What do the symbols in the IFM E30139 operating instructions mean?

The symbols used in the operating instructions have the following meanings:

► Requirement

► Instructions

▷ Reaction, result

[…] Designation of keys, buttons or indications

→ Cross-reference

Important note: Non-compliance may result in malfunction or interference.

Information: Supplementary note.


What are the safety instructions for using the IFM E30139 filter cover?

Please adhere to the following safety instructions:

• Read this document before setting up the product and keep it during the entire service life.

• The product must be suitable for the corresponding applications and environmental conditions without any restrictions.

• Only use the product for its intended purpose.

• Only use the product for permissible media.

• If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property may occur.

• The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator.

• Installation, set-up, operation and maintenance of the product must be carried out by qualified personnel authorised by the machine operator.

• Protect units, accessories and cables against damage.


What is the intended use of the IFM E30139 filter cover?

The different protective elements (filter covers) like the IFM E30139 can be used for pressure sensors with screwed pressure compensation elements to avoid soiling of the ventilation diaphragm in harsh environments.


What is included in the IFM E30139 set of accessories?

The IFM E30139 set of accessories consists of a filter cover with an integrated ventilation diaphragm and a tube fitting with a vent tube.


How do I remove the existing filter cover before installing the IFM E30139?

Follow these steps to remove the existing filter cover:

1. Remove the filter cover (A) using an appropriate tool.

2. Pull the ventilation diaphragm (C) off the base (B).

▷ The sensor is now prepared for the installation of the IFM E30139.

Important: Ensure that the sensor is not subjected to moisture during installation.


How do I install the IFM E30139 filter cover?

To install the IFM E30139 filter cover, please follow these steps:

1. Remove the existing filter cover. See the relevant instructions for removal.

2. Screw the new filter cover (3) with its integrated ventilation diaphragm onto the base (B) and tighten it using a spanner, across flats 11. The tightening torque is 2.5…3.5 Nm.

3. Attach the tube (L = 0.5 m, internal diameter 3 mm, polyamide) onto the filter cover (3) and place the free end in a protected area.


What should I consider when using a closed filter cover (e.g., E30148)?

When using a closed filter cover, please ensure the application is suitable for use without active pressure compensation. Note the following:

• The closed filter cover does not allow any pressure compensation of the relative pressure meter.

• The internal pressure of the sensor changes by 35 mbar for every 10 K of temperature change.

The closed filter cover is recommended only for harsh environments and applications where decreased accuracy is accepted.


What is the correct orientation for the IFM E30139 filter cover after installation?

Select the installation situation so that the filter cover is horizontal and the condensate can drain off due to gravity.

Ideal orientation (1): The filter cover is in a horizontal position.

• The ventilation diaphragm (2) in the filter cover is in a vertical position.

Maximum inclination of the filter cover: 30° (3).


How should I dispose of the IFM E30139 filter cover?

• After use, dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations.

• In case of return shipment, ensure that the unit is free from soiling, especially from dangerous and toxic substances.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD IFM E30139 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.