. Remove the filter cover (A) using an appropriate tool.

2. Pull the ventilation diaphragm (C) off the base (B).

The sensor is now prepared for the installation of optional filter covers.

Note: Ensure that the sensor is not subjected to moisture during installation.


What should I know before using a closed filter cover (E30148) with a pressure sensor?

When using the closed filter cover, please note the following:

• Please ensure that the application is suitable for use without the pressure compensation being active.

• The closed filter cover does not allow any pressure compensation of the relative pressure meter.

• The internal pressure of the sensor changes by 35 mbar for every 10 K of temperature change.

The closed filter cover is recommended only for harsh environments and applications where decreased accuracy is accepted.


What are the components of the IFM E30467 filter cover set?

The IFM E30467 set consists of the following components for ventilation in demanding applications:

1. Adapter with integrated ventilation diaphragm

2. Tube connection

3. Plug-in element with integrated ventilation diaphragm

4. Vent tube

5. Plug-in element with integrated ventilation diaphragm

These protective elements provide better protection of the ventilation diaphragm against unfavourable environmental conditions such as heavy soiling, excess condensate, or high air humidity.


How do I install the primary protective element of the IFM E30467?

1. Remove the existing filter cover from the pressure sensor.

2. Mount the adapter (1) and the tube connection (2) to the threaded ferrule (6).

3. Loosen the locking screw (8) and turn the tube connection so that the venting faces downwards.

4. Tighten the locking screw (8) with 2.5 … 3.5 Nm.


How do I install the secondary protective element of the IFM E30467?

First, install the primary protective element. Then, choose one of the following secondary element installations:

Plug-in version:

1. Push the plug-in element (3) into the tube connection (2) until the end stop has been reached.

2. Loosen the locking screw (8) and turn the tube connection into a horizontal position so that the ventilation diaphragm in the plug-in element is in a vertical position.

3. Tighten the locking screw with 2.5 … 3.5 Nm.

Tube version:

1. Push the vent tube (4) with plug-in element (5) into the tube connection (2) until the end stop has been reached.

2. Fix the tube end with the plug-in element in a horizontal position so that the ventilation diaphragm in the plug-in element (5) is in a vertical position.

Important: The tube must not be kinked or blocked.

Note: The tube version can also be used without a plug-in element. In this case, the open tube end must face downwards. A tube of any length can be used.


What is the correct orientation for the IFM E30467 filter cover during installation?

Select the installation situation so that the filter cover is horizontal and the condensate can drain off due to gravity.

Ideal orientation (1): The filter cover is in a horizontal position.

• The ventilation diaphragm (2) in the filter cover is in a vertical position.

Maximum inclination of the filter cover is 30° (3).


How should the IFM E30467 be handled for disposal or return?

• After use, dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations.

• In case of a return shipment, ensure that the unit is free from soiling, especially from dangerous and toxic substances.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD IFM E30467 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.